© 2002 Eaton Corporation. All rights reserved. Powerware P13 and P14 UPS 950 Watts /1400 VA 120 and...
-
Upload
marilyn-collins -
Category
Documents
-
view
216 -
download
1
Transcript of © 2002 Eaton Corporation. All rights reserved. Powerware P13 and P14 UPS 950 Watts /1400 VA 120 and...
© 2002 Eaton Corporation. All rights reserved.
PowerwareP13 and P14 UPS
950 Watts /1400 VA
120 and 230 Vac models
p13pres.ppt rev 02/21/06
2
Agenda
Features and Benefits Applications Product Features Overview Software Out-of-Box Usability Collaterals
3
P13 and P14 Product Snapshot P13 P14
IBM Feature Code 9910-P13 9910-P14
IBM Part Number 39J2532 39J4810*
Topology Line-interactive Line-interactive
Power Rating 950 Watts/1400 VA 950 Watts/1400 VA
Voltage 120 Vac 220-240 Vac
Frequency 50/60 Hz 50/60 Hz
Configuration Tower Tower
Dimensions (HxWxD) 7.6 x 5.9 x 15.4 in 7.6 x 5.9 x 15.4 in
Weight 37.0 lbs 37.0 lbs
Input Connection 5-15P IEC-320-C14
Output Connection (6) 5-15R (6) IEC-320-C13
Battery Runtime (half/full) 14/5 min 14/5 min
Color Black Black
*RoHS compliant part number. Old IBM part number is 39J2533.
4
P13 and P14 Features and Benefits
• Cost-effective power protection for entry to mid-level servers
• Eliminates unwanted power quality surprises with Buck and Boost voltage regulation
• Single SKU supports i5-iSeries and p5-pSeries, OpenPower with both serial and relay cables included with UPS
• Minimizes downtime with hot-swappable batteries
• Tested and approved by IBM to assure out-of-box usability
• Includes premium IBM warranty which uniquely covers batteries, too
5
P13 and P14 Applications
Cost-effective, entry-level power protection for:
• i5 and iSeries servers
• p5 and pSeries
• OpenPower servers
6
Application Matrix
ExpectedIBM Server Watts Vac P13 P14 Runtime
i5-iSeries
9406-520, 9405-520 600 100-127 10
9406-520, 9405-520 600 200-240 10
p5-pSeries and OpenPower
9111-520 600 100-127 10
9111-520 600 200-240 10
7028-6E4 p630 750 100-127 7
7028-6E4 p630 750 200-240 7
7029-6E3 p615 450 100-127 16
7029-6E3 P615 450 200-240 16
7
Series 5 Power ProtectionThe Powerware 5115 delivers power protection from power problems that threaten your equipment and priceless data
Power Failures
Power sags
Power surges
Brownouts
Overvoltage
The Powerware 5115 also offers varying degrees of protection against other power problems as well
8
Advanced Battery Management(ABM®) Technology
• Increases battery service life by charging only when needed
• Optimizes recharge time
• Does not trickle charge & starve the electrolyte
• Microprocessor controlled – only true and automatic battery check (periodic, controlled discharge) for accurate advanced battery failure protection
• Sleep features – no unnecessary battery drain
9
Buck and Boost Voltage Regulation
• Wide input voltage window: regulates voltage fluctuations
• Regulated output voltage: prevents voltage fluctuations from reaching connected load
Nominal Voltage+6%
-10%
+20%
-20%
Input Voltage to UPS Output Voltage to Load
10
Sine Wave Output
When the UPS switches to battery power, it provides smooth sine wave output to the connected load
11
Hot-swappable Batteries
Extends the service life of the UPS by allowing the user to replace batteries without shutting down the connected load
12
Battery Runtime (in minutes)
Watts VA Runtime
128 200 58
192 300 41
320 500 28
402 600 19
503 750 14
603 900 10
670 1000 8
804 1200 6
938 1400 5
13
Simple, User-friendly Interface
On/Off Power
Alarm Silence/Self-Test
UPS Power On
UPS On Battery
Overload
Service Indicator
Start-On-Battery: Power up UPS in
absence of utility power
14
P13 Rear Panel
Network Transient Protector
DIP Switches
6-foot Line Cord w/5-15P
Input Overcurrent Protector
(6) 5-15R
Site Wiring Fault
USB Port
Serial Port
15
P14 Rear Panel
Input Overcurrent Protector
Network Transient Protector
DIP Switches
IEC-320 Input Connector
IEC-320, 10A Receptacles1
USB Port
Serial Port
1 P14 includes three (3) IEC-320-C13 to IEC-320-C14 1.8 m power cords
16
Site Wiring Fault Indicator (P13 model)
UPS verifies that the wall socket to which it is connected is properly wired
Red light illuminates to indicate a problem with the wall socket; either the ground wire connectiondoes not exist or the line and neutral wires are reversed
17
Nominal Voltage Selection: DIP Switches
Select 110 or 120V (default) for P13
Select 220, 230 (default), or 240V for P14
Select nominal voltage by setting DIP switches
18
The P13 offers protection from disturbances that travel through the network (RJ45) and phone lines (RJ11)
Network Transient Protector
19
USB and Serial Communication
UPS is equipped with both USB and serial communication ports (cables for both are included)
Serial Port
USB Port
Single SKU supports i5-iSeries and p5-pSeries systems
20
Powerware Software Suite
The Powerware 5115 includes the exclusive Software Suite CD, incorporating the best power technology with all the control software you need for effective network monitoring and analysis, power management, SNMP and UPS remote shutdown. Software Suite Contents• LanSafe • CheckUPS Basic • Advanced NetWatch • PowerVision (30-day trial version)
Software Installation Wizard• Takes the guesswork out of UPS
software installation • Selects the right software for your system • Links available for new downloads
21
LanSafe PowerScope View
• PowerScope view provides a crisp, real-time animation of the power flow through the UPS components
• Vital status and metering information is intuitively available at-a-glance
• The UPS component topology is automatically detected (line-interactive for P13 and P14)
22
PowerScope View Elements
Input Voltage Meter Output Voltage Meter
Animated UPS topology display
Battery Run time
Amount of time the UPS can operate on battery
power
Load %
The percent of maximum output load the UPS supports. The number increases when new devices are plugged into the
UPS
Advanced Battery Management (ABM)
animated status indicator
Doubles battery life by charging only when necessary
Toolbar ButtonsQuick-launch most common tasks
LanSafe Controller name, location and UPS model
Active Events Log
23
Why Use LanSafe Software?
1. Prevent system crashes When a power failure outlasts the UPS battery run time, LanSafe automatically performs a graceful operating system shutdown.
2. Avoid data loss LanSafe saves all unsaved work-in-progress.
3. Protect valuable applications LanSafe protects applications from becoming corrupt by closing them in an orderly fashion.
4. Stay informed Monitor and receive UPS alarms via network broadcasts, SNMP, email, pager or mobile phone.
5. Control the power Manage all UPSs on the network, turn them on and off, check battery health, create sequential shutdown scenarios, integrate UPSs into SNMP Network Management Systems.
24
Powerware Extensions Software for IBM Director Seamless UPS and software
integration into IBM Director Network Management System (NMS)
Real time monitoring, management and alarm notification of all UPSs in the network: e.g. battery status, battery replacement, load level and metering information
Automatically launches LanSafe and ConnectUPS Web/SNMP Card applications from within Director
Available on Powerware web
FREE-OF-CHARGE
25
P13 and P14 Out-of-Box Usability
9910 philosophy of a complete package UPS, power1 & communication cables, software, mounting
hardware and manuals
1 P14 includes three (3) IEC-320-C13 toIEC-320-C14 1.8 m power cords
26
P13 and P14 Collateral
Additional information available at
www.powerware.com/ibm Select your region. Click “Products”, click “9910 Solutions”
then click “Powerware pSeries” or “Powerware iSeries”
Materials available Data sheet Application overview chart Product presentation Documents (manuals) Communication Options for IBM Applications