Post on 18-Mar-2020
www.froeling.com
TX 150-250
2 3
H2
H4
L3 L2
H1
L1
H5
H6
L
B1
Dimensions
Components
TX 150 200 250
H1 Height, boiler mm 1880 1880 1880
H2 Height,flow/returnconnection mm 1935 1935 1935
H4 Height,fluegaspipeconnectionexcl.fluegasreturn mm 770 960 960
H5 Height,fluegaspipeconnectionincl.fluegasreturn mm 1410 1445 1445
H6 Height,stokerincl.burnbackprotectionsystem mm 790 865 865
B1 Totalwidthincl.fittings mm 1970 2070 2070
L Totallength mm 2620 2980 2980
L1 Length,combustionchamber mm 1090 1400 1400
L2 Length,stokerunit mm 940 970 970
L3 Length,ashcontainer mm 590 610 610
A Flowconnection
B Returnfeedconnection
C Combustionchamber
D Heatexchanger
E Controller
F Ashremovalchamber
G Heatexchangerashremoval
H Stokerincl.burnbacksystem
I Induceddraughtfan
J WOSdrive
K Safetybattery
www.froeling.com
TechnicalspecificationsTechnical specifications
TX 150 200 250
Nominalheatoutput kW 150 199 250
Heatoutputrange kW 45-150 59-199 75-250
Nominalfuelheatingefficiencywithwoodchips kW 163 214 271
Nominalfuelheatingefficiencywithpellets kW 165 216 275
Efficiencyofwoodchipsatnominalload/partialload % 92.1/92.3 92.9/92.6 93.7/92.8
Efficiencyofpelletsatnominalload/partialload % 90.8/93.4 92.7/92.1 93.5/92.0
Quantityoffuelrequiredatnominalload kg/h 48 61 76
BoilerclassasperEN303-5 4 5 5
Powerconnection 400V/50Hz 400V/50Hz 400V/50Hz
Electricfuses 20A 35A 35A
Electricalpowerconsumption W 260-730 285-650 315-565
Minimumroomheight mm 2370 2370 2370
MinimumclearanceforinstallationWxH mm 1000x1950 1000x1950 1000x1950
Weight,combustionchamber kg 855 1120 1120
Weight,heatexchanger kg 1000 1280 1280
Totalweightincl.fittings kg 2730 3390 3390
Heatexchangerflow/returnfeedconnection DN65/PN6 DN65/PN6 DN65/PN6
Safetybatteryflow/returnfeedconnection 1/2"IT 1/2"IT 1/2"IT
Drainage 3/4" 3/4" 3/4"
Heatexchangerwatercapacity l 440 570 570
Max.permittedoperatingtemperature °C 90 90 90
Minimumreturntemperature °C 65 65 65
Max.permittedoperatingoverpressure bar 3 3 3
Flowrateat∆T=20K m³/h 6.45 8.6 10.8
Flowrateat∆T=10K m³/h 12.9 17.2 21.6
Waterpressuredropat∆T=20K mbar 12 18 25
Waterpressuredropat∆T=10K mbar 36 55 74
MinimumairsupplyopeningasperÖNORMH5170 cm² 330 430 540
Fluegastemperatureatnominalload/partialload °C 150/110 150/110 150/110
Draughtrequirementatinduceddraughtfanoutletatnominalload/partialload mbar 0.05/0.02 0.05/0.02 0.05/0.02
Max.permittedchimneydraught mbar 0.3 0.3 0.3
Fluepipediameter mm 200 250 250
FGRpipediameter mm 150 150 150
FluegasmassflowwithwoodchipW30,13%O2* m³/h(kg/h) 807(665) 1071(882) 1346(1108)
FluegasmassflowwithwoodchipW30,9%O2* m³/h(kg/h) 511(420) 648(557) 852(700)
Fluegasmassflowwithwoodpellets,13%O2* m³/h(kg/h) 673(559) 893(741) 1121(931)
Fluegasmassflowwithwoodpellets,9%O2* m³/h(kg/h) 426(355) 566(471) 711(591)
*...usehigheroxygencontentforchimneydesign!
TX 150-250
Recommended minimum distances in the boiler room
Fuels and discharge options for TX 150 - 250
TX 150 200 250
A Spacerequiredforinspectionareaofinfeed mm 400 400 400
B Distancefromheatexchangersidetowall mm 300 300 300
C Spacerequiredforremovalofashbox mm 400 400 400
D Spacerequiredforinspectionareaofcombustionchamber mm 400 400 400
Wood chips Pellets
SpringbladeagitatorBRW150 o*
SpringbladeagitatorFBR150 -
ArticulatedarmdischargeunitGLA150 o*
ArticulatedtorsionarmdischargeunitTGR150 -
Slidingfloor * -
Obliquescrew * -
Horizontalscrew * -
Feedscrew * *
o...separaterotaryagitatordriverequired*...IMPORTANT:Additionalcontrolcabinetrequired
TX 1
50
TX 2
00
/2
50
Wood chips - Note on standards
EU EN14961-4classA2;P45,M35
AT ÖNORMM7133
DE Woodchipsasper§3(1)pointoftheFirstFederalEmissionsProtectionOrdinance(BimSchV)-applicableversion
Pellets - Note on standards
Wood pellets D06 as per EN 14961-2 class A1 and/or certification programENplus/DINplus
P0830013-Wereservetherighttomaketechnicalchangeswithoutpriornotice.Errorsandomissionsexcepted.
Heizkessel- und Behälterbau GesmbHA-4710 Grieskirchen, Industriestr. 12AUT:Tel+43(0)7248606-0•Fax+43(0)7248606-600GER:Tel.+49(0)89927926-0•Fax+49(0)89927926-219Email: info@froeling.com• Internet:www.froeling.com