Post on 23-Jan-2016
description
ACCESSORY BROCHURE UK and IrelandAugust 2015
www.trylon.com
ABOUT US
Anixter is a leading global supplier of communications and security products and electrical and electronic wire and cable. We help our customers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. Throughout the world, we provide innovative supply chain management solutions to reduce our customers’ total cost of production and implementation.
“ Anixter’s value to customers can be summed up in the depth and breadth of our inventory, application-specific technical and product knowledge, and a wide array of inventive Supply Chain Solutions mapped to our customers’ specific requirements.”
Bob Eck, President & CEO
ANIXTER IS A PROUD DISTRIBUTOR OF TRYLON PRODUCTS.
UNITED KINGDOM AND IRELAND
INDUSTRIALAberdeen Oil and Gas Tel: +44 (0)1224 275680
Birmingham Construction Tel: +44 (0)121 322 7140
Dublin Construction Tel: +353 1 257 2000
Glasgow Construction Tel: +44 (0)1698 503810
Uxbridge Construction Tel: +44 (0)845 604 1301
Warrington Construction Tel: +44 (0)1925 810121
Warrington Rail Tel: +44 (0)870 242 2822
anixter.co.uk
anixter.ie
OEMBarrow-in-Furness Tel: +44 (0)1229 825871
Chesterfield Tel: +44 (0)1246 451600
Coventry Tel: +44 (0)24 7646 5829
Diss Tel: +44 (0)1379 643506
Glasgow Tel: +44 (0)141 445 2193
Leeds Tel: +44 (0)113 244 0321
Liverpool Tel: +44 (0)151 355 2211
Luton Tel: +44 (0)1582 498900
Newcastle Tel: +44 (0)191 482 7660
Plymouth Tel: +44 (0)1752 341100
Portsmouth Tel: +44 (0)23 9286 5469
Sheffield Tel: +44 (0)1142 709300
Warrington Marine and Defence Tel: +44 (0)1925 816166
anixter.co.uk
FOR FURTHER INFORMATION CONTACT YOUR LOCAL ANIXTER REPRESENTATIVE.
PHONE, FAX, EMAIL WITH SALES REP
B2B INTEGRATION (E.G., EDI, JIT, ERP SYSTEMS)
EPROCUREMENTPUNCHOUT CATALOG(E.G., ARIBA, SCIQUEST)
CUSTOM CATALOG(E.G., INTELLIBID, ACCUBID)
ANIXTER.COM(RETAIL PRICING)
EANIXTER.COM(CONTRACT PRICING)
CUSTOMER BRANDED E-COMMERCE WEBSITE(CONTRACT PRICING)
PHYSICAL STORES ELECTRONIC INVOICES AND PAYMENTSCONSOLIDATED INVOICESTATEMENTS Major enhancements coming soon.
AUTOMATED ORDER CONFIRMATION AND SHIPMENT NOTIFICATION
eAnixter.com
DIFFERENT WAYS TO BUY FROM ANIXTER
GLOBAL REACH. LOCAL ADVANTAGE.With Anixter, you get a true local partner around the world. No other distributor of our kind can claim an in-country presence in more than 50 countries and 300 cities.
We do business in more than 35 currencies and 30 languages, which means we are uniquely positioned to help facilitate your project in the local environment, reduce risks and keep costs down.
CORPORATE SNAPSHOT
500,000PRODUCTS
OVER
50COUNTRIES
APPROXIMATELY
$$1.1 BILLIONINVENTORY
IN
300CITIES
STOCK SYMBOL
AXEFORTUNE
500 LIST
NUMBER OFEMPLOYEES
APPROXIMATELY 9,100
YEAR FOUNDED
1957APPROXIMATELY
100,000CUSTOMERS
270WAREHOUSES/
BRANCHES
Anixter Inc. World Headquarters2301 Patriot BoulevardGlenview, Illinois 60026224.521.8000
Wire & Cable EMEA HeadquartersUnit A, The BeaconsBirchwood ParkBirchwood, WarringtonCheshire, WA3 6GP+44 (0) 1925 838658
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 4
Mount Calcula on Example .........................................................................................................5
CE Product Cer fi ca on Example .................................................................................................6
Antenna/MW Standoff Mounts ...................................................................................................8
2-Way RRU Mount .......................................................................................................................9
3-Way RRU Mount .....................................................................................................................10
4-Way RRU Mount .....................................................................................................................11
Yoke Bracket Mount ..................................................................................................................12
Light Duty Wall Mount Assembly ...............................................................................................13
Wall Mount Assembly ...............................................................................................................14
Corner Mount Assembly ............................................................................................................15
Light Duty Roo op Mount .........................................................................................................16
Single Pipe Roof Ballast Mount ..................................................................................................17
Double Pipe Roof Ballast Mount ................................................................................................18
Pipe Extension Assembly ...........................................................................................................20
Step Bolt Assembly ....................................................................................................................21
3-Pipe 3-Sector Spine Mount .....................................................................................................22
6-Pipe 3-Sector Spine Mount .....................................................................................................23
Pole Ring Standoff .....................................................................................................................24
2-Level Pole Ring Standoff .........................................................................................................25
2L 6P Pole Ring Standoff ............................................................................................................26
Installa on Pages ......................................................................................................................27
Trylon Towers ............................................................................................................................46
TABLE OF CONTENTS
Table of Contents
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 5
MOUNT CALCULATION
EXAMPLE
Antenna/MW Standoff Mount (0.5m Pipe)
With Medium Backings Kit # 4.927.0108.001
21 South Field Drive, PO Box 186 Design Code: BS8100
Elmira, Ontario, Canada N3B 2Z6
519-669-5421 (ph), 519-669-8912 (fx)
INPUT VALUES
1) SITE AND TOWER PARAMETERS
Wind Speed* 24.0 m/s
Tower Height 60.0 m
Antenna Elevation* 60.0 m
Site Altitude 100 m
2) ANTENNA
Antenna Type* r (Flat,Round)
Height of Antenna* 1.50 m
Width of Antenna* 0.50 m
Weight of Antenna* 50.0 kg
3) MOUNT OPTIONS
Number of Mounting Angles* 1 (1 or 2)
OK!
Length of Horizontal Pipe* 0.5 m (0.5, 1, 2 or 3)
Backing* Medium (Medium, Small)
4) MAX ALLOWABLE ANTENNA DEFLECTION
Relative to tower/wall* 5.00 mm
SUMMARY of RESULTSDESIGNED TO: 24M/S WIND SPEED
(1) 1.5M x0.5M ANTENNAResults Capacity
Vertical Pipe Bend Check 500mm LONG x 76mm OD x 6mm THK [345MPa] 21.71 MPa 310.28 MPaPASS [1.7%]
Horizontal Angle Bend Check 64mm x 64mm x 6mm, 613mm LONG [300MPa] 228.79 MPa 273.04 MPaPASS [83.8%]
Backing Channel Bend Check 260mm LONG x 44mm WIDE x 57mm DEEP x 5mm THK [300MPa] 111.15 MPa 273.04 MPaPASS [40.7%]
Backing Rod Combined Shear & Tension CheckPASS [8.2%]
Tower Leg Reactions Per Backing Horizontal 1.35 kNVertical 0.63 kN
Torsional Moment 0.52 kN.mTotal mount Deflection 0.55 mm PASS
APPROX. MOUNT WEIGHT: 0.60 kN (Antenna and tower connection included)
Assumptions: - Areas calculated usings BS8100 guidelines - Quality Class: A - Design based on 50 year return basic wind speed - Terrain Category: III (Typ UK farmland) - Environment Conditions: Adjacent to Main Road - Checked Design for Member Stresses - Usage: Broadcasting - S values are calculated using std tables/formulas - Antenna centrally located on vertical Pipe - Atmospheric environment assumed to by Type (a) as per BS8100, cl. 3.1.1
ELEVATION VIEW
PLAN VIEW
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 6
CE PRODUCT CERTIFICATION
EXAMPLE
Declaration of Performance (according to REGULATION (EU) No 305/2011)
Kit Description: MW Standoff Mount (1m Pipe) Kit Part Number: 4.927.0103.001 DoP Number: 4.927.0103.001 Applicable Harmonized Standard: EN 1090-1:2009 Intended Usage: Antenna Support Mount Manufacturer Information: Trylon TSF 21 South Field Drive Elmira, Ontario Canada N2B 0A6 Tel: (519) 669 – 5421 Website: www.Trylon.com CE Marking Notified Body: SGS Italia S.p.A. Via G. Gozzi 1/a Milan, 20129 Italy Tel: +39 02 73 931 Website: www.sgsgroup.it/
System of assessment and verification of constancy of performance of the product: EXC2 Notified factory production control certification body No. 1381 performed the initial inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment, and evaluation of factory production control and issued the certificate of conformity of the factory production control Stephanie Berry Date: June 29, 2015 Director of Product Operations Trylon
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 7
CE PRODUCT CERTIFICATION
EXAMPLE
Identification No. 1381 of Notified Body Trylon TSF
21 South Field Drive Elmira, Ontario
Canada N2B 0A6
14 Kit Part #4.927.0103.001
Essential Characteristics Declared Performance Harmonized Technical Specification
Tolerances on dimensions and shape
In accordance with EN 1090-2 EN 1090-1:2009
Weldability Based in S355JR Material, Max CEV % is 0.543
Fracture toughness / brittle strength
As per EN 10025:2004 requirements for S275JR & S355JR steel - 27 J at 20° C
Impact resistance See Above.
Load bearing capacity As per EN-1993-3-1 (2007), Minimum capacity is 4.2kN
Deformation at serviceability limit state
As per EN-1993-3-1 (2007), Maximum deflection is 0.6mm
Fatigue strength NPD
Resistance to fire As per EN-13501-1, REI 180
Reaction to fire As per EN-13501-2, A1
Release of Cadmium and its compounds
NPD
Emission of Radioactivity NPD
Durability All products Galvanized to European EN ISO 1461
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 8
ANTENNA/MW STANDOFF
MOUNTS
NOTES: 1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 27 and page 28 for Installation Drawings
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Length of Pipe (0.5m) - Round / Flat
Allowable Antenna Loading
1.41 m2 1.23 m2 1.08 m2 1.26 m2 1.10 m2 0.96 m2
0.61 m2 0.52 m2 0.44 m2 0.54 m2 0.45 m2 0.39 m2
Length of Pipe (1m) - Round / Flat
3.95 m2 2.45 m2 2.15 m2 2.52 m2 2.19 m2 1.92 m2
1.24 m2 1.05 m2 0.89 m2 1.08 m2 0.91 m2 0.78 m2
Length of Pipe (2m) - Round / Flat
2.74 m2 2.39 m2 2.10 m2 2.46 m2 2.14 m2 1.87 m2
1.20 m2 1.02 m2 0.87 m2 1.05 m2 0.89 m2 0.76 m2
Length of Pipe (3m) - Round / Flat
2.67 m2 2.33 m2 2.05 m2 2.40 m2 2.08 m2 1.82 m2
1.17 m2 0.99 m2 0.85 m2 1.02 m2 0.86 m2 0.74 m2
Kit # Description Qty Weight 4.927.0108.001 MW Standoff Mount (0.5m Pipe) Each 13.2 kg
4.927.0103.001 MW Standoff Mount (1m Pipe) Each 24.5 kg
4.927.0103.002 MW Standoff Mount (2m Pipe) Each 36.0 kg
4.927.0103.003 MW Standoff Mount (3m Pipe) Each 47.7 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 9
2-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0110.001 2-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Each 13.5 kg
NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 29 for Installation Drawing
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 10
3-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0111.001 3-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 18.6 kg
NOTES: 1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models2) See page 30 for Installation Drawing
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 11
4-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0109.001 4-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 23.5 kg
NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 31 for Installation Drawing
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 12
YOKE BRACKET MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
3.93 m2 3.25 m2 2.73 m2 3.38 m2 2.79 m2 2.34 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 32 for Installation Drawing
Kit # Description Qty Weight
4.927.0102.001 2-Pipe Yoke Bracket Mount Each 77.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 13
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 33 for Installation Drawing
LIGHT DUTY WALL MOUNT
ASSEMBLY
Kit # Description Qty Weight
4.954.0012.001 Solid Light Wall Mount Assembly Each 13.5 kg
4.954.0012.002 Brick Light Wall Mount Assembly Each 11.7 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 14
WALL MOUNT ASSEMBLY
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
16.75 m2 13.88 m2 11.69 m2 14.47 m2 11.96 m2 10.05 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 34 for Installation Drawing
Kit # Description Qty Weight
4.954.0010.001 Solid Wall Mount Assembly Each 60.0 kg
4.954.0010.002 Brick Wall Mount Assembly Each 54.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 15
CORNER MOUNT ASSEMBLY
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
4.87 m2 4.27 m2 3.75 m2 4.38 m2 3.81 m2 3.34 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 35 for Installation Drawing
Kit # Description Qty Weight
4.954.0011.001 Solid Wall Corner Mount Assembly Each 37.0 kg
4.954.0011.002 Brick Wall Corner Mount Assembly Each 35.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 16
LIGHT DUTY ROOFTOP
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 0.48 m2 0.35 m2 0.26 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 36 for Installation Drawing
Kit # Description Qty Weight
4.951.0012.001 Light Duty Roof Ballast Mount Each 45.5 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 17
SINGLE PIPE ROOF BALLAST
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020 m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 2.61 m2 2.13 m2 1.76 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 37 for Installation Drawing
Kit # Description Qty Weight
4.951.0010.001 Single Pipe Roof Ballast Mount Each 205.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 18
DOUBLE PIPE ROOF BALLAST
MOUNT
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antennas assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 38 for Installation Drawing
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 4.12 m2 3.39 m2 2.82 m2
Kit # Description Qty Weight
4.951.0011.001 Double Pipe Roof Ballast Mount Each 297.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 19
• Rhino Tile is fi xed together using interlocking mechanism, no need for taping together
• Can be used inside or outside for temporary or semi-permanent applications
• Edging strip can be purchased separately and provide non-trip access where needed. Edging strip come in male or female formats
• Easy to cut to size with jigsaw or stanley knife
Guidelines for Use
Rhino Tile InformationMaterial PVC Tile
Size 500mm x 500mm 14 mmWeight 1.7kg per tileColor Black (Recycled) from stock
Fire & Heat Resistance UL 94 V-2Slip Resistance BS EN 7188
Recyclability 100% recycled and recyclableAnixter Part Numbers
SMMATM5000M5000000 Black Rhino Tile PVC-FRSMTILEM5000003 Yellow Rhino edging strip (male) SMTILEM5000004 Yellow Rhino edging strip (female)
Why Choose Rhino Tile• Interlocking mechanism, no need for tape• Extremely durable, absorbing impact and
shock• Perfect for heavy foot traffi c• Easy to cut if required• 100% Recycled• Easy to clean & can be used over and over
again
OPTIONAL ROOFMOUNT
ACCESSORY
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 20
PIPE EXTENSION ASSEMBLY
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) Assumed 0.2m Clamp Distance and 2m Extension Pipe.6) See page 39 for Installation Drawing
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
4.71 m2 3.90 m2 3.27 m2 4.04 m2 3.34 m2 2.81 m2
Kit # Description Qty Weight
4.927.0100.001 Pipe Extension Assembly Each 6.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 21
STEP BOLT ASSEMBLY
Kit # Description Qty Weight
4.918.0080.001 Step Bolt Assembly Each 3.0 kg
NOTES:1) See page 40 for Installation Drawing
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 22
3-PIPE 3-SECTOR SPINE
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 41 for Installation Drawing
Kit # Description Qty Weight
4.927.0104.001 3-Pipe, 3-Sector Spine Mount Each 156.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 23
6-PIPE 3-SECTOR SPINE
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 25.0 kg antenna weight per square meter of antenna area.5) See page 42 for Installation Drawing
Kit # Description Qty Weight
4.927.0105.001 6-Pipe, 3-Sector Spine Mount Each 223.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 24
POLE RING STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
5.80 m2 5.28 m2 4.84 m2 5.38 m2 4.89 m2 4.48 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 43 for Installation Drawing
Kit # Description Qty Weight
4.927.0101.001 Pole Ring Standoff Each 158.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 25
2-LEVEL POLE RING
STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
8.43 m2 6.97 m2 5.85 m2 7.23 m2 5.98 m2 5.02 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 44 for Installation Drawing
Kit # Description Qty Weight
4.927.0106.001 2-Level Pole Ring Standoff Each 316.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 26
2L 6P POLE RING STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
9.22 m2 7.62 m2 6.40 m2 7.91 m2 6.54 m2 5.49 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 45 for Installation Drawing
Kit # Description Qty Weight
4.927.0107.001 2L 6P Pole Ring Standoff Each 397.0 kg
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 27
ANTENNA/MW STANDOFF MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 28
ANTENNA/MW STANDOFF MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 29
2-WAY RRU MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 30
3-WAY RRU MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 31
4-WAY RRU MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 32
YOKE BRACKET MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 33
LIGHT WALL MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 34
WALL MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 35
CORNER MOUNT INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 36
LIGHT DUTY ROOF BALLAST MOUNT INSTALATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 37
SINGLE PIPE ROOF BALLAST MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 38
DOUBLE PIPE ROOF BALLAST MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 39
PIPE EXTENSION ASSEMBLY INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 40
STEP BOLT ASSEMBLY INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 41
\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0104.001 3-PIPE 3-SECTOR SPINE MOUNT.dwg, 8/10/2015 9:53:06 AM, cameronc
3-PIPE 3-SECTOR SPINE MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 42
\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0105.001 3-PIPE 6-SECTOR SPINE MOUNT.dwg, 8/10/2015 9:57:58 AM, cameronc
6-PIPE 3-SECTOR SPINE MOUNT INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 43
\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0101.001 POLE RING STANDOFF.dwg, 8/10/2015 9:47:05 AM, cameronc
POLE RING STANDOFF INSTALLATION PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 44
\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0106.001 2-LEVEL, 3-PIPE POLE RING STANDOFF.dwg, 8/10/2015 9:58:42 AM, cameronc
2-LEVEL POLE RING STANDOFF INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 45
\Sales\UK Product\Trylon UK Accessory CAD Installation Drawings\4.927.0107.001 2-LEVEL, 6-PIPE POLE RING STANDOFF.dwg, 8/10/2015 10:02:34 AM, cameronc
2L 6P POLE RING STANDOFF INSTALLATION
PAGE
21 South Field Drive, Elmira, Ontario, N3B 0A6 Tel: (519) 669-5421 Fax: (519) 669-8912 www.trylon.com 46
TRYLON TOWERS
SuperTITAN KD SPECIFICATIONS• Brand New Packaging Process
• Minimize freight costs (weight & dimensions)• Minimizes storage space• Improved economic footprint
• All members are hot-dip galvanized throughout• Designed to conform with CE standard• Maximum height: 57.9 meters• Sec on height: 3.0 meters
The SuperTitan KD is a modular tower that can be built up to 57.9 meters high. Consis ng of 21 standard sec ons, each 3.0 meters high, this modular system can be confi gured to create towers of varying heights and loading capaci es.
SuperTITAN MAX SPECIFICATIONS
• Tallest stock product tower off ered• Ships from Trylon• Designed to conform with CE Standards• Maximum height: 76.5 meters• Sec on height: 5.8 meters
Designed using the same basic modular confi gura on as the SuperTitanKD model, the SuperTitan MAX features a wide range of heights and op ons for increasing strength and capacity. The SuperTitan MAX is shipped in 5.8 meters sec ons which can be assembled to a maximum height of 76.5 meters, making it Trylon’s tallest self-suppor ng stocked tower.
www.trylon.com
TM, ®, ©, LOGOS, STYLIZED NAMES ARE TRADEMARKS OF TRYLON MANUFACTURING COMPANY LTD. © 2015 PRINTED IN CANADA
For further informa on please call your local Anixter representa ve. Contact informa on can be found
on page 2 of this brochure.