The Synergy of Selective Laser Microdissectionand Sensitive AnalysisLeica Microsystems – QIAGEN Application Support
0
4
Sectioning Staining Microdissection Isolation Analysis
Leica_Qiagen_Brochure.qxd:Leica_Qiagen_Brochure.qxd 24.01.2012 14:29 Uhr Seite 5
Sectioning Staining
Reliable instruments for infiltration,embedding and sectioningPrepare tissue sections by using a variety of sec-tioning techniques. Choose the appropriate Leicainstrument for your application: cut frozen tissuewith a cryostat, fixed and paraffin-embedded tis-sues using the Leica RM22 family of rotary microto-mes, or native, unfrozen tissue under physiologicalconditions with a Leica VT1200/1200 S vibratingmicrotome.
Efficient staining of tissue sectionsStain your fixed sections and visualize cell structures athigh resolutions. Staining workstations from Leica allowseveral staining protocols to run simultaneously, and canbe programmed to satisfy customized requirements. Built-in filters reduce exposure to hazardous fumes, and thestaining process can be monitored through a transparentlid.
Microdissection
Fast, selective and easy to use!Collect selective dissected single cell(s) and tissueregions of any shape or size. The Leica LMD6500/7000are fully automated laser microdissection systems enab-ling the user to collect easily ultra-pure samples with aprecise, contamination-free method-simply by gravity.The unique systems allow you to harvest directly one ormore cell types from a slide or a petri dish. Excise selec-tive cells or metaphase chromosomes from a wide rangeof samples, including paraffin-embedded sections, fro-zen sections, blood smears, and stained or immuno-labe-led specimens.
Leica RM2265 –Rotary Microtome, highperformance motorizedand manual sectioning.
Leica CM1950 – Versatileresearch cryostat providesexcellent frozen sectioningquality and reproducibili-ty, especially for largespecimens such as braintissue.
Leica LMD7000 – Experience a new levelof speed.
Leica ST5020 –Automated stainingfor highly efficientworkflow
Frame foil slides andglass foil slides
Leica VT1200/1200 S –Vibrating blade microtome toprepare high-quality fixed andunfixed sections, ideal for neu-roscience research.
Paraffin section unstained (intestines) HE stained tissue section (intestines) After microdissection/dissectate in PCR tube
For
mor
e in
form
ati
on,
ple
ase
vis
it w
ww
.lei
ca-m
icro
syst
ems.
com
Leica ST4020 –Quick and easyautomated stainingof frozen sections
Leica_Qiagen_Brochure.qxd:Leica_Qiagen_Brochure.qxd 24.01.2012 14:29 Uhr Seite 2
Isolation of Analytes
Efficient purification of DNA, RNA, miRNA,and proteinsPurify analytes from laser-microdissected tissue sectionsusing QIAGEN® Sample Technologies that are special-ly designed to process very small amounts of startingmaterial. Efficient purification of DNA and RNA fromlaser-microdissected fresh-frozen tissues is achievedusing the QIAamp® DNA Micro Kit (cat. no. 56304)and the RNeasy® Plus Micro Kit (cat. no. 74034), respec-tively. For laser-microdissected formalin-fixed, paraffin-embedded (FFPE) tissues, the QIAamp DNA FFPE TissueKit (cat. no. 56404), RNeasy FFPE Kit (cat. no. 73504),and miRNeasy FFPE Kit (cat. no. 217504) maximizerecovery of usable DNA, RNA, and miRNA, respective-ly. Simultaneous purification of genomic DNA and totalRNA (including small RNA) from FFPE tissue sections orlaser-microdissected cryosections is made possible withthe AllPrep® DNA/RNA FFPE Kit (cat. no. 80234) or theAllPrep DNA/RNA Micro Kit (cat. no. 80284), respecti-vely. Full-length proteins can also be extracted fromwhole FFPE tissue sections using the Qproteome® FFPETissue Kit (cat. no. 37623).
Molecular Analysis
Highly specific and sensitive amplification fordetailed characterization of nucleic acidsAmplify nucleic acids using QIAGEN Assay Technologies,which are ideally suited for very small amounts of startingmaterial. Highly specific hot-start PCR solutions such asHotStarTaq® Plus DNA Polymerase (cat. no. 203601) andthe QIAGEN Multiplex PCR Plus Kit (cat. no. 206152) faci-litate fast and successful molecular analysis of DNA. TheREPLI-g® series enables whole genome amplification(www.qiagen.com/PG/REPLI-g), and the QIAGENOneStep RT-PCR Kit (cat. no. 210210) allows one-step RT-PCR of any RNA template without optimization, and withmaximum sensitivity, making them highly suited for appli-cations including viral load determination. For gene expres-sion analysis, the QuantiFast® Probe RT-PCR Plus Kit (cat.no. 204482) is highly suited for sensitive one-step quantifi-cation of RNA targets, including from FFPE samples con-taining highly degraded RNA. Combined with genomewi-de, predesigned QuantiFast Probe Assays, they deliverguaranteed results in probe-based real-time PCR detection.For two-step qRT-PCR, the QuantiTect® ReverseTranscription Kit (cat. no. 205311) is optimized for cDNAsynthesis with integrated genomic DNA removal from verysmall amounts of RNA (10 pg to 1 μg). Quantitative PCRand RT-PCR using QuantiFast Multiplex PCR and RT-PCRKits (cat. nos. 204543 and 204643) allow analysis of mul-tiple targets (2–4) in 1 reaction vessel. For microRNA rese-arch, the miScript PCR Starter Kit (cat. no. 218193) enablesquantification of mature and precursor miRNA. QIAGEN´sPCR kits, together with automated platforms for PCR setupand DNA fragment analysis, ensure reproducibility and con-venience, along with fast and consistent delivery of success-ful results.
Achieve sensitive and specific resultsin conventional and real-time amplifi-cation.
Pure nucleic acid
Sensitive analysisFrozen Formalin
M tissue fixed tissue M
500 bp
QIAGEN kits provide high-qualityRNA and DNA from laser microdis-sected specimens
For
mor
e in
form
ati
on,
ple
ase
vis
it w
ww
.qia
gen
.com
Convenient Kits
Leica_Qiagen_Brochure.qxd:Leica_Qiagen_Brochure.qxd 24.01.2012 14:29 Uhr Seite 3
O n e S o l u t i o n – Tw o I n n o v a t i v e P a r t n e r sThe Leica–QIAGEN AgreementLeica is a leading supplier of high precision optical microscopes and related instruments, and provides efficient tools for all the steps required for laser microdissection of tissue samples.QIAGEN has a worldwide reputation for its technologies for nucleic acid purification, and provides optimized reagents and protocols for purification and analysis of nucleic acids fromdissected samples. The agreement between QIAGEN and Leica combines the expertise of two leading companies to bring you complete solutions for analyzing nucleic acids from laser-microdissected specimens.
For detailed information contact your local partner!
Leica Microsystems CMS GmbHErnst-Leitz-Straße 17 – 37D-35578 Wetzlar, GermanyTel. +49 (0) 64 41-29 0Fax +49 (0) 64 41-29 25 99www.leica-microsystems.com
QIAGEN GmbHQIAGEN Strasse 140724 Hilden,GermanyTel. +49 (0) 2103-29-12400Fax +49 (0) 2103-29-22000www.qiagen.com
Leica Microsystems – an international company with a strong network of customer servicesAustralia: North Ryde Tel. +61 2 8870 3500 Fax +61 2 9878 1055
Austria: Vienna Tel. +43 1 486 80 50 0 Fax +43 1 486 80 50 30
Belgium: Groot Bijgaarden Tel. +32 2 790 98 50 Fax +32 2 790 98 68
Canada: Concord/Ontario Tel. +1 800 248 0123 Fax +1 847 236 3009
Denmark: Ballerup Tel. +45 4454 0101 Fax +45 4454 0111
France: Nanterre Cedex Tel. +33 811 000 664 Fax +33 1 56 05 23 23
Germany: Wetzlar Tel. +49 64 41 29 40 00 Fax +49 64 41 29 41 55
Italy: Milan Tel. +39 02 574 861 Fax +39 02 574 03392
Japan: Tokyo Tel. +81 3 5421 2800 Fax +81 3 5421 2896
Korea: Seoul Tel. +82 2 514 65 43 Fax +82 2 514 65 48
Netherlands: Rijswijk Tel. +31 70 4132 100 Fax +31 70 4132 109
People’s Rep. of China: Hong Kong Tel. +852 2564 6699 Fax +852 2564 4163
Shanghai Tel. +86 21 6387 6606 Fax +86 21 6387 6698
Portugal: Lisbon Tel. +351 21 388 9112 Fax +351 21 385 4668
Singapore Tel. +65 6779 7823 Fax +65 6773 0628
Spain: Barcelona Tel. +34 93 494 95 30 Fax +34 93 494 95 32
Sweden: Kista Tel. +46 8 625 45 45 Fax +46 8 625 45 10
Switzerland: Heerbrugg Tel. +41 71 726 34 34 Fax +41 71 726 34 44
United Kingdom: Milton Keynes Tel. +44 800 298 2344 Fax +44 1908 246312
USA: Buffalo Grove/lllinois Tel. +1 800 248 0123 Fax +1 847 236 3009
Order no. of the edition in: English 914 641 • Part-No. 501-363LEICA and the Leica Logo are registered trademarks of Leica IR GmbH. I/12/ELW/SD.H.
Australia � Orders 03-9840-9800 � Fax 03-9840-9888 � Technical 1-800-243-066Austria � Orders 0800-28-10-10 � Fax 0800-28-10-19 � Technical 0800-28-10-11Belgium � Orders 0800-79612 � Fax 0800-79611 � Technical 0800-79556Brazil � Orders 0800-557779 � Fax 55-11-5079-4001 � Technical 0800-557779Canada � Orders 800-572-9613 � Fax 800-713-5951 � Technical 800-DNA-PREP (800-362-7737)China � Orders 86-21-3865-3865 � Fax 86-21-3865-3965 � Technical 800-988-0325 or 400-880-0325Denmark � Orders 80-885945 � Fax 80-885944 � Technical 80-885942Finland � Orders 0800-914416 � Fax 0800-914415 � Technical 0800-914413France � Orders 01-60-920-920 or 0800-912965 � Fax 01-60-920-925 � Technical 01-60-920-930 or 0800-912961Germany � Orders 02103-29-12000 � Fax 02103-29-22000 � Technical 02103-29-12400Hong Kong � Orders 800 933 965 � Fax 800 930 439 � Technical 800 930 425India � Orders 1-800-102-4114 � Fax 1-800-103-4114 � Technical 1-800-102-4115Ireland � Orders 1800 555 049 � Fax 1800 555 048 � Technical 1800 555 061Italy � Orders 02-33430411 � Fax 02-33430426 � Technical 800 787980Japan � Orders 03-6890-7300 � Fax 03-5547-0818 � Technical 03-6890-7300Korea (South) � Orders 080-000-7146 � Fax 02-2626-5703 � Technical 080-000-7145Luxembourg � Orders 8002-2076 � Fax 8002-2073 � Technical 8002-2067The Netherlands � Orders 0800-0229592 � Fax 0800-0229593 � Technical 0800-0229602Norway � Orders 800-18859 � Fax 800-18817 � Technical 800-18712Singapore � Orders 1800-742-4362 � Fax 65-6854-8184 � Technical 1800-742-4368Spain � Orders 91-630-7050 � Fax 91-630-5145 � Technical 91-630-7050Sweden � Orders 020-790282 � Fax 020-790582 � Technical 020-798328Switzerland � Orders 055-254-22-11 or 0800-897470 � Fax 055-254-22-13 � Technical 055-254-22-12 or 0800-837160Taiwan � Orders 0080-665-1946 � Fax 8862-2369-1100 � Technical 0080-665-1947UK � Orders 01293-422-911 or 0808-2343665 � Fax 01293-422-922 � Technical 01293-422-999 or 0808-2343974USA � Orders 800-426-8157 � Fax 800-718-2056 � Technical 800-DNA-PREP (800-362-7737)
For up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN kit handbook oruser manual. QIAGEN kit handbooks and user manuals are available at www.qiagen.com or can be requestedfrom QIAGEN Technical Services or your local distributor.
Trademarks: QIAGEN®, QIAamp®, AllPrep®, HotStarTaq®, Qproteome®, QuantiFast®, QuantiTect®, REPLI-g®,RNeasy®(QIAGEN Group).
QIAGEN — a wide range of products and services for analyte isolation and analysis
Leica_Qiagen_Brochure.qxd:Leica_Qiagen_Brochure.qxd 24.01.2012 14:29 Uhr Seite 4