Volcano W - Hajduken.hajduk.eu/uploads/wklady/Schematic diagram of water...Schematic diagram of the...

Post on 29-Jul-2020

1 views 0 download

Transcript of Volcano W - Hajduken.hajduk.eu/uploads/wklady/Schematic diagram of water...Schematic diagram of the...

Schematic diagram of the insert Volcano W with waterjacket in a open circuit

Schematic diagram of the insert Volcano Wwith water jacket in a closed circuit

1. Expansion vessel with filling fittings2. Circulation pump3. Control Unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Acumulation tank - Buffer10. Pressure valve (max. 2,5 bar)T- ThermometerM. Manometer

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Heat exchangerT- Thermometer

P1

P2

Volcano W

Volcano W

T

1

10

4

7

6

5

3

9

22

8

4

7

6

5

3

1

9

228

T

Wate

r su

pply

Exp

ansi

on p

ipe

G-1 1/2

Ove

rflo

w p

ipe

dia

mete

r m

in 2

5m

m

Outflow from cooler

Water supply

G-1G-1

Centr

al h

eatin

g s

upply

Central heating supply

return from central heating system

Return to water complex

G-1 G-1

Sew

age s

yste

m

G-1G-1

G-1G-1

G-1

Water supply

Sewage system

Return to water complex

central heatingsupply

Return from central heating system

solar

central heating installation supply

Hot water supply1/2

T1 P1 P2

T1 P1 P2

M.

P1 P2

T1

T1

Outflo

w fro

m c

oole

r

Volcano WL/WLH

Volcano WL/WLH

2

5

7

64

T

1

8

9

3

Wate

r su

pply

Sew

age s

yste

m

Retu

rn to w

ate

r co

mple

x

Centr

al h

eatin

g s

upply

Central heating supply

Return from centralheating system

G-1 1/2G-1 G-1

G-1

2

P1 P2

T

4

5

6

10

7

1M.

9

3

822

Water supply

Sewage system

G-1 1/2G-1

G-1

G-1

Hot water supply

Centrlal heating installation supply

solar

Return from centralheating system

central heatingsupply

P1P2

Return to water complex

T1 P1 P2Outflow from cooler

T1

T1

Schematic diagram of the insert Volcano WL/WLHwith water jacket in an open circuit

Schematic diagram of the insert Volcano WL/WLH with water jacket in a closed circuit

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve(VTC300)9. Heat exchangerT - Thermometer

1. Expansion vessel with filling fittings2. Circulation pump3. Control Unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperatire valve (VTC300)9. Acumulation tank - buffer10. Pressure valve (max. 2,5 bar)T - ThermometerM.-Manometer

Exp

ansi

on p

ipe

T1 P1 P2

Volcano WP/WPH

Volcano WP/WPH

T1

2

5

7

64

T

1

8

9

3W

ate

r su

pply

Sew

age s

yste

m

Return to water complex

Centr

al h

eatin

g s

upply

Central heatingsupply

Return from central heating system

G-1 1/2G-1

G-1

2

P1 P2

T

4

5

6

10

7

1

M.

9

3

822

Water supply

Sewage system

G-1 1/2G-1

G-1

G-1

Hot water supply

central heating installation supply

solar

Return from central system

central heating supply

P1P2

Return to water complex

10

G-1

Outflow from cooler

Schematic diagram of the insert Volcano WP/WPHwith water jacket in an open circuit

Schematic diagram of the insert Volcano WP/WPHwith water jacket in a closed circuit

1. Expansion vessel with a float2. Circulation pump3. Control unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Heat exchangerT - Thermometer

1. Expansion vessel with filling fittings2. Circulation pump3. Control Unit - regulator4. Temperature sensor5. Thermostatic valve6. Thermostatic valve capillary7. Cooler8. Temperature valve (VTC300)9. Acumulation tank - buffer10. Pressure valve (max. 2,5 bar)T - ThermometerM.-Manometer

T1 P1 P2

T1 P1 P2

T1

Exp

ansi

on p

ipie