Technologies available at IGCARADOR Welding Pvt Ltd., Pune The present invention would reduce the...

Post on 05-Apr-2020

3 views 0 download

Transcript of Technologies available at IGCARADOR Welding Pvt Ltd., Pune The present invention would reduce the...

Department of Atomic Energy / Indira Gandhi Centre for Atomic Researchwww.dae.gov.in ; www.igcar.gov.in

Department of Atomic Energy / Indira Gandhi Centre for Atomic Researchwww.dae.gov.in ; www.igcar.gov.in

Technologies available at IGCAR

Technology Transfer Cell at IGCAR Indigenous development/products/know-how that can be protected/copyright/trademark, etc., Evaluation and submission of new technologies developed in IGCAR to DAE for approval for possible transfer to industryWorking out modalities for technology transfer in liaison with scientists and engineers of IGCAR and the user industries Preparing technology transfer documents and expediting the transfer of technology through Technology Transfer &

Collaboration Division, BARC

Activated Flux for TIG Welding ofStainless Steels transferred toADOR Welding Pvt Ltd., Pune

The present invention would reduce thedistortion of tungsten inert gas welds andproduce welds with mechanical propertiesthat are nondegradable through the use offlux.

Oxygen sensors for On-BoardOxygen Generating SystemThe present invention would do to monitorthe performance of the On-Board OxygenGenerating System (OBOGS) continuouslywith an oxygen sensor.

Potentiometric oxygen sensors usingZirconia electrolyte

An oxygen sensor using yttria stabilizedzirconia solid electrolyte has beendesigned and developed for thispurpose

The response time for a change inoxygen concentration is rapid to alertabout the failure of OBOGS

This technology is being used in light combatair craft (LCA), Tejas. This sensor is requiredfor monitoring oxygen levels in the cockpit ofLCA, when it flies high altitudes. (DEBEL -DRDO Laboratory, Banglore)

pH Meter

The present invention would give a stable temperaturecompensated, highly precise and accurate pH value of thesolution over wide range

Stand-alone pH monitoring instrument: Measurement ofpH / ORP of aqueous solutionsRange of measurement: pH measurement – 3 to 10 usingstandard combinational type glass electrodepH probe: Standard glass electrode (combinational type)Temperature compensation: Provision for temperaturecompensation providedTemperature Probe: PT1000 RTD with pulsating transducerDisplay: Alpha numeric 4 X 20 character LCD displayProbe Connections: Standard combinational type glasselectrode shall be connected through a BNC type connectorand RTD type pulsating temperature sensor shall beconnected through 5-pin DIN connector at the front panelProbe output: A train of rectangular pulses of 5V amplitudePower Supply: 5V DC eliminator/power supply unitSignal processor: Atmel 8051 family microcontroller baseddigital counter to convert the frequency of input signal topH and temperature. The pH probe voltage outputconverted to frequency to generate digital pulse trainoutputAccuracy: 0.01% (measured with standard buffer solutions)Resolution: 1mV/10HzResponse time: < 1 secCalibration: Three point calibration using standard pHbuffer solutions (pH4.0, pH7.0 and pH9.2)

Conductivity Meter

This conductivity meter measures the multi point calibratedconductivity of the solution over 3 decades range of interest as percustomer requirement. This is a Pulsating type conductivity and temperatureprobe of unique design

Range of measurement: Flow type Conductivity probe –

0.06 to 5μS/cm Bench type Conductivity probe – 1 to 2000μS/cm temperature measuring range - 25 to 45°C

Temperature normalization: Provision for temperature normalization (display of conductivity is normalized at 25°C when temperature probeis connected)

Display: LCD display (4 x 20 characters) for display of conductivity in μS/cm and solution temperature in °C

Probe output: A train of rectangular pulses of 5V amplitude

Cable: 5-core shielded signal cables with 5-pin Gilard connectivity

Power Supply: Mains power supply (230V AC, 50 Hz); requirement is only for 5V DC power supply

Signal processor: Pulse counting in channels 1, 2 and 3

CH-1: Frequency (kHz) to Conductivity (μS/cm)

CH-2: Frequency (kHz) to Temperature (°C)

CH-3: Frequency (kHz) to Conductivity (μS/cm)

Precision: relative standard deviation is ≤1.0 % for both range conductivity probes

Accuracy: < 2.0 % in the entire measurement range

Resolution: Capable of monitoring conductivity shift by ≤ 0.02 μS/cm in the range 0.06 to 2 μS/cm and 0.1 μS/cm in the range covering1 to 2000 μS/cm

Response time: < 1 second

Calibration: Multipoint calibration using standard KCl solutions and resistance comparison method

Signal transmission: High precision in measurement, direct digital signal from probe head, and transmission of signal to a long distance(~ 100 meter) without losing precision in measurement

Low range probe

with electronics

High range probe

with electronics

High range probe with electronics0

High Volume Air SamplerThe present an indigenous invention would be used for collection of air particulates/suspended particle matters in any filter paper medium.

Wireless Remote for safer operation: With the remote device the air sampler can be operated within 20m radius. The remote connects to the embedded controller in the air sampler through Bluetooth connectivity

Timer: The remote has an inbuilt start, stop and pause timer, with which the sampler can be operated for desired time

Flow: It has an inbuilt flow indicator which displays the current flow rate and with the help of embedded controller the data is also shown and logged in the remote unit

Accumulated Flow: It logs the flow for the set time and calculates the accumulated flow automatically using a logarithm which is coded in the remote

GPS / Location: The remote has a GPS which logs approximate coordinates when the sample is taken. This feature would be helpful when the sampling is done in outdoor environments

Flow Controller: It has a flow controller with a precise flow from 40 to 100 CFM [1100 to 2800 lpm] can be achieved precisely

Data Logging: It has a data logging feature which logs date, time, set timer, logging time, flow, location and accumulated flow for the set time

Potential Technologies available at IGCAR for Transferring