Post on 09-Mar-2018
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
TIMER 5 - 90 sec. with PIC16F84A microcontroller
TIMER da 5 a 90 secondi
MANUALE TECNICO e ISTRUZIONI
1 2 3 4
A
B
C
D
4321
D
C
B
A
Author:
Project:
Size: DWG no. Rev.: Scale: Sheet:
Year:
Note:
2017
A 1 1 1:1 1 of 1
http://www.narcisivalter.it/progetti/timer-30-60-90.html
S2
START
S1
PROG.
S3
RESET
C30.1
+5
C427p
XT1
4 MHzC527p
©2017 All rights reserved
Valter Narcisi - San Benedetto del Tronto (AP)
Timer 90 seconds (All sections)
RB4 10
RB5 11
RB6 12
RB7 13
GND
5+V
14
MCLR4
RB2 8
RA1 18RA2 1
RB3 9
RB0 6
OSC215
RA43
RB1 7
RA0 17
RA32
OSC116
U1PIC 16F84A
R6 4k7
R5 4k7
R7 270R8 270R9 270R10 270R11 270R12 270R13 270
R310k
R210k
R110k
Q3BC337
R4
2k2
RL1RELAY 5V
+5
D2
FDH9
99
DL1LED On
R14220
123456
M2
Load
PAUSE
a b c d e f g
7 6 4 2 1 9 10
AC3 5
AC8
dp
DS1
a b c d e f g
7 6 4 2 1 9 10
AC3 5
AC8
dp
DS2
Q2BC327
Q1BC327
12345678910
12345678910
M3
+5
Display HDN1131‐O Low currentDS1‐DS2
+
M16 Vcc
+C110u ‐ 16V
+5Power Supply
C20.1
D1
1N4001DL2LEDR15
330
(Step Down)
R16
470
D3
FDH9
99
C6.1
1 2 3 4
A
B
C
D
4321
D
C
B
A
Author:
Project:
Size: DWG no. Rev.: Scale: Sheet:
Year:
Note:
2017
— 1 / 2 1 1:1 1 of 1
http://www.narcisivalter.it/progetti/timer-30-60-90.html
C427p
XT
4 MHzC527p
©2017 All rights reserved
Valter Narcisi - San Benedetto del Tronto (AP)
Timer 90 seconds (MAIN section)
RB4 10
RB5 11
RB6 12
RB7 13
GND
5+V
14
MCLR4
RB2 8
RA1 18RA2 1
RB3 9
RB0 6
OSC215
RA43
RB1 7
RA0 17
RA32
OSC116
U1PIC 16F84A
R6 4k7
R5 4k7
R7 270R8 270R9 270R10 270R11 270R12 270R13 270
Q3BC337
R4
2k2
RL1RELAY 5V
+5
D2
FDH9
99
DL1LED On
R14220
123456
M2
Load
12345678910
M3
To Display section
+5
S2
START
S1
PROG.
S3
RESET
C30.1
+5
R310k
R210k
R110k
PAUSE
R16
470
D3
FDH9
99
C6.1
+
M16 Vcc
+C110u ‐ 16V
+5Power Supply
C20.1
D1
1N4001DL2LEDR15
330
(Step Down)
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
1 2 3 4
A
B
C
D
4321
D
C
B
A
Author:
Project:
Size: DWG no. Rev.: Scale: Sheet:
Year:
Note:
2017
— 2 / 2 1 1:1 1 of 1
http://www.narcisivalter.it/progetti/timer-30-60-90.html
a b c d e f g
7 6 4 2 1 9 10
AC3 5
AC8
dp
DS1
a b c d e f g
7 6 4 2 1 9 10
AC3 5
AC8
dp
DS2
Q2BC327
Q1BC327
©2017 All rights reserved
Valter Narcisi - San Benedetto del Tronto (AP)
Timer 90 seconds (Display section)
12345678910
M3
To Main section
Display HDN1131‐O Low currentDS1‐DS2
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
COMPONENTs LIST Designator Value -------------- ------------------- C1 10uF - 16V C2 - C3 0.1 uF ceramic C4 - C5 27pF (ceramic NPO) C6 0.1 uF ceramic R1 - R2 - R3 10k R4 2k2 R5 - R6 4k7 R7 ... R13 270 ohm R14 220 ohm R15 330 ohm R16 470 ohm D1 1N4001 D2 - D3 FDH999 DL1 - DL2 LED (red) DS1 - DS2 HDN-1131o (Low power, SuperRed, Orange) Q1 - Q2 - Q3 BC327 (PNP 800 mA) U1 PIC 16F84A microcontroller XT 4 MHz crystal RL1 Relay 5V – 2 way M1 2 way socket (5 mm.) M2 6 way socket (5 mm.) M3 10 way socket (2.54) S1 - S2 - S3 Strip 2 way (2.54)
©2017 by Valter Narcisi – San Benedetto del Tr. – http://www.narcisivalter.it/progetti/timer-30-60-90.html
COMANDI e USO All'accensione, il display visualizza l’ultimo valore programmato. PROG. Pulsante per la programmazione dei secondi. Ad ogni pressione del pulsante, sul display appare un valore multiplo di 5 (da 5 a 90). START Pulsante per l’avvio del Timer (e del relè). Premendo nuovamente il pulsante, il Timer resterà in PAUSA (con il carico disattivato) e la successiva nuova pressione del pulsante fa ripartire il conteggio. L’accensione del LED rosso indica sempre l’attivazione del Relè e quindi l’attivazione del carico ai suoi contatti. RESET Pulsante per il RESET generale: premendo questo pulsante il Timer è resettato, il relè disattivato e sul display appare l’ultimo valore programmato. N.B. - Evitare di spegnere il Timer durante il conteggio: prima di spegnere il Timer, quindi, assicurarsi che lo stesso non sia in fase di conteggio con il relè attivato.