Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se.

Post on 15-Jan-2016

220 views 1 download

Tags:

Transcript of Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se.

www.univox.eu

Hearing Loop System

Conny Andersson

Standards IEC 60118-4

Sound examples

Conny.Andersson@edin.se

www.univox.eu

Hearing InstrumentReverberation time = 2 secSpeaker @ 4m distanceBabble noise (other speakers)Output from a Hearing Aid (artificial ear)

www.univox.eu

International Standards, IEC

Harmonized world wide

Hearing Instrument (HI)

Hearing Loop system

InternationalElectrotechnicalCommission

American NationalStandard Institute

www.univox.eu

IEC 60118-4, “Loop Standard”

Magnetic Field Strength = 400mA/m.

Relates directly to the output level of the Hearing Instrument

Coverage area/space (sitting and standing), +-3dB

www.univox.eu

Field distribution – level/coverage

Level: 400mA/m

Fluctuation: within +-3dB

www.univox.eu

Field distribution – level/coverage

(This slide contains the notes for the previous slide)

www.univox.eu

Frequency response

High frequency damping or metal loss is increased as a function of the distance to the loop wire. It cannot be fully compensated by the loop amplifier.

It can be compensated by the loop figuration.

www.univox.eu

No frequency limitations

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

www.univox.eu

High frequency loss from 1kHz

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

www.univox.eu

High frequency loss from 500Hz

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

www.univox.eu

No frequency limitations

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

www.univox.eu

Surrounding noise (hum)

Background noise (hum) from electrical appliances creates noise directly into the Hearing Instrument

Standard: less than -32dBA (-47dBA)

Level, Magnetic Field Strength 400mA/m

www.univox.eu

Background Noise (hum)High background noise: -12dBATiresome

www.univox.eu

Adding a weak amplifier Low Field Strength: -12dB (100mA/m)Very low speech intelligibility

www.univox.eu

Stronger amplifier – same noiseAccepted Field Strength: 0dB (400mA/m)Enhanced speech intelligibility

www.univox.eu

Approved field strength– same noiseAccepted Field Strength: +3dB (560mA/m)Further enhanced speech intelligibility

www.univox.eu

Complies to standardCorrect Field Strength: 0dB (400mA/m)Noise complies to the standard, -32dBA

www.univox.eu

High quality Loop SystemHigh Field Strength: +3dB (560mA/m)Noise complies to -47dBA

www.univox.eu

Conclusions of sound examples

Systems that sounds “noisy” is often a reflection of a weak hearing loop amplifier.

Loop systems could often easily be updated to comply with the level requirements (with increased Signal to Noise ratio and speech intelligibility).

www.univox.eu

Conclusion and adviseFollow the international standard

Do not trust the manufacturers coverage area as they are highly overstated for practical installations. Trust real measurements.

A hearing instrument cannot be used to certify a hearing loop system.

www.univox.eu

Thank you for your attention!