TELSIMA SS IMPLEMENTATION
& TROUBLESHOOTING TRAINING
Data as on June,06 3Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
StarMAX Subscriber Station
Introduction
RF Coverage
Pole Location Selection
Pole and Antenna Mounting
Cabling & Connector Preparation
Antenna Direction Selection
Data as on June,06 4Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
STARMAX 2150 Subscriber Station
StarMAX 2150 Subscriber Station is outdoor version, designed for full outdoor operation. StarMAX 2150 Subscriber Station comes with anintegrated antenna, which is located under the cover of the unit. Entire StarMAX 2150 Subscriber Station is enclosed in a sealed, weather proof casing, suitable for outdoor wall mounting or pole mounting.
Data as on June,06 5Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Introduction StarMAX 2150 Subscriber Station
StarMAX 2150
Data as on June,06 6Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
RF Coverage
•Need to know what WiMAX network is planned for
Rooftop Coverage
Indoor Coverage
• How many Base Station are Visible (LOS or Near LOS) from the location ?
• Approximate distance from each BS Location
• Frequency of operation
• Targeted Throughput / Data rate
Data as on June,06 7Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
SS Visible from Single / Multiple Base Stations
Site K
Site A
SS Location
6Km
2.3Km
North
Obstruction
Site B
3Km
Data as on June,06 8Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Pole Mount Location
GI Pipe of 42 mm OD to be used of 1500 mm length
To be installed along the walls of the terrace or building
Preferably on rooftop with no immediate obstruction for 200 m
Also can be located at window tops or along the outside walls if no
access to rooftop
Need not be at the highest possible height always
Should be located in an area accessible to the technician
Data as on June,06 9Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Best Pole Mount / Antenna Location (Multipath Environment)
Refer to example above. Take the CINR & RSSI at all three possible locations.Compare RSSI and CINR at all the three locations.The location where best CINR is received, it should be finalized for installing pole and SS.
Data as on June,06 10Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
F1
F1
SSSS
SS ht increased-> signal from more than one BSRSSI<R1CINR<C1
SS getting signal from one BSRSSI (Receive signal strength Ind.)= R1CINR (Carrier to Interfernce+Noise Rejection Ratio)= C1
For SS more height is not always good
Site very far from SS location
Data as on June,06 11Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
SS Installed at Great Height is not always good
Customer Building Wimax Base Station
Subscriber Station
32 m
ete
r h
eig
ht8
0 m
ete
r heig
ht
•To achieve better link quality, place the Subscriber Station antenna at an optimum height.•When deciding the location of the Subscriber Station, take into account the location of the power outlet and your data equipment.
Data as on June,06 12Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Pole & Antenna Description- Identifying the Components
StartMAX SS Antanna.dwg
Data as on June,06 13Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Pole & Antenna Mounting
Step1: Secure the pipe to the parapet wall or lift room or any other
suitable place with “C” clamps. Make sure that pipe do not rotates in the C clamp.
Note that SS (Subscriber Station) can also be mounted on an
existing pipe.
To make sure that Antenna Base Bracket (ABB) orientation is right
for a given pole size and pole orientation, make a loose assembly of
all the parts of the bracket.
Once clear on what type of ABB orientation will be required tighten
the ABB to SS.
Grounding of the Pole Mount is must
Data as on June,06 14Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Ethernet input
TO SS
Rotate this bracket by
90 Deg for Vertical pipe
Data as on June,06 15Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Step2: Install the ABB as shown below.
Note that the ABB should be fixed after rotating by 90 degree compared to what is shown in the drawing.Precautions:
•The Elevation axis should be in parallel to the pole on which SS is to be mounted.
•The four bolts are of steel whereas the body of the enclosure is aluminium, a softer material. There is no threading on the bolt receptacle on the SS body. The bolts are to fixed by self-threading them.
•Ensure that bolts are aligned correctly or else the holes will get threaded unevenly. Use nut driver of proper size. Do not use spanner. Care needs to be taken to use the correct torque for tightening.
•Multiple removing and attaching brackets should be avoided, as this will damage the threads in the aluminium body.••There should not be any gap/play between bolt head and base bracket.
Data as on June,06 16Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Connector Preparation and Cabling
StarMAX SS 2150 connects to PoE box with CAT5e cable with RJ45
connector on both the sides
The connectivity from PoE box to SS port is Straight through
Supported Cable Length is 100 meter
PoE box to Customer Premise Equipment connectivity is auto negotiate
mode
It is important to check the continuity of the cable before plugging it into
PoE and StarMAX SS
CAT5e cable should be free of any sharp Bends and Twists for better
performance
Data as on June,06 17Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Installation Contd..
Grounding
Grounding of the Subscriber Station should be performed by following the steps:
Take M5x10 screw and a nut;
Fix the screw on the opening on the bottom of the Subscriber Station (next to the opening for the PoE cable)
Use a grounding cable no.10 (or 16 mm2)
Connecting the Equipment
Connect the Network Cable to RF+DC port on the PoE Module.
Connect the RJ-45 Network Cable to the RF port on the PoE Module.
Connect the other end of RJ-45 Network Cable to the RJ-45 port of your computer's Ethernet card or the adapter.
Connect the PoE Module to a standard electrical outlet.
Data as on June,06 18Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
SS 2150 Commissioning
SS Specifications
Check before Power ON
SS Config
SS Status
Data as on June,06 19Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Functional Description
Networking device
StarMAX 2100 series Subscriber Stations operate in the bridging mode. Their
primary function is L2 packet forwarding between the WiMAX interface and the
network interface. Access control lists, which may be applied to both WiMAX and
network interface are controlled by the StarMAX NMS network management
system.
Physical layer implementation
StarMAX 2100 series Subscriber Stations support IEEE 802.16 - 2004 standards
compliant physical layer with 256 OFDM/TDM/TDMA TDD operation. Supported
bands are 2.5, 3.3 and 3.5 GHz. Supported frame lengths are 5 ms, 8 ms, 10 ms,
12,5 ms and 20 ms. Supported frame splits are from 70:30 to 20:80 (uplink versus
downlink). Supported bandwidths are 3 MHz, 3.5 MHz, 5 MHz, 6 MHz, 7 MHz 10
MHz. Channel bandwidth is settable is steps of 250 kHz. Part of the standard PHY
layer implementation is adaptive modulation support.
Data as on June,06 20Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
MAC layer implementationStarMAX 2100 series Subscriber Stations support IEEE 802.16 -2004 standards compliant mandatory MAC layer implementation with packet convergence sublayer and common part sublayer. This includes core MAC layer functionality with control of duplexing, framing, PDU formation and header/subheader insertion.
Security Sublayer implementationStarMAX Subscriber Stations support PKM - V1 protocol for network authentication/security. PKM - V1 is determined by the cryptographic suite, which consists of the set of supported algorithm for encryption, authentication and TEK encryption. The supported cryptographic suite is supported:
Functional Description contd…..
Data as on June,06 21Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Authentication
TEK encryption
Quality of service
.
File system
SNMP management support
System software update
Functional Description contd…..
Data as on June,06 22Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
System SpecificationsWiMAX specification IEEE 802.16-2004
Adaptive modulation 64QAM ¾, 64QAM 2/3, 16QAM ¾,
16 QAM ½, QPSK ¾, QPSK ½, BPSK ½
Tx Power Maximum +20 dBm
Rx Sensitivity -100 dBm
Working Temperature -40 to +55*C
Antenna Gain 18 dBi gain outdoor antenna
Weight in Kgs 2.9
Classes of service BE, nrt-PS
Software upgrade Yes, software upgradable "over the air", Fail safe
Data as on June,06 23Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Check Before Powering ON
Check the GND to NEUTRAL VOLTAGE in AC supply should be less than 1.5 Volt
Check that Network and RF cable are connected to PoE
as marked
Check the grounding of the SS unit
Data as on June,06 24Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Power ON and System Connection
Power on the Subscriber Station
Install the Java JRE package if it is not installed in PC
Java 1.5 JRE for subscriber station EMS (Element Network Management)
(for free download of Java software http://www.java.com/en/download/index.jsp)
The default LAN IP of the SS is 192.168.1.1/24
Configure your computer to the static IP address: 192.168.1.2 with
subnet as 255.255.255.0 with 192.168.1.1 as gateway
Telnet the IP 192.168.1.1,
Login : root, password: telsimawl
Data as on June,06 25Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Basic Parameters Configuration
Basic Parameters to be configured are
1. Spot Frequency (3.3, 3.5 GHz etc.)
2. Frequency BW (3, 7, 14 MHz etc.)
3. BS Connect Mode = Auto
4. NTP server IP
5. SNMP RO & RW Communities
Data as on June,06 26Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Detailed Procedure for Antenna Alignment
Identify the nearest base station and if one is visible. Roughly align the antenna in the direction of this BTS.Power on the SS. Connect LCT to SS and monitor the RSSI.Before attempting horizontal alignment please loose bolt connecting antenna bracket (item# 1) with arm bracket (item# 5). Otherwise knurls on both the items will get damaged. After alignment this bolt is to be tightened.Keep the SS (Antenna) almost vertical and looking towards the rough direction of BTS. Move the Antenna slowly in horizontal plane, clock wise for at-least 45 degree from the initial position and mark the maximum RSSI. Do not stop even if design RSSI is achieved at some point. The RSSI may increase and finally start decreasing and become almost zero when the antenna is at 45 degree.Move the antenna slowly anti-clock wise, again noting the maximum RSSI and bring it back to original position.Move the antenna slowly clock wise, noting the maximum RSSI, till antenna is about 45 degree from the initial position.Bring the antenna to maximum RSSI position and tighten the bolt as described in point (iii).It is advisable to do 2/3 seeps of antenna and then lock antenna on maximum RSSI in horizontal plan.Now Vertical alignment is to be carried out. The procedure of vertical alignment is same as horizontal alignment. The sweep of antenna may be restricted to 15 degree up and 15 degree down from initial position.
Similarly before attempting vertical alignment loose bolt connecting arm bracket (item#5) with wall/pole bracket (item#10). Otherwise knurls on both the items will get damaged. After alignment this bolt is to be tightenedThe SS is to be locked to maximum RSSI.
Data as on June,06 27Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
The log at Seawind 11th floor
Telsima_ss#show bs-------------------------------------------------------------------------------------------
------
BS-Name SectorId Frequency Bandwidth Status DL-Cinr DL-Rssi DL-Fec
Ptx
-------------------------------------------------------------------------------------------------
bs1 00:00:00:00:00:B2 3337000 3000 OPER 29.81 -54.09 qam64-rs-cc-3/4
8.06
bs2 00:00:00:00:00:B1 3340000 3000 -NA- 24.95 -57.63 -NA--NA-
-------------------------------------------------------------------------------------------------
Actual SS Configuration
Data as on June,06 28Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Telsima_ss#show running-configconfigure ip ftp username rootconfigure ip ftp password passwordconfigure user password root 6c684ee7e13a45ce6cconfigure user password support f85d86b51d5dafconfigure ntp server 128.250.36.2configure ntp enableconfigure ip address 192.168.1.1 255.255.255.0configure bs connect_mode autoconfigure bs connect bs1configure bs add 3337000 3000 bs1configure bs add 3340000 3000 bs2
Telsima_ss#show mac-address-tableFORWARDING TABLE ENTRIESUNKNOWN ADDRESSES broadcasted to all interfaces----------------------------------------------MAC ADDRESS INTERFACE----------------------------------------------0002739000f4 LOCAL
Data as on June,06 29Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Telsima_ss#show versionSystem Software VersionKernel
version 2.0.3creation date Feb 23 2007, 11:35:10build machine HERCULES
Applicationversion 2.0.3creation date Fri Feb 23 12:02:07 CEST 2007build machine hercules.
System Hardware Version--------------------------------------------------------------------------------DEVICE | HARDWARE VERSION--------------------------------------------------------------------------------StarMAX 2100 Subscriber Station |--------------------------------------------------------------------------------
Data as on June,06 30Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
SS Status and Provisioning
A three way handshake enables the entry of SS in the network
Communication is between SS, BS and PS server described in the next slide
Data as on June,06 31Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
StarMAX SS StarMAX BS StarMAX PS DHCP
Register Req.
Register ACK
OPERATIONAL STATE
Authorization
1st Network Entry
Network Re-entry
DHCP REQ.
DHCP ACK with IP Add.
WAIT FOR PROVISION
CREATE SF, QOS
ACCESS LIST, RADIO SETTINGS, FUTURE
PROVISIONED, NOT PROV. , PROV. WITH
WARNINGS
Data as on June,06 32Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Supported Modulation Schemes & Throughput analysis
13.09 Mbps
11.88 Mbps
8.73 Mbps
5.82 Mbps
4.37 Mbps
2.90 Mbps
2.18 Mbps
Max. Throughput(3.5MHz)
20QAM64 2/3
18.4QAM64 1/2
14.4QAM16 3/4
11.1QAM16 1/2
8.4QPSK 3/4
5.8QPSK 1/2
3.3BPSK
CINR Value (dB)Modulation Scheme
Data as on June,06 33Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
FEC code
(A higher CINR triggers the upgrade of the
FEC code)Hysteresis Margin
Protection Margin
Protection Margin
Protection Margin
Hysteresis Margin
(A lower CINR triggers
the downgrade of the FEC code)
Implementation CINR (BER=10-6)
CINR
BPSK 1/2 QPSK 1/2 QPSK 3/4
LINK ADAPTATION PARAMETRIZATION
Data as on June,06 34Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
2150 SS Troubleshooting
SS troubleshooting RF part
SS troubleshooting System Parts
Tools and Measurements
Data as on June,06 35Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Check the Antenna location/position/ Alarms at BS
Is there some obstruction within 150m at BS?
Can be building, tower, hoardings etc
Check the RF parameters at different locations at
probable SS antenna location
RSSI, CINR, Sectors,
Modulation
Look for the antenna location at SS where only 1 sector
coverage is available with RSSI>-85, CINR>8
Observe for few min/hrs………………..
Any new Element added/SW upgrade in the network
Approach for looking at SS problem: RF Perspective
Data as on June,06 36Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Approach for looking at SS problem: System Perspective
Data as on June,06 40Ver 01
www.gcl.in© Gemini Communication – Company Confidential Ver 1.0
Tools & Measurements
Required Tools for Installing a StarMAX SS are
A screwdriver, a pair of tongs, a spanner, a pole
Ethernet cable (straight) for connecting the Station to your data equipment.
A PC that is configured with an ethernet card or an adapter
Microsoft Windows or other OS
In some cases a spectrum analyser may also be required
Throughput Measurement:
Using iperf