Wires & Cables - Siechem

Post on 16-Oct-2021

18 views 0 download

Transcript of Wires & Cables - Siechem

Wires & Cables

Area

Cond.Min.No.ofWires

Thicknessof EBXL /

XLPEInsulation

(Nom.)

ApproxOverall

diameter

Approx.NetWt.ofCable

Max.D.CResistanceat 20 deg.C

Current RatingFor EBXL -XLPECables (125°C)

Directin

Ground

Current RatingFor Chemically Cured XLPE Cables (90°C)

ShortCircuitRating

for 1secDirectin

Ground

Thicknessof PVCInner

Sheath

Dimensionof

ArmWire

Thicknessof

OuterSheath

Area

Cond.Min.No.ofWires

Thicknessof EBXL /

XLPEInsulation

(Nom.)

ApproxOverall

diameter

Approx.NetWt.ofCable

Max.D.CResistanceat 20 deg.C

Current RatingFor EBXL -XLPECables (125°C)

Directin

Ground

InDuct

InAir

Current RatingFor Chemically Cured XLPE Cables (90°C)

ShortCircuitRating

for 1 secDirect

inGround

InDuct

InAir

Sq.mm Nos mm mm Kg/Km Ω/KM

Dimensionof

Armstrips

Thicknessof

OuterSheath

mm mm Cu Cu Cu Cu Cu Cu Cu

Product Construction

Wires & Cables

üConductor : Annealed Plain copper conductor complying with BS 6360 üInsulation : Electron Beam Cross Linked Polyethylene 120°CüArmour : GI StripsüJacket : PVC Complying with BS 6746

Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467

Application

Features

Technical Data

üOperating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature üShort Circuit Temperature : 280°CüBending radius (min) : 12 x Cable diaüRated Voltage :600/1000 VüTest Voltage : 3.5 kV for 5 mins.üSpecification : BS 5467

PartNumber

749E3002

749E3202

749E3402

749E3702

749E3802

749E4102

749E4202

749E4402

749E4602

749E4802

749E4902

25

35

50

70

95

120

150

185

240

300

400

7

7

19

19

19

37

37

37

61

61

61

0.9

0.9

1.0

1.1

1.1

1.2

1.4

1.6

1.7

1.8

2.0

1.6

1.7

1.8

1.9

2

2.1

2.2

2.4

2.5

2.5

2.5

28.7

32.6

37.3

42.5

48.0

52.8

58.4

64.8

72.1

79.4

89.7

1274

1623

2068

2642

3341

4015

4813

5830

7148

8620

10895

3.6

5.0

7.1

10.0

13.6

17.1

21.4

26.4

34.3

42.9

57.1

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.9991

0.0754

0.0601

0.0470

198

234

273

343

408

451

511

576

660

745

803

178

211

255

309

368

417

472

530

606

683

770

173

203

281

317

387

432

495

576

680

770

872

152

180

210

264

314

347

393

443

508

573

618

137

162

196

238

283

321

363

408

466

525

592

133

156

216

244

298

332

381

443

523

592

671

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

0.8 X 4

üTransmission and distribution of Power Industrial unitsüCommercial and residential placesü Indoor and outdoor usesüCable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables.

üElectron Beam Cross Linked.üEnhanced Mechanical, Electrical, Thermal & Weathering properties.üSoldering iron resistantüResistance to corona effect.üEasy jointing & terminationüBetter resistance to most chemicals & acidsüLow direct electric losses.üHigh current carrying capacity.

Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467

Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement.

749E

Catalogue No

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

34

CM/L-6819184

IS : 7098 (Pt.1)IS : 7098 (Pt.1)

OHSAS 18001

AS 9100

ISO45001

ISO 9001

ISO 14001