Information Flexible Multiplexer FMX2R3.2 UMN:TED A50010-A3-C701-1-7618

Transcript of Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible...

Page 1: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

Information

Flexible Multiplexer FMX2R3.2

UMN:TED

A50010-A3-C701-1-7618

Page 2: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

2 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of theparts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in prop-erty damage.

Therefore, only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950-1 / IEC 60950-1. All equipment connected has tocomply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teilekönnen auch eine hohe Betriebstemperatur aufweisen.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen undSachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert undwartet.

Das System entspricht den Anforderungen der EN 60950-1 / IEC 60950-1. Angeschlossene Gerätemüssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Trademarks:

All designations used in this document can be trademarks, the use of which by third parties for theirown purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2005.

Issued by the Communications GroupHofmannstraße 51D-81359 München

Technical modifications possible.Technical specifications and features are binding only insofar asthey are specifically and expressly agreed upon in a written contract.

Page 3: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 3

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Reason for Update

Details: First issue

Chapter/Section Reason for Update

Issue HistoryIssue Date of issue Reason for Update

Page 4: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

4 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

This document consists of a total of 382 pages. All pages are issue 1.

Contents

1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.1 Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171.2 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.3 Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181.4 Protection Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191.4.1 Protection Against Excessive High Contact Voltages . . . . . . . . . . . . . . . . . 191.4.2 Protection Against Escaping Laser Light . . . . . . . . . . . . . . . . . . . . . . . . . . . 191.4.3 Protection Against Fire in Racks or Housings . . . . . . . . . . . . . . . . . . . . . . . 201.4.4 Components Subject to Electrostatic Discharge . . . . . . . . . . . . . . . . . . . . . 201.4.5 Handling Modules (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.4.6 Handling Optical Fiber Connectors and Cables . . . . . . . . . . . . . . . . . . . . . . 211.4.7 Protection against Foreign Voltages in the System . . . . . . . . . . . . . . . . . . . 211.4.8 Virus Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.5 CE Declaration of Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.6 Environmental Passport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

2 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.2 System Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.2.2 Central Unit CUD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.2.3 Bus Extension Card BEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.2.4 Units for Operation and Supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302.2.5 Line Cards for Analog Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.2.6 Line Cards for ISDN Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332.2.7 Line Cards for Digital Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372.3 External Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392.4 Internal Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

3 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.1 SNUS Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.1.1 Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.1.2 Internal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463.1.3 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473.1.4 QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483.1.5 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483.1.6 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493.1.7 Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503.1.8 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523.1.9 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623.2 FMX2S Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633.2.1 Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643.2.2 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 653.2.3 QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Page 5: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 5

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.2.4 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673.2.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673.2.6 Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683.2.7 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803.2.8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 913.3 MXS19C Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 933.3.1 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 933.3.2 Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 953.3.3 E1 Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 963.3.4 Line Termination Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 963.3.5 Elektro Magnetic Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 973.3.6 Taktsynchronisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 973.3.7 QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 983.3.8 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1003.3.9 Alarming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1013.3.10 Stromversorgung und Verlustleistung des Einsatzes . . . . . . . . . . . . . . . . 1013.3.11 Front Panels for Data Interfaces of the CPF2. . . . . . . . . . . . . . . . . . . . . . 1023.3.12 Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1033.3.13 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1043.3.14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1133.4 ONU 30 FTTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1143.4.1 Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1143.4.2 Shelf AMXMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1163.4.3 Supervision Unit MSUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1183.4.4 Fan and Alarm Module FAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1233.4.5 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1253.4.6 Management Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1283.4.7 Front Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1283.4.8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1293.5 ONU 20 FTTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1323.5.1 Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1323.5.2 Configuration and Equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1343.5.3 Hardware Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1353.5.4 Terminal Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1383.5.5 Clock Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1483.5.6 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1483.5.7 Operating Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1493.5.8 Local Operation of the ONU 20 FTTO . . . . . . . . . . . . . . . . . . . . . . . . . . . 1493.5.9 Control and Supervision Unit COSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1493.5.10 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1533.6 CUD Central Unit Drop/Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1563.6.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1563.6.2 Monitoring and Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1573.6.3 Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1613.6.4 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1633.6.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1653.7 Bus Extension Unit BEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Page 6: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

6 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.7.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1683.7.2 Monitoring and Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1683.7.3 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1693.7.4 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1703.7.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1713.8 SUB102 Subscriber Converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1723.8.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1723.8.2 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1733.8.3 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1743.9 SLX102 and SLX102E Subscriber Converters . . . . . . . . . . . . . . . . . . . . . 1773.9.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1773.9.2 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1783.9.3 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1793.10 SLB62 Subscriber Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1813.10.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1813.10.2 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1823.10.3 Monitoring and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1823.10.4 Connector Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1833.10.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1843.11 UAC68 Universal Analog Line Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1863.11.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1863.11.2 Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1883.11.3 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1883.11.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1913.12 SEM106C E&M Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1933.12.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1933.12.2 Monitoring and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1943.12.3 Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1943.12.4 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1953.12.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1963.13 SEM108HC E&M Converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1983.13.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1983.13.2 Monitoring and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993.13.3 Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1993.13.4 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2003.13.5 Signal Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2013.13.6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2013.14 Analog Leased Line LLA102/104C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2033.14.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2033.14.2 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2033.14.3 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2043.14.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2053.15 ISDN I8S0P Line Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2073.15.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2073.15.2 Time Slot Allocation and Signaling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2083.15.3 Supervision and Alarm Signaling and Diagnostics. . . . . . . . . . . . . . . . . . . 2093.15.4 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

Page 7: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 7

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.15.5 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2113.15.6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2123.16 IUL82C and IUL84C ISDN Line Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . 2143.16.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2143.16.2 Time Slot Allocation and Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2153.16.3 Supervision and Alarm Signaling and Diagnostics . . . . . . . . . . . . . . . . . . 2153.16.4 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2163.16.5 Technical Data IUL82C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2173.16.6 Technical Data IUL84C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2193.17 I4UK2NTP/I4UK4NTP ISDN Line Cards. . . . . . . . . . . . . . . . . . . . . . . . . . 2213.17.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2213.17.2 Time Slot Assignment and Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2213.17.3 Connector Assignment of I4UK2NTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2233.17.4 Connector Assignment of the I4UK4NTP . . . . . . . . . . . . . . . . . . . . . . . . . 2253.17.5 Technical Data I4UK2NTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2263.17.6 Technical Data I4UK4NTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2273.18 DSC104C Digital Signal Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2293.18.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2293.18.2 Point-to-Multipoint Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2293.18.3 Conference Modes of the Central Unit Drop/Insert, CUD . . . . . . . . . . . . . 2303.18.4 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2303.18.5 Supervision and Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2303.18.6 Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2313.18.7 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2323.18.8 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2333.18.9 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2343.19 DSC6-n×64C Digital Signal Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2353.19.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2353.19.2 Codirectional Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2353.19.3 Centralized Clock Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2363.19.4 Contradirectional Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2363.19.5 Point-to-Multipoint Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2363.19.6 Conference Modes of the Central Unit Drop/Insert, CUD . . . . . . . . . . . . . 2363.19.7 Test Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2363.19.8 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2373.19.9 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2383.20 CM64/2 Channel Multiplexer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2403.20.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2403.20.2 2-Mbit/s Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2413.20.3 Sa Bit Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2413.20.4 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2413.20.5 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2423.20.6 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2433.20.7 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2453.20.8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2463.21 CPF2 Digital Signal Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2483.21.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248

Page 8: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

8 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.21.2 Clock Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2493.21.3 Sub Bitrate Multiplexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2493.21.4 Point-to-Multipoint Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2503.21.5 Channel Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2503.21.6 Supervision and Diagnosis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2513.21.7 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2533.21.8 Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2543.21.9 Overview CIM Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2593.21.10 CIM-X.21 Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2603.21.11 CIM-V.24 Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2693.21.12 CIM-V.35 Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2783.21.13 CIM-V.36 Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2883.21.14 Schnittstellenmodul CIM-nx64E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2983.21.15 Technical Data CPF2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3033.22 Supervision Unit, SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3113.22.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3113.22.2 Control and Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3133.22.3 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3143.22.4 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3173.22.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3193.23 Supervision Unit, OSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3213.23.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3213.23.2 Supervision and Alarm Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3233.23.3 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3243.23.4 Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3263.23.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3283.24 SISA Concentrator SISAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3303.24.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3303.24.2 Control and Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3323.24.3 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3333.24.4 Terminal Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3353.24.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336

4 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3404.1 Operating Modes of the Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3404.1.1 Drop Insert Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3404.1.2 Terminal Multiplexer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3424.1.3 Terminal Multiplexer with 1+1 Protection Switching. . . . . . . . . . . . . . . . . . 3424.1.4 Ethernet Connection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3444.2 End-to-End Protection for Subrates and n × 64 kbit/s . . . . . . . . . . . . . . . . 3464.3 Timed Tasks for Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3484.4 Signaling of the ISDN Line Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3494.4.1 Dial-up Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3494.4.2 Leased Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3494.5 Clock Generation and Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . 350

5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3525.1 Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352

Page 9: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 9

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

5.2 SISA Communication Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3535.3 Access to Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3545.4 DCN Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3565.5 Management in an SDH Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3575.5.1 SDH Overhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3575.5.2 Access via the ECC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3595.5.3 DCN Decoupling via ECC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3605.5.4 Node in an SDH Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3655.6 Management in a Line Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3665.6.1 Access of the Network Management System . . . . . . . . . . . . . . . . . . . . . . 3665.6.2 DCN Decoupling via ECC in a Line Network . . . . . . . . . . . . . . . . . . . . . . 3675.6.3 DCN Decoupling in the FMX2S in the Line Network. . . . . . . . . . . . . . . . . 3675.7 DCN Structures with MXS19C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3685.7.1 ECC Channel (64 kbit/s or 9.6 kbit/s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3685.7.2 Overhead Channel (9.6 kbit/s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3695.8 Software Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3715.8.1 Memory Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3715.8.2 Data Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3725.9 Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373

6 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374

7 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379

Page 10: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

10 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

IllustrationsFig. 2.1 FMX2R3.2 Corporate Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Fig. 2.2 Ethernet Switching via an FMX2R3.2 Network . . . . . . . . . . . . . . . . . . . . 26

Fig. 2.3 Access via FMX2R3.2 Network to V5.1/V5.2 Exchange. . . . . . . . . . . . . 26

Fig. 2.4 Connecting the Network Termination Units to the Multiplexer . . . . . . . . 27

Fig. 2.5 Overview Circuit Diagram of Multiplexer. . . . . . . . . . . . . . . . . . . . . . . . . 30

Fig. 2.6 Subscriber Access to Digital Exchange . . . . . . . . . . . . . . . . . . . . . . . . . 31

Fig. 2.7 Subscriber Access to Analog Exchange . . . . . . . . . . . . . . . . . . . . . . . . . 31

Fig. 2.8 LLA102/104C in Leased Lines with 2-Wire Interface . . . . . . . . . . . . . . . 32

Fig. 2.9 LLA102/104C in Leased Lines with 4-Wire Interface . . . . . . . . . . . . . . . 32

Fig. 2.10 I8S0P Dial-up Connection with CAS Signaling . . . . . . . . . . . . . . . . . . . . 33

Fig. 2.11 I8S0P Dial-up Connection Using FA Signaling . . . . . . . . . . . . . . . . . . . . 33

Fig. 2.12 I8S0P Leased-line Connections Using FA Signaling . . . . . . . . . . . . . . . 34

Fig. 2.13 I8S0P Leased-line Connections for Stand-alone Operation . . . . . . . . . . 34

Fig. 2.14 Dial-up Connection of the IUL82C or IUL84C with CAS Signalingin Repeater Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Fig. 2.15 Dial-up Connection of the IUL84C with FA Signaling . . . . . . . . . . . . . . . 35

Fig. 2.16 Leased-Line Connections of the IUL84C with FA-Signaling . . . . . . . . . . 36

Fig. 2.17 Leased-Line Connections of the IUL82C in Stand-alone Mode . . . . . . . 36

Fig. 2.18 Leased-Line Connection of the IUL84C in Stand-alone Mode . . . . . . . . 36

Fig. 2.19 CPF2 Front Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Fig. 3.1 Use of FMX2R3.2 Multiplexer in an SNU Shelf (Example) . . . . . . . . . . . 42

Fig. 3.2 Shelf SNUS (without Front Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Fig. 3.3 SNUS Equipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Fig. 3.4 SNUS Internal 2-Mbit/s Connections, Subrack fitted with SMX1/4c . . . . 46

Fig. 3.5 SNUS Internal Wiring of PCI Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . 46

Fig. 3.6 SNUS Internal 34-Mbit/s and STM-1 Connections . . . . . . . . . . . . . . . . . 47

Fig. 3.7 SNUS Clock Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Fig. 3.8 SNUS QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Fig. 3.9 SNUS Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Fig. 3.10 SNUS Front View without Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Fig. 3.11 SNUS Connector Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Fig. 3.12 Shelf FMX2S (without Front Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Fig. 3.13 FMX2S Equipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Fig. 3.14 FMX2S Clock Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Fig. 3.15 FMX2S QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Fig. 3.16 FMX2S Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Fig. 3.17 FMX2S Front View without Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . 68

Fig. 3.18 Shelf MXS19C with Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Fig. 3.19 MXS19C Front View without Front Cover, Unequipped . . . . . . . . . . . . . 94

Fig. 3.20 MXS19C Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

Fig. 3.21 MXS19C Equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Fig. 3.22 External Interfaces of the Line Termination Units . . . . . . . . . . . . . . . . . . 96

Fig. 3.23 MXS19C Clock Distribution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

Page 11: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 11

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Fig. 3.24 MXS19C QD2 Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Fig. 3.25 QD2 Bus Switch-over. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Fig. 3.26 Connecting Cable S42023-A799-S18 . . . . . . . . . . . . . . . . . . . . . . . . . 102

Fig. 3.27 MXS19C Backplane, Shelf from Inside . . . . . . . . . . . . . . . . . . . . . . . . 103

Fig. 3.28 Structure of ONU 30 FTTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Fig. 3.29 Front View of ONU 30 FTTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Fig. 3.30 ONU 30 FTTB Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

Fig. 3.31 Equipping of the AMXMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

Fig. 3.32 Control Elements of the MSUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Fig. 3.33 MSUE Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

Fig. 3.34 SV 65 W 12 V/48 V, Front View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126

Fig. 3.35 Switching from 230 V to 115 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

Fig. 3.36 Management Access to the ONU 30 FTTB . . . . . . . . . . . . . . . . . . . . . 128

Fig. 3.37 Use of FMX2R3.2 Multiplexer in an ONU 20 FTTO (Example) . . . . . . 132

Fig. 3.38 Front View of the ONU 20 FTTO (with and without Front Plate) . . . . . 132

Fig. 3.39 Structure of ONU 20 FTTO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

Fig. 3.40 ONU 20 FTTO with Power Supply and Backup Battery. . . . . . . . . . . . 133

Fig. 3.41 Configuration of the 2-Mbit/s Interfaces of ONU 20 FTTO. . . . . . . . . . 134

Fig. 3.42 ONU 20 Equipping and Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

Fig. 3.43 Rear Side of the ONU 20 FTTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

Fig. 3.44 Switches and Connectors in the ONU 20 FTTO . . . . . . . . . . . . . . . . . 136

Fig. 3.45 Connecting Cable S42022-A768-S56 . . . . . . . . . . . . . . . . . . . . . . . . . 144

Fig. 3.46 Battery Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

Fig. 3.47 Supervision Unit COSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

Fig. 3.48 Controls of the CUD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Fig. 3.49 Connector Assignment of the CUD . . . . . . . . . . . . . . . . . . . . . . . . . . . 163

Fig. 3.50 Controls of the BEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169

Fig. 3.51 Connector Assignment BEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170

Fig. 3.52 Connector Assignment of SUB102 . . . . . . . . . . . . . . . . . . . . . . . . . . . 173

Fig. 3.53 Connector Assignment of the SLX102/E . . . . . . . . . . . . . . . . . . . . . . 178

Fig. 3.54 Controls of the SLB62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

Fig. 3.55 Connector Assignment of the SLB62. . . . . . . . . . . . . . . . . . . . . . . . . . 183

Fig. 3.56 Internal Sin Interface Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187

Fig. 3.57 Internal Interface Circuit of S2in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

Fig. 3.58 Connector Assignment of the SEM106C . . . . . . . . . . . . . . . . . . . . . . . 195

Fig. 3.59 Internal Interface Circuit of S2in. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

Fig. 3.60 Connector Assignment SEM108HC. . . . . . . . . . . . . . . . . . . . . . . . . . . 200

Fig. 3.61 Connector Assignment of LLA102/104C . . . . . . . . . . . . . . . . . . . . . . . 204

Fig. 3.62 Loops on the I8S0P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209

Fig. 3.63 Control Elements of the I8S0P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

Fig. 3.64 Connector Assignment of I8S0P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

Fig. 3.65 Connector Assignment of IUL82C and IUL84C . . . . . . . . . . . . . . . . . . 216

Fig. 3.66 Connector Assignment of I4UK2NTP . . . . . . . . . . . . . . . . . . . . . . . . . 223

Fig. 3.67 Connector Assignment of the I4UK4NTP . . . . . . . . . . . . . . . . . . . . . . 225

Page 12: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

12 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Fig. 3.68 Controls of the DSC104C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231

Fig. 3.69 Connector Assignment of the DSC104C . . . . . . . . . . . . . . . . . . . . . . . 232

Fig. 3.70 Connector Assignment of DSC6-nx64C . . . . . . . . . . . . . . . . . . . . . . . 237

Fig. 3.71 Controls of the CM64/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243

Fig. 3.72 Connector Assignment of the Jacks 20, 21 and 22 . . . . . . . . . . . . . . . 244

Fig. 3.73 Connector Assignment of the CM64/2 . . . . . . . . . . . . . . . . . . . . . . . . . 245

Fig. 3.74 Controls of the CPF2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253

Fig. 3.75 Controls of the X.21 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268

Fig. 3.76 Controls of the V.24 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277

Fig. 3.77 Controls of the V.35 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284

Fig. 3.78 Controls of the V.36 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296

Fig. 3.79 Übersichtsschaltplan CIM-nx64E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

Fig. 3.80 Controls Ethernet Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

Fig. 3.81 Operation and Monitoring via the SUE’s QD2-Interface . . . . . . . . . . . . 311

Fig. 3.82 Controls of the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314

Fig. 3.83 Connector 11 of the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317

Fig. 3.84 Connector 10 of the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318

Fig. 3.85 Operation of the System Modules with OSU (Example) . . . . . . . . . . . . 321

Fig. 3.86 Application of QD2 Master Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323

Fig. 3.87 Controls of the OSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324

Fig. 3.88 Connector of the OSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326

Fig. 3.89 Controls of the SISAK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333

Fig. 3.90 Contact Assignment of the F Connector . . . . . . . . . . . . . . . . . . . . . . . . 334

Fig. 3.91 Terminal Assignment of the SISAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . 335

Fig. 4.1 Connecting a 2-Mbit/s Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340

Fig. 4.2 Tapping off and Inserting 64-kbit/s Signals. . . . . . . . . . . . . . . . . . . . . . 340

Fig. 4.3 Digital Conference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341

Fig. 4.4 Point (Port E1A)-to-Multipoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341

Fig. 4.5 Point (Port E1B)-to-Multipoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341

Fig. 4.6 Point (Time Slot)-to-Multipoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341

Fig. 4.7 Broadcasting with E1A as Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342

Fig. 4.8 Broadcasting with E1B as Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342

Fig. 4.9 Broadcasting with Time Slot as Point . . . . . . . . . . . . . . . . . . . . . . . . . . 342

Fig. 4.10 Terminal Multiplexer TMX30(1+1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343

Fig. 4.11 Ethernet Traffic in Different Timeslot Groups . . . . . . . . . . . . . . . . . . . . 344

Fig. 4.12 Ethernet Traffic of 2 Timeslot Groups . . . . . . . . . . . . . . . . . . . . . . . . . . 345

Fig. 4.13 Ethernet Traffic in Star Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 345

Fig. 4.14 End-to-end Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346

Fig. 4.15 Actions for Channel Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347

Fig. 4.16 CAS Signaling on ISDN Dial-up Lines . . . . . . . . . . . . . . . . . . . . . . . . . 349

Fig. 4.17 FA Signaling on ISDN Dial-up Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . 349

Fig. 4.18 Stand-alone Operation with D Channel Signaling. . . . . . . . . . . . . . . . . 349

Fig. 4.19 FA Signaling in ISDN Leased Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . 349

Fig. 4.20 Clock Control in Linear Network (T3 Available at both End Points) . . . 350

Page 13: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 13

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Fig. 5.1 Network Management of FMX2R3.2 (Example) . . . . . . . . . . . . . . . . . 352

Fig. 5.2 SISA Structure of FMX2R3.2 Network. . . . . . . . . . . . . . . . . . . . . . . . . 353

Fig. 5.3 Example of a FMX2R3 Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354

Fig. 5.4 Operation of System Modules in Standalone Operationof SNUS (Example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355

Fig. 5.5 DCN Transport via Overhead in an SDH Ring withOne Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358

Fig. 5.6 DCN Transport via Overhead in an SDH Ring withTwo Management Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359

Fig. 5.7 DCN Access via ECC in an SDH Ringwith One Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359

Fig. 5.8 DCN Access via ECC in an SDH Ring withRedundant Transmission Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360

Fig. 5.9 DCN Access via ECC in an SDH Ringwith Two Management Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360

Fig. 5.10 DCN Decoupling via ECC in an SDH Ring . . . . . . . . . . . . . . . . . . . . . 361

Fig. 5.11 DCN Decoupling via ECC in an SDH Ringwith Two Management Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361

Fig. 5.12 DCN Decoupling via ECC in an SDH Ringwith Redundant Transmission Path . . . . . . . . . . . . . . . . . . . . . . . . . . . 362

Fig. 5.13 DCN Decoupling via ECC in an SDH Ringwith Branch to Line Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363

Fig. 5.14 DCN Decoupling via ECC in an SDH Ring withBranch to Line Networks, Two Management Systems . . . . . . . . . . . . 364

Fig. 5.15 DCN Decoupling via ECC in an SDH Ringat the Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365

Fig. 5.16 DCN Access via ECC in a Line Networkwith DCN Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366

Fig. 5.17 DCN Access via ECC in a Line Network withTwo Management Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366

Fig. 5.18 DCN Decoupling via ECC in a Line Networkor Star Network with Two Management Systems . . . . . . . . . . . . . . . . 367

Fig. 5.19 ECC Channel (64 kbit/s or 9.6 kbit/s). . . . . . . . . . . . . . . . . . . . . . . . . . 368

Fig. 5.20 ECC in the Central Station. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368

Fig. 5.21 ECC in the Line Network and in the Remote Station . . . . . . . . . . . . . . 369

Fig. 5.22 Overhead Channel (9.6 kbit/s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369

Fig. 5.23 Overhead Channel in the Central Station . . . . . . . . . . . . . . . . . . . . . . 370

Fig. 5.24 Overhead Channel in the Line Network . . . . . . . . . . . . . . . . . . . . . . . . 370

Fig. 5.25 Overhead Channel in the Remote Station . . . . . . . . . . . . . . . . . . . . . . 371

Fig. 5.26 Software Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373

Page 14: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

14 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

TablesTab. 1.1 Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Tab. 2.1 Interface Modules for Use on the CPF2 . . . . . . . . . . . . . . . . . . . . . . . . . 37

Tab. 2.2 CPF2 Front Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Tab. 3.1 SNUS FMX2R3.2 and LTx Equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Tab. 3.2 SNUS CMXC Equipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Tab. 3.3 SNUS SMX1/4c Equipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Tab. 3.4 SNUS DIL Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Tab. 3.5 SNUS Units and Addressing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Tab. 3.6 SNUS Connectors X141 and X142. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Tab. 3.7 SNUS 15-Contact Jacks X101, X102 and X121 . . . . . . . . . . . . . . . . . . . 53

Tab. 3.8 SNUS 9-Contact Jacks X120, X143 and X144 . . . . . . . . . . . . . . . . . . . . 54

Tab. 3.9 SNUS Connectors X122, X131, X138, X112 and X132 . . . . . . . . . . . . . 55

Tab. 3.10 SNUS Connectors X103 to X108, X123 to X128,X103, X123, X107, X108 and X111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Tab. 3.11 SNUS Connectors X109, X110, X 113, X114, X129,X130, X133, X134. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Tab. 3.12 SNUS Connectors X115 to X117, X135 to X137 . . . . . . . . . . . . . . . . . . 58

Tab. 3.13 SNUS Connectors X103 to X108, X123 to X128 (Part 1) . . . . . . . . . . . . 59

Tab. 3.14 SNUS Connectors X103 to X108, X123 to X128 (Part 2) . . . . . . . . . . . . 60

Tab. 3.15 SNUS Connectors X103 to X108, X123 to X128 (Part 3) . . . . . . . . . . . . 61

Tab. 3.16 FMX2S Equipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Tab. 3.17 FMX2S Overview of the Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Tab. 3.18 FMX2S Address Settings for the Units . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Tab. 3.19 FMX2S LC Connectors (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Tab. 3.20 FMX2S Connectors X105 to X110, X113 to X118 (Part 1) . . . . . . . . . . . 81

Tab. 3.21 FMX2S Connectors X105 to X110, X113 to X118 (Part 2) . . . . . . . . . . . 82

Tab. 3.22 FMX2S Connectors X105 to X110, X113 to X118 (Part 3) . . . . . . . . . . . 83

Tab. 3.23 FMX2S Connectors X123 to X128, X131 to X136 (Part 1) . . . . . . . . . . . 84

Tab. 3.24 FMX2S Connectors X123 to X128, X131 to X136 (Part 2) . . . . . . . . . . . 85

Tab. 3.25 FMX2S Connectors X123 to X128, X131 to X136 (Part 3) . . . . . . . . . . . 86

Tab. 3.26 FMX2S Connectors X101 to X104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Tab. 3.27 FMX2S Connectors X119 to X121 and X138 . . . . . . . . . . . . . . . . . . . . . 88

Tab. 3.28 FMX2S Connectors X139 and X140. . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

Tab. 3.29 FMX2S Connectors X111, X112, X129 and X130 . . . . . . . . . . . . . . . . . 90

Tab. 3.30 FMX2S Connector X137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Tab. 3.31 FMX2S Connectors X141 and X142. . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Tab. 3.32 MXS19C Equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Tab. 3.33 Minimization of EMC Disturbances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Tab. 3.34 MXS19C Plug-in Units and Addresses . . . . . . . . . . . . . . . . . . . . . . . . . 100

Tab. 3.35 MXS19C Connector Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

Tab. 3.36 MXS19C Steckverbinder X101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Tab. 3.37 MXS19C Connector X103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Tab. 3.38 MXS19C Connectors X104 to X109, X112 to X117 (General) . . . . . . . 107

Page 15: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 15

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Tab. 3.39 MXS19C Connectors X104 to X109, X112 to X117, Part 1 . . . . . . . . . 108

Tab. 3.40 MXS19C Connectors X104 to X109, X112 to X117, Part 2 . . . . . . . . . 109

Tab. 3.41 MXS19C , Connectors X104 to X109, X112 to X117, Part 3 . . . . . . . . 110

Tab. 3.42 MXS19C Connectors X110 and X111 . . . . . . . . . . . . . . . . . . . . . . . . . 111

Tab. 3.43 MXS19C Connector X118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

Tab. 3.44 MXS19C Connector X120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113

Tab. 3.45 AMXMS Equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Tab. 3.46 Visual Signalizing of the MSUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

Tab. 3.47 ONU 30 FTTB External Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

Tab. 3.48 FAM Connector X1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

Tab. 3.49 LED Displays on SV 65 W 12 V/48 V . . . . . . . . . . . . . . . . . . . . . . . . . 127

Tab. 3.50 Equipping the ONU 20 FTTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

Tab. 3.51 DIL Switch Setting in the Central Terminal Panel . . . . . . . . . . . . . . . . 137

Tab. 3.52 Central Terminal Panels on the ONU 20 FTTO. . . . . . . . . . . . . . . . . . 138

Tab. 3.53 Terminal Panels of Line Cards in ONU 20 FTTO . . . . . . . . . . . . . . . . 138

Tab. 3.54 Optical Signalling of the COSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151

Tab. 3.55 Setting the DIL Switch S2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

Tab. 3.56 Table of Alarms of the CUD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157

Tab. 3.57 Optical Signaling of the CUD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

Tab. 3.58 Setting the Controls of the CUD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Tab. 3.59 Address Switch Settings on the CUD . . . . . . . . . . . . . . . . . . . . . . . . . 162

Tab. 3.60 SLX102/E Plug-in Unit Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180

Tab. 3.61 Table of Alarms of the SLB62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

Tab. 3.62 System Connector of the UAC68 (Internal Interface) . . . . . . . . . . . . . 188

Tab. 3.63 Exchange Connector of the UAC68 (External Interface) . . . . . . . . . . . 189

Tab. 3.64 Table of Alarms for the SEM106C . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

Tab. 3.65 Table of Alarms for the SEM108HC. . . . . . . . . . . . . . . . . . . . . . . . . . . 199

Tab. 3.66 Controls on the I8S0P (S0-Bus). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

Tab. 3.67 Restricted Time Slot Occupancy of the I4UK2NTP at 128 kbit/s . . . . . 222

Tab. 3.68 Restricted Time Slot Occupancy of the I4UK4NTP at 128 kbit/s . . . . . 222

Tab. 3.69 Table of Alarms for the DSC104C . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233

Tab. 3.70 Table of Alarms of the CM64/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242

Tab. 3.71 Controls of the CM64/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244

Tab. 3.72 Interface Modules for Use on the CPF2. . . . . . . . . . . . . . . . . . . . . . . . 248

Tab. 3.73 Assignment of the LEDs to the Ports of the Unit . . . . . . . . . . . . . . . . . 251

Tab. 3.74 LED Control when the Alarm Occurs . . . . . . . . . . . . . . . . . . . . . . . . . . 251

Tab. 3.75 Connector Assignment X15 of the CPF2. . . . . . . . . . . . . . . . . . . . . . . 254

Tab. 3.76 Terminal Assignment X16 (General) of the CPF2 . . . . . . . . . . . . . . . . 255

Tab. 3.77 Connector Assignment X16 (for X.21-Modules) of the CPF2 . . . . . . . 256

Tab. 3.78 CPF2 Connector X16 (with CIM-nx64E Modules) . . . . . . . . . . . . . . . . 257

Tab. 3.79 Relationship between Number of Bits and Transmission Speed . . . . . 260

Tab. 3.80 Signal States at the X.21 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 263

Tab. 3.81 Alarm Table CPF2 with X.21 Module. . . . . . . . . . . . . . . . . . . . . . . . . . 264

Tab. 3.82 Interface Signals X.21 at the Module Connector . . . . . . . . . . . . . . . . . 268

Page 16: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

16 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Tab. 3.83 Terminal Assignment of the X.21 Module Connector . . . . . . . . . . . . . . 269

Tab. 3.84 Signal States at the V interface, Part 1(not for V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

Tab. 3.85 Signal States at the V Interface, Part 2(V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273

Tab. 3.86 Alarm Table CPF2 with V.24 Module . . . . . . . . . . . . . . . . . . . . . . . . . . 274

Tab. 3.87 V.24 Interface Signals at the Module Connector . . . . . . . . . . . . . . . . . 277

Tab. 3.88 Terminal Assignment of the V.24 Module Connector . . . . . . . . . . . . . . 278

Tab. 3.89 Signal States at the V Interface, Part 1(not for V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282

Tab. 3.90 Signal States at the V Interface, Part 2( V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283

Tab. 3.91 Alarm Table CPF2 with V.35 Module . . . . . . . . . . . . . . . . . . . . . . . . . . 284

Tab. 3.92 V.35 Interface Signals at the Module Connector . . . . . . . . . . . . . . . . . 285

Tab. 3.93 Terminal Assignment of the V.35 Module Connector . . . . . . . . . . . . . . 285

Tab. 3.94 Signal States at the V Interface, Part 1(not for V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291

Tab. 3.95 Signal States at the V Interface, Part 2(V.110 protocol operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292

Tab. 3.96 Alarm Table CPF2 with V.36 Module . . . . . . . . . . . . . . . . . . . . . . . . . . 293

Tab. 3.97 V.36 Interface Signals at the Module Connector . . . . . . . . . . . . . . . . . 296

Tab. 3.98 Terminal Assignment of the V.36 Module Connector . . . . . . . . . . . . . . 297

Tab. 3.99 CIM-nx64E Module Connector X1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

Tab. 3.100 CIM-nx64E Module Connector X2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

Tab. 3.101 Visual Signals Output by the SUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313

Tab. 3.102 LED Displays of OSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323

Tab. 3.103 As-delivered State of the Interfaces of the OSU . . . . . . . . . . . . . . . . . . 324

Tab. 3.104 DIL Switch on the OSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325

Tab. 3.105 DIL Switch on the OSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325

Tab. 3.106 SISAK Transmission Channels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330

Tab. 3.107 SISAK Input and Output Stages for the Data Channelsand Clock Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330

Tab. 3.108 Interfaces and Bit Rates at the SISAK’s Slave Ports . . . . . . . . . . . . . . 331

Tab. 3.109 Interfaces and Bit Rates at the SISAK’s Master Port . . . . . . . . . . . . . . 332

Tab. 3.110 Settings by Control Elements of the SISAK . . . . . . . . . . . . . . . . . . . . . 333

Tab. 3.111 Optical Signalling of the SISAK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334

Tab. 4.1 Priorities of Alarm Criteria for Protection Switching . . . . . . . . . . . . . . . 343

Tab. 4.2 Functions with Channel Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346

Tab. 5.1 DCN Channels for Remote Operation of the FMX2R3.2 . . . . . . . . . . . 356

Page 17: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 17

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

1 General InformationThis manual, an overview about the components and their interworking in networks withthe multiplexer FMX2R3.2 is given. Functions, commissioning, operation and mainte-nance of FMX2R3.2 are described in detail. The operation is done via the graphical userinterface of the AccessIntegrator domain manager version 8.2 (ACI DM V8.2) or higherversions. For the ACI DM V8.2, there is a separate documentation available (see Sec-tion 1.3).

1.1 Structure of the ManualThe manual consists of the following Registers:• Information• Installation• Commissioning• Operation• Maintenance.

Information The register Information (UMN:TED) gives a general overview about applications andthe structure of the FMX2R3.2 and its components. Shelves, ONUs (Optical NetworkUnits) and plug-in units of FMX2R3.2 are described in detail, including technical data,controls and connector assignment. At the end of the document there is a completeproduct overview of all components, which can be plugged in the shelves or ONUs ofthe FMX2R3.2.

Installation The FMX2R3.2 shelves are offered stand alone. They can be mounted in ETSI- or 19’’-racks or shelters. The ONUs are compact devices, which can be mounted at the wall.The necessary information for that are contained in the register Installation (UMN:IMN).

Commissioning The register Commissioning (UMN:ITMN) describes all the procedures and measure-ments for activating the installed system, including step-by-step instructions to commis-sion the FMX2R3.2.

Operation FMX2R3.2 is operated via the graphical user interface of the ACI Domain Manager ver-sion 8.3 or higher, which is described in separat manuals, see Section 1.3. The registerOperation (UMN:OMN) offers a guide line to use the operating procedures for configur-ing the system and for creating connections.

Maintenance The procedures which expedite the re-establishment of normal operating state after amalfunction has occurred in the FMX2R3.2 can be find out via the operating system by“Branch to Maintenance”. The register Maintenance (UMN:MMN) gives an overview ofthe possible malfunctions and contains a guideline for using of the “Branch to Mainte-nance”.

Page 18: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

18 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

1.2 Typographical ConventionsIn all sections of this manual, the following conventions are applied:

1.3 Additional DocumentationIn addition, following documentation are used:• User Manual AccessIntegrator Domain Manager: UMN ACI DM TDM version V8.3,

SIEMENS Kit No. A50010-T3-A819• Depending on plugged components:

– Crossconnect Multiplexer CMXC: UMN CMXCSIEMENS Ordering No. A50010-A3-C800-*-7619

– 2-Mbit/s Line Terminating unit: UMN LE2 (FastLink)SIEMENS Ordering No. A50010-A3-K600-*-7619

– Synchronous Multiplexer SMX1/4c: UMN SMX1/4c (FastLink)SIEMENS Ordering No. A50010-A3-K19-*-7619

– Infrastructure: UMN Infrastructure (FastLink)SIEMENS Ordering No. Nr. A50010-A3-K419-*-7619

• Project (planning) documentation.

Style of Representation Meaning

Courier Inputs and outputs

Example: Enter LOCAL as the server name

Command not found

Italics Variables

Example: name can be up to eight letters long.

“Italics” Variables fin procedures and title bas

Example: “General NE Parameter. <Network Element#...>:CUC#...”

Boldface Special emphasis

Example: This name may not be deleted

“Quotation marks” Labels on the user interface (e.g. windows, menu items, buttons)

Example: Activate the “OK” button

Make a selection in the “File” menu.

<Courier> Key combinations

Example: <CTRL> <ALT>+<ESC>

→ Successive menu items

Example: “File” → “Close”

iAdditional items of information

!Warnings at critical points in the activity sequence

Tab. 1.1 Typographical Conventions

Page 19: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 19

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

1.4 Protection MeasuresThis Section contains a summary of the most important requirements with regard to pro-tection of people and equipment. It does not claim to be complete. The installation in-structions listed are shown in detail in the relevant Installation Manuals.

All assembly, installation, operation and repair work may only be undertaken by properlytrained and qualified personnel.In the event of any injury (e.g. burns and acid burns) being sustained, seek medical helpimmediately.

1.4.1 Protection Against Excessive High Contact VoltagesWhen handling the power supply or working on it, observe the safety measures de-scribed in the specifications of the European Norm EN 50110, part 1 and part 2 (Oper-ation of electrical Systems) and the valid national country specific standards.

Special warning labels on the shelves point to the dangers which can result from highcontact voltages when they are not grounded.

1.4.2 Protection Against Escaping Laser LightWhen working on optical modules, note the regulations covering radiation safety on la-ser light units (EN 60825).

Modules equipped with laser light units carry the laser symbol.The following points should be noted here:For operation in closed systems the laser light units comply with Laser class 1, and suchunits can be identified by a stick on label as well as by a warning label.

Laser symbol

Warning label

Page 20: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

20 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

To guard against any possible hazards, all optical transmitters are equipped with an au-tomatic laser shutdown circuit. This trips if an input signal is missing at the relevant op-tical receiver, e.g. if the connection is interrupted.

This preventive measure should also be followed to avoid any damage to health by mak-ing sure that escaping laser light is not directed towards the eye.

When breaking laser connections, the following procedure should be followed, despitethe presence of the laser shutdown circuit:• Pull out the plug-in unit about 5 cm• Disconnect optical fiber• Pull out unit completely.

1.4.3 Protection Against Fire in Racks or HousingsIf FMX2R3.2 shelves are used in housing, the shelves must be performed the conditionsfor a fire protection housing according to DIN EN 60950.

To comply with fire protection standards as defined in DIN EN 60950, a protective plate(C42165-A320-C285) must be fitted into the floor of ETS and 19-inch standard racks.The rack must also meet the requirements of a fire-resistant housing as defined inDIN EN 60950.

1.4.4 Components Subject to Electrostatic Discharge

When packing or unpacking, touching pulling or plugging plug-in units bearing the ESDsymbol, it is essential to wear a grounding bracelet, which should be grounded to a shel-ter or rack when working on it. This ensures that the units are not subject to electrostaticdischarge.

Under no circumstances should the printed conductors or components of modules betouched. Take hold of modules by the edge only.

Once they have been removed, modules must be placed in the conductive plasticsleeves intended for them, and kept or dispatched in the special boxes or transport cas-es bearing the ESD symbol.

In order to avoid further damage to defective modules, they should be treated with thesame degree of care as new ones.

Modules which are accommodated in a closed and intact housing are protected anyway.

European standard EN50082-1 provides information on the proper handling of compo-nents which are subject to electrostatic discharge.

!Note, the laser safety shutdown must be always activated.

ESDsymbol

!Slide-in units bearing this symbol are equipped with components subject to electrostaticdischarge, that is to say the relevant safety provisions must be adhered to.

Page 21: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 21

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

1.4.5 Handling Modules (General)When working with modules (slide-in units, power supply modules, subracks) the follow-ing points should be noted:• Existing ventilation equipment must not be changed. The sufficient air circulation

must not be obstructed.

• When changing power supply modules you must switch off the fuse at the ac powerconnection. Damaged power connection cables for ac power operated systems areto be replaced by special leads supplied by the manufacturer.

• All slide-in units except for power supply modules can be removed or inserted withthe power still applied. To remove and insert the units you should use the two leversfitted to the front of the unit. A type label is fixed to one of the two levers providinginformation on the hardware and software version of the unit.

• When inserting and removing subracks and when transporting them, take theirweight into consideration.

• Cables may never be disconnected by pulling on the cable. Disconnection/connec-tion may only be undertaken by pushing in/pulling out the connector involved.

1.4.6 Handling Optical Fiber Connectors and CablesOptical connectors are precision-made components and must be handled accordingly.To ensure faultless functioning, the following points must be observed:• The minimum bending radius for optical fibers is 30 mm!• Mechanical damage to the surfaces of optical connectors impairs transmission qual-

ity by higher attenuation.– For this reason, do not expose the connectors to impact and tensile load.– Always fit optical fiber connectors with protective caps to guard them against me-

chanical damage and contamination. The protective dust caps should only be re-moved immediately prior to installation.

– Once the protective dust caps have been removed, you must check the surfacesof the optical fiber connectors to ensure that they are clean, and clean them if nec-essary.For cleaning, the C42334-A380-A926 optical fiber cleaning tool or a clean, lint-free cellulose cloth or a chamois leather is suitable. Isopropyl alcohol can be usedas cleaning fluid.

1.4.7 Protection against Foreign Voltages in the SystemTwo-level foreign voltage protection for the outdoor user lines is provided within the en-tire system (shelf or ONU and subscriber ports on the slide-in units).

For outdoor user lines, 420-V gas tube arresters are recommended. These can be in-stalled in the MDF (Main Distribution Frame) of the ONU 30 FTTB or in an external MDFon the LSAs.

!Beware of rotating parts.

!Sufficient protection against foreign voltages for outdoor subscriber lines are only givenwhen appropriate protection elements are used.

Page 22: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

22 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

With the ONU 20 FTTO, the protection elements are implemented on the terminal panelof the line card, if the line card provides outdoor ports, see technical data of the con-cerned line card (see Section 3).

1.4.8 Virus Protection

Even when exchanging data via network or external data carries (e.g. floppy disks) thereis a possibility of infecting your system with a virus. The occurrence of a virus in yoursystem may lead to a loss of data and breakdown of functionality.

You have to do the following task:• You have to check every data carrier (used data carriers as well as new ones) for

virus before reading data from it.• You must ensure that a current valid virus scanning program is always available. This

program has to be supplied with regular updates by a certified software.• It is recommended to make period checks against viruses in your OS.• At the LCT it is recommended to integrate the virus scanning program into the start-

up sequence.

1.5 CE Declaration of ConformityThe CE conformity of the product will be given if the construction and cabling is under-taken in accordance with the manual and the documents listed there in, e.g. mountinginstructions, cable lists. Where necessary account should be taken of project-specificdocuments.

Deviations from the specifications or unstipulated changes during construction, e.g. theuse of cable types with lower screening values can lead to violation of the CE require-ments. In such case the conformity declaration is invalidated and the responsibility pass-es to those who have caused the deviations.

1.6 Environmental PassportThe aim of this environmental passport is to provide you with the most important envi-ronmentally-relevant information for this product. This means you can be sure that youhave selected a supplier who develops, produces, packs and ships their products in anenvironmentally-compatible way.

Product origination process

Even at the product origination stage we pursue the aim of minimizing the adverse ef-fects on the environment:• We systematically record all product-related environmental requirements and take

account of these both in the product definition and in its development.• Protecting the environment is a matter of course in our day-to-day work. This in-

cludes minimizing the consumption of paper by using the latest technologies (e.g.

!To prevent a virus infection you may not use any software other than that which is re-leased for Operating System (TMN-OS based on Basis AccessIntegrator), Local CraftTerminal (LCT) and transmission system.

!The operator is responsible for protecting against viruses, and for carrying out repairprocedures when the system is infected.

Page 23: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 23

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Internet, e-mail, database, 4:1 paper printouts) as well as multi-separation, heat in-sulation and intelligent use of energy.

• We coordinate all environmental activities via a certified environmental manage-ment system which complies with ISO 14001. It is checked in accordance with theGerman certification body DQS (Deutsche Gesellschaft für Zertifizierung von Man-agementsystemen mbH), quality and environment assessors. Certificate registra-tion No.: 66749-01.

Naturally we at Siemens are conscious of the fact that expenditure for environmentalprotection measures must be kept within an economically justifiable framework. After all,we still want to offer you this product with a price/performance ratio which is attractive.

Manufacturing

Production facilities are equipped with the very latest, environmentally-friendly produc-tion machinery. Because of their minimal adverse effects on the environment theseplants can be operated without the need for special permits or notification. However theappropriate measures for reducing emissions are still taken in accordance with the stateof the art:• Solder systems with condensate traps minimize both the deposition of solvents at

the workstation and emissions into the atmosphere• Our manufacturing processes are completely free of CFCs, volatile CHCs (chlorinat-

ed solvents) and toxic substances.• The heat generated from producing compressed air will be used for heating walkable

floor surfaces.• Module production is practically waste-water-free since the use of low-residue fluxes

obviates the need for cleaning processes.• Far more than three quarters of all production waste is fed back into the secondary

resources cycle. Only 0.5% of the production waste has to be disposed of as specialwaste.

Transport/shipping

The systems made by our company are shipped exclusively in environmentally-friendlypackaging:• pesticide-free wooden packing cases, collapsible, reusable• Cardboard boxes• Filling/stuffing: air cushions with polyethylene envelope• “The Green Dot“ symbol for all packing for private end customers as a sign of our

involvement in Germany’s dual system.

Energy consumption

Our products are designed in consideration to reduce the energy consumption withoutaffecting the normal features (number of channels, techn. refinements etc.).

Power-down circuits also reduce energy consumption.

Taking back the product

Currently it is only possible to take back products when this has been regulated by priorcontract agreements.

Waste disposal

Basically the systems from Siemens Wireline Access Networks are produced withoutany hazardous or forbidden substances such Cadmium, PCBs, CFCs or such like. Once

Page 24: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

24 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

this product has reached the end of its useful life, it can be fraction separated and dis-posed of without hesitation in accordance with the current state of the art.

List of materials:• Casing: Aluminum, steel, ABS plastic (flame-resistant)

Surface coating only when this is required by the customer.• Modules: Normal electronic components (disposal as

“electronic waste”). The board material contains brominatedflame retardants. The following are to be disposed ofseparately: Electrolytic capacitors, LCDs and mechanicalcomponents (heat sinks)

• Cable Copper• Connectors: Gold, plastic• Batteries: Lead-acid batteries, SW-controlled charge and discharge cycles

considerably extend the life of today’s lead acid batteries.

Special features of specific components are listed in the enclosed dismantling guide.

All information is provided on a voluntary basis and far exceeds that required by law.Should you have any other questions about our quality and environmental management,please send an e-mail to the following address:[email protected]

Siemens AG, 2002

ICN Wireline Access Networks

Munich/Greifswald

Page 25: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 25

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

2 System Description

2.1 ApplicationThe flexible multiplexer FMX2R3.2 is a PCM30 system for building and extending flexi-ble networks, and is suitable for linear, cascade and ring structures. It is intended mainlyfor use in corporate networks, but can also be used for subscriber-side termination of aV5.1/V5.2 access network.

Companies and administrations like railway operators and utilities operate corporatenetworks along oil or gas pipelines, railway tracks and radio links, which are used formonitoring and maintenance purposes. Due to the ongoing worldwide success of theEthernet technology more and more control engineering components have been intro-duced with an Ethernet interface. FMX2R3.2 offers the possibility to use data interfacesbased on Ethernet technology.

The FMX2R3.2 operates as terminal or drop/insert multiplexer for the following services:• POTS, POTS with local battery• ISDN-BA (S0, Uk0 with line code 4B3T or 2B1Q), also semipermanent• Analog 2/4- wire transmission as leased lines or with E&M signaling• V.24/V.35/V.36/RS530 and X.21 data transmission with subrates up to

30/31 × 64 kbit/s, G.703 with 30/31 × 64 kbit/s• Data transmission with up to 30/31 × 64 kbit/s via Ethernet 10/100Base-T.

The features and properties of the multiplexer correspond to ITU-T RecommendationG.797. In the transmission network direction, it implements up to two 2-Mbit/s interfacesaccording to ITU-T G.703/9. The signaling codes are transmitted using CAS (ChannelAssociated Signaling). As a special signaling variant, FA signaling is also available.

Essential tasks of the multiplexer are:• Multiplexing functions for speech and data signals.• Provision of appropriate subscriber interfaces• Control of subscriber interfaces with CAS or FA signaling.

The CAS code frame corresponds to ITU-T Recommendation G.704/5.1.3.

Fig. 2.1 displays an example for an FMX2R3.2 corporate network:

Fig. 2.1 FMX2R3.2 Corporate Network

FMX2R3.2

FMX2R3.2

Subs.

2 Mbit/sG.703

CAS, FA, LL

FMX2R3.2

Subs.

2 Mbit/sG.703

FMX2R3.2

Subs.

FMX2R3.2

FMX2R3.2

Subs.

Subs.

PBX ComputerCenter

FMX2R3.2Subs.

FMX2R3.2Subs.FMX2R3.2

Subs.

STM-1/STM-4

Page 26: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

26 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Fig. 2.2 shows the typical application scenario, if FMX2R3.2 is used for monitoring andcontrolling along an oil pipeline. The FMX2R3.2 elements along the pipeline provideEthernet interfaces for data transport between Ethernet based sensors, valves or similarand the maintenance centre.

The Ethernet interfaces alway work in mirror mode. The Ethernet traffic from the sensorsis mapped into n x 64 kbit/s timeslots of an E1 link and transported to the next FMX2R3.2station. The Ethernet interfaces of all sensors of the same FMX2R3.2 station and addi-tionally all FMX2R3.2 stations along the pipeline operate together with their distant ter-minal in the centre as distributed L2 Ethernet switch. This is necessary becausemapping of Ethernet traffic of each single sensor to its own dedicated 64-kbit/s timeslotwould limit the maximum possible amount of Ethernet controlled devices to 31 for anE1 link. Furthermore Ethernet broadcast traffic encapsulated in the TDM link betweenFMX2R3.2 network elements is reduced to a minimum.

Fig. 2.2 Ethernet Switching via an FMX2R3.2 Network

For connection to the public switching network the channel-associated signaling is con-verted in V5.1/V5.2 protocols in conjunction with system module CMXII from FastLink,see Fig. 2.3.

Fig. 2.3 Access via FMX2R3.2 Network to V5.1/V5.2 Exchange

1

4

sensor 1 to 4

Exch

2 Mbit/sG.703

2 Mbit/sG.703

2 Mbit/sG.703

2 Mbit/s, G.703

FMX2R3.2

FMX2R3.2FMX2R3.2FMX2R3.2

sensor 1 to 4 sensor 1 to 4

e. g. oil pipeline

Eth 10/100bT

Eth 10/100bT

Eth 10/100bT Eth 10/100bT

1

4 FMX2R3.2

Eth 10/100bT

2 Mbit/sG.703

2 Mbit/s, G.703

FMX2R3.2

Eth 10bT

Maintenance

of the oil

ET

HE

TH

ET

HETH ETH ETH

FMX2R3.2

ET

H

FMX2R3.2

ET

H

centre

pipeline

1

60

z.B. STM-1

STM-4 opticalor

Subs. Subs.

CMXII

2 Mbit/sG.703

2 Mbit/sG.703

Subs.

2 Mbit/sG.703

2 Mbit/s, G.703 2 Mbit/s, G.703V5.1/V5.2CAS

2 Mbit/sG.703

FastLinkFMX2R3.2

FMX2R3.2FMX2R3.2FMX2R3.2

Page 27: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 27

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Multiplexer FMX2R3.2 can be accomodated as follows:• up to 2 x in FMX2S (Flexible Multiplexer Shelf)• up to 2 x in MXS19C (Multiplexer Shelf 19’’)• in SNUS (Service Network Unit Shelf) in combination with the cross-connect multi-

plexer CMXC and the FastLink system module SMX1/4c• in ONU 30 FTTB or• in ONU 20 FTTO.

ONU 30 FTTB and ONU 20 FTTO each connect a multiplexer to the transmission net-work by means of a line termination unit (LTx). It is possible to cascade several ONUsor to operate two ONUs in a point-to-point connection for fixed analog or digital connec-tions.

Network termination units which are connected to the multiplexer enable one or two datainterfaces to access the subscriber directly. Network termination units for the basic ac-cess connect remote ISDN subscribers via Uk0 (4B3T or 2B1Q) to the multiplexer.

Fig. 2.4 Connecting the Network Termination Units to the Multiplexer

The multiplexer supports the following network termination units:• Network termination unit NTU for interfaces in accordance with G.703 (64 kbit/s),

V.24 (Subbit rates, 64 kbit/s), V.35, V.36, X.21 (subbit rates, 1 or 2 × 64 kbit/s), linkedto the FMX2R3.2 via Uk0/2B1Q

• Network termination unit for basic access NTBA via Uk0 (4B3T/2B1Q).

Operating modes of FMX2R3.2

The FMX2R3.2 multiplexer supports the following applications:• Operating modes, chosen from

– TMX2 × 30 terminal multiplexer, which contains two complete multiplexers– DIMX drop-insert multiplexer, with which individual channels of a signal which is

connected between the two 2-Mbit/s ports of the multiplexer can be tapped off andinserted

– TMX30(1+1) terminal multiplexer with 1+1 standby operation, which switches a2-Mbit/s link to another on a fault

The transmission capacity of the multiplexer in the TMX2×30 and DIMX operatingmodes is 60 channels each with 64 kbit/s, and in TMX30(1+1) operating mode it is30 channels. The assignment of timeslots to the two 2-Mbit/s ports is independentof the channel plug-in unit positions in the multiplexer. If no signaling is transmitted,up to 31 or 62 channels each with 64 kbit/s are available.

• Port-to-port connections for V.24, V.35, V.36, RS530 or X.21 interfaces• End-to-end protection on n × 64-kbit/s level for analog 2-wire/4-wire interfaces (with

or without E&M) and for V.24, V.35, V.36, RS530, X.21 interfaces

FMX2R3.2

8

1

NTU

UK0 (2B1Q)

n × 64 kbit/s (n ≤ 2)X.21,V.24V.35,V.36/RS530

Subratesup to n × 64 kbit/s

G.703 64 kbit/s

NTBA

UK0 (2B1Q)

n × 64 kbit/s (n ≤ 2)S0

NTBA

UK0 (4B3T))

n × 64 kbit/s (n ≤ 2)8

1

S0

IUL82C

IUL84C

Page 28: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

28 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

• Broadcasting for POTS with local battery, analog 2-wire/4-wire leased lines and alldigital interfaces

• Ethernet layer 2 switch– Ethernet over TDM mirror– Ethernet switch with 4 Ethernet ports and 1 or 2 TDM uplinks ports per module– 2 modules per CPF2 possible– TDM multiplexer as two times terminal or drop and insert mode– Data rate at TDM: 1 up to 31 time slots per E1 port– L2 switch support for multiple address data bases on a per port, for transparent

router applications– 4 Ethernet 10/100 PHYs according to IEEE802.3 and 802.3x– Quality of service support with four traffic classes– Flow control and back pressure– automatic MDI/MDIX crossover– CLI interface for link status and control, statistic counters

• Digital conference and point-to-multipoint operation• Voice channel in common frequency radio networks

This application is realized using system modules FMX2R3.2 (with CUD andUAC68) and CMXC, see also user manual UMN CMXC.1+1 protection switching of n × 64-kbit/s and 2-Mbit/s signals is not supported in thiscase.

• IWU submodules of the CPF2 convert digital subscribers, which are connected at agiven customer network with X.50/X.51 data structures, into one of the system-inter-nal data structures V.110/X.30 or I.4601).

• Timer jobs for one or two complete channels over a maximum of two timeslotsWith end-to-end protection, a timer job can be set up for each subscriber port.

• Software-controlled configuration, operation and operation monitoringSuitable interfaces are present for connecting a local operating PC and for connect-ing to a TMN. Connected network termination units can be operated and monitoredvia the multiplexer.

1) Special documentation is available for the IWU sub modules (Prod. No. A50010-A3-H102-*-7619).

Page 29: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 29

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

2.2 System Structure

2.2.1 OverviewThe multiplexer includes the following units, see Fig. 2.5:• A central unit drop/insert CUD• Up to 6 line cards LC, of the following types:

– SUB102 subscriber converter, a/b wire, subscriber side– SLX102 or SLX102E subscriber converter, a/b wire, switching side– SLB62 subscriber converter for local battery, a/b wire– UAC68 universal analog line card, 2/4-wire leased lines or with E&M– SEM106C 2-wire E&M converter1)

– SEM108HC 4-wire E&M converter1)

– LLA102/104C line card for analog 2-wire/4-wire leased lines– I8S0P ISDN line card, S0 interface– IUL82C ISDN line card, Uk0 interface 2B1Q– I4UK2NTP ISDN line card, Uk0 interface 2B1Q, switching side– IUL84C ISDN line card, Uk0 interface 4B3T– I4UK4NTP ISDN line card, Uk0 interface 4B3T, switching side– DSC104C digital signal channel, 64 kbit/s, codirectional, G.703 interfaces– DSC6-n×64C digital signal channel, n × 64 kbit/s, G.703 interfaces– CPF2 digital signal channel

with maximum of 4 interface modules for- subrates up to 31 × 64 kbit/s, V.24/V35/V36/RS530 or X.21 interfaces- protocol conversion X.50/X.51 to X.30/V.110/I.460with maximum of 2 interface modules, each interface module with- 4 Ethernet 10/100Base-T interfaces

– CM64/2 (digital signal card, 2 Mbit/s channel multiplexer, G.703)• Optionally a bus extension card BEC, if up to 12 line cards are connected to the

CUD2).

The multiplexer is operated and monitored via the QD2 slave interface (QD2-S) of thecentral card, which is connected to a supervision unit.

1) only in MXS19C shelf and ONU 20 FTTO

2) only possible in the shelves FMX2S and MXS19C

Page 30: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

30 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Fig. 2.5 Overview Circuit Diagram of Multiplexer

2.2.2 Central Unit CUDThe CUD forms the interface between the line cards of the multiplexer and the PCM sig-nals at E1 ports E1A and E1B. In a synchronous network it operates as a Terminal Mul-tiplexer or as a drop/insert multiplexer.

2.2.3 Bus Extension Card BECThe BEC is used when more than 6 LCs are used:• for full utilization of the 2-Mbit/s signal,

since a few LCs have a limited number of interfaces,• for a comprehensive range of different subscriber interfaces.

A CUD can operate 6 LCs without a BEC, with a BEC it can operate 12 LCs. The numberof time slots of the 2-Mbit/s signal is not increased by a BEC. The BEC connects thesystem bus to a further 6 LC slots and supplies these LCs with the necessary voltages.

2.2.4 Units for Operation and SupervisionThe operation and supervision units include:• Supervision unit SUE (-B1) in shelves SNUS, FMX2S and MXS19C• Supervision unit MSUE in the ONU 30 FTTB• Supervision unit COSU in the ONU 20 FTTO• Supervision unit OSU for synchronous or asynchronous transmission of control in-

formation for remote equipment• SISA concentrator SISAK for asynchronous transmission of control information to

remote equipment (can only be installed in shelf MXS19C).

F2/D2 subscriber interfaces

System bus

Networ k interfaces

ISDN Uk0, 4B3T

CUD

ZA(A), ZA(B)

SUE

F

QD2-S

Tin/out

E1A (G.703)

QD2-S

LC1)

7

LC1)

12

QD2 bus

Sa5 to Sa8

QD2-MAlarms

E1B (G.703)

BEC1)

LC1

LC6

ECC

n × 64 kbit/s, V.35

≤ 64 kbit/s, V.36

≤ 64 kbit/s, V.35

≤ 19.2 kbit/s, V.24

n × 64 kbit/s, X.21

≤ 64 kbit/s, X.21

n × 64 kbit/s, V.36

2 Mbit/s, G.703

n × 64 kbit/s, G.703

VF, a/b, 2w/4w

ISDN S0

VF, E&M, 2w/4w

VF, a/b, 2w LB

ISDN Uk0, 2B1Q

1) optional10/100Base-T

Page 31: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 31

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

For a DCN (Data Communication Network) these units implement a virtual concentrator(SISA-V) in each case. They possess QD2 slave and QD2 master interfaces for incor-porating the FMX2R3.2 into a SISA communication network. For local operation an F-in-terface is available at the supervision units. The SUE can also signal external alarms(e.g. door contact, fan failure) to the operating system (OS).

2.2.5 Line Cards for Analog Services

2.2.5.1 Converter SUB102The SUB102 subscriber converter provides 10 a/b interfaces and can be used for thefollowing applications:• Connection of conventional analog subscriber telephones or extension telephones

to digital exchange• Together with the SLX102/E for connection of conventional analog subscriber tele-

phones or extension telephones to analog exchange or to an analog subscriber ac-cess of digital exchange.

Fig. 2.6 Subscriber Access to Digital Exchange

Fig. 2.7 Subscriber Access to Analog Exchange

2.2.5.2 Converters SLX102 and SLX102EThe SLX102 or SLX102E provides 10 a/b interfaces and, in conjunction with theSUB102, the SLX102/E connects conventional analog subscriber telephones or exten-sion telephones to analog exchange or to an analog subscriber access of digital ex-change, see Fig. 2.7. The grounding key function is transmitted for use in PABXs.

FMX2R3.2

TE SUB102

F2 2 Mbit/sCAS

EXCH

FMX2R3.2

TE SUB102

F2

FMX2R3.2

SLX102E

F2 2 Mbit/s

EXCH

CAS

Page 32: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

32 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

2.2.5.3 Converter SLB62The SLB62 (2-wire LB) line card connects up to 6 analog subscriber terminals with a lo-cal battery power supply to the transmission network.

2.2.5.4 Universal Analog Unit UAC68Universal analog line card UAC68 for 6 channels is used to provide either analog 2-wireor 4-wire interfaces with signaling (E&M operation) or without signaling (analog leasedlines).

2.2.5.5 E & M Converter SEM106CThe SEM106C line card is used for connection of 10 VF signals in 2-wire operation toexchange or transmission equipment which operates with E&M signaling.

2.2.5.6 E & M Converter SEM108HCThe SEM108HC line card is used in the multiplexer for connection of 10 VF signals in4-wire operation to exchange or transmission equipment which operates with E&M sig-naling.

2.2.5.7 Analog Leased Lines LLA102/104CThe analog leased line LLA102/104C with 10 channels is used to provide up to 10 ana-log leased lines within a digital transmission link for service-neutral transparent point-to-point transmission of information.

The channels can be operated with 2- or 4-wire interfaces.

Fig. 2.8 LLA102/104C in Leased Lines with 2-Wire Interface

Fig. 2.9 LLA102/104C in Leased Lines with 4-Wire Interface

FMX2R3.2

TE

F2

FMX2R3.2

F2 2 Mbit/s

TE

LLA102/104C

LLA102/104C

FMX2R3.2

TE

F2

FMX2R3.2

F2 2 Mbit/s

TE

LLA102/104C

LLA102/104C

Page 33: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 33

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

2.2.6 Line Cards for ISDN Services

2.2.6.1 ISDN Line Card I8S0PThe I8S0P unit enables an ISDN basic access to be established for remote subscriberterminal equipment or PBXs with S0 port:• With dial-up connections between exchange and remote subscriber terminal equip-

ment or private branch exchanges with CAS (FMX2R3.2 specific, for lengtheningfrom S0 to UK0) or FA signaling, Fig. 2.10 and Fig. 2.11.

• With leased lines between subscriber terminal equipment or private branch ex-changes with FA signaling, Fig. 2.12.

• With leased lines in stand-alone mode, Fig. 2.13.

The I8S0P contains 8 independent S0 interfaces according to ITU-T I.430 that are usedin NT mode or in TE mode.

Dial-up connections with CAS signaling

Fig. 2.10 I8S0P Dial-up Connection with CAS Signaling

Dial-up connections with FA signaling

Fig. 2.11 I8S0P Dial-up Connection Using FA Signaling

S0 2 Mbit/sLE

Uk0TE/

NT mode

I4UK2NTPPBXNT mode

I8S0P

2 Mbit/s Uk0

LT mode

IUL84C NTBA

e.g. multiplexerwith DSC6-nx64C

NT mode

I8S0PS0TE/PBX

S0 PBX

LENT mode

I4UK4NTP

FA

Uk0

2 Mbit/s

2 Mbit/sI8S0P

TE mode(NT mode)

LT mode

IUL84C2 Mbit/sUK0

NTBA

Page 34: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

34 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Leased-line connections using FA signaling

Fig. 2.12 I8S0P Leased-line Connections Using FA Signaling

Leased-line connections for stand-alone operation multiplexer

Fig. 2.13 I8S0P Leased-line Connections for Stand-alone Operation

2.2.6.2 ISDN Line Cards IUL82C and IUL84CThe IUL82C and IUL84C line cards with 8 Uk0 interfaces are employed within digitaltransmission links between subscribers and switching equipment on the subscriber sidewhen ISDN network termination units are to be connected to the multiplexer.

The IUL82C line card is used for 2B1Q code, while the IUL84C line card implements the4B3T code.

This allows the following applications:• Dial-up connections between exchange and subscriber terminal equipment with

CAS signaling (FMX2R3.2 specific, in repeater mode)or with FA signaling (IUL84C only),

• Leased-line connections in stand-alone mode.

NT mode

S0

NT mode

LT mode

IUL84C

FA e.g multiplexer2 Mbit/s

2 Mbit/s

2 Mbit/s

2 Mbit/sS0

Uk0

with DSC6-nx64C

I8S0P I8S0P

NT mode

I8S0PS0

NT-Mode

I8S0P

LT-Mode

IUL82C/

e.g multiplexer2 Mbit/s

2 Mbit/s

2 Mbit/s

2 Mbit/s S0

Uk0

with DSC6-nx64CTE mode

S0

e.g. multiplexer2 Mbit/s

with DSC6-nx64CIUL84C

2 Mbit/sI8S0P

Page 35: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 35

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

The Uk0 ISDN interface conforms to standard TS 102 080. Data transmission is alsopossible in the format 128 kbit/s via the B1- and B2-channels of an ISDN line. The fram-ing integrity of the 128-kbit/s connection is ensured. Connected NTBAs are fed per portwith up to 1.1 W power as consumed at the NTBA.

Dial-up connections with CAS signaling

Together with unit I8S0P, the IUL82C or IUL84C operates in an dial-up connection withCAS signaling for lengthening from S0 to UK0, see Fig. 2.10. Additionally, the IUL82C,or IUL84C can be used as shown in Fig. 2.14:

Fig. 2.14 Dial-up Connection of the IUL82C or IUL84C with CAS Signalingin Repeater Mode

Dial-up connections with FA signaling

Together with unit I8S0P, the IUL84C implements an dial-up connection withFA signaling by Fig. 2.11. Additionally, the IUL84C can be used as shown in Fig. 2.15:

Fig. 2.15 Dial-up Connection of the IUL84C with FA Signaling

Leased-line connections with FA signaling

Together with unit I8S0P, the IUL84C implements an ISDN leased-line connection withFA signaling between Uk0 and S0, see Fig. 2.12 In addition to the leased-line connec-tions shown in Fig. 2.12 the IUL84C can be used as shown in Fig. 2.16:

2 Mbit/sLE

Uk0NTBA

NT-Mode

I4UK2NTP

LT-Mode

Uk0TE

IUL82C/IUL84C

2 Mbit/sLE

Uk0NTBA

NT modeLT mode

IUL84CUk0

TE

FA e.g. multiplexer2 Mbit/s with DSC6-nx64C

FAe.g. multiplexer

2 Mbit/s

with DSC6-nx64C

I4UK4NTP

Page 36: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

36 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Fig. 2.16 Leased-Line Connections of the IUL84C with FA-Signaling

Leased-line connections in stand-alone mode

In conjunction with card I8S0P the IUL82C or IUL84C implements in stand-alone modethe conversion from S0 to Uk0 in an ISDN connection, see Fig. 2.13. In addition to thepermanent connection shown in Fig. 2.13, the following applications can be implement-ed:

Fig. 2.17 Leased-Line Connections of the IUL82C in Stand-alone Mode

Fig. 2.18 Leased-Line Connection of the IUL84C in Stand-alone Mode

2.2.6.3 ISDN Line Cards I4UK2NTP and I4UK4NTPISDN line cards I4UK2NTP and I4UK4NTP with 4 Uk0 interfaces provide the interfacebetween multiplexer and ISDN switching equipment on the switching side. The datafrom the I4UK2NTP is transmitted using the 2B1Q code and the data from theI4UK4NTP is transmitted using the 4B3T code.

Dial-up connections with CAS signalling

Together with card I8S0P the I4UK2NTP implements in CAS dial-up connections con-version from Uk0 to S0, see Fig. 2.10.

With card IUL82C on the subscriber side, unit I4UK2NTP (exchange side) operates inthe transmit-receive multiplexer, see Fig. 2.14.

FAe.g. multiplexer2 Mbit/s

with DSC6-nx64C

2 Mbit/s

LT mode

IUL84C

NT mode

FA e.g. multiplexer2 Mbit/s

2 Mbit/s

with DSC6-nx64C

Uk0 Uk0I4UK4NTP

LT mode

IUL82C

LT mode

IUL82C2 Mbit/sUk0NTU

NTBADTEUk0 NTU

NTBA DTE

V.24/X.21/V.35/V.36/

S0

V.24/X.21/V.35/V.36/

S0

LT mode

IUL84C

LT mode

IUL84C2 Mbit/sUk0

NTBADTEUk0

NTBA DTES0S0

Page 37: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 37

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Dial-up connections with FA signaling

Together with unit I8S0P, the I4UK4NTP implements in FA dial-up connections conver-sion of Uk0 to S0, see Fig. 2.11.

With the IUL84C (as a subscriber-side unit) the I4UK4NTP operates in the back-to-backmultiplexer as a Uk0 extension, see Fig. 2.15.

2.2.7 Line Cards for Digital Services

2.2.7.1 Digital Signal Unit DSC104CThe DSC104C (Digital Signal Channel) line card will be employed for the transmissionof digital signals at a bit rate of 64 kbit/s. The unit incorporates 10 codirectional interfac-es which conform to ITU-T Recommendation G.703. If a signal is being transmitted, sig-naling bits a, b, c, d are given the fixed values 1 1 0 1.

2.2.7.2 Digital Signal Unit DSC6-nx64CDigital Signal Channel DSC6-nx64C provides 6 interfaces in accordance with ITU-TRecommendation G.703 and will be used for transmission of digital signals with bit ratesof n × 64 kbit/s (n = 1 to 30/31).

There is the option of operating the 6 interfaces codirectionally (n = 1 to 8) or with cen-tralized clock (n = 1). Two of the interfaces can also be switched over to contradirection-al mode (n = 1 to 30/31).

If a signal is being transmitted, signaling bits a, b, c, d are given the fixed values 1 1 0 1.

2.2.7.3 Digital Signal Unit CM64/2The CM64/2 line card is used for network branch to the 2-Mbit/s level. The CM64/2 com-bines any number of time slots and the associated signaling information (CAS) of the E1ports (2 Mbit/s) of a multiplexer with a 2-Mbit/s signal.

2.2.7.4 Digital Signal Unit CPF2The CPF2 is a universal digital signal channel unit for providing various local data inter-faces (V.24, V.35, V.36, X.21), for connecting to X.50 or X.51 data networks as well asfor data transmission via Ethernet.

The following interface modules are available:

Module Interfaces Operating mode Bit rates

CIM-V.24 V.24 synchronous

asynchronous

0.6 to 64 kbit/s and 128 kbit/s

0.3 to 38.4 kbit/s and 115.2 kbit/s

CIM-V.35 V.35 synchronous

asynchronous

0.6 to 56 kbit/s, n × 64 kbit/s (n ≤ 30 with CAS/

31 without CAS)

0.3 to 38.4 kbit/s and 115.2 kbit/sCIM-V.36 V.35/RS530

CIM-X.21 X.21

CIM-nx64E 10/100Base-T n × 64 kbit/s (n ≤ 30 with CAS/31 without CAS)

Tab. 2.1 Interface Modules for Use on the CPF2

Page 38: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

38 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

There are 4 interfaces on the channel unit which will be implemented with four plug-inchannel interface modules (CIM-V24, CIM-V35, CIM-V36 or CIM-X.21). The function,electrical interface and speed of the 4 ports can be configured individually and indepen-dently of each other.

Up to 2 Ethernet interface modules CIM-nx64E can be equipped per CPF2. EachCIM-nx64E module provides 4 Ethernet ports.

Beside the unlimited use of CIM-nx64E module in combination with all other CPF2-mod-ules (CIM-V.24/-V.35/-V.36/-X.21) is possible via separate traffic. The number of linecards CPF2 is only limited by the shelf or ONU equipment rules.

2.2.7.5 Front Panel Connectors for the CPF2Different front panel connectors are intended to simplify matters wiring of the CPF2 datainterfaces with external data terminals, see also installation manual (UMN:IMN).The interfaces of the CPF2 are connected with the front panel connectors via specialadapter cables.

Fig. 2.19 CPF2 Front Panel Connectors

Front panel connectors Ordering number

V.24 S42023-A862-S12

X.21 S42023-A862-S13

V.35 with Sub-D connection S42023-A862-S14

V.36 S42023-A862-S15

RS 530 S42023-A862-S25

V.35 S42023-A862-S26

Ethernet 10/100Base-T S42023-A862-S16

Tab. 2.2 CPF2 Front Panel Connectors

V.24RS530X.21V.36V.35V.35

3

4

1

2

Page 39: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 39

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

2.3 External Interfaces

E1 Interfaces

The E1 interfaces are on the CUD central unit drop/insert and conform to ITU-T Recom-mendation G.703. Each E1 interface has a transmission rate of 2 Mbit/s. By setting aswitch, the interface can be terminated as desired with 120 Ω or 75 Ω.

F2/D2 Subscriber Interfaces

The F2/D2 subscriber interfaces are provided by the line cards. They are used to con-nect analog, digital and ISDN subscribers. The number of subscriber interfaces for eachLC card type is different. For detailed information on the line cards, see Sections 2.2.5to 2.2.7.

10/100 Base-T Ethernet Interfaces

The 10/100Base-T interfaces are provided from the Ethernet module on the line cardCPF2. They are used to connect monitoring equipment with 10/100 Base-T interfaces,which data are transmitted via the time slot structure of a 2-Mbit/s signal. 4 Ethernet in-terfaces are available per Ethernet module, 2 modules can be equipped pre CPF2.

T3 Interface

The T3 interface is implemented by the central unit and conforms to ITU-T G.703/13. Anexternal 2048-kHz clock is fed in via the T3in interface. The interface can be set to highor low resistance by a switch. The 2048-kHz clock, which is derived from the appropriateclock source, is output at the T3out interface, see Section 4.5.

QD2 Interface

The QD2 interface of the multiplexer is on the central unit and conforms to EIA RS485.It is in the form of a slave interface (QD2-S), and implements access to the FMX2R3.2network element and to remote network termination units, see also Section 2.10.

ZA(A) and ZA(B) Interface

The interface signals an alarm in the direction of the central service observation equip-ment.

The ZA(A) interface is in the form of a normally closed contact. At the normally closedcontact ZA(A), either A alarm (urgent) or S alarm (service) is output, and for both casesfailure of the operating voltage. The ZA(B) interface is in the form of a normally opencontact. It is used to signal B alarm (non-urgent).

Interface of ECC

Via the ECC interface of the CUD, a control signal can be derived from any timeslot ofone of the E1 ports and inserted in the opposite direction. This timeslot can then no long-er be used for information transmission. The ECC interface conforms to ITU-T Recom-mendation V.11.

iAt the 64 kbit/s bit rate, no transparent data transmission is possible. The data signalmust be transmitted using HDLC frames.

Page 40: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

40 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Sa Bit Interfaces

The Sa bit interfaces are designed according to the interface conditions of EIA RS485.Four Sa bit interfaces, Sa5 to Sa8, are available on the CUD.

One symmetrical signal line for the sending direction and one for the receiving directioncan be connected for each Sa bit. The transmission speed is 0.6 kbit/s (signal distortionabout 15 %) to 1.2 kbit/s (signal distortion about 30 %).

The following options for the data paths are available for all Sa bits on the CUD unit:• Source for E1Aout: low-level / high-level / Sa*in / E1Bin / Sa*in ANDed with E1Bin,• Source for E1Bout: low-level / high-level / Sa*in / E1Ain /Sa*in ANDed with E1Ain,• Source for Sa*out: low-level / high-level / high-resistance / E1Ain / E1Bin / E1Ain

ANDed with E1Bin.

2.4 Internal Interfaces

System Bus

The system bus is subdivided into the PCM highway and the LC bus. The line cards alsoreceive their power supply via the system bus.

PCM Highway

The PCM highway forms the interface between the central unit and the various linecards for serial transmission of data channels and PCM-coded speech signals.

The sending and receiving signals of the PCM interface are synchronized by the sameclock, but can be in any phase position in relation to each other as far as the frame clockis concerned. Both signal flow directions keep their own frame synchronization pulse.

LC bus

The LC bus is an 8-bit computer bus for transmission of control and signaling data be-tween the central unit and the LCs.

The interface works on the master-slave principle, i.e. the central unit is the master andthe LCs are the slaves. Irrespective of the division in the subrack, up to 12 line cards canbe operated every 4 ms with one CUD central unit drop/insert.

!If the option of frame synchronization of the CUD is used, the Sa bits are not availableas a transmission channel. They are permanently set to “1” in the sent signal. The Sa bitinterfaces are switched to high-resistance.

LC

LC

PCM highway

.

.

.

4 Mbit/s

SYNCclock

(PCM)

CUD

SUE

Page 41: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 41

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

2.5 Power SupplyThe multiplexer is supplied with an input voltage of −48 V/−60 V.

Power supply modules on the central unit convert the −48 V/ −60 V input voltage into thenecessary operating voltages, +5 V and −5 V, to supply the modules on the unit andLCs. The −48 V/ −60 V input voltage is protected by a 1 A replaceable fusible cartridgeon the unit.

Additionally, the power supply of the central unit switches the UKZU voltage (−48 V/−60 V) to the LCs, protected by a 2 A replaceable fusible cartridge.

CUD

SUELC

LC

LC bus

.

.

.

AD0 to AD7

4 ×CTRL

Page 42: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

42 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3 Components

3.1 SNUS SubrackThe SNUS is a subrack in 19“ design, and can be adapted to the fitting conditions forthe ETSI housing and racks using adapters.

In the shelf SNUS, the FMX2R3.2 multiplexer works on either a CMXC crossconnect, oran STM-1/STM-4 SDH feeder. Optionally, a line termination device which transmits2 × 2 Mbit/s on one or two glass fibers, 2 x 2-Mbit/s signals SHDSL (2-wire/4-wire) orHDB3-coded (UK2) on 2-core local loops, depending on the infrastructure, can also beused.

Fig. 3.1 Use of FMX2R3.2 Multiplexer in an SNU Shelf (Example)

Fig. 3.2 Shelf SNUS (without Front Panel)

The subrack can accept units in double Eurocard format, and has a backplane board toconnect the internal and external interfaces.

FMX2R3.2

CMXC

2 × LTx

LTx

sscr. 1

sscr. 60

1

4

8

16

2 Mbit/s

STM-1

STM-4 optical

2 x 2 Mbit/s1

G.703POTS

ISDN (UK0/S0)data(G.703/V.24/

opt., UK2

opt./electrical

Leased Lineor Feeder

26

1 ... 26SHDSL

V.35/V.36/Eth.RS530/X.21)

2-wire/4-wire LL/E&M2 Mbit/sG.703

2 Mbit/sG.703

SMX1/4c

Subscribers

(2-wire/4-wire)

4 x 2 Mbit/sopt., UK2

Leased Lineor Feeder

SHDSL(2-wire/4-wire)

Page 43: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 43

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

The SNUS is equipped with a terminal panel which provides all external interfaces viathe corresponding sub-D connectors. The exceptions are the optical interfaces of thecorresponding units which are only present on the units themselves. For mechanicalrouting of the optical fibers the SNUS is equipped with FO clips.

Different front panel connectors are intended to simplify matters wiring of the CPF2 datainterfaces with external data terminals, which can be plugged into an external Main Dis-tribution Field (MDF 180 or MDF 210), see UMN:IMN. For cabling the connectors in theterminal panel to the front panel connectors, the adapter cable S42023-A862-S11 hasto be used.

Also the 4 ethernet interfaces of one CIM-nx64E module are accessible at a front panelconnector. The connector also provides the RS232 interface. Also available at the frontpanel connector is a status LED.

3.1.1 FittingThe SNUS has 18 slots, but only a maximum of 16 of these can be used at the sametime.

Fig. 3.3 SNUS Equipping

2

SU

E

3 4 5 6 7 8 9 10 11 12 13 1714 16

LCT

1

CU

D

LC 1

LC 2

LC 3

LC 4

LC 5

LC 6

PU

16

CU

C

CU

C

PU

16

TU

AD

M1e

/o/A

DM

4

PS

D

LTx

11)

LTx

21)

LTx

32)

1) LT2ME1/LTO2) LT2ME1/LTO

1815

OT

SU

2M

optional fitting3) internal 2-Mbit/s link to CUD, LTx 1 to LTx 3

4) internal 2-Mbit/s connection to SMX1/4c5) 2-Mbit/s ports of ADM1o/ADM1e/ADM4

!For the two slots 207 and 208, into which both line cards and line termination units canbe inserted, before the units are inserted the associated DIL switches must be checked,see Tab. 3.4 and Fig. 3.10.

Page 44: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

44 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

FMX2R3.2 and LTx

Plug-in unit 1) Plug-in place Filter 5)

201 202 203 204 205 206 207 208 209 218

Sub D in terminal panel at 2wire LC (a, b)

or LTx

C1 D1 E1 F1 G1

G1

H1

H1 L1 V42256

-Z82-M1

V42256

-Z82-M2Sub D in terminal panel at 4wire LC (c, d) C2 D2 E2 F2 G2 H2

SUE ×

CUD ×

UAC68 × × × × × × ×

SUB102 × × × × × × ×

SLB62 × × × × × × ×

LLA102/104C × × × × × ×

I8S0P × × × × × ×

I4UK2NTP × × × × × × ×

IUL82C × × × × × × ×

IUL84C × × × × × × ×

I4UK4NTP × × × × × × ×

CM64/2 × × × × × ×

SLX102/E × × × × × × ×

DSC104C × × × × × ×

DSC6-nx64C × × × × × ×

CPF22) × × × × × × ×

LT2ME13) ×4) ×4) ×

LTO × × ×

OTSU2M ×

1) Pay attention to switch positions according at different equipping variants!

2) Modules for CPF2 that can be plugged: - CIM V.24, - CIM X.21, - CIM V.35, - CIM V.36, CIM-nx64E

3) Modules for LT2ME1: - Uk2mp, - SDSLmp, - SDSLop, - SDSL4op optionally with T4 module, - G703sh

4) On these slots, only one interface for copper transmission lines of each LT2ME1 is wired to the Sub D in terminal panel

(means only one module - Uk2mp, - SDSLmp, - SDSLop, - SDSL4op, - G703sh)

5) Filter types according to LC types and to Sub D in terminal panel that must be plugged and screwed on

Tab. 3.1 SNUS FMX2R3.2 and LTx Equipping

Page 45: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 45

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

CMXC

Feeder SMX1/4c

Interfaces/

Plug-in unit

Plug-in places

210 211 212 213

Port unit 1: G.703; 1 to 4/5 to 8 J1/J2

Port unit 1: G.703: 9 to 12/13 to 16 K1/K2

Port unit 2: G.703; 1 to 4/5 to 8 N1/N2

Port unit 2: G.703: 9 to 12/13 to 16 P1/P2

PCI/PCIS M1 M2

ECC L2 L2

PU16(1) ×

CUC(1) ×

CUC(2) ×

PU16(2) ×

Tab. 3.2 SNUS CMXC Equipping

Interfaces/

Plug-in unit

Plug-in places

214 216 218

(+) (-) 48V (3W3) V1, X1

V.11 interface T2

2-Mbit/s interface Q1, Q2, R1, R2, S1 S2

STM-1/STM-4 interface V2, V3, W2, W3

E3 interface U2, U3

ADM1o L-1.1 ×

ADM1o S-1.1 ×

ADM4o L-4.1 ×

ADM4o S-4.1 ×

ADM1E ×

TC21E1 ×

TC21E1R ×

TC1E3 ×

PSD ×

Tab. 3.3 SNUS SMX1/4c Equipping

Page 46: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

46 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.1.2 Internal Connections

2-Mbit/s Connections

The internal wiring of the 2-Mbit/s connections is shown in Fig. 3.4.

Fig. 3.4 SNUS Internal 2-Mbit/s Connections, Subrack fitted with SMX1/4c

PCI Connections

Of the 12 PCI interfaces of a CUC, the first 4 are fed to the left-hand PU16 (slot 10) asPCI (from the active CUC, slot 11) and as PCIS (from the redundant CUC, slot 12).

Fig. 3.5 SNUS Internal Wiring of PCI Interfaces

CUD LTx PU16123456789

10111213141516

PU16123456789

10111213141516

LTxLTx TU123456789

101112131415161718192021

ADM1123456789

101112131415161718192021

E1I

/O

E1I

/O

E1I

/O

IE1/

O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/O

E1I

/OConnectors intermination panel

ADM41 2 3

CUC123456789

101112

CUC123456789101112

PU1612341234

PU1612341234

CCUR

CCURS

PCI

PCIS STSB

clocksynchr.

PCIS

PCIS

PCIS

PCIPCI

PCI

PCI

4 x

PC

I, C

CU

R

4 x

PC

IS, C

CU

RS

CCUR CCURS

Connectors intermination panel

1 2

Page 47: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 47

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Interfaces 5 to 8 are wired analogously as active and redundant interfaces to the right-hand PU16 (slot 13). The changeover signals for these internal interfaces (CCUR fromthe active CUC, CCURS from the redundant CUC) are in asymmetrical form.

Interfaces 9 to 12 of the two CUCs are fed separately (active/redundant) to one D-subconnector each in the termination panel. The required changeover signals CCUR andCCURS for these external interfaces are in the form of symmetrical control lines, andalso accessible in the connectors.

34-Mbit/s and STM-1 Connections

The internal 34-Mbit/s and STM-1 connections are shown in Fig. 3.6.

Fig. 3.6 SNUS Internal 34-Mbit/s and STM-1 Connections

3.1.3 Clock Synchronization

Fig. 3.7 SNUS Clock Distribution

Synchronous signals can be fed externally via connectors in the termination panel, andreach the ADM1/ADM4 as T3in 2 on CUD, LE2 and CUC units and as T3in 1. The sub-rack loops the T3in lines for onward connection to other subracks.

For synchronization purposes, T3out signals can be extracted from the CUCs (T3out 1)or CUD (T3out 2).

TU ADM1e

STM1IN1

STM1OUT1

STM1IN2

STM1OUT2

E3IN1

E3OUT1STM1OUT3

STM1IN3

CUD LTx LTx LTx CUC CUC ADM1

T3o

ut

T3i

n

T3in 1

T3in 2

T3out 1

T3out 2

1) 1) 1) ADM4

Connectors intermination panel

1 2 3 1 2

Page 48: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

48 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.1.4 QD2 AccessThe internal wiring for operation and monitoring is shown in Fig. 3.8.

The TMN access for the subrack is the QD2 slave connector in the termination panel.This leads to the QD2 slave port 1 of the SUE and to a changeover unit, which switchesthe internal QD2 bus to either the QD2 master port of the SUE (in standalone operationof the subrack) or parallel to the QD2 slave port 1 of the SUE (SNU operation).

The T terminals of the QD2 slave interface 1 of the SUE are also accessible in the QD2slave connector.

Fig. 3.8 SNUS QD2 Access

The following internal DCN channels can be used:• ECC channel of CUD, 4 × ECC channels of CUC 1/CUC 2

The ECC terminations of the two CUC positions are connected in parallel. Two of thefour ECC interfaces are designed with clock transfer.

• Overhead channel of LTx on slot 3• V.11 channel of ADM1/ADM4.

The QD2 slave port 2 of the SUE is in the QD2-M connector. Via this port, the DCN chan-nel OH64 of the line termination unit LTx3 can be connected using an appropriately as-signed connector.

3.1.5 AddressingAll units in this subrack, except SUE and CUD, are assigned slot addresses. For the ad-dresses which are assigned to the slots, see Section 3.1.7.

The SISA address of the SUE is set using the DIL switch in the termination panel. Theaddress of the CUD is set using the DIL switch in the backplane.

For line termination units in line card slots, some address bits are given by the coding ofthe line cards. This makes it necessary to change address bits to adapt the addressing,if line termination units are installed in these slots. The change is done using DIL switch-es in the backplane, see Section 3.1.7.

SUECUD LTx LTx LTx LTx ADM1 PSDLTx

QD

2-S

QD

2-M

EC

C

V.1

1

QD2 bus

QD2 bus4

× E

CC

V.1

1

EC

C

QD

2-S

2

QD

2-S

1 (T

)

QD

2-M

OH64

SPI

S1 S2M

ADM4OTSU2M

Connectors intermination panel

F IF(for LCT)

1 2 3 1 2

Page 49: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 49

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.1.6 Power SupplyThe −48 V input voltages are fed via two separate 3W3 plugs in the termination panel.The positive poles of both voltages are connected to each other and to the backplane,via a common filter and protection device, as the operating ground GND. The negativepoles of both voltages are filtered separately, and supply the units in the subrack asMUP1 and MUP2. They are fed separately to the SUE, PSD, and PU16 and connectedto the units with reserve. For CUD, OTSU2M and the line termination units, reserve di-odes are arranged on the backplane. The CUC units are each connected to one of thetwo voltages.

The line cards receive the required secondary voltages +5 V and −5 V from the CUD,and also, after protection on the CUD, the KZU voltage (MUKZU).The PSD supplies the SMX1/4c with the secondary voltages +5 V and −5 V.

Without forced ventilation and with homogeneous distribution of heat sources in the sub-rack, about 105 W of power dissipation (1.25 W per 5.08 mm of basic grid) are permitted.

Fig. 3.9 SNUS Power SupplyO

TS

U2M

CU

D

LTx

1

LTx

2

LTx

3

CU

C 1

CU

C 2

PS

D

MUP 2

SU

E

PU

16

PU

16

MUP 1

48 V

+48 V

+

Connectors intermination panel

EMCprotection

EMCprotection

EMCprotection

Page 50: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

50 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.1.7 Switch Settings

DIL switch settings according equipping

Fig. 3.10 SNUS Front View without Front Panel

The equipping options are contained in Section 3.1.1.

The following points must be taken into account:

Before slots 207 and 208 are equipped, the DIL switches on the backplane must be setaccordingly to determine whether an LC of the FMX2R3.2 or an LTx module is to beequipped. DIL switches S111, S112, S113 and also S105, S106 and S107 must be setfor slot 207 and S114, S115, S116 and also S108 and S109 for slot 208 according tothe following table.

101

address

BA DC FE HG KJ ML PN RQ TS VU XW YX1V1A1 B1 C1 D1 E1 E1 G1 H1 J1 K1 L1 M1 N1 P1 Q1 R1 S1

116onoff

QD

2-S

lave

QD

2-M

aste

r

Tln

Tln

Tln

G.7

03

Tln

Tln

Tln

G.7

03 HD

SL(

LT3)

PC

I

G.7

03

G.7

03

G.7

03

G.7

03

G.7

03

(+)(

-)48

V

6A

(+)(

-)48

V

6AY2X2U2

E2 F2 G2 H2 J2 K2 L2 M2 N2 P2 Q2 R2 S2 T2

LC1

LC2

LC3

LC4

LC5

LC6

LTx2

LTx1

1 . .

4

9 . .

12

1 . .

4

9 . .

12

17. .

21

1 . .

4

9 . .

12

W2V2

D2C2B2

PBA2

Port Unit 1 CMXC Port Unit 2 Trib Unit SMX

A3

Tln

Tln

Tln

Tln

Tln

Tln

G.7

03

G.7

03

5 . .

8

13. .

16

EC

C

PC

IS

G.7

03

G.7

03

5 . .

8

13. .

16

G.7

03

G.7

03

5 . .

8

13. .

16

G.7

0317

. .21

V.1

1

U3 V3 W3 X3Y3

SMX DSMXTrib.Unit T

3T

3

xt. c

onta

cts

ZA

201 202 204 205 206 207 208 209 210 211 212 213 214 215 216 217 SNUS

201202

204 205 206 207 208 209 210 211 212 213214

215216

217

S103 S104

S10

2

S111 S112 S114 S115

S113 S116

S108

S109

S105

S106

S107

S101

Page 51: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 51

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Addresses

The SISA addresses of all units in this subrack are assigned to the backplane as follows:

Slot Equipping with LC of the FMX2R3.2 Equipping with the LTx module

207 - S111 to S113, all slider switches of

the DIL switches on “OFF”

- S105 to S116, all slider switches of

the DIL switches on “ON”

- S107, all slider switches of the DIL

switch on “OFF”

- S111 to S113, all slider switches of the

DIL switches on “ON”

- S105 to S116, all slider switches of the

DIL switches on “OFF”

- S107, all switches of the DIL switch on “ON”

208 - S114 to S116, all slider switches of

the DIL switches on “OFF”

- S108, all slider switches of the

DIL switch on “ON”

- S109, all switches of the DIL switch

on “OFF”

- S114 to S116, all switches of the DIL

switches on “ON”

- S108, all switches of the DIL switch

on “OFF”

- S109, all switches of the DIL switch on “ON”

Tab. 3.4 SNUS DIL Switch Settings

Unit In slot QD2 address Slot address (connected and fixed)

SUE 201 Is set using DIL switch

S101 in the terminal panel

of the SNUS, see Fig. 3.11

and Fig. 3.10.

5Bit = 1 to 30

5 bit = 3

(K0...K4 shelf model)

CUD 202 Is set using DIL switch

S102 on the backplane of

the SNUS, see Fig. 3.10.

5Bit; here only 1 to 8 usable

SEL_0 = GND

SEL_1 = GND

Line cards 1-6 203 to 208 4 bit = 1 to 6

LTx11) 2) 207 Fixed (5 bit) = 7

LTx21) 2) 208 Fixed (5 bit) = 8

LTx32) 209 Fixed (5 bit) = 9

PU16(1) 210 5 bit = 10

CUC(1) 211 Fixed (5 bit) = 13 5 bit = 11

CUC(2) 212 Fixed (5 bit) = 13 5 bit = 12

PU16(2) 213 5 bit = 13

ADM (SMX) 216 Fixed (5 bit) = 16

Trib.Unit 214

PSD 218 5 bit = 18

OTSU_2M 218 Fixed (5 bit) = 18

1) LTO, LTCOH, LT2ME1

2) If an LTx unit instead of a line card is equipped in slots 207 or 208, the slot must be configured

accordingly (with DIL switches S106 and S107 for slot 207 or with DIL switch S109 for slot 208).

Switches S105 and S108 must always be switched, see Fig. 3.10.)

Tab. 3.5 SNUS Units and Addressing

Page 52: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

52 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

DIL Switch S101 for SUE address

DIL Switch S102 for CUD address

TMN connection of the SNUS

3.1.8 Connector Assignment

Fig. 3.11 SNUS Connector Assignment

1

ON = LOW = log 0Example:Switch 1 on OFF corresponds to 20 = 1Switch 5 on OFF corresponds to 24 = 16Corresponds to address 17 for the SUE

ON (0)

OFF (1)

20 21 22 23 24

5

ON (0) OFF (1)

24

23

22

21

20

ON = LOW = log 0Example:Switch 2 on OFF corresponds to 21 = 2Corresponds to address 2 for the CUD

5

4

3

2

1

ON

S104

4321

ON

S103

4321

Delivery state:all slides at S103 are switched to “OFF” (to bottom) and at S104 allslides are switched to “ON” (to top), it means supervision of theSNUS by SUE (stand alone, without COMPS2 and without OSU)

48 V

48 V

QD

2-S

Ala

rm

PB

-+

-+

A C

QD

2-M

B D E F G H

I/O 1

-4

J

I/O 9

-12

K

HD

SL-

LT3

L

PC

I

M

I/O 1

-4

N

I/O 9

-12

P

I/O 1

-4

Q

I/O 9

-12

R

I/O 1

7-21

S

I/O 5

-8

I/O 1

3-16

EC

C-C

UC

PC

IS

I/O 5

-8

I/O 1

3-16

I/O 5

-8

I/O 1

3-16

I/O 1

7-21

ZA

T3a

nT

3out

V.1

1

Add.1)

E3IN

X153

X151

E3OUT

X154

X152

201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 218217

X121 X122

X123 X125 X127 X129 X131 X133 X135 X137

X124 X126 X128 X130 X132 X134 X136

X138

Exchange conn.

LC slots 2Mbit/s 2Mbit/s 2Mbit/sX120

X104 X106 X108 X110 X112 X114 X116

X103 X105 X107 X109 X111 X113 X115 X117 X141 X142X101

X102

X143

X144

Slot desig-

nations:

S101

T

HD

SL-

LT1

HD

SL-

LT2

Page 53: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 53

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

The possible equipping variants are shown in Tab. 3.1 to Tab. 3.3.

Power Supply Connectors X141 and X142

Coaxial Jack X151

X151: E3IN1 X152: E3OUT1 (interface 34 Mbit/s from Tributary Unit)

QD2 (X101 and X102) and Alarm Inputs (X121)

Signal Abbreviations

Pin X141 X142

1

2 -48V (MUP1) -48V (MUP2)

3 +48V (GND) +48V (GND)

Tab. 3.6 SNUS Connectors X141 and X142

Pin X101

QD2 slave

X102

QD2 master

X121

Alarm inputs

1 GND_S GND_S GND_S

2 QD2S1 OUT a QD2M IN a AIN1

3 QD2T1 OUT a AIN3

4 QD2S1 IN a QD2M OUT a AIN5

5 QD2T1 IN a AIN7

6

7 DAT

8 GND GND GND

9 QD2S1 OUT b QD2M IN b AIN2

10 QD2T1 OUT b AIN4

11 QD2S1 IN b QD2M OUT b AIN6

12 QD2T1 IN b AIN8

13

14 NRST

15 CLK

Tab. 3.7 SNUS 15-Contact Jacks X101, X102 and X121

GND Operation groundGND-S Shielded groundQD2SIN_A1, B1QD2SOUT_A1, B1

Slave 1 from the SUE

QD2SIN_A2, B2QD2SOUT_A2, B2

Slave 2 from the SUE

QIN_A/B, QOUT_A/B Master from the SUEQD2TIN_A, BQD2TOUT_A, B

T-connections of slave1 from the SUE

Page 54: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

54 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

T3-Interfaces X143 and X144

Signal Abbreviations

DAT, CLK, NRST SPI connections to the OSU for temperature monitoringA1P...A8P Alarm inputs of the SUEAM Negative operating voltage for alarm contactsO64IN_A/B,O64OUT_A/B

Overhead 64 kbit/s from LTx, plug-in place 209

Pin X143

Connector T3out

X144

Connector T3in

1 GND_S GND_S

2 T3 OUT1 a T3 IN1 a

3 T3 OUT1 a

4 T3 OUT2 a T3 IN2 a

5 T3 OUT2 a

6 T3 OUT1 b T3 IN1 b

7 T3 OUT1 b

8 T3 OUT2 b T3 IN2 b

9 T3 OUT2 b

Tab. 3.8 SNUS 9-Contact Jacks X120, X143 and X144

GND Operation groundGND-S Shielded groundT3OUT_A1,.T3OUT_B1 T3 output from the CUC plug-in placesT3OUT_A2, T3OUT_B2 T3 output from the CUDT3 IN1 a, T3 IN1 b T3in1 input to the CUD-, LTx- and CUC plug-in placesT3 OUT1 a, T3 OUT1 b T3in1 output for forwardingT3 IN2 a, T3 IN2 b T3in2 input to the ADMT3 OUT2 a, T3 OUT2 b T3in2 output for forwarding

Page 55: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 55

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

ZA-Contacts (X122), ECC of CUC/CUD (X131), V.11 of ADM (X138) andExternal PCI-Interfaces of CUC (X112 and X132)

Signal Abbreviations

Pin X122

ZA-contacts

X131

ECC of the CUCs

X138

V.11 of the ADM

X112

External PCI interfaces of

the CUC1

X132

External PCI interfaces of

the CUC2

1 GND_S GND_S GND_S GND_S GND_S

2 EIN_A1 V11ETXD_A1 PCI_D_P9 PCIS_D_P9

3 ZAA2 EOUT_A1 V11ETXD_B1 PCI_U_P9 PCIS_U_P9

4 ZAA3 ET_A1 V11ERXD_A1 GND GND

5 ZAA4 EIN_A2 V11ERXD_B1 PCI_D_P10 PCIS_D_P10

6 ZAA5 EOUT_A2 V11ETXD_A2 PCI_U_P10 PCIS_U_P10

7 ZAA6 ET_A2 V11ETXD_B2 GND GND

8 ZAA7 EIN_A3 V11ERXD_A2 PCI_D_P11 PCIS_D_P11

9 ZAA8 EOUT_A3 V11ERXD_B2 PCI_U_P11 PCIS_U_P11

10 ZAA9 EIN_A4 V11ETXC_A GND GND

11 EOUT_A4 V11ETXC_B PCI_D_P12 PCIS_D_P12

12 EINCUD_A V11ERXC_A PCI_U_P12 PCIS_U_P12

13 GND EOUTCUD_A V11ERXC_B CCUR_A CCURS_A

14 ZAB1 EIN_B1 V11WTXD_A1 PCI_D_N9 PCIS_D_N9

15 ZAB2 EOUT_B1 V11WTXD_B1 PCI_U_N9 PCIS_U_N9

16 ZAB3 ET_B1 V11WRXD_A1 GND GND

17 ZAB4 EIN_B2 V11WRXD_B1 PCI_D_N10 PCIS_D_N10

18 ZAB5 EOUT_B2 V11WTXD_A2 PCI_U_N10 PCIS_U_N10

19 ZAB6 ET_B2 V11WTXD_B2 GND GND

20 ZAB7 EIN_B3 V11WRXD_A2 PCI_D_N11 PCIS_D_N11

21 ZAB8 EOUT_B3 V11WRXD_B2 PCI_U_N11 PCIS_U_N11

22 ZAB9 EIN_B4 V11WTXC_A GND GND

23 EOUT_B4 V11WTXC_B PCI_D_N12 PCIS_D_N12

24 EINCUD_B V11WRXC_A PCI_U_N12 PCIS_U_N12

25 GND EOUTCUD_B V11WRXC_B CCUR_B CCURS_B

Tab. 3.9 SNUS Connectors X122, X131, X138, X112 and X132

GND Operation groundGND-S Shielded groundIndex 1 SUEIndex 2 CUDIndex 3...5 LTx plug-in placesIndex 6, 7 CUCsIndex 8 PSDIndex 9 OTSU2MEAN/AB_A/B1 to A/B4 ECC1 to ECC4 of both CUCs

Page 56: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

56 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Line cards (X103 to X108 and X123 to X128) and LTx (X107, X108 and X111)

EAN/ABCUD_A/B ECC of the CUDV11E EastV11W WestTXC Transmit clockRXC Receive clockPCIS_D_Py/Ny (y = 1 to 12) Output from the CUCPCIS_U_Py/Ny (y = 1 to 12) Input from the CUC

Line cards LTx1 to LTx3 Modules of the LT2ME1

Pin X103 to X108 X123 to X128 X107, X108 and X111 Signal G703 Uk2 SDSL T4 2)

1 GND GND GND_S H1A1 E1IN_A1 E1IN_A1 SHDSL_A1 T4out_A

2 LC(y)A1_A1 LC(y)C1_A13 H1B2 (E1IN_B2)1) H1B1 E1IN_B1 E1IN_B1 SHDSL_B1 T4out_B

3 LC(y)A3_A2 LC(y)C3_A14 H2A1 E1OUT_A1 E1OUT_A1 SHDSL_C12)

4 LC(y)A7_A3 LC(y)C9_A15 H2B2 E1OUT_B21) H2B1 E1OUT_B1 E1OUT_B1 SHDSL_D12)

5 LC(y)A11_A4 LC(y)C13_A16 H1A2 E1IN_A2 E1IN_A2 SHDSL_A2 T4out_A

6 LC(y)A13_A5 LC(y)C17_A17 H1B2 E1IN_B2 E1IN_B2 SHDSL_B2 T4out_B

7 LC(y)A19_A6 LC(y)C19_A18 H2B1 E1OUT_B1 H2A2 E1OUT_A2 E1OUT_A2 SHDSL_C22)

8 LC(y)A23_A7 LC(y)C23_A19 H2B2 E1OUT_B2 E1OUT_B2 SHDSL_D22)

9 LC(y)A25_A8 LC(y)C25_A20 2) only with SDSL4op

10 LC(y)A29_A9 LC(y)C29_A21

11 LC(y)A31_A10 LC(y)C31_A22

12 LC(y)A15_A11 LC(y)C7_A23

13 LC(y)A17_A12 LC(y)C15_A24

14 LC(y)A2_B1 LC(y)C2_B13 H1A2 (E1IN_A2)1)

15 LC(y)A4_B2 LC(y)C4_B14

16 LC(y)A8_B3 LC(y)C10_B15 H2A2 E1OUT_A21)

17 LC(y)A12_B4 LC(y)C14_B16

18 LC(y)A14_B5 LC(y)C18_B17

19 LC(y)A20_B6 LC(y)C20_B18 H2A1 E1OUT_A1

20 LC(y)A24_B7 LC(y)C24_B19

21 LC(y)A26_B8 LC(y)C26_B20

22 LC(y)A30_B9 LC(y)C30_B21

23 LC(y)A32_B10 LC(y)C32_B22

24 LC(y)A16_B11 LC(y)C8_B23 H1A1 E1IN_A1

25 LC(y)A18_B12 LC(y)C16_B24 H1B1 (E1IN_B1)

1) The 2. interface exists only at X111

Tab. 3.10 SNUS Connectors X103 to X108, X123 to X128,X103, X123, X107, X108 and X111

Page 57: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 57

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Signal Abbreviations

Interfaces 2 Mbit/s G.703(PU16/1: X109, X129, X110, X130 and PU16/2: X113, X133, X114, X134)

The interfaces from X129 are port 5 to 8 of the PU16/1 in Slot 210 and are internal con-nected to the first 2-Mbit/s interface of the CUD place and of the 3 LTx plug-in places.The interfaces from X110 are port 9 to 12 and are internal connected with the ADM.The interfaces from X130 are port 13 to 16 and are internal connected with the ADM.

The interfaces from X133 are Port 5 to 8 of the PU16/2 in Slot 213 and are internal con-nected to the second 2-Mbit/s interface of the CUD and of the 3 LTx plug-in places.

GND Operation groundGND-S Shielded ground(y) y = 1...6e.g. LC2C1_A13

For LC1...LC6Signal from pin C1 of the line card 2A-wire from channel 13

Interfaces 2 Mbit/s G.703

Pin X109/X113 X129/X133 X110/X114 X130/X134

1 GND_S GND_S GND_S GND_S

2 E1 OUT1 a E1 OUT5 a E1 OUT9 a E1 OUT13 a

3 E1 IN1 a E1 IN5 a E1 IN9 a E1 IN13 a

4 E1 OUT2 a E1 OUT6 a E1 OUT10 a E1 OUT14 a

5 E1 IN2 a E1 IN6 a E1 IN10 a E1 IN14 a

6 E1 OUT3 a E1 OUT7 a E1 OUT11 a E1 OUT15 a

7 E1 IN3 a E1 IN7 a E1 IN11 a E1 IN15 a

8 E1 OUT4 a E1 OUT8 a E1 OUT12 a E1 OUT16 a

9 E1 IN4 a E1 IN8 a E1 IN12 a E1 IN16 a

10

11

14 E1 OUT1 b E1 OUT5 b E1 OUT9 b E1 OUT13 b

15 E1 IN1 b E1 IN5 b E1 IN9 b E1 IN13 b

16 E1 OUT2 b E1 OUT6 b E1 OUT10 b E1 OUT14 b

17 E1 IN2 b E1 IN6 b E1 IN10 b E1 IN14 b

18 E1 OUT3 b E1 OUT7 b E1 OUT11 b E1 OUT15 b

19 E1 IN3 b E1 IN7 b E1 IN11 b E1 IN15 b

20 E1 OUT4 b E1 OUT8 b E1 OUT12 b E1 OUT16 b

21 E1 IN4 b E1 IN8 b E1 IN12 b E1 IN16 b

24

25

Tab. 3.11 SNUS Connectors X109, X110, X 113, X114, X129,X130, X133, X134

Page 58: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

58 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

The interfaces from X114 are port 9 to 12 and are internal connected with the ADM.The interfaces from X134 are port 13 to 16 and are internal connected with the ADM.

Signal Abbreviations

Interfaces 2 Mbit/s G.703(TU: X115, X116, X117, X135, X136 and ADM: X137)

GND Operation groundGND-S Shielded groundE1 OUTy a and b (y = 1 to 16) A and B wire output 2 Mbit/s G.703 from port yE1 INy a and b (y = 1 to 16) A and B wire input 2 Mbit/s G.703 from port y

Interfaces 2 Mbit/s G.703

Pin X115 X135 X116 X136 X117 X137

1 GND_S GND_S GND_S GND_S GND_S GND_S

2 E1 OUT22 a E1 OUT26 a E1 OUT30 a E1 OUT34 a E1 OUT38 a E1 OUT17 a

3 E1 IN22 a E1 IN26 a E1 IN30 a E1 IN34 a E1 IN38 a E1 IN17 a

4 E1 OUT23 a E1 OUT27 a E1 OUT31 a E1 OUT35 a E1 OUT39 a E1 OUT18 a

5 E1 IN23 a E1 IN27 a E1 IN31 a E1 IN35 a E1 IN39 a E1 IN18 a

6 E1 OUT24 a E1 OUT28 a E1 OUT32 a E1 OUT36 a E1 OUT40 a E1 OUT19 a

7 E1 IN24 a E1 IN28 a E1 IN32 a E1 IN36 a E1 IN40 a E1 IN19 a

8 E1 OUT25 a E1 OUT29 a E1 OUT33 a E1 OUT37 a E1 OUT41 a E1 OUT20 a

9 E1 IN25 a E1 IN29 a E1 IN33 a E1 IN37 a E1 IN41 a E1 IN20 a

10 E1 OUT42 a E1 OUT21 a

11 E1 IN42 a E1 IN21 a

12

13

14 E1 OUT22 b E1 OUT26 b E1 OUT30 b E1 OUT34 b E1 OUT38 b E1 OUT17 b

15 E1 IN22 b E1 IN26 b E1 IN30 b E1 IN34 b E1 IN38 b E1 IN17 b

16 E1 OUT23 b E1 OUT27 b E1 OUT31 b E1 OUT35 b E1 OUT39 b E1 OUT18 b

17 E1 IN23 b E1 IN27 b E1 IN31 b E1 IN35 b E1 IN39 b E1 IN18 b

18 E1 OUT24 b E1 OUT28 b E1 OUT32 b E1 OUT36 b E1 OUT40 b E1 OUT19 b

19 E1 IN24 b E1 IN28 b E1 IN32 b E1 IN36 b E1 IN40 b E1 IN19 b

20 E1 OUT25 b E1 OUT29 b E1 OUT33 b E1 OUT37 b E1 OUT41 b E1 OUT20 b

21 E1 IN25 b E1 IN29 b E1 IN33 b E1 IN37 b E1 IN41 b E1 IN20 b

22 E1 OUT42 b E1 OUT21 b

23 E1 IN42 b E1 IN21 b

24

25

Tab. 3.12 SNUS Connectors X115 to X117, X135 to X137

Page 59: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 59

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Signal Abbreviations

D-Sub connectors X103 to X108 and X123 to X128 depending on the line card

GND Operation groundGND-S Shielded groundE1 OUTy a and b (y = 22 to 42) A and B wire output 2 Mbit/s G.703 from port 1 to 21

of the TUE1 INy a and b (y = 22 to 42) A and B wire input 2 Mbit/s G.703 from port 1 to 21

of the TUE1 OUTy a and b (y = 17 to 21) A and B wire output 2 Mbit/s G.703 from port y of ADME1 INy a and b (y = 17 to 21) A and B wire input 2 Mbit/s G.703 from port y of ADM

CPF2 UAC68 SUB102, SLX102/E SLB62

Pin X103 to X108 X123 to X128 X103 to X108 X123 to X128 X103 to X108 X103 to X108

1 GND GND GND GND GND GND

2 SN0_AN_A SN2_AN_A F2IN_A1 F2IN_A4 SB_A1 SB_A1

3 SN0_CNTL_A SN2_CNTL_A F2OUT_A1 F2OUT_A4 SB_A2

4 SN0_AB_A SN2_AB_A F2IN_A2 F2IN_A5 SB_A3 SB_A2

5 SN0_XCLK_A SN2_XCLK_A F2OUT_A2 F2OUT_A5 SB_A4 SB_A3

6 SN0_IND_A SN2_IND_A F2IN_A3 F2IN_A6 SB_A5

7 SN0_SCLK_A SN2_SCLK_A F2OUT_A3 F2OUT_A6 SB_A6 SB_A4

8 SN1_AB_A SN3_AB_A S2IN_A1 S2IN_A4 SB_A7

9 SN1_AN_A SN3_AN_A S2OUT_A1 S2OUT_A4 SB_A8 SB_A5

10 SN1_CNTL_A SN3_CNTL_A S2IN_A2 S2IN_A5 SB_A9

11 SN1_XCLK_A SN3_XCLK_A S2OUT_A2 S2OUT_A5 SB_A10 SB_A6

12 SN1_IND_A SN3_IND_A S2IN_A3 S2IN_A6

13 SN1_SCLK_A SN3_SCLK_A S2OUT_A3 S2OUT_A6

14 SN0_AN_B SN2_AN_B F2IN_B1 F2IN_B4 SB_B1 SB_B1

15 SN0_CNTL_B SN2_CNTL_B F2OUT_B1 F2OUT_B4 SB_B2

16 SN0_AB_B SN2_AB_B F2IN_B2 F2IN_B5 SB_B3 SB_B2

17 SN0_XCLK_B SN2_XCLK_B F2OUT_B2 F2OUT_B5 SB_B4 SB_B3

18 SN0_IND_B SN2_IND_B F2IN_B3 F2IN_B6 SB_B5

19 SN0_SCLK_B SN2_SCLK_B F2OUT_B3 F2OUT_B6 SB_B6 SB_B4

20 SN1_AB_B SN3_AB_B S2IN_B1 S2IN_B4 SB_B7

21 SN1_AN_B SN3_AN_B S2OUT_B1 S2OUT_B4 SB_B8 SB_B5

22 SN1_CNTL_B SN3_CNTL_B S2IN_B2 S2IN_B5 SB_B9

23 SN1_XCLK_B SN3_XCLK_B S2OUT_B2 S2OUT_B5 SB_B10 SB_B6

24 SN1_IND_B SN3_IND_B S2IN_B3 S2IN_B6

25 SN1_SCLK_B SN3_SCLK_B S2OUT_B3 S2OUT_B6

Tab. 3.13 SNUS Connectors X103 to X108, X123 to X128 (Part 1)

Page 60: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

60 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

I8S0P I4UK2NTP, I4UK4NTP IUL82C, IUL84C

Pin X103 to X108 X123 to X128 X103 to X108 X103 to X108

1 GND GND GND GND

2 S0A1 S0A5 Uk0_A1 D2A1

3 S0C1 S0C5 D2A2

4 S0A2 S0A6 Uk0_A2 D2A3

5 S0C2 S0C6 D2A4

6 S0A3 S0A7 D2A5

7 S0C3 S0C7 Uk0_A3 D2A6

8 S0A4 S0A8 D2A7

9 S0C4 S0C8 D2A8

10

11 Uk0_A4

12

13

14 S0B1 S0B5 Uk0_B1 D2B1

15 S0D1 S0D5 D2B2

16 S0B2 S0B6 Uk0_B2 D2B3

17 S0D2 S0D6 D2B4

18 S0B3 S0B7 D2B5

19 S0D3 S0D7 Uk0_B3 D2B6

20 S0B4 S0B8 D2B7

21 S0D4 S0D8 D2B8

22

23 Uk0_B4

24

25

Tab. 3.14 SNUS Connectors X103 to X108, X123 to X128 (Part 2)

Page 61: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 61

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

CM64/2 DSC104C DSC6-nx64C

Pin X103 to X108 X123 to X128 X103 to X108 X123 to X128 X103 to X108 X123 to X128

1 GND GND GND GND GND GND

2 D2OUT_A1 D2IN_A1 D2OUT_A1

3 D2OUT_A2 D2IN_A2 T21_A1 D2IN_A1

4 D2OUT_A3 D2IN_A3 T22_A1

5 D2OUT_A4 D2IN_A4 D2OUT_A2 D2IN_A2

6 D2OUT_A5 D2IN_A5 T21_A2

7 D2OUT_A6 D2IN_A6 T22_A2 D2IN_A3

8 D2OUT_A7 D2IN_A7 D2OUT_A3 D2IN_A4

9 D2OUT_A8 D2IN_A8 D2OUT_A4 D2IN_A5

10 D2OUT_A9 D2IN_A9 D2OUT_A5 D2IN_A6

11 D2OUT_A10 D2IN_A10 D2OUT_A6 TIN_A

12

13

14 F2IN_A F2IN_B D2OUT_B1 D2IN_B1 D2OUT_B1

15 F2OUT_A F2OUT_B D2OUT_B2 D2IN_B2 T21_B1 D2IN_B1

16 YOUT1_B D2OUT_B3 D2IN_B3 T22_B1

17 YOUT2_A YOUT2_B D2OUT_B4 D2IN_B4 D2OUT_B2 D2IN_B2

18 YOUT3_A YOUT3_B D2OUT_B5 D2IN_B5 T21_B2

19 YOUT4_A YOUT4_B D2OUT_B6 D2IN_B6 T22_B2 D2IN_B3

20 YIN1_A YIN1_B D2OUT_B7 D2IN_B7 D2OUT_B3 D2IN_B4

21 YIN2_A YIN2_B D2OUT_B8 D2IN_B8 D2OUT_B4 D2IN_B5

22 YIN3_A YIN3_B D2OUT_B9 D2IN_B9 D2OUT_B5 D2IN_B6

23 YIN4_A YIN4_B D2OUT_B10 D2IN_B10 D2OUT_B6 TIN_B

24

25

Tab. 3.15 SNUS Connectors X103 to X108, X123 to X128 (Part 3)

Page 62: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

62 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.1.9 Technical Data

3.1.9.1 Environmental Conditions

3.1.9.2 Foreign Voltage Protection

3.1.9.3 Power Supply

Environmental conditions acc. to ETS 300 019 (1992)

Operation Class 3.1acc. to ETS 300 019-1-3,(+5 °C to +40 °C)

Transport Class 2.3acc. to ETS 300 019-1-2,(−40 °C to +70 °C)

Storage Class 1.3Eacc. to ETS 300 019-1-1,(−45 °C to +45 °C)

Product safety acc. to EN 60950-1

Protection against external voltages on the outdoor subscriber lines (OTC applications)is implemented in 2 stages within the entire system. For further information see Section1.4.7 and UMN:IMN.

Classification for external voltage protection acc. to EN 300 386 V1.3.2 (05/2003)ITC applications according ITU-T K.20 (07/2003), basic1) levelOTC applications according ITU-T K.45 (07/2003), basic1) level

1) On enquiry, some line cards can also be used according enhanced level.

Compliance with the earth conditions according ITU-TIndoor applications (inside subscriber building) K.31 (03/1993)ITC applications (inside telecommunication building) K.27 (05/1996)Outdoor applications (remote electronic sites) K.35 (05/1996)

Units, which are not meet the requirements above, contain specific information aboutthe foreign power protection, see technical data of the line cards.

Rated input voltage −48 V /−60 VPermissible voltage range −36 V to −72 V

Page 63: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 63

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.2 FMX2S SubrackThe FMX2S is a subrack in 19“ construction, and can be adapted to the fitting conditionsfor the ETSI housing and racks using adapters.

Shelf FMX2S serves to accommodate the units of up to FMX2R3.2 multiplexers, up to6 x 2-Mbit/s line terminating units LTx as well as supervision unit SUE.

Fig. 3.12 Shelf FMX2S (without Front Panel)

The subrack can accept units in double Eurocard format, and has a backplane board toconnect the internal and external interfaces.

The FMX2S is equipped with a terminal panel which provides all external interfaces viathe corresponding sub-D connectors. The exceptions are the optical interfaces of thecorresponding units which are only present on the units themselves. For mechanicalrouting of the optical fibers the FMX2S is equipped with FO clips.

Different front panel connectors are intended to simplify matters wiring of the CPF2 datainterfaces with external data terminals, which can be plugged into an external Main Dis-tribution Field (MDF 180 or MDF 210), see UMN:IMN. For cabling the connectors in theterminal panel to the front panel connectors, the adapter cable S42023-A862-S11 hasto be used.

Also the 4 ethernet interfaces of one CIM-nx64E module are accessible at a front panelconnector. The connector also provides the RS232 interface. Also available at the frontpanel connector is a status LED.

Page 64: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

64 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.2.1 FittingThe FMX2S has 18 slots, which are fitted in the following way:

Fig. 3.13 FMX2S Equipping

2 3 4 5 6 7 8 9 10 11 12 13 1714 161

1) LT2ME1/LTO

3) optionally, if more than 6 LCs are to be connected to the CUD (slot 2)

1815

optional fitting

CU

D

LC 1

LC 2

LC 3

LC 4

LC 5

LC 6

CU

D

LC 1

LC 2

LC 3

LC 4

LC 5

LC 6LC

TS

UE LT

x 11)

LTx

21)

LTx

31)

LTx

42)

LTx

52)

LTx

62)

BE

C3)

2) LT2ME1/LTO

!For slots 8, 14 and 15, into which both channel cards and line termination units can beinserted, before the units are inserted the associated DIL switches must be checked,see Section 3.2.6.

Plug-in unit 1) Plug-in place Fil-

ter4)

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

V42

256-

Z82

-M1

V42

256-

Z82

-M2LC/LTx

LC1-

1

LC2-

1

LC3-

1

LC4-

1

LC5-

1

LC6-

1

LTx1

LC1-

2

LC2-

2

LC3-

2

LC4-

2

LC5-

2

LTx2

LC6-

2

LTx3

LTx4

LTx5

LTx6

Sub-D 2-wire (a, b)

or LTx

E1 E1 G1 H1 J1 K1 N1 P1 Q1 R1 S1 T1

M1 M1

Sub-D 4-wire (c, d)

or LTx

E2 F2 G2 H2 J2 K2

L2

N2 P2 Q2 R2 S2

L2

T2

M2 M2

SUE ×

CUD × ×

BEC ×

UAC68 × × × × × × × × × × × × ×

SUB102 × × × × × × × × × × × × ×

SLB62 × × × × × × × × × × × × ×

LLA102/104C × × × × × × × × × × × × ×

I8S0P × × × × × × × × × × × ×

I4UK2NTP × × × × × × × × × × × × ×

IUL82C × × × × × × × × × × × × ×

Tab. 3.16 FMX2S Equipping

Page 65: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 65

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.2.2 Clock Synchronization

Fig. 3.14 FMX2S Clock Distribution

IUL84C × × × × × × × × × × × × ×

I4UK4NTP × × × × × × × × × × × × ×

CM 64/2 × × × × × × × × × × × ×

SLX102/E × × × × × × × × × × × × ×

DSC104C × × × × × × × × × × × ×

DSC6nx64C × × × × × × × × × × × ×

CPF23) × × × × × × × × × × × × ×

LT2ME1 ×2) ×2) ×2) × × ×

LTO × × × × × ×

1) Pay attention to switch positions at equipping variants! 3) Up to 4 modules for CPF2: -CIM V.24, CIM X.21, CIM V.35, CIM V.36,

2) On these slots, only one module for copper transmission up to 2 modules CIM-nx64E

lines can be equipped:- Uk2mp, - G703sh, -SDSLmp, 4) Filter types according to LC types that must be plugged and

SDSLop, -SDSL4op, T4 module can be plugged screwed on to Sub D in terminal panel

optionally on plug-in places 216 to 218

Plug-in unit 1) Plug-in place Fil-

ter4)

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

V42

256-

Z82

-M1

V42

256-

Z82

-M2LC/LTx

LC1-

1

LC2-

1

LC3-

1

LC4-

1

LC5-

1

LC6-

1

LTx1

LC1-

2

LC2-

2

LC3-

2

LC4-

2

LC5-

2

LTx2

LC6-

2

LTx3

LTx4

LTx5

LTx6

Sub-D 2-wire (a, b)

or LTx

E1 E1 G1 H1 J1 K1 N1 P1 Q1 R1 S1 T1

M1 M1

Sub-D 4-wire (c, d)

or LTx

E2 F2 G2 H2 J2 K2

L2

N2 P2 Q2 R2 S2

L2

T2

M2 M2

Tab. 3.16 FMX2S Equipping (Cont.)

Levelconverter

CUD 2 LTx 4 LTx 5 LTx 6LTx 1 LTx 2 LTx 3CUD 1

T3o

ut

T3i

n

T3in 1

T3in 2T3o

ut 1

T3o

ut 2

T4o

ut 6

T4o

ut 5

120

ΩConnectors intermination panel

Page 66: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

66 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

A 2.048 MHz clock can be fed to T3in1 and T3in2 via a D-sub plug in the terminationpanel. The T3in1 clock supplies the line termination units and a level converter on thebackplane. A loop T3in2 supplies the two CUDs with the 2.048 MHz clock and passesthe clock on to external facilities.

At another D-sub connector in the termination panel, T3out can be extracted from thetwo CUDs, and T4out from LTx slots 5 and 6.

3.2.3 QD2 AccessThe internal wiring for operation and monitoring is shown in Fig. 3.15.

The TMN access for the subrack is the QD2 slave plug in the termination panel. Thisleads to the QD2 slave port 1 of the SUE. The T terminals of the SUE are also accessiblein the QD2 slave connector.

The internal QD2 bus can be connected via switches either to the QD2 master port ofthe SUE (in standalone operation of the subrack) or to QD2 access, e.g. from COMPS2within an ONU or SNU. In standalone operation, the QD2 bus connects the QD2 slaveinterfaces of the FMX2R3.2 to the QD2 master interface of the SUE supervision unit.

The QD2 slave port 2 is in the QD2-M connector. Via this port, one of the internal controlchannels can be connected using an appropriately assigned connector.

Fig. 3.15 FMX2S QD2 Access

The following internal control channels can be used:• ECC channels of SUE and CUD

– ECC 1 of SUE– ECC 2 of CUD 1 (slot 2)– ECC 3 of CUD 2 (slot 9)

• OH64 overhead channels of LTx 4 (slot 16) and LTx 6 (slot 18)

SUECUD LTx CUD LTx LTx LTx LTxLTx

QD

2-S

QD

2-M

EC

C

V.1

1

QD2 bus

QD2 bus

QD

2-S

2

QD

2-S

1 (T

)

QD

2-M

OH

64 4

S1 S2M

EC

C 1

EC

C 2

EC

C 3

OH

64 6

Connectors intermination panel

F IF(for LCT)

1 1 2 2 3 4 5 6

Page 67: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 67

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.2.4 AddressingAll units in this subrack, except SUE and CUD, are assigned slot addresses. For the ad-dresses which are assigned to the slots, see Section 3.2.6.

The SISA address of the SUE is set using the DIL switch in the termination panel.

The addresses of the CUDs are set using the DIL switch in the backplane.

For line termination units in line card slots, some address bits are given by the coding ofthe line cards. This makes it necessary to change address bits to adapt the addressing,if line termination units are installed in these slots. The change is done using DIL switch-es for fitting LCs or LTx, see Section 3.2.6.

3.2.5 Power SupplyThe −48 V input voltages are fed via two separate 3W3 plugs in the termination panel.The positive poles of both voltages are connected to each other and to the backplane,via a common filter and protection device, as the operating ground GND. The negativepoles of both voltages are filtered separately, and supply the units in the subrack asMUP1 and MUP2.

Whereas the SUE can be fed via its own reserve diodes from both voltages, the inputvoltages for the CUD and the line termination units are applied to the two voltages MUP1and MUP2 via reserve diodes on the backplane.

The line cards receive the required secondary voltages +5 V and –5 V from the CUD orBEC, and also, after protection on the CUD or BEC, the KZU voltage (MUKZU).

Without forced ventilation and with homogeneous distribution of heat sources in the sub-rack, about 105 W of power dissipation (1.25 W per 5.08 mm of basic grid) are permitted.

Fig. 3.16 FMX2S Power Supply

LTx 4 LTx 5 LTx 6CUD LTx 1 LTx 2 LTx 3

MUP 2

SUE

MUP 1

48 V

+48 V

+

CUD

Connectors intermination panel

EMCprotection

EMCprotection

EMCprotection

Page 68: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

68 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.2.6 Switch Settings

Fig. 3.17 FMX2S Front View without Front Panel

System 1

‹W

System 2LE

ECC

S100

QD2-S1+T-Port

ext.

48V/60V15po

l

15po

l

9pol

X102X101 X103

15po

l

X136X119

X141

48V/60V

X142

X21

8X

318

18

LT6

X21

7X

317

17

LT5

X21

6X

316

16

LT4

X21

5X

315

15

LC6-2LT3

X21

3X

313

13

LC4-2

X20

8X

308

8

LC6-1LT1

X20

1X

301

SUE

3W3

3W3

9pol

X120 X137

OHLT3LT5

ZA

25po

l

9pol

X138

HDSLLT1-3

X139

25po

l

X140

25po

l

HDSLLT4-6

a-row LC 1 to 6 system 1

X118

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

X123 X124

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

X125 X126 X128

25po

l

25po

l

25po

l

25po

l

X130 X131 X132

25po

l

X129

25po

l

25po

l

25po

l

25po

l

25po

l

25po

l

X133 X134 X135

c-row LC 1 to 6 system 1

a-row LC 1 to 6 system 2

c-row LC 1 to 6 system 2

T3ab

X10415

pol

PB

9pol

X121

X105 X106 X107 X108 X109 X112 X113 X114X111 X115 X116 X117

T3an25

pol

25po

l

X127

X110

E1LT3,4

E1LT1,2

E1LT5,6

E1CUD

SUE addresses

X21

0

X20

3X

303

LC1-1

16 8 4 2 1

QD2-S2QD2-Mo

X31

414

LC5-2LT2

X21

4

X20

2X

302

CUD

X20

4X

304

4

LC2-1

X20

5X

305

5

LC3-1

X20

6X

306

6

LC4-1

X20

7X

307

7

LC5-1

S20

8_1

4pol

X21

2X

312

12

LC3-2

X21

1X

311

11

LC2-2

X31

0

LC1-2

X20

9X

309

9

CUD-2BEC

ON

ON ON

ON

ON

ON ONON

ONON

ON

LTLCLTLC

LTLC

ON ONON

LTLCLTLC

Al. 1-3

4pol

S20

8_3

S20

8_4

8pol

S20

8_2

2pol

S30

94p

ol

S30

8_1

2pol

S30

8_2

2pol

ON

S30

18p

ol

S30

24p

ol

X40

3

X41

0

S21

5_2

2pol

S21

5_4

8pol

S21

5_3

4pol

S21

5_1

4pol

S21

4_2

2pol

S21

4_4

8pol

S21

4_3

4pol

S21

4_1

4pol

S31

52p

olS

314_

22p

olS

314_

12p

ol

ON

ON

S21

82p

ol

X310

Item

according to parts list

12

Slot SUB-D

25po

lS214_3 4-pin

Switch, 4-pin

Label:

Meaning:

Page 69: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 69

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Switch Adaptation to the Equipment in the FMX2

Backplane Addressing of the Units

All units in this subrack are assigned addresses via the backplane:

Switch What is switched Contacts Position, see also

Fig. 3.17

S100 ADR SUE: I4, I3, I2, I1, I0 5-pin In the terminal panel

S301 QD2S-IN-OUT-A-B [ONU/standalone] 8-pin Between X201 and X301

S302 ADR CUD1: A4_1 = GND, A3_1, A2_1, A1_1, A0_1 4-pin Between X202 and X302

S208_1 LC6*/LTx1*/QD2M 4-pin To the right of X208,above

S208_2 LC6*/LTx1*/T3IN 2-pin To the right of X208,below

S208_3 LC6*/LTx1*/SHDSL 4-pin To the right of X208,center

S208_4 LC6*/LTx1*/2MBit 8-pin To the right of X208,center

S308_1 ADR1A0 2-pin To the right of X307

S308_2 (PB2/LTK1) PB2LTK11 2-pin To the right of X307

S309 ADR CUD2: A4_2 = GND, A3_2, A2_2, A1_2, A0_2 4-pin Between X308 and X309

S214_1 LC5*/LTx2*/QD2M 4-pin To the right of X214,above

S214_2 LC5*/LT2*/T3IN 2-pin To the right of X214,below

S214_3 LC5*/LT2*/SHDSL 4-pin To the right of X214,center

S214_4 LC5*/LT2*/2MBit 8-pin To the right of X214,center

S314_1 ADR0A4 2-pin To the right of X314,below

S314_2 (PB2/LTK1) PB2LTK12 2-pin To the right of X314,center

S215_1 LC6*/LT3*/QD2M 4-pin To the right of X215,above

S215_2 LC6*/LT3*/T3IN 2-pin To the right of X215,below

S215_3 LC6*/LT3*/SHDSL 4-pin To the right of X215,center

S215_4 LC6*/LT3*/2MBit 8-pin To the right of X215,center

S315 (PB2/LTK1) PB2LTK13 2-pin To the right of X314,above

S218 T3INA/B_1, 120 Ohm termination 2-pin To the right of X218

Tab. 3.17 FMX2S Overview of the Switches

Address

setting

Unit model

SUE CUD1 CUD2 LT

Address type Variable Variable Variable Fix,

slot address

Address width 5 Bit 5 bit

(MSB on GND

5 Bit

(MSB on GND

Address type QD2 (SISA)

address

Unit address Unit address Unit address

Tab. 3.18 FMX2S Address Settings for the Units

Page 70: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

70 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Switching Over Addresses for Slots 208, 214 and 215

Slot 208

The following applies to slot 208 (also see Fig. 3.17):• Address switch S308_1 for LTx operation set to 'ON' (right)• Address switch S308_1 for LC operation set to 'OFF' (left)

Slot 214

The following applies to slot 214 (also see Fig. 3.17):• Address switch S314_1 for LTx operation set to 'ON' (right)• Address switch S314_1 for LC operation set to 'OFF' (left)

Slot 215• No address switching is necessary for slot 215.

S301: FMX2S Operating Mode

Address switch S100

in the terminal panel

S302

in the terminal panel

S309

in the terminal panel

None

As-delivered

condition

0-0-1-0-0 (stand-alone)

0-0-0-1-0

(stand-alone)

0-1-0-0-1

-

Address

setting

Unit model

SUE CUD1 CUD2 LT

Tab. 3.18 FMX2S Address Settings for the Units

iImportant advice for LTx addresses.Since line cards and LTXs can be inserted into slots 208, 214 and 215, addresses mustalso be switched here manually, in order to ensure the correct address detection.

12

11

10

9

5

6

7

8

QD2MOUT_A1

QD2MOUT_B1

QD2MiN_A1

QD2MiN_B1

16

15

14

13

1

2

3

4

QD2SIN_A

QD2SIN_B

QD2SOUT_A

QD2SOUT_B

QD2SIN_A1

QD2SIN_B1

QD2SOUT_A1

QD2SOUT_B1

S301ON

161

152

Standalone

143

134

125

116

107

98

As-delivered condition: Standalone

Page 71: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 71

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

S100: SUE Address

S302: CUD Address Switch in the 1st System

S309: Switch for the CUD Address in the 2nd System

S308_1: Address Adaptation for LC/LTx Equipping in Slot 208

109

12

I4I3

S100

GND

87

34

I2I1

65I0

ON10

1

9

2

Value

8

3

7

4

6

5

16 8 4 2 1

Example: Address = 4

As-delivered condition: Address 4

87

12

A3_1A2_1

S302

GND

65

34

A1_1A0_1

Address A4_1 (16)is on GND!

Closed = 'ON'

ON

81

72

63

54

Example: Address = 2

Value

8

4

2

1

As-delivered condition: Address 2

87

12

A3_1A2_1

S309

GND

65

34

A1_1A0_1

Address A4_2 (16)is on GND!

Closed = 'ON'

ON

81

72

63

54

Value

8

4

2

1

As-delivered condition: Address 9Example: Address = 9

ADR1A0

GND

S308_1

41

32

ON

41

32

ON

41

32

LTx1 LC

As-delivered condition: LC

Page 72: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

72 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

S308_2: Switching Internal Signals for LTx Shelf in Slot 208

S314_1: Address Adaptation for LC /LTx Equipping in Slot 214

S314_2: Switching Internal Signals if LTx is Used in Slot 214

S315: Switching Internal Signals if LTx is used in Slot 215

(Warning! Switches turned!)

As-delivered condition: LC

S308_2

23

14

LTx1 LC

ON

4 1

3 2

ON

4 1

3 2PB2 X108 B10

PB2LTK11

Switching for LC 6-1 (PB2) or LTx1 (LTK1) in slot 8

ADR0A4

GNDAs-delivered condition: LC

S314_1

41

32

ON

41

32

ON

41

32

LTx1 LC

(Warning! Switches rotated!)

Switching for addresses for LC 5-2 or LTx2 in slot 14

(Warning! Switches rotated!)

S314_2

23

14

LTx1 LC

ON

4 1

3 2

ON

4 1

3 2PB2 X114 B10

PB2LTK12

As-delivered condition: LC Switch-over LC 5-2 (PB2) or LTx2 (LTK1) in slot 14

iWarning!The switch is used to switch over internal signals.If an LTx is used in slot 215, it must always be open!

(Warning! Switch rotated!)

S315

23

14

LTx1 LC

ON

4 1

3 2

ON

4 1

3 2PB2 X115 B10

PB2LTK13

As-delivered condition: LC Switch over LC 6-2 (PB2) or LTx3 (LTK1) in slot 15

Page 73: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 73

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

S218: T3in Terminator with 120 Ohm

S208_1: Adapting to LC /LTx Equipping in Slot 208

S214_1: Adapting to LC /LTx Equipping in Slot 214

41T3INA_1 T3INB_1

S218

120 Ohm termination closed = ON

121 Ohm

32

ON

41

32

120 OhmAs-delivered condition: Open

iWarning!If LTxs are used in slots 208, 214 and 215 (slots for LTx 1, LTx 2 and LTx 3), no linesmay be connected to the 25-pin X110, X117 and X118 sub-D-connectors and likewiseto X128, X135 and X136. This sometimes leads to the failure of the entire QD2 bus.

Separation of sub-D LC and QD2 bus;

If LC is used (open)

If LTx is used, closed = 'ON'

S208_1

LC208A2_1BQD2MIN_A1QD2MIN_B1QD2MOUT_A1QD2MOUT_B1

LC208C2_13BLC208A4_2BLC208C4_14B ON

81

72

ON

81

72

LC LTx

63

54

63

54

4321

5678

As-delivered condition: LC

iWarning!If LTxs are used in slots 208, 214 and 215 (slots for LTx 1, LTx 2 and LTx 3), no linesmay be connected to the 25-pin X110, X117 and X118 sub-D-connectors and likewiseto X128, X135 and X136. This sometimes leads to the failure of the entire QD2 bus.

Separation of sub-D LC and QD2Bus;

if LC is used (open)if LTx is used, closed = 'ON'

S214_1

LC214A2_1BQD2MIN_A1QD2MIN_B1QD2MOUT_A1QD2MOUT_B1

LC214C2_13BLC214A4_2BLC214C4_14B

ON

81

72

ON

81

72

LC LTx

63

54

63

54

4321

5678

As-delivered condition: LC

Page 74: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

74 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

S215_1: Adapting to LC /LTx Equipping in Slot 215

S208_2: Adapting to LC/LTx Equipping in Slot 208 (T3 clock feed)

S214_2: Adapting to LC /LTx Equipping in Slot 214 (T3 clock feed)

S215_2: Adapting to LC /LTx Equipping in Slot 215 (T3 clock feed)

iWarning!If LTxs are used in slots 208, 214 and 215 (slots for LTx 1, LTx 2 and LTx 3), no linesmay be connected to the 25-pin X110, X117 and X118 sub-D-connectors and likewiseto X128, X135 and X136. This sometimes leads to the failure of the entire QD2 bus.

Separation sub-D LC and QD2 bus;

If LC is used (open)

If LTx is used, closed = 'ON'

S215_1

LC215A2_1BQD2MIN_A1QD2MIN_B1QD2MOUT_A1QD2MOUT_B1

LC215C2_13BLC215A4_2BLC215C4_14B

ON

81

72

ON

81

72

LC LTx

63

54

63

54

4321

5678

As-delivered condition: LC

S208_243

12

LC208C30_21B T3INA_1T3INB_1LC208C32_22B

LC: OpenLTx1: Closed = 'ON'

Separation of sub-D LC and T3INA/B_1 if LTx is used

ON

41

32

ON

41

32

LC LTxAs-delivered condition: LC

S214_2

43

12

LC214C30_21B T3INA_1T3INB_1LC214C32_22B

L: Open

LTx1: Closed = 'ON'

Separation of sub-D LC and T3INA/B_1 if LTx is used

ON

41

32

ON

41

32

LC LTx

As-delivered condition: LC

S215_243

12

LC215C30_21B T3INA_1T3OUTB_1LC215C32_22B

LC: OpenLTx1: Closed = 'ON'

Separation of sub-D LC and T3INA/B_1 if LTx is used

ON

41

32

ON

41

32

LC LTx

As-delivered condition: LC

Page 75: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 75

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

S208_3: Adapting to LC /LTx Equipping in Slot 208

iWarning!If slot 208 is equipped with the LC card, the switch must be open to exclude any mutualfaults in the X139 (SHDSL) and X110 (LC 6, system 1) sub-D-connectors.

Switch separates lines from slot 208 to the X139 sub-D-connector

If LC is used (open)

If LTx is used, closed = 'ON'

S208_3

LC208A16_11B H1_A1_208ON

81

72

ON

81

72

LC LTx

63

54

63

54

LC208A18_12BLC208A20_6BH2_B_208

(E1OUT_B_208)

H1_B1_208H2_A1_208H2_B1_208

4321

5678

As-delivered condition: LC

(LTx1, LTx2, LTx3) f¸r SHDSL. (If equipped with LC

Page 76: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

76 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Overview of Switches S208_3, S214_3 and S215_3

LC 6 system 1(a contacts)

X110

Sub-D-connector

LC 5 System 2(a contacts)

a

SHDSL

LTx1

LTx2

LTx3

X139

25 pin

25 pin

25 pin

X117

LT1

LT3

LT2

10

231122

6

19 718

2

15 314

H1_A1_208

H2_B1_208H2_A1_208H1_B1_208

H1_A1_214

H2_B1_214H2_A1_214H1_B1_214

H1_A1_215

H2_B1_215H2_A1_215H1_B1_215

8

567

1

432

S208_3

8

567

1

432

S215_3

8

567

1

432

S214_3

LC 6 system 2 (a contacts)

a

25 pin

X118

X136 25 pinLC 6 system 2(c contacts)Not shown

24

19

2516A

20B18A

16B

LC208A16_11B

LC208A18_12B

20A

26B22A

24B

LC208A20_6B

H2_B_208 (E1OUT_B_208)

X208

External connector slot 8

Slot 8 LC 6 system 1 or LTx1

16A

20B18A

16B

LC214A16_11B

LC214A18_12B

20A

26B22A

24B

LC214A20_6B

H2B2_14 (E1OUT_B_214)

X214

Connector 14 LC 5 system 2

16A

20B18A

16B

LC215A16_11B

LC215A18_12B

20A

26B22A

24B

LC215A20_6B

H2B2_15 (E1OUT_B_215)

X215

Slot 15 LC 6 system 2

24

19

25

24

19

25

If LC is used, switch setting is open.If LTx is used, switch setting is closed = 'ON'.

IF LTx is used, (X110 and X128) and/or (X117 and X135) and/or

A clean separation at X139 is achieved by the switches if there is mixed LC and LTx

Either SHDSL and/or HDB3 can be outputted for each card

External connector slot 14

External connector slot 15

H1A1_1

H2B1_1H2A1_1H1B1_1

H1A1_2

H2B1_2H2A1_2H1B1_2

H1A1_3

H2B1_3H2A1_3H1B1_3

o LTx2or

or LTx3

(X118 and X136) cable must be removed!

equipping.

model used if LTx1, LTx2 and LTx3 are used!

X135 25 pinLC 5 system 2(c contacts)Not shown

X128 25 pinLC 6 system 1(c contacts)Not shown

Page 77: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 77

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

S214_3: Adapting to LC /LTx Equipping in Slot 214

S215_3: Adapting to LC/LTx Equipping in Slot 215

S208_4: Adapting to LC/LTx Equipping in Slot 208

iWarning!If slot 214 is equipped with the LC card, the switch must be open to exclude mutual faultsat the X139 (SHDSL) and X117 (LC 5, system 2) sub-D-connectors.

Separates lines from slot 214 to sub-D-connector X139

If LC is used (open)

If LTx is used, closed = 'ON'

S214_3

LC214A16_11B H1_A1_214

ON

81

72

ON

81

72

LC LTx

63

54

63

54

LC214A18_12BLC214A20_6BH2_B_214

(E1OUT_B_214)

H1_B1_214H2_A1_214H2_B1_214

4321

5678

As-delivered condition: LC(LTx1, LTx2, LTx3) for SHDSL. (If equipped with LC)

iWarning!If slot 215 is equipped with the LC card, the switch must be open to exclude mutual faultsat the X139 (SHDSL) and X118 (LC 5, system 2) sub-D-connectors.

If LC is used (open)

If LTx is used, closed = 'ON'

S215_3

LC215A16_11B H1_A1_208 ON

81

72

ON

81

72

LC LTx

63

54

63

54

LC215A18_12BLC215A20_6BH2_B_215

(E1OUT_B_215)

H1_B1_208H2_A1_208H2_B1_208

4321

5678

As-delivered condition: LC

Separates lines from slot 215 to the X139 sub-D-connector(LTx1, LTx2, LTx3) for SHDSL. (If equipped with LC)

If LC is used (open)

If LTx is used, closed = ‘ON’

S208_4

LC208A24_7B F2INB1_A2

4321

13141516

ON

161

152

LC LTx

143

134

LC208A26_8BLC208A30_9BLC208A32_10B

F2INB1_B2F2INA1_A1F2INA1_B1

125

116

107

98

ON

161

152

143

134

125

116

107

98

8765

9101112

LC208C24_19BLC208C26_20BF2OUT1_A1F2OUT1_B1

F2OUTB1_A2F2OUTB1_B2F2OUTA1_A1F2OUTA1_B1

IN2

IN1

OUT2

OUT1

IN / OUT from LT1

Separates lines from slot 208 to sub-D-connector X129

As-delivered condition: LC

(LTx1, LTx2) for 2MBit (E1). (If equipped with LC)

iWarning!IF slot 208 is equipped with LC, the switch must be open to exclude mutual faults at theX129 (2Mbit-E1), X110 and X128 sub-D-connectors (both LC 6, system 1).

Page 78: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

78 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Overview of the S208_4 and S214_4 Switches

LC 6 system 1 (a contacts)

X110

Sub-D-connector

E1

(2MBit)

LTx1

LTx2

X129

25 pin

25 pin

LT1

LT2

3

164

15

214

F2INA1_A1

F2OUTB1_B2F2OUTB1_A2F2INA1_B1

F2OUTA1_A1F2OUTA1_B1

14

111213

3

654

S208_4

109

78

20 IN24A

26A

LC208A24_7B

LC208A26_8B

30A

32A

LC208A30_9B

LC208A32_10B

X208

External connector slot 8

Slot 8 LC 6 system 1 or LTx1

If LC is used, switch setting is open.If LTx is used, switch setting is closed = 'ON'.

If LTx is used, (X110 and X128)and/or (X117 and X135) cable must be removed!

A clean separation at X129 is achieved by the switches if

Either SHDSL and/or HDB3 can be outputted for each cardmodel used if LTx1 and LTx2 are used!

22

21

23

LC 6 system 1 (c contacts)

X128

25 pin

20 OUT24C

26C

LC208C24_19B

LC208C26_20B

30C

32C

LC208C30_21B

LC208C32_22B22

21

23

28A

28B/28C

F2OUT1_A1

F2OUT1_B15

17F2INB1_A2F2INB1_B2

1615

12 IN2

IN1

OUT2

OUT1

20

7198

219

F2OUTB2_B2

F2INA2_A1F2INA2_B1F2OUTB2_A2

F2INB2_B2F2INB2_A2

14

111213

3

654

109

78

186

F2OUTA2_B1F2OUTA2_A1

1615

12 OUT1

OUT2

IN1

IN2

S214_4 LC 5 System 2 (a contacts)

X117

25 pin.

20 IN

22

21

23

LC 5 system 2 (c contacts)

X135

25 pin

20 OUT

22

21

23

24A

26A

LC214A24_7B

LC214A26_8B

30A

32A

LC214A30_9B

LC214A32_10B

X214

Slot 14 LC 5 system 2 or LTx2

24C

26C

LC214C24_19B

LC214C26_20B

30C

32C

LC214C30_21B

LC214C32_22B

28A

28B/28C

F2OUT2_A1

F2OUT2_B1

External connector slot 14

there is mixed LC and LTx equipping.

Page 79: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 79

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

S214_4: Adapting to LC /LTx Equipping in Slot 214

S215_4: Adapting to LC /LTx Equipping in Slot 215

iWarning!If slot 214 is equipped with LC, the switch must be open to exclude faults to the X129(2Mbit-E1), X117 and X135 sub-D-connectors (both LC 5, system 2).

If LC is used (open)

If LTx is used, closed = 'ON'

S214_4

LC214A24_7B

F2OUTA2_B1

4321

13141516

ON

161

152

LC LTx

143

134

LC214A26_8BLC214A30_9BLC214A32_10B

F2OUTA2_A1F2OUTB2_B2F2OUTB2_A2

125

116

107

98

ON

161

152

143

134

125

116

107

98

87

65

910

1112

LC214C24_19BLC214C26_20BF2OUT2_A1F2OUT2_B1

F2INA2_B1F2INA2_A1F2INB2_B2F2INB2_A2

IN2

IN1

OUT2

OUT1

IN / OUT from LT2

As-delivered condition: LC

(LTx1, LTx2) for 2MBit (E1). (If equipped with LC)Separates lines from slot 214 to sub-D-connector X129

iWarning!IF slot 215 is equipped with the LTx card, the switch must be open to exclude mutualfaults to the X130 (SHDSL), X118 and X136 (LC 6, system 2) sub-D-connectors.

If LC is used (open)If LTx is used, closed = 'ON'

S215_4

LC215A24_7B F2INB3_A2

4321

13141516

ON

161

152

LC LTx

143

134

LC215A26_8BLC215A30_9BLC215A32_10B

F2INB3_B2F2INA3_A1F2INA3_B1

125

116

107

98

ON

161

152

143

134

125

116

107

98

8765

9101112LC215C24_19B

LC215C26_20BF2OUT3_A1F2OUT3_B1

F2OUTB3_A2F2OUTB3_B2F2OUTA3_A1F2OUTA3_B1

IN2

IN1

OUT2

OUT1

IN / OUT from LT3

As-delivered condition: LC

Separates lines from slot 214 to sub-D-connector X129(LTx3, LTx4) for 2MBit (E1). (If equipped with LC)

Page 80: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

80 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.2.7 Connector Assignment

LC-Connectors (General)

Pin Assignment

(A)

Assignment

(C)

Remark

1 GND GND This is valid for system 1:

2 LC(Y)A1-1A LC(Y)C1_13A Row C Row A

3 LC(Y)A3-2A LC(Y)C3_14A Comes from: Sub-D Sub-D

4 LC(Y)A7-3A LC(Y)C9_15A LC1 / 1 / X203 Y = 203 X123 X105

5 LC(Y)A11-4A LC(Y)C13_16A LC2 / 1 / X204 Y = 204 X124 X106

6 LC(Y)A13-5A LC(Y)C17_17A LC3 / 1 / X205 Y = 205 X125 X107

7 LC(Y)A19-6A LC(Y)C19_18A LC4 / 1 / X206 Y = 206 X126 X108

8 LC(Y)A23-7A LC(Y)C23_19A LC5 / 1 / X207 Y = 207 X127 X109

9 LC(Y)A25-8A LC(Y)C25_20A LC6 / 1 / X208 Y = 208 X128 X110

10 LC(Y)A29-9A LC(Y)C29_21A System 2

11 LC(Y)A31-10A LC(Y)C31_22A Comes from: Sub-D Sub-D

12 LC(Y)A15-11A LC(Y)C7_23A LC1 / 2 / X210 Y = 210 X131 X113

13 LC(Y)A17-12A LC(Y)C15_24A LC2 / 2 / X211 Y = 211 X132 X114

14 LC(Y)A2-1B LC(Y)C2_13B LC3 / 2 / X212 Y = 212 X133 X115

15 LC(Y)A4-2B LC(Y)C4_14B LC4 / 2 / X213 Y = 213 X134 X116

16 LC(Y)A8-3B LC(Y)C10_15B LC5 / 2 / X214 Y = 214 X135 X117

17 LC(Y)A12-4B LC(Y)C14_16B LC6 / 2 / X215 Y = 215 X136 X118

18 LC(Y)A14-5B LC(Y)C18_17B This is valid for system 1:

20 LC(Y)A20-6B LC(Y)C24_19B Row C Row A

21 LC(Y)A24-7B LC(Y)C26_20B Comes from: Sub-D Sub-D

22 LC(Y)A26-8B LC(Y)C30_21B LC1 / 1 / X203 Y = 203 X123 X105

23 LC(Y)A30-9B LC(Y)C32_22B LC2 / 1 / X204 Y = 204 X124 X106

24 LC(Y)A32-10B LC(Y)C8_23B LC3 / 1 / X205 Y = 205 X125 X107

25 LC(Y)A16-11B LC(Y)C16_24B LC4 / 1 / X206 Y = 206 X126 X108

(Y) must be replaced by the respective number of connector!

LC1to LC6 correspond to the LC plug-in places 1 to 6

A-Row from X105, X106, X107, X108, X109, X110, X113, X114, X115, X116, X117, X118

C-Row from X123, X124, X125, X126, X127, X128, X131, X132, X133, X134, X135, X136

Tab. 3.19 FMX2S LC Connectors (General)

!If LTx are used on the plug-in places 208, 214 and 215 (plug-in places for LTx1, LTx2and LTx3), it is not allowed to connect lines on the 25-contact Sub-D-Jacks X110, X117and X118 and on X128, X135 and X136.

Page 81: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 81

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

LC connectors A-row part 1

PIN General DSC6-nx64C DSC104C I4UK4NTP /

I4UK2NTP

UAC68

1 GND GND GND GND GND

2 LC(Y)A1_1A D2OUTA1 D2OUTA1 UK0a1 F2IN_A1

3 LC(Y)A3_2A T21A1 D2OUTA2 F2OUT_A1

4 LC(Y)A7_3A T22A1 D2OUTA3 UK0a2 F2IN_A2

5 LC(Y)A11_4A D2OUTA2 D2OUTA4 F2OUT_A2

6 LC(Y)A13_5A T21A2 D2OUTA5 F2IN_A3

7 LC(Y)A19_6A T22A2 D2OUTA6 UK0a3 F2OUT_A3

8 LC(Y)A23_7A D2OUTA3 D2OUTA7 S2IN_A1

9 LC(Y)A25_8A D2OUTA4 D2OUTA8 S2OUT_A1

10 LC(Y)A29_9A D2OUTA5 D2OUTA9 S2IN_A2

11 LC(Y)A31_10A D2OUTA6 D2OUTA10 UK0a4 S2OUT_A2

12 LC(Y)A15_11A S2IN_A3

13 LC(Y)A17_12A S2OUT_A3

14 LC(Y)A2_1B D2OUTB1 D2OUTB1 UK0b1 F2IN_B1

15 LC(Y)A4_2B T21B1 D2OUTB2 F2OUT_B1

16 LC(Y)A8_3B T22B1 D2OUTB3 UK0b2 F2IN_B2

17 LC(Y)A12_4B D2OUTB2 D2OUTB4 F2OUT_B2

18 LC(Y)A14_5B T21B2 D2OUTB5 F2IN_B3

19 LC(Y)A20_6B T22B2 D2OUTB6 UK0b3 F2OUT_B3

20 LC(Y)A24_7B D2OUTB3 D2OUTB7 S2IN_B1

21 LC(Y)A26_8B D2OUTB4 D2OUTB8 S2OUT_B1

22 LC(Y)A30_9B D2OUTB5 D2OUTB9 S2IN_B2

23 LC(Y)A32_10B D2OUTB6 D2OUTB10 UK0b4 S2OUT_B2

24 LC(Y)A16_11B S2IN_B3

25 LC(Y)A18_12B S2OUT_B3

Tab. 3.20 FMX2S Connectors X105 to X110, X113 to X118 (Part 1)

Page 82: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

82 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

LC connectors A-row part 2

PIN General CPF2 SLX102/E CM64/2

1 GND GND GND GND

2 LC(Y)A1_1A SN0_AN_A SB-A1

3 LC(Y)A3_2A SN0_CNTL_A SB-A2

4 LC(Y)A7_3A SN0_AB_A SB-A3

5 LC(Y)A11_4A SN0_XCLK_A SB-A4

6 LC(Y)A13_5A SN0_IND_A SB-A5

7 LC(Y)A19_6A SN0_SCLK_A SB-A6

8 LC(Y)A23_7A SN1_AB_A SB-A7

9 LC(Y)A25_8A SN1_AN_A SB-A8

10 LC(Y)A29_9A SN1_CNTL_A SB-A9

11 LC(Y)A31_10A SN1_XCLK_A SB-A10

12 LC(Y)A15_11A SN1_IND_A

13 LC(Y)A17-12A SN1_SCLK_A

14 LC(Y)A2_1B SN0_AN_B SB-B1 F2IN_A

15 LC(Y)A4_2B SN0_CNTL_B SB-B2 F2OUT_A

16 LC(Y)A8_3B SN0_AB_B SB-B3

17 LC(Y)A12_4B SN0_XCLK_B SB-B4 YOUT2_A

18 LC(Y)A14_5B SN0_IND_B SB-B5 YOUT3_A

19 LC(Y)A20_6B SN0_SCLK_B SB-B6 YOUT4_A

20 LC(Y)A24_7B SN1_AB_B SB-B7 YIN1_A

21 LC(Y)A26_8B SN1_AN_B SB-B8 YIN2_A

22 LC(Y)A30_9B SN1_CNTL_B SB-B9 YIN3_A

23 LC(Y)A32_10B SN1_XCLK_B SB-B10 YIN4_A

24 LC(Y)A16_11B SN1_IND_B

25 LC(Y)A18-12B SN1_SCLK_B

Attention! YOUT1_A from CM64/2 is not laid to the Sub-D-jack!

Tab. 3.21 FMX2S Connectors X105 to X110, X113 to X118 (Part 2)

Page 83: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 83

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

LC connectors A-row part 3

PIN General I8S0P SLB62 SUB102 IUL82C, IUL84C

1 GND GND GND GND GND

2 LC(Y)A1_1A S0A1 F2A1 SB_A1 D2A1

3 LC(Y)A3_2A S0C1 SB_A2 D2A2

4 LC(Y)A7_3A S0A2 F2A2 SB_A3 D2A3

5 LC(Y)A11_4A S0C2 F2A3 SB_A4 D2A4

6 LC(Y)A13_5A S0A3 SB_A5 D2A5

7 LC(Y)A19_6A S0C3 F2A4 SB_A6 D2A6

8 LC(Y)A23_7A S0A4 SB_A7 D2A7

9 LC(Y)A25_8A S0C4 F2A5 SB_A8 D2A8

10 LC(Y)A29_9A SB_A9

11 LC(Y)A31_10A F2A6 SB_A10

12 LC(Y)A15_11A

13 LC(Y)A17_12A

14 LC(Y)A2_1B S0B1 F2B1 SB_B1 D2B1

15 LC(Y)A4_2B S0D1 SB_B2 D2B2

16 LC(Y)A8_3B S0B2 F2B2 SB_B3 D2B3

17 LC(Y)A12_4B S0D2 F2B3 SB_B4 D2B4

18 LC(Y)A14_5B S0B3 SB_B5 D2B5

19 LC(Y)A20_6B S0D3 F2B4 SB_B6 D2B6

20 LC(Y)A24_7B S0B4 SB_B7 D2B7

21 LC(Y)A26_8B S0D4 F2B5 SB_B8 D2B8

22 LC(Y)A30_9B SB_B9

23 LC(Y)A32_10B F2B6 SB_B10

24 LC(Y)A16_11B

25 LC(Y)A18_12B

Tab. 3.22 FMX2S Connectors X105 to X110, X113 to X118 (Part 3)

Page 84: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

84 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

LC connectors C-row part 1

Double assignments

PIN General DSC6-nx64C DSC104C I4UK4NTP /

I4UK2NTP

UAC68

1 GND GND GND GND

2 LC(Y)C1_13A D2INA1 F2IN_A4

3 LC(Y)C3_14A D2INA1 D2INA2 F2OUT_A4

4 LC(Y)C9_15A D2INA3 F2IN_A5

5 LC(Y)C13_16A D2INA2 D2INA4 F2OUT_A5

6 LC(Y)C17_17A D2INA5 F2IN_A6

7 LC(Y)C19_18A D2INA3 D2INA6 F2OUT_A6

8 LC(Y)C23_19A D2INA4 D2INA7 S2IN_A4

9 LC(Y)C25_20A D2INA5 D2INA8 S2OUT_A4

10 LC(Y)C29_21A D2INA6 D2INA9 S2IN_A5

11 LC(Y)C31_22A TINA D2INA10 S2OUT_A5

12 LC(Y)C7_23A S2IN_A6

13 LC(Y)C15_24A S2OUT_A6

14 LC(Y)C2_13B D2INB1 F2IN_B4

15 LC(Y)C4_14B D2INB1 D2INB2 F2OUT_B4

16 LC(Y)C10_15B D2INB3 F2IN_B5

17 LC(Y)C14_16B D2INB2 D2INB4 F2OUT_B5

18 LC(Y)C18_17B D2INB5 F2IN_B6

19 LC(Y)C20_18B D2INB3 D2INB6 F2OUT_B6

20 LC(Y)C24_19B D2INB4 D2INB7 S2IN_B4

21 LC(Y)C26_20B D2INB5 D2INB8 S2OUT_B4

22 LC(Y)C30_21B D2INB6 D2INB9 S2IN_B5

23 LC(Y)C32_22B TINB D2INB10 S2OUT_B5

24 LC(Y)C8_23B S2IN_B6

25 LC(Y)C16_24B S2OUT_B6

Tab. 3.23 FMX2S Connectors X123 to X128, X131 to X136 (Part 1)

Pin 7 Sub-D-A and Pin 20 Sub-D-C Pin 19 Sub-D-A and Pin 21 Sub-D-C

E1OUT2_A E1OUT2_B

Page 85: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 85

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

LC connectors C-row part 2

PIN General CPF2 SLX102/E CM64/2

1 GND GND n.b. GND

2 LC(Y)C1_13A SN2_AN_A

3 LC(Y)C3_14A SN2_CNTL_A

4 LC(Y)C9_15A SN2_AB_A

5 LC(Y)C13_16A SN2_XCLK_A

6 LC(Y)C17_17A SN2_IND_A

7 LC(Y)C19_18A SN2_SCLK_A

8 LC(Y)C23_19A SN3_AB_A

9 LC(Y)C25_20A SN3_AN_A

10 LC(Y)C29_21A SN3_CNTL_A

11 LC(Y)C31_22A SN3_XCLK_A

12 LC(Y)C7_23A SN3_IND_A

13 LC(Y)C15_24A SN3_SCLK_A

14 LC(Y)C2_13B SN2_AN_B F2IN_B

15 LC(Y)C4_14B SN2_CNTL_B F2OUT_B

16 LC(Y)C10_15B SN2_AB_B YOUT1_B

17 LC(Y)C14_16B SN2_XCLK_B YOUT2_B

18 LC(Y)C18_17B SN2_IND_B YOUT3_B

19 LC(Y)C20_18B SN2_SCLK_B YOUT4_B

20 LC(Y)C24_19B SN3_AB_B YIN1_B

21 LC(Y)C26_20B SN3_AN_B YIN2_B

22 LC(Y)C30_21B SN3_CNTL_B YIN3_B

23 LC(Y)C32_22B SN3_XCLK_B YIN4_B

24 LC(Y)C8_23B SN3_IND_B

25 LC(Y)C16_24B SN3_SCLK_B

Tab. 3.24 FMX2S Connectors X123 to X128, X131 to X136 (Part 2)

Page 86: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

86 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

LC connectors C-row part 3

PIN General I8S0P SLB62 SUB102 IUL82C, IUL84C

1 GND GND Not used Not used Not used

2 LC(Y)C1_13A S0A5

3 LC(Y)C3_14A S0C5

4 LC(Y)C9_15A S0A6

5 LC(Y)C13_16A S0C6

6 LC(Y)C17_17A S0A7

7 LC(Y)C19_18A S0C7

8 LC(Y)C23_19A S0A8

9 LC(Y)C25_20A S0C8

10 LC(Y)C29_21A

11 LC(Y)C31_22A

12 LC(Y)C7_23A

13 LC(Y)C15_24A

14 LC(Y)C2_13B S0B5

15 LC(Y)C4_14B S0D5

16 LC(Y)C10_15B S0B6

17 LC(Y)C14_16B S0D6

18 LC(Y)C18_17B S0B7

19 LC(Y)C20_18B S0D7

20 LC(Y)C24_19B S0B8

21 LC(Y)C26_20B S0D8

22 LC(Y)C30_21B

23 LC(Y)C32_22B

24 LC(Y)C8_23B

25 LC(Y)C16_24B

Tab. 3.25 FMX2S Connectors X123 to X128, X131 to X136 (Part 3)

Page 87: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 87

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Connectors X101 to X104 (SUE and ECC of CUDs)

Signal Abbreviations

PIN QD2 slave1 and T-Port

of the SUE

X101

QD2 slave2 and QD2-M

of the SUE

X102

Alarm inputs

of the SUE

X103

ECC of the

SUE and CUDs

X104

1 GND_S GND_S GND_S GND_S

2 QD2S1 OUT a QD2M IN a AIN1 ECC2 IN a

3 QD2T1 OUT a QD2S2 OUT a AIN3 ECC1 IN a

4 QD2S1 IN a QD2M OUT a AIN5 ECC2 OUT a

5 QD2T1 IN a QD2S2 IN a AIN7 ECC1 OUT a

6 ECC3 IN a

7 ECC3 OUT a

8 GND GND GND GND

9 QD2S1 OUT b QD2M IN b AIN2 ECC2 IN b

10 QD2T1 OUT b QD2S2 OUT b AIN4 ECC1 IN b

11 QD2S1 IN b QD2M OUT b AIN6 ECC2 OUT b

12 QD2T1 IN b QD2S2 IN b AIN8 ECC1 OUT b

13 ECC3 IN b

14 ECC3 OUT b

15 AM

Tab. 3.26 FMX2S Connectors X101 to X104

GND Operation groundGND-S Shielded groundQD2SIN_A1, B1, QD2SOUT_A1, B1 Slave 1 from the SUEQD2SIN_A2, B2, QD2SOUT_A2, B2 Slave 2 from the SUEQD2MIN A, B, QD2MOUT A, B Master interface from the SUEQD2TIN_A, B, QD2TOUT_A, B T-connections of slave1 from the SUEAIN1...AIN8 Alarm inputs of the SUEAM Negative operating voltage for alarm contactsECC1 IN A, B, ECC1 OUT A, B ECC from the SUEECC2 IN A, B, ECC2 OUT A, B ECC from the CUD 1, plug-in place 202ECC3 IN A, B, ECC3 OUT A, B ECC from the CUD 2, plug-in place 209

Page 88: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

88 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Connectors X119, X120, X121 and X138 (T3, OH)

Signal Abbreviations

PIN T3out

X119

T3in

X120 X121

Overhead (LTx4 and LTx6)

X138

1 GND_S GND_S GND_S GND_S

2 T3 OUT a1 T3 IN a2 PB0 O64 OUT a1

3 T4 OUT a5 T3 OUT a3 PB2 O64 IN a1

4 T3 OUT a2 T3 IN a1 O64 OUT a2

5 T4 OUT a6 O64 IN a2

6 T3 OUT b1 T3 IN b2 PB1 O64 OUT b1

7 T4 OUT b5 T3 OUT b3 PB3 O64 In b1

8 T3 OUT b2 T3 IN b1 O64 OUT b2

9 T4 OUT b6 O64 IN b2

Tab. 3.27 FMX2S Connectors X119 to X121 and X138

GND-S Shielded groundT3OUT_A1, B1 T3 output from the CUD1 plug-in places 2T3OUT_A2, B2 T3 output from the CUD2 plug-in places 9T3 IN a2, b2, T3 OUT a3, b3 T3-loops input or output CUD1T4 OUT a5, T4 OUT b5 T3-output from LTx5 plug-in place 17T4 OUT a6, T4 OUT b6 T3-output from LTx6 plug-in place 18T3 IN a1, T3 IN b1 T3-input to LT-plug-in placesO64 OUT a1...O64 IN b1 Overhead LTx4, plug-in place 16O64 OUT a2...O64 IN b2 Overhead LTx6, plug-in place 18

Page 89: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 89

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Connectors X139 and X140 (line interfaces)

Signal Abbreviations

PIN LTx places 1, 2, 3

X139

LTx places 4, 5, 6

X140

Signal Module

G.703

Module

Uk2

Module

SDSL

Module

T41)

1 GND_S GND_S H1A1 E1IN_A1 E1IN_A1 SHDSL_A1 T4ab_A

2 H1A1_3 H1A1_6 H1B1 E1IN_B1 E1IN_B1 SHDSL_B1 T4ab_B

3 H2A1_3 H2A1_6 H2A1 E1OUT_A1 E1OUT_A1

4 H1A2_6 H2B1 E1OUT_B1 E1OUT_B1

5 H2A2_6 H1A2 E1IN_A2 E1IN_A2 SHDSL_A2 T4ab_A

6 H1A1_2 H1A1_5 H1B2 E1IN_B2 E1IN_B2 SHDSL_B2 T4ab_B

7 H2A1_2 H2A1_5 H2A2 E1OUT_A2 E1OUT_A2

8 H1A2_5 H2B2 E1OUT_B2 E1OUT_B2

9 H2A2_5 1) only with SDSL4op

10 H1A1_1 H1A1_4

11 H2A1_1 H2A1_4

12 H1A2_4

13 H2A2_4

14 H1B1_3 H1B1_6

15 H2B1_3 H2B1_6

16 H1B2_6

17 H2B2_6

18 H1B1_2 H1B1_5

19 H2B1_2 H2B1_5

20 H1B2_5

21 H2B2_5

22 H1B1_1 H1B1_4

23 H2B1_1 H2B1_4

24 H1B2_4

25 H2B2_4

Tab. 3.28 FMX2S Connectors X139 and X140

GND-S Shielded groundH1A1_y, H1B1_yH2A1_y, H2B1_y(y = 1...6)

Interface 1 from LTx1...LTx6

H1A2_y, H1B2_yH2A2_y, H2B2_y(y = 1...6)

Interface 2 from LTx1...LTx6

e.g. H1A2_5...H2B2_5 Interface 2 from 5. LTx place

Page 90: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

90 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Connectors X111, X112, X129, X130 (2 Mbit/s G.703 CUD plug-in place 2, LTx)

PIN CUD place 2

X111

LTx5, LTx6

X112

LTx1, LTx2

X129

LTx3, LTx4

X130

Remark

1 GND_S GND_S GND_S GND_S

E1 OUT81 a/b: output of the 1. interface of LTx1

E1 IN81 a/b: input of the 1. interface of LTx1

E1 OUT82 a/b: output of the 2. interface of LTx1

E1 IN82 a/b: input of the 2. interface of LTx1

E1 OUT151 a/b: output of the 1. interface of LTx2

E1 IN151 a/b: input of the 1. interface of LTx2

E1 OUT152 a/b: output of the 2. interface of LTx2

E1 IN152 a/b: input of the 2. interface of LTx2

E1 OUT31 a/b: output of the 1. interface of LTx3

E1 IN31 a/b: input of the 1. interface of LTx3

E1 OUT32 a/b: output of the 2. interface of LTx3

E1 IN32 a/b: input of the 2. interface of LTx3

E1 OUT41 a/b: output of the 1. interface of LTx4

E1 IN41 a/b: input of the 1. interface of LTx4

E1 OUT42 a/b: output of the 2. interface of LTx4

E1 IN42 a/b: input of the 2. interface of LTx4E1

E1 OUT181 a/b: output of the 1. interface of LTx5

E1 IN181 a/b: input of the 1. interface of LTx5

E1 OUT182 a/b: output of the 2. interface of LTx5

E1 IN182 a/b: input of the 2. interface of LTx5

E1OUT191 a/b: output of the 1. interface of LTx6

E1IN191 a/b: input of the 1. interface of LTx6

E1OUT192 a/b: output of the 2. interface of LTx6

E1IN192 a/b: input of the 2. interface of LTx6

2 E1 OUT21 a E1 OUT181 a E1 OUT81 a E1 OUT31 a

3 E1 IN21 a E1 IN181 a E1 IN81 a E1 IN31 a

4 E1 OUT22 a E1 OUT182 a E1 OUT82 a E1 OUT32 a

5 E1 IN22 a E1 IN182 a E1 IN82 a E1 IN32 a

6 E1 OUT91 a E1 OUT191 a E1 OUT151 a E1 OUT41 a

7 E1 IN91 a E1 IN191 a E1 IN151 a E1 IN41 a

8 E1 OUT92 a E1 OUT192 a E1 OUT152 a E1 OUT42 a

9 E1 IN92 a E1 IN192 a E1 IN152 a E1 IN42 a

10

11

12

13

14 E1 OUT21 b E1 OUT181 b E1 OUT81 b E1 OUT31 b

15 E1 IN21 b E1 IN181 b E1 IN81 b E1 IN31 b

16 E1 OUT22 b E2 OUT182 b E1 OUT82 b E1 OUT32 b

17 E1 IN22 b E2 IN182 b E1 IN82 b E1 IN32 b

18 E1 OUT91 b E1 OUT191 b E2 OUT151 b E2 OUT41 b

19 E1 IN91 b E1 IN191 b E2 IN151 b E2 IN41 b

20 E1 OUT92 b E2 OUT192 b E2 OUT152 b E2 OUT42 b

21 E1 IN92 b E2 IN192 b E2 IN152 b E2 IN42 b

22

23

24

25

Tab. 3.29 FMX2S Connectors X111, X112, X129 and X130

Page 91: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 91

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Connector X137 (ZA-contacts)

Connectors X141, X142 (power supply connectors)

3.2.8 Technical Data

3.2.8.1 Environmental Conditions

Assignment PIN PIN Assignment Remark

GND_S 1 Shielded ground

2 14 ZA_301 ZA contact from SUE

ZAA_302 3 15 ZAB_302 ZA contact from CUD, plug-in place 2

ZAA_309 4 16 ZAB_309 ZA contact from CUD, plug-in place 9

ZAA_308 5 17 ZAB_308 ZA contact from LT1, plug-in place 8

ZAA_314 6 18 ZAB_314 ZA contact from LT2, plug-in place 14

ZAA_315 7 19 ZAB_315 ZA contact from LT3, plug-in place 15

ZAA_316 8 20 ZAB_316 ZA contact from LT4, plug-in place 16

ZAA_317 9 21 ZAB_317 ZA contact from LT5, plug-in place 17

ZAA_318 10 22 ZAB_318 ZA contact from LT6, plug-in place 18

11 23

12 24

GND 13 25 GND Operation ground

Tab. 3.30 FMX2S Connector X137

X141 X142

1 1

− 48 V (MUP 1) 2 − 48 V (MUP 2) 2

+ 48 V (GND) 3 + 48 V (GND) 3

Tab. 3.31 FMX2S Connectors X141 and X142

Environmental conditions acc. to ETS 300 019 (1992)

Operation Class 3.1acc. to ETS 300 019-1-3,(+5 °C to +40 °C)

Transport Class 2.3acc. to ETS 300 019-1-2,(−40 °C to +70 °C)

Storage Class 1.3Eacc. to ETS 300 019-1-1,(−45 °C to +45 °C)

Product safety acc. to EN 60950-1

Page 92: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

92 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.2.8.2 Foreign Voltage Protection

3.2.8.3 Power Supply

Protection against external voltages on the outdoor subscriber lines (OTC applications)is implemented in 2 stages within the entire system. For further information see Section1.4.7 and UMN:IMN.

Classification for external voltage protection acc. to EN 300 386 V1.3.2 (05/2003)ITC applications according ITU-T K.20 (07/2003), basic1) levelOTC applications according ITU-T K.45 (07/2003), basic1) level

1) On enquiry, some line cards can also be used according enhanced level.

Compliance with the earth conditions according ITU-TIndoor applications (inside subscriber building) K.31 (03/1993)ITC applications (inside telecommunication building) K.27 (05/1996)Outdoor applications (remote electronic sites) K.35 (05/1996)

Units, which are not meet the requirements above, contain specific information aboutthe foreign power protection, see technical data of the line cards.

Rated input voltage −48 V /−60 VPermissible voltage range −36 V to −72 V

Page 93: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 93

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.3 MXS19C Subrack

3.3.1 StructureThe shelf MXS19C can only be mounted in racks, shelter or housings according to in-stallation conditions of IEC 60297, the mounting width of MXS19C mechanics does al-low the installation in 19” racks.

There is no terminal panel. The shelf contains no front access connector panel, the con-nections will be realized via rear side located delivery connectors, see Fig. 3.18.

The shelf MXS19C can be equipped with plug-in units, realizing the following functions:• FMX2R3.2

– Central unit CUDThe CUD requires the FMX2R3.2 load.

– Narrowband linecards for voice, data and ISDN services• Line termination units, feeder or leased lines

– Access via copper cables with units LT2ME1for up to 16 E1 interfaces– Access via optical fiber (units LT2ME1, LTO/LT or LTO/NT) for up to 16 E1 inter-

faces.

The shelf MXS19C supports in maximum 120 subscriber ports that can be controlled byone or two CUDs.

Fig. 3.18 Shelf MXS19C with Front Cover

If line termination units with optical modules (LTO/LT or LTO/NT) are equipped in theMXS19C shelf, the shelf can be supplemented with a glass fiber guide. This guide willbe mounted immediately above the MXS19C shelf on the rack spars. The glass fibersof optical line termination units are guided upwards over a holding device. The centralfront cover can be removed without any release of the glass fiber connections.

The backplane of MXS19C contains an EEPROM to support remote inventory data. Themagament access will be realized by an internal SUE located on slot 201.

MXS19CSIEMENS

LASER KLASSE 1

LASER CLASS 1

ACHTUNG!LASER UND GLASFASER

MECHANISCHNICHT BELASTEN

ATTENTION!LASER AND GLASFIBER

MUST NOT BEPHYSICALLY DAMAGED

OR STRAINED

Page 94: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

94 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

Different front panel connectors are intended to simplify matters wiring of the CPF2 datainterfaces with external data terminals, which can be plugged into an external Main Dis-tribution Field (MDF 180 or MDF 210), see UMN:IMN. For cabling the transfer connec-tors to the front panel connectors, the adapter cable S42023-A799-S18 has to be used.

Also the 4 ethernet interfaces of one CIM-nx64E module are accessible at a front panelconnector. The connector also provides the RS232 interface. Also available at the frontpanel connector is a status LED.

Fig. 3.19 MXS19C Front View without Front Cover, Unequipped

Fig. 3.20 MXS19C Rear View

Connector forpower supply

Page 95: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 95

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.3.2 FittingThe MXS19C has 18 slots, which are fitted in the following way:

Fig. 3.21 MXS19C Equipping

201 210202 203 204 205 206 207 208 209 211 212 213 214 215 216 217 218

SU

E (

-B1)

LT LC/L

T

CU

D

CU

D/B

EC

SIS

AK

LT LC/L

T

LC/L

T

LC LC LC LC LC LC LC/L

T

LC/L

T

LC/L

T

Plug-in unit

Plug-in place

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

SUE (-B1) ×

CUD ×2) ×2)

BEC ×

SUB102 × × × × × × × × × × × ×

SLX102/E × × × × × × × × × × × ×

UAC68 × × × × × × × × × × × ×

SLB62 × × × × × × × × × × × ×

SEM106C × × × × × × × × × × × ×

SEM108HC × × × × × × × × × × × ×

LLA102/104C × × × × × × × × × × × ×

I8S0P × × × × × × × × × × × ×

I4UK2NTP × × × × × × × × × × × ×

IUL82C × × × × × × × × × × × ×

I4UK4NTP × × × × × × × × × × × ×

IUL84C × × × × × × × × × × × ×

CPF24) × × × × × × × × × × × ×

DSC6nx64C × × × × × × × × × × × ×

DSC104C × × × × × × × × × × × ×

LTO/LT × × × × ×1) × × ×

LTO/NT × × × × ×1) × × ×

LT2ME13) × × × × × × × ×

SISAK ×

1) If the LTO is plugged into slot 206 it is not possible to use the neighboring slot 207

2) The central units CUD required the FMX2R3.2 load.

3) Pluggable modules of the LT2ME1: UK2mp, G703sh, SDSLmp, SDSLop, SDSL4op optionally with T4 module

4) Pluggable modules of the CPF2: CIM V.24, CIM X.21, CIM V.35, CIM V.36, CIM-nx64E

Tab. 3.32 MXS19C Equipping

Page 96: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

96 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.3.3 E1 InterfacesEach CUD contains two E1 interfaces. The E1 interfaces of both CUDs can be accessedat connector X110, which is located on the rear side connector panel. The impedancesof the E1 interfaces are adjustable by switches on the CUD between 120 Ω balancedand 75 Ω unbalanced.

The E1 interfaces of line termination units on the slot delivery connectors have to beconnected with an external distribution frame via special cables, see Section 3.3.4.

To connect the 2-Mbit/s signals with 75 Ω coax cable, the b pin should be connected tothe shield of the coax cable (GND). It is necessary that no cable shield is connected tothe shield of the grip plate, because the voltage potential of the grip plate shield isGND_S.

For cross connection of the unbalanced cable or for changing from balanced to unbal-anced cable it is advisable to use the Coax Distribution Field (CDF) S42023-A890-A75.

3.3.4 Line Termination InterfacesThe slots 202, 203, 204, 205, 206, 215, 216 and 217 can be equipped with line termina-tion units. The backplane of the MXS19C supports any connections on these slots to themanagement interfaces. All needed connections are realized inside the shelf.

Each LTx and combined LC/LTx slot contains two 4-wire interfaces (E1 interfaces),which can be used for the different balanced line interfaces (SHDSL, Uk2). The interfac-es, available on the connectors X103, X104, X105, X106, X115, X116, and X117, haveto be connected according to the pin assignment of the line termination unit.

Fig. 3.22 External Interfaces of the Line Termination Units

Line

Unit

F2

QD2

T3an

E1

To the E1 distribution frame (DDF)

To the QD2 distribution frame

From external clock reference

LSA connecting strip forcopper line interfaces

Termination

Page 97: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 97

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

3.3.5 Elektro Magnetic CompatibilityThe following Table summarizes the possibilities to minimize EMC disturbances per slot.

Only for LT slots it is not necessary to equip the DIN 41612 connector with an EMC pla-nar filter because at these slots a shielded subscriber cable is used.

If a line card on the combined slots is used an EMC planar filter set, part numberS50034-H2-A1 can be equipped on the DIN 41612 connector in order to minimize EMCdisturbance.

3.3.6 TaktsynchronisationIn principle, the FMX2R3.2 will be operated synchronously. A plesiochronous operatingmode is not possible. An internal clock source will be need for alarming purposes (AIS).

The system clock of the multiplexer and the LTx will be derived from one of the followingclock sources:• One of the two E1 receive signals• The external reference clock T3in• An internal free-running oscillator on CUD.

Line card/LTx Shielded

subscriber cable

Unshielded

subscriber cable

With EMC planar

filter

Without EMC

planar filter

I8S0P x x

CPF2 x x

DSC6nx64C x x

DSC104C x x

LTO x x

LT2ME1 x x

UAC68 x x

SUB102 x x

SLX102/E x x

SLB62 x x

SEM106C x x

SEM108HC x x

LLA102/104C x x

IUL82C x x

IUL84C x x

I4UK2NTP x x

I4UK4NTP x x

SUE x x

SISAK x x

CUD x x

Tab. 3.33 Minimization of EMC Disturbances

Page 98: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

98 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

The distribution of the clock information to the peripheral linecards will be realized overthe PCM highway. The frame alignment on the peripheral units will be established byelastic stores.

The MXS19C provides a balanced clock input T3in via the common delivery connectorX101 for the T3 reference clock 2.048 MHz according to ITU-T G.703/13. By using theexternal reference clock T3in, both CUDs will be synchronized.

Both CUDs can derive a synchronization clock T4 from their receive signal to synchro-nize other functional units. The balanced clock signals T4_1 and T4_2 are connectedon the delivery connector X101.

Fig. 3.23 MXS19C Clock Distribution

3.3.7 QD2 AccessThe internal wiring for operation and monitoring is shown in Fig. 3.24.

The TMN access for the subrack is the QD2 slave interface on connector X101. Thisleads to the QD2 slave port 1 of the SUE. The T terminals of the QD2 slave interface 1of the SUE are also accessible in the QD2 slave connector. The SUE will be addressedvia a DIL switch on the backplane.

The multiplexer, including the various line cards, forms the network element FMX2R3.TMN access to the FMX2R3 is via the QD2 slave interface of the central unit withbitrates of 9.6 kbit/s or 64 kbit/s autodetect. The network element is fix addressed bybackplane coding, with five bits for the CUD central unit.

It is possible to share the linecards in the shelf to two network elements FMX2R3 byequipping a second central unit CUD. In this case, each CUD takes over the control ofthe half from the shelf. The QD2 slave ports of both CUDs are switched in parallel, eachCUD has its own QD2 address.

If one multiplexer with more than 6 line cards is needed, a BEC can be plugged-in at thesecond CUD slot. This BEC connects automatically the both PCM busses and feeds theline cards on the right hand side of the shelf with voltage.

The internal QD2 bus is a 4-wire interface based on EIA RS485. The master of the in-ternal QD2 bus can be a SISAV, located outside of the MXS19C, e.g. the OSU in aCOMPS2 shelf, or it is the SUE plugged into the MXS19C. By using the QD2 switchesS2 and S3 the internal QD2 bus can be connected to the QD2 master port of the SUE(S2 open, S3 closed) or to the QD2 slave port of the MXS19C (S2 closed, S3 open).

Levelconverter

CUD 1 LTx 6 LTx 8LTx 5 CUD 2LTx 1

T4

T3i

n12

X101X101

Page 99: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

A50010-A3-C701-1-7618 99

InformationFlexible Multiplexer FMX2R3.2

UMN:TED

Fig. 3.24 MXS19C QD2 Access

Fig. 3.25 QD2 Bus Switch-over

If the QD2 interface of the SISAK should be used, an external cable connection is nec-essary according to general cabling plan, see also Section 5.7.

The CUD can decouple an embedded control channel (ECC), which can be used fortransmission of management data. The ECC interfaces of both CUDs are led to the con-nector X101, where a connection to the SISAK can be established. A configured64-kbit/s time slot of one of the 4 possible E1 ports must be connected to the ECC port.

The shelf can be local operated via the F-interface of the SUE. The interface is acces-sible after removing the front cover.

SUE

QD2 slave

QD2 master

CUD#1

LCs

Operating system (OS)

Addr. 10

F

QD2-S

SISAV

SISA0

FMX2R3.2

SISA0

FMX2R3.2

SISA0

FMX2R3.2

CUD#2

LCs

Addr. 11

SISAV

SISA0

FMX2R3.2

SISA0

FMX2R3.2

SISA0

FMX2R3.2

SISAV

LT#1/LT

SISAV

LT#1/NT

SISAV

LT#8/LT

SISAV

LT#8/NT

SISAK

SISAV

SISAK

QD2 switchS2 and S3

Addr.-Switch1 ... 30

with SUEwithout SUE

Addr. xx Addr. xx

Addresses have to be seton the plug-in unit

Internal QD2 busQD2-S

Addr. SW1 ... 30

QD2-S

QD2-S

QD2-M

QD2SAN1 QD2SAB1Slave port 1

Masterport

QD2MIN

QD2MOUT

SUE

X101

QD2SOUT QD2SINSlave port

CUD/LTx

Internal QD2 bus

S2

S3

QD2SIN1QD2SOUT1

QD2SOUT

QD2SIN

Page 100: Informationimage.tantinh.net/domain/thietbicnphuongnam/FMX2R3_TED - 1.pdf · Information Flexible Multiplexer FMX2R3.2 ... 2.2.2 Central Unit CUD ... Flexible Multiplexer FMX2R3.2

100 A50010-A3-C701-1-7618

UMN:TED InformationFlexible Multiplexer FMX2R3.2

3.3.8 AddressingAll units in this shelf, except SUE and SISAK, are assigned the slot addresses as QD2addresses. For the addresses which are assigned to the slots, see Tab. 3.34.

The SISA address of the SUE is set using the DIL switch S101 in the backplane.

For line termination units in line card slots, some address bits are given by the coding ofthe line cards. This makes it necessary to change address bits to adapt the addressing,if line termination units are installed in these slots. The change is done using DIL switch-es, see UMN:LE2.

Unit Plug-in place Slot address

(fix)

QD2 address

SUE 201 DIL switch S101 on the backplane of

the shelf, see Fig. 3.27,

5 bit = 1 to 30

LTx#1 202 12 12

LTx#2 203 13 13

LC#1 204 1 -

LTx#3 204 16 16

LC#2 205 2 -

LTx#4 205 1 1

LC#3 206 3 -

LTx#5 206 17 17

LC#4 207 4 -

LC#5 208 5 -

LC#6 209 6 -

CUD 210 10 10

CUD/BEC 211 11 11

LC#7 212 1 -

LC#8 213 2 -

LC#9 214 3 -

LC#10 215 4 -

LTx#6 215 8 8

LC#11 216 5 -

LTx#7 216 24 24

LC#12 217 6 -

LTx#8 217 9 9

SISAK 218 set with LCT, see UMN:ITMN

Tab. 3.34 MXS19C Plug-in Units and Addresses