Villas Dubai

Post on 11-Mar-2016

218 views 1 download

Tags:

description

Draft for Dubai Villas

Transcript of Villas Dubai

multilivingfabulous

villaresidenceARCHHOLL

dubai

multilivingfabulous

multilivingfabulous

textiling

multilivingfabulous

coloring

multilivingfabulous

living

multilivingfabulous

crystal concreting

multilivingfabulous

lightningshadowing

multilivingfabulous

crystal ornamenting

multilivingfabulous

CONCEPT DESIGN I

multilivingfabulous

rockymountain

multilivingfabulous

conceptRockyMountain

multilivingfabulous

floor plans

00

01

carport

entry

maid

livingloggia

diningkitchen

multilivingfabulous

floor plans

02

03

master bedroomloggia

family living

bedroomloggia

bedroomloggia

multilivingfabulous

RockyMountaintowerhouse

morning coffee

relaxsun-bath

welcoming drink

multilivingfabulous

rendering

multilivingfabulous

CONCEPT DESIGN II

multilivingfabulous

insideout

multilivingfabulous

conceptinsideout

multilivingfabulous

floor plan

10 m0 5

bedroomsprivate entry

Family|LivingDining|Kitchen

garagemaid

entry

atrium

multilivingfabulous

insideout atrium house

enjoy privacy

sleep well

spying birdsornamental

cooking

multilivingfabulous

rendering

multilivingfabulous

intrinsicvalues

multilivingfabulous

conceptintrinsicvalues

multilivingfabulous

floor plan

10 m0 5

bedroomsprivate entry

Family|LivingDining|Kitchen

atriumofficial entry

maid‘s roomgarage

multilivingfabulous

intrinsicvalues atrium house

homeparty

welcome yourguests

having dinnermorning coffee

multilivingfabulous

rendering

außenraumvisualisierungüber eck

multilivingfabulous

ENERGY CONCEPTION

multilivingfabulous

temperatureregulation

Data source: The Senior Manager Meteorological Services Dubai Air Navigation Services P.O. Box 2525 Dubai United Arab Emirates, © 20010 Dubai Airports

Average Outdoor Temperature Min / Max1984 - 2009

0

5

10

15

20

25

30

35

40

45

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

°C

room temperature

heating

cooling

ESTIMATED ANNUAL ENERGYDEMAND

50% COOLING

40% HOT WATER

10% HEATING

multilivingfabulous

system overview

- every house is a ‚solar power plant‘

- local solar heating system for hot water

- central cooling withabsorption chiller and district cooling net

• EVERY HOUSE IS A „SOLAR POWER PLANT“

• LOCAL SOLAR HEATING SYSTEM FOR HOT WATER

• CENTRAL COOLING WITH ABSORPTION CHILLER AND DISTRICT COOLING NET

cooling circuit

heatingcircuit

solar panelsvakuum collectors

absorptioncooling unit

cooling tower

bu�er

12°C

90°C85°C

6°C

multilivingfabulous

system overviewdetail

VILLA TECHNICAL

BUILDINGphotovoltaik

multilivingfabulous

energy efficiency

cooling circuit

WATER IS USED AS NATURAL REFRIGARANT FLUID

ELECTRICAL CONNECTION APPR. 5 %

DISTRICT COOLING100 %

SOLAR ENERGY125 %

ABSORPTION CHILLERWITH THERMIC COMPRESSION

multilivingfabulous

Architekt DI. Hollaus ZT GmbHDI. Christoph Prem

Kirchplatz 13A-6112 Wattenstel:+43 5224 52 7 05fax:+43 5224 52 7 05-79arch@archholl.at

Moser & Partner Ingenierbüro GmbHGebäudetechnische Gesamtlösungen

Salzbergstraße 13A-6067 Absamtel:+43 5223 2212fax:+43 5223 204723office@moser-partner.at