Tintometer GmbH Products Water Analysis. Overview Lovibond® Products Titrimetric methods MINIKIT ...

Post on 17-Dec-2015

225 views 0 download

Tags:

Transcript of Tintometer GmbH Products Water Analysis. Overview Lovibond® Products Titrimetric methods MINIKIT ...

Tintometer GmbHProducts Water Analysis

2

Overview Lovibond® Products Titrimetric methods

• MINIKIT

Colorimetric methods• Comparators (CHECKIT and 2000+)• Photometers (MD 100 (Boiler and Cooling Water), MD 200, MD 600, MultiDirect and

SpectroDirect)

Biochemical Oxygen Demand (BOD)• BD 600 • Thermostatically controlled incubators

Chemical Oxygen Demand (COD)• Thermoreactor RD 125

Electrochemistry• SensoDirect Serie (Oxi200, SensoDirect 150)• SD-Serie (SD 320, SD 300, SD 50, SD 60, SD 70, SD 80, SD 90)

Turbidity• TB 300 IR, TB 210 IR and TB 250 WL

Floc-Testers

3

Titrimetric methodsMINIKIT

Easy operation and exact reagent dosing

High accuracy Foil-wrapped Lovibond®

tablet reagents with a minimum guaranteed shelf life of 5 years

Unrestricted shipment

Safe storage

© Tintometer GmbH4

Arsenic Test Kit– Easy to handle– Highly sensitive according to WHO

requirements (0.005 mg/l Arsenic detectable)– Resolution: 0 - 0.005 - 0.01 - 0.025 - 0.05 - 0.1

- 0.25 - 0.5 mg As3+/5+

– Closed reaction vessel to not harm the user by arsine gas escape

– Removal of the interfering sulfide ions is integrated in the test procedure.

– Complete in a carrying case, ready to use

Applications Drinking Water Use in the field or laboratory

5

Colorimetric methodsCHECKIT Comparator Handy and reliable

colorimetric measurement system

Different Checkit®Discs for different parameters and measurement ranges available

Continuous colour scales to achieve an exact colour match between the colour standard and the sample

Using long time stable Lovibond® tablet reagents

6

Colorimetric methodsComparator 2000+

Visual test systems for a range of water analysis applications

Colorimetric measurement system

400 different colour discs for different parameters or measurement ranges available

Long time colour stable Lovibond® glass standards

Daylight unit with rechargeable battery

Cell holder up to 40 mm path length

7

Lovibond® Photometer

MD 200

MD100 MD 600

MultiDirect

SpectroDirectM

D 6

00

8

Colorimetric methodsPhotometer MD 100 and MD 200

High quality interference filters Accurate, reproducible results Very quickly Compact dimensions Storage function Data transfer One Time Zero (OTZ) Single and Multi Parameter Reference Standard Kits for

Chlorine and pH Verification Standard Kit

9

Colorimetric methodsMD 100 Boiler and Cooling Water

Boiler Water Aluminium, Chloride, Copper,

DEHA, Hydrazine, Iron, Oxygen, Phosphate, Polyacrylate, Silica

Cooling Water Aluminium, Bromine, Chlorine LR

and HR, Chlorine dioxide, Copper, Iron, Molybdenum, Ozone, Sulfate, Triazole, Zinc

10

Colorimetric methodsPhotometer MD 600Combines the mobility of a portable photometer with characteristics of a modern laboratory photometer

Wide range of preprogrammed methods (> 120 methods)

35 user defined methods Updates of new methods via Net Compact dimensions Memory for 1000 data sets Data transfer Verification Standard Kit

11

Colorimetric methodsPhotometer MultiDirect

Dual Beam Technology Interference filters for highest

accuracy Wide range of pre-programmed

methods Update of new methods via Net Interface Mobile Graphic Display Rechargeable batteries

(recharged within device) Memory for 1000 data sets Verification Standard Kit

12

Colorimetric methodsPhotometer SpectroDirect

Single beam spectral photometer Wavelength range: 330 to 900 nm Self-test Multifunctional sample chamber

(16 and 24 mm round vials; 10 - 50 mm rectangular cells without adapter) User prompt in the display

(different languages available) Spectral data, wavelength scan

over user-defined interval

13

Biochemical Oxygen Demand (BOD) – BD 600

User friendly Large brilliant graphic display Graphical representation of measured

values Bluetooth, USB & SD Card Interface Manometric measurement system Selectable measuring period 1 - 28

days (BOD5, BOD7, OECD...) Result memory for up to 28 days Measuring ranges from 0 - 40 mg/l to

0 - 4000 mg/l Ecologically friendly (mercury-free) Automatic Start function Test set for BD 600 available

14

Biochemical Oxygen Demand (BOD)

Thermostatically controlled incubators (TC series)

Temperature from 2 °C to 40 °C Regulate in steps of 0.1 °C Temperature tolerance: ± 1 °C,

specified for a stirred 500 ml water sample

(for BOD, T = 20 °C : ± 0.5 °C) Volume 135 to 445 liters Optional glass door Various applications e.g. BOD,

microbiological testing, storage of water samples

15

Chemical Oxygen Demand (COD)

Waste water parameter Complete COD-Measurement

Set-up (Tubes, Thermoreactor and Photometer)

Accurate and easily performed determination of Chemical Oxygen Demand

COD vario vial tests are available for 3 measuring ranges:

0 - 150 mg/l O2,

0 - 1500 mg/l O2, 0 - 15000 mg/l O2

ST-COD sealed tubes ready for use

16

Chemical Oxygen Demand (COD)

Thermoreactor RD 125

For the Tube test digestion of: COD TOC Total Chromium Total Nitrogen Total Phosphate

24 holes Selectable temperature: 100, 120 and

150 °C Temperature stability: ± 1 °C Selectable Time: 30, 60, 120 min and

conti mode

17

Lovibond® Reagents for Water Testing

Tablets

Liquids

Tube tests

VARIO Powder

© Tintometer GmbH18

Lovibond® Tablet Reagents Long shelf-life (up to 10 years) Accurate dosing and accurate

test results Minimized health risks Low transportation costs

© Tintometer GmbH19

Lovibond® Liquid Reagents Limited shelf life Easy dosing dropwise Easy dissolving Limitation of bottle size DPD liquid in three bottles

© Tintometer GmbH20

Lovibond® Powder Reagents Long shelf life (5 years) Easy dosing Improved packaging Low transportation costs

© Tintometer GmbH21

Powder Dispenser• DPD Method (Vario)• For Free and Total Chlorine testing

according ISO 7393 - 2:2000• Range

– 0 - 2 mg/l Free Chlorine– 0.1 - 8 mg/l Total Chlorine

• Sample size 10 ml• 250 tests / reagent vials• Shelf life: 5 years (reflects unopened

ampulle, use material within 6 months of removing the seal)

© Tintometer GmbH22

Lovibond Tube Test Prefilled reagent tubes According international

standards Hazardous chemicals Combination powder – test

tubes 16 mm tubes Suitable for many instruments COD, Nitrogens, Phosphorous,

etc.

23

Electrochemistry

SD 300 pH, SD 320 Con High resolution (0.001 pH/0.1 mV)

Rugged, water resistant Designed for field use Automatic temperature

compensation Automatic buffer detection

for calibration PC interface for data

transfer (USB / serial or analog)

Data logger Backlit LCD display

24

ElectrochemistrySensoDirect Oxi200

Easily handled Water and shock-proof Hold-function Automatic temperature

compensation Oxygen partial

pressure/oxygen concentration/ oxygen saturation, temperature measurement; no polarization period needed

easy calibration against oxygen in air

25

ElectrochemistrySensoDirect 110

Light weight

Protective casing

Large digital display

Large digital display

“Low battery” indicator

Two point Calibration

26

Electrochemistry

SD Series

Portable Hand-Held Meter

scroll-Through

Functionality

Compact & Robust

storage Function

Backlit Display

Waterproof

27

Lovibond® Turbidity Meter

TB 210 IR TB 300 IR

TB 250 WL

28

TurbidityPrinciple of Turbidity Measurement

29

Turbidity

TB 300 IR, TB 210 IR and TB 250 WL TB 300 IR, TB 210 and

TB 250 WL: laboratory and field use

Infrared light source for colourless and coloured samples

TB 250 WL with white light source

Range: 0.01 - 1100 NTU Complete unit including

accessories and calibration standards

30

Floc Testers

Continuously variable stirring speed

Digital display Timer feature Height adjustment of

the stirring plates during operation

Type ET 730 portable, for use in the field or laboratory applications