1
A
T
B
C
D
E
F
G
H
J
2
3
K
L
TOTAL AREA UNDER ROOF:
AREA TABULATION:
REAR COVERED PATIO:
TOTAL A/C:GARAGE:
FIRST FLOOR A/C:
4132 sq.ft.524 sq.ft.
294 sq.ft.
4999 sq.ft.
1954 sq.ft.SECOND FLOOR A/C: 2178 sq.ft.
FRONT PORCH: 49 sq.ft.
LOT COVERAGE:
PERCENTAGE OF COVERAGE:
LOT AREA
30 %
9183 sq.ft.HOUSE AREA 2821 sq.ft.
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
AutoCAD SHX Text
L = 60.00' R = 551.80'
AutoCAD SHX Text
148.08' S 16%%D51'08" E
AutoCAD SHX Text
135.62' N 12%%D37'34" W
AutoCAD SHX Text
70.67' S 81%%D31'49" W
AutoCAD SHX Text
30' B.L.
AutoCAD SHX Text
5' SIDE B.L.
AutoCAD SHX Text
5' SIDE B.L.
AutoCAD SHX Text
20' REAR B.L.
AutoCAD SHX Text
4' CONC.
AutoCAD SHX Text
15' ALLEY
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
2X CEILING JOISTS
AutoCAD SHX Text
2X4 SOFFIT FRAMING
AutoCAD SHX Text
1/2" MASONITE
AutoCAD SHX Text
SOFFIT W/ METAL VENT
AutoCAD SHX Text
2X6 RAFTERS
AutoCAD SHX Text
ROOFING ON
AutoCAD SHX Text
ON 16" CENTERS
AutoCAD SHX Text
7/16" OSB
AutoCAD SHX Text
2X4 CONT.
AutoCAD SHX Text
BLOCKING
AutoCAD SHX Text
PLATELINE
AutoCAD SHX Text
%%U6:12 W/ DBL ROWLOC
AutoCAD SHX Text
%%UEAVE DETAIL
AutoCAD SHX Text
SCALE 3/8"=1'
AutoCAD SHX Text
6-1/2" OFF FRAMING
AutoCAD SHX Text
1X4 FRIEZE BOARD
AutoCAD SHX Text
2X CEILING JOISTS
AutoCAD SHX Text
2X4 SOFFIT FRAMING
AutoCAD SHX Text
1/2" MASONITE
AutoCAD SHX Text
SOFFIT W/ METAL VENT
AutoCAD SHX Text
2X6 RAFTERS
AutoCAD SHX Text
ROOFING ON
AutoCAD SHX Text
ON 16" CENTERS
AutoCAD SHX Text
7/16" OSB
AutoCAD SHX Text
2X4 CONT.
AutoCAD SHX Text
BLOCKING
AutoCAD SHX Text
PLATELINE
AutoCAD SHX Text
%%U12:12 W/ DBL ROWLOC
AutoCAD SHX Text
%%UEAVE DETAIL
AutoCAD SHX Text
SCALE 3/8"=1'
AutoCAD SHX Text
6-1/2" OFF FRAMING
AutoCAD SHX Text
1X4 FRIEZE BOARD
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WINDOW SCHEDULE
AutoCAD SHX Text
1. VERIFY WITH WINDOW MANUFACTURER FOR TRUE ROUGH OPENING SIZES.
AutoCAD SHX Text
2 - 3'-0"
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ENTRY DOOR - PER SELECTION
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
2. DOORS AND WINDOWS BY BUILDER/OWNER.
AutoCAD SHX Text
3. TEMPERED GLASS. RE: FLOOR PLANS.
AutoCAD SHX Text
3W - 2'-6"
AutoCAD SHX Text
STUDY, DINING - 6 WINDOW UNIT, DL
AutoCAD SHX Text
2 - 2'-8"
AutoCAD SHX Text
GREAT ROOM - 1L
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
TO GARAGE - SC
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
3W - 2'-6"
AutoCAD SHX Text
STUDY, DINING - 6 WINDOW UNIT, DL
AutoCAD SHX Text
KITCHEN - 1L
AutoCAD SHX Text
GREAT ROOM - 1L
AutoCAD SHX Text
2W - 2'-0"
AutoCAD SHX Text
PLANNING - MULLED UNIT, 1L
AutoCAD SHX Text
BDRM #2, #3 - DL
AutoCAD SHX Text
CASEMENT
AutoCAD SHX Text
2W - 2'-6"
AutoCAD SHX Text
BATH #2 - MULLED UNIT, DL
AutoCAD SHX Text
BDRM #4 - 1L
AutoCAD SHX Text
CASEMENT
AutoCAD SHX Text
2W - 3'-0"
AutoCAD SHX Text
GAMEROOM - MULLED UNIT, 1L
AutoCAD SHX Text
CASEMENT
AutoCAD SHX Text
3W - 3'-0"
AutoCAD SHX Text
MSTR SUITE - MULLED UNIT, CSMT/FXD/CSMT 1L
AutoCAD SHX Text
CASEMENT/FIXED
AutoCAD SHX Text
2W - 2'-0"
AutoCAD SHX Text
MSTR BATH - MULLED UNIT, 1L
AutoCAD SHX Text
FRONT DORMERS - DL
AutoCAD SHX Text
2X CEILING JOISTS
AutoCAD SHX Text
2X4 SOFFIT FRAMING
AutoCAD SHX Text
1/2" MASONITE
AutoCAD SHX Text
SOFFIT W/ METAL VENT
AutoCAD SHX Text
2X6 RAFTERS
AutoCAD SHX Text
ROOFING ON
AutoCAD SHX Text
ON 16" CENTERS
AutoCAD SHX Text
7/16" OSB
AutoCAD SHX Text
6-1/2" OFF FRAMING
AutoCAD SHX Text
2X4 CONT.
AutoCAD SHX Text
BLOCKING
AutoCAD SHX Text
PLATELINE
AutoCAD SHX Text
1X4 FRIEZE BOARD
AutoCAD SHX Text
%%U16:12 W/ 10:12 SWEPT EAVE
AutoCAD SHX Text
%%UEAVE DETAIL
AutoCAD SHX Text
SCALE 3/8"=1'
AutoCAD SHX Text
%%UW/ DBL ROWLOC
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
TOTAL AREA UNDER ROOF:
AREA TABULATION:
REAR COVERED PATIO:
TOTAL A/C:GARAGE:
FIRST FLOOR A/C:
4132 sq.ft.524 sq.ft.
294 sq.ft.
4999 sq.ft.
1954 sq.ft.SECOND FLOOR A/C: 2178 sq.ft.
FRONT PORCH: 49 sq.ft.
A A
B
B
C
C
D
1
2 2
3
AutoCAD SHX Text
%%USTUDY
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
FIRST FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%UDINING
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%UENTRY
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%UGREAT
AutoCAD SHX Text
%%UKITCHEN
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%UPATIO
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%UCOV'D
AutoCAD SHX Text
%%UGARAGE
AutoCAD SHX Text
10' CLG.
AutoCAD SHX Text
%%U2-CAR
AutoCAD SHX Text
3W-2660 FXD DL
AutoCAD SHX Text
HDR @ 9'
AutoCAD SHX Text
3W-2620 TRSM DL
AutoCAD SHX Text
3W-2660 FXD DL
AutoCAD SHX Text
HDR @ 9'
AutoCAD SHX Text
3W-2620 TRSM DL
AutoCAD SHX Text
10' CLG./CONC
AutoCAD SHX Text
%%UPORCH
AutoCAD SHX Text
12" WOOD POST
AutoCAD SHX Text
6880 SRO
AutoCAD SHX Text
HDR @ 8'
AutoCAD SHX Text
2W-2050 FXD DL
AutoCAD SHX Text
5780 SRO
AutoCAD SHX Text
5780 SRO
AutoCAD SHX Text
36"H. ISLAND
AutoCAD SHX Text
VENTHOOD ABV
AutoCAD SHX Text
36" CT W/
AutoCAD SHX Text
HDR @ 8'
AutoCAD SHX Text
2040 FXD 1L
AutoCAD SHX Text
HDR @ 8'
AutoCAD SHX Text
2040 FXD 1L
AutoCAD SHX Text
BUILT-INS
AutoCAD SHX Text
BUILT-INS
AutoCAD SHX Text
INSERT FP
AutoCAD SHX Text
FLUSH HEARTH
AutoCAD SHX Text
HDR @ 8'
AutoCAD SHX Text
4018 FXD 1L
AutoCAD SHX Text
HDR @ 8'
AutoCAD SHX Text
4018 FXD 1L
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
6" TRIM BEAM
AutoCAD SHX Text
2-2880 1L
AutoCAD SHX Text
2-2880 1L
AutoCAD SHX Text
INSERT FP
AutoCAD SHX Text
17080 OPENING
AutoCAD SHX Text
TIRE STOP
AutoCAD SHX Text
18080 OVERHEAD GARAGE DOOR
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
E E E E
F
G
G
H
J
K
AutoCAD SHX Text
SECOND FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UBDRM #2
AutoCAD SHX Text
%%UBDRM #3
AutoCAD SHX Text
%%UBDRM #4
AutoCAD SHX Text
%%UMASTER SUITE
AutoCAD SHX Text
VAULTED CLG.
AutoCAD SHX Text
%%UGAMEROOM
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2850 CSMT DL
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2850 CSMT DL
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2850 CSMT DL
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2850 CSMT DL
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2W-2636 FXD DL
AutoCAD SHX Text
%%UBATH #2
AutoCAD SHX Text
9' CLG./TILE
AutoCAD SHX Text
%%UMASTER
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
3050 CSMT 1L
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
3050 CSMT 1L
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2W-3050 CSMT 1L
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
2W-2040 FXD 1L
AutoCAD SHX Text
HDR @ 7'
AutoCAD SHX Text
3W-3050 CSMT/FXD/CSMT 1L
AutoCAD SHX Text
%%UMASTER
AutoCAD SHX Text
%%UBATH #3
AutoCAD SHX Text
%%ULANDING
AutoCAD SHX Text
41" GLASS HW
AutoCAD SHX Text
TRIM RIDGE BEAM
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
L L
AutoCAD SHX Text
RIGHT ELEVATION
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 10'-1'
AutoCAD SHX Text
T.O.>. 9'-1'
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 11'-1'
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
2ND FIN. FL.
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FRONT ELEVATION
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 10'-1'
AutoCAD SHX Text
T.O.>. 9'-1'
AutoCAD SHX Text
2ND FIN. FL.
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
AutoCAD SHX Text
LEFT ELEVATION
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
T.O.>. 9'-1'
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 10'-1'
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
2ND FIN. FL.
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 11'-1'
AutoCAD SHX Text
REAR ELEVATION
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 10'-1'
AutoCAD SHX Text
FIN. FL. 0'-0"
AutoCAD SHX Text
T.O.>. 11'-1'
AutoCAD SHX Text
T.O.>. 9'-1'
AutoCAD SHX Text
2ND FIN. FL.
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
10:12 PITCH
AutoCAD SHX Text
FLARED EAVE
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS
AutoCAD SHX Text
GROUND FLOOR ELECTRICAL PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
DOUBLE EXT. FLOODLIGHT
AutoCAD SHX Text
PHONE JACK
AutoCAD SHX Text
T.V. ANT. JACK
AutoCAD SHX Text
SINGLE EXT. FLOODLIGHT
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
WALL MOUNT LIGHT
AutoCAD SHX Text
3 WAY SWITCH
AutoCAD SHX Text
110 V. HALF HOT RECEPT.
AutoCAD SHX Text
110V. W/ GFI. INTERUPTION
AutoCAD SHX Text
110V. WATERPROOF GFI.
AutoCAD SHX Text
220V. RECEPTACLE
AutoCAD SHX Text
110 V. RECEPTACLE
AutoCAD SHX Text
FLOUR. LIGHT STRIP.
AutoCAD SHX Text
CEILING FAN
AutoCAD SHX Text
SPOT LIGHT
AutoCAD SHX Text
CANLIGHT
AutoCAD SHX Text
SECOND FLOOR ELECTRICAL PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
11/21/2017
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
PLAN NUMBER
AutoCAD SHX Text
by the builder or the person in authority of this project. Any discrepancy, error,
AutoCAD SHX Text
Copyright, S. Watson Design, Inc. - 2017
AutoCAD SHX Text
These plans are intended to provide the basic construction information necessary
AutoCAD SHX Text
to substantially complete this structure. These plans must be verified and checked
AutoCAD SHX Text
and Local codes, ordinances, and restrictions take precedence over any part of
AutoCAD SHX Text
designer before any construction is commenced or purchases made. It is recommended
AutoCAD SHX Text
and / or omission, if found, is to be brought to the immediate attention of the
AutoCAD SHX Text
that the owner or builder obtain complete Engineering services; Foundation, Hvac, and
AutoCAD SHX Text
Structural, before beginning construction of any kind. Note: All Federal, State,
AutoCAD SHX Text
by any means without the expressed written consent of Watson Design. All rights reserved
AutoCAD SHX Text
Watson Design and are not to be used for construction, reused, traced, or reproduced
AutoCAD SHX Text
these plans which may conflict with same, and must be strictly obeyed and followed
AutoCAD SHX Text
before and during construction. These plans, and their use are the property of
AutoCAD SHX Text
3537 W. 7TH
AutoCAD SHX Text
FORT WORTH, TEXAS
AutoCAD SHX Text
0.817.882.8882
AutoCAD SHX Text
SCALE 24X36 1/4"=1'
AutoCAD SHX Text
OLERIO HOMES
AutoCAD SHX Text
WATSON DESIGN GROUP
AutoCAD SHX Text
WATSONDESIGNGROUP.COM
AutoCAD SHX Text
4170 SARANAC DRIVE LOT 15, BLOCK 11/6147 GLENRIDGE ESTATES CITY OF DALLAS DALLAS COUNTY, TEXAS