Self contained, high efficiency thru-the-wall heating & cooling unit Heating - 12000 - 63000 Btuh
Cooling - 12800 Btuh, 16500 Btuh, 19500 Btuh, 24400 Btuh
Technical Specifi cations
FEATURES • Up to 10.8 EER• Up to 24400 Btuh Cooling• Easily removable R-410A Air conditioning module• Micro-Channel Condenser and Evaporator Coils• High efficiency Copeland scroll compressor• Pre-wired and pre-charged • Up to 63000 Btuh Heating• Easily removable hydronic heating modules containing 3 row or 4 row hot water coil• 24VAC color coded din rail mounted terminals for easy thermostat wire connections• 24VAC output signal for activating field installed water circulating pump or isolation valve• Factory installed freeze protection to prevent water coil from freezing during non-use.• Activates water circulation at 40°F and deactivates at 60°F.• Plug-and-play installation and service
COMPATIBLE BOX SIZE• Industry standard footprint for retrofit applications• Appliance shell dimensions:
43-1/8" High x 28" Wide x 32” Deep• Wall Sleeve dimensions where penetrating exterior wall:
44-7/8" High x 28-7/8" Wide • Standard TAUPE color • Custom color options are available
SERVICE ADVANTAGES
• Indoor access to all parts & maintenance needs• Innovative, dual slide-out chassis can be partially or fully removed for efficient servicing.• Hot water coils are equipped with manual drain and vent valves for flushing water and
releasing of trapped air during installation or servicing.• Extended water inlet & outlet copper tube connections (3/4” water pipe) for easy
installation. • With spare modules, building management can perform quick swap outs, maintaining
indoor conditions in the apartment/condo, while troubleshooting non functioning units off line.
• All control harnesses are separated with modular quick disconnects so module swap outs do not require time consuming rewiring.
CIRCULATION BLOWER• Dual Inlet Blower for higher flow rates / reduced air noise• Endura Pro Multi-Speed Electronically Commutated Motor for increased electrical efficiency
FEATURES
HEATING MODULE
COOLING MODULE
INLE
T
OU
TLET
PSH - SERIESHydronic Heating / Electric Cooling
CONFORMS TO ANSI/UL STD. 1995, CERTIFIED TO CAN/CSA STD. C22.2 NO. 236 AND
ANSI/AHRI STD. 390
W415-1499 / A / 02.05.16
2
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
NOMENCLATURE
P=Condo Pack A, B, C
Gas Condensing
030 - 30 000 Btu/h 015 - 15 000 Btu/h
040 - 40 000 Btu/h 050 - 50 000 Btu/h
000 - No Heat
012 - 12 800 Btu/h / 1.0 Ton018 - 16 500 Btu/h / 1.5 Ton024 - 19 500 Btu/h / 2.0 Ton030 - 24 400 Btu/h / 2.5 Ton
000 - No CoolingAir Conditioning
P S C A A040 018HEAT
CAPACITYHEAT TYPE
COOLING CAPACITYMODELBRAND
COOLINGTYPE REVISION
S=Single Packaged Vertical
C - Gas CondensingS - Gas StandardE - ElectricalH - HydronicD - Duct only (No heat)
Hydronic Heat
030 - 30 000 Btu/h 000 - Duct Only 000 - Duct Only
042 - 42 000 Btu/h
E lectr ic Heat
005 - 5.0 kW 007 - 7.5 kW010 - 10 kW015 - 15 kW
Gas Standard(80%)
038 - 38 000 Btu/h 026 - 26 000 Btu/h
051 - 51 000 Btu/h 064 - 64 000 Btu/h
000 - Duct Only
Heat designation Heat designation
Heat designationHeat designation
A - Air Conditioning Standard Efficiency C - Air Conditioning High EfficiencyH - Heat Pump Standard Efficiency P - Heat Pump High EfficiencyF - Blower Only (No Cool) i.e. PSC040F000A
Example: PSC040A018A - Condo Pack- Single Packaged Vertical- Condensing Gas heating 40k Btu/h- AC 1.5 ton- Rev A
W415-1499 / A / 02.05.16
3
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
SPECIFICATIONS
ELEC
TRIC
AL A
ND
PHYS
ICAL
DAT
A
Elec
tric
and
Phy
sica
l Dat
a
Mod
el N
o.
Min
imum
Ci
rcui
t Am
paci
ty
(A)
Max
. O
verc
urre
nt
prot
ectio
n de
vice
(A)
COM
PRES
SOR
OU
TSID
E FA
N M
OTO
R IN
DOO
R BL
OW
ER
Com
p.
Rate
d Lo
ad
Amps
(R
LA)
Com
p Lo
cked
Ro
tor
Amps
(L
RA)
Nom
inal
RP
M
Rate
d Lo
ad
Amps
Cond
. M
otor
HP
Whe
el
Dia
x W
idth
(in
x in
)
Rate
d Lo
ad
Amps
HP
Voltage/Hz/Phase
Voltage Range
PSH0
30A0
12A
10.7
15
5.
5 26
1075
1 1/
6
10 x 6
2.8
1/3
208-230/60/1
197-253
PSH0
30A0
18A
15.1
20
9
48
1 1/
6 PS
H030
A024
A 20
.7
30
13.5
58
.3
1 1/
6 PS
H030
A030
A 20
.3
30
12.8
64
1.
5 1/
4 PS
H030
F000
A 3.
5 15
N
A N
A N
A N
A PS
H042
A012
A 10
.7
15
5.5
26
1 1/
6 PS
H042
A018
A 15
.1
20
9 48
1
1/6
PSH0
42A0
24A
20.7
30
13
.5
58.3
1
1/6
PSH0
42A0
30A
20.3
30
12
.8
64
1.5
1/4
PSH0
42F0
00A
3.5
15
NA
NA
NA
NA
TAB
LE 1
.
GEN
ERAL
PER
FORM
ANCE
DAT
A
Mod
el N
o.
COO
LING
HE
ATIN
G
Btuh
EE
R CF
M
208V
/230
V M
odel
No.
Bt
u/Hr
PS
H030
A012
A-TP
12
800
10.8
45
0
CHHM
030A
30
000
PSH0
30A0
18A-
TP
1650
0 9.
6 74
0 PS
H030
A024
A-TP
19
500
9.0
740
PSH0
30A0
30A-
TP
2440
0 9.
0 96
0 PS
H042
A012
A-TP
12
800
10.8
45
0
CHHM
042A
42
000
PSH0
42A0
18A-
TP
1650
0 9.
6 74
0 PS
H042
A024
A-TP
19
500
9.0
740
PSH0
42A0
30A-
TP
2440
0 9.
0 96
0
TAB
LE 2
.
W415-1499 / A / 02.05.16
4
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
HEATING MODULE PERFORMANCE MATRIX
Complete performance matrix from hydronic heating module
Coil (FH x FL: 12" X 19")
Air FLOW (CFM)
GPM Fluid Pressure Drop (Ft. Water)@ 130F
Coil Capacity (Btu/hr)
Inlet Water Temperature (F)
120F 130F 140F 150F 160F
CHHM030A (3 ROW)
388
1 0.65 11800 14000 16400 18900 21500
2 2.28 14100 16800 19600 22400 25200
3 4.77 14900 17800 20700 23700 26500
529
1 0.65 13600 16100 18700 21700 24600
2 2.28 16900 20100 23500 27000 30400
3 4.77 18200 21700 25300 29000 32600
744
1 0.65 15600 18500 21400 24700 28100
2 2.28 20500 24300 28400 32700 36900
3 4.77 22600 26800 31400 36000 40500
908
1 0.65 16600 19700 22800 26200 29800
2 2.28 22600 26700 31200 35900 40600
3 4.77 25200 29800 34900 40100 45200
971
1 0.65 16900 20100 23300 26700 30400
2 2.28 23300 27600 32100 37000 41900
3 4.77 26000 30900 36200 41500 46800
CHHM042A (4 ROW)
388
1 0.88 14000 16600 19300 22200 25100
2 3.02 16700 19800 23200 26500 29800
3 6.26 17600 21000 24400 27900 31400
529
1 0.88 16100 19100 22100 25400 28800
2 3.02 20400 24200 28200 32300 36400
3 6.26 21900 26100 30400 34800 39100
744
1 0.88 18300 21700 25200 28600 32600
2 3.02 24800 29400 34200 39300 44400
3 6.26 27500 32600 38000 43600 49000
908
2 3.02 27300 32400 37500 43100 48800
3 6.26 30800 36500 42600 48800 55100
4 10.52 32700 38800 45300 51900 58400
5 15.71 33900 40300 47100 53900 60500
971
3 6.26 31900 37800 44100 50600 57100
4 10.52 34000 40300 47200 54000 60800
5 15.71 35400 42100 49100 56200 63100
*All specifications and designs can change without notice to allow for on-going improvements. Images may not be exactly as shown. Consult with your owner’s manual for current information. Check all local and national building codes and gas regulations. Napoleon® is a registered trade mark of Wolf Steel Ltd.
TABLE 3.
W415-1499 / A / 02.05.16
5
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
AIR FLOW
CFM at External Static Pressure (Inches of Water Column) for CHHM030A-3ROW COIL Speed Tap#
Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 100% 999 967 939 909 875 833 780 682 595 544 2 85% 933 915 890 866 823 781 719 662 588 544 3 60% 779 755 734 707 673 643 609 578 537 484 4 35% 577 556 511 512 466 389 348 313 289 254 5 25% 472 421 388 340 292 251 229 199
CFM at External Static Pressure (Inches of Water Column) for CHHM042A-4ROW COIL Speed Tap#
Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 100% 980 943 918 883 852 800 750 633 578 495 2 85% 918 894 866 837 792 745 684 622 565 462 3 60% 768 737 716 684 656 622 582 555 515 461 4 35% 563 539 492 443 413 375 332 296 276 245 5 25% 458 404 371 322 276 234 218 198
Available Motor Speed Taps
Model No. Heating/Cooling Module Setting Speed
Tap# Model No. Heating/Cooling Module Setting Speed
Tap#
PSH030A012A
CHHM030A FACTORY 2
PSH042A012A
CHHM042A FACTORY 2
HI 1 HI 1
CACM012A FACTORY 5
CACM012A FACTORY 5
HI 4 HI 4 G - continuous fan 3 G - continuous fan 3
PSH030A018A
CHHM030A FACTORY 2
PSH042A018A
CHHM042A FACTORY 2
HI 1 HI 1
CACM018A FACTORY 3
CACM018A FACTORY 3
HI 2* HI 2* G - continuous fan 5 G - continuous fan 5
PSH030A024A
CHHM030A FACTORY 2
PSH042A024A
CHHM042A FACTORY 2
HI 1 HI 1
CACM024A FACTORY 3
CACM024A FACTORY 3
HI 2* HI 2* G - continuous fan 5 G - continuous fan 5
PSH030A030A
CHHM030A FACTORY 2
PSH042A030A
CHHM042A FACTORY 2
HI 1* HI 1*
CACM030A FACTORY 1
CACM030A FACTORY 1
HI NA HI NA G - continuous fan 5 G - continuous fan 5
*IMPORTANT: Do not use common motor speed tap for multiple functions; Connecting (any combination of) air conditioning blower speed, heating blower speed, and continuous fan speed to the same motor speed tap will cause the unit
to malfunction. Each of the three blower functions must be connected to separate motor speed taps.
TABLE 4.
TABLE 5.
TABLE 6.
W415-1499 / A / 02.05.16
6
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
WALL SLEEVE DIMENSIONS
32 34 "
26 12 "
12 916 "
"
16"
3 34 "
POSITION A
44 78 "
1" POSITION B
16"
28 78 "
42 14 "
WALL SLEEVE IS DIRECTLY LAGGEDTO WALL SUBSTRUCTURE.
TO IMPROVE RIGIDITY AND REDUCTION IN VIBRATION WALL MOUNTING,BRACKETS CAN BE USED TO AFFIX WALL SLEEVE TO BUILDING SUB STRUCTURE FROM INSIDE OR OUTSIDE BUILDING. ENGINEER/ARCHITECT TO CONSULT WITH NAPOLEON ENGINEERING TO DETERMINE BRACKET LOCATION FOR SETTING THE DESIRED DEPTH OF WALL SLEEVE INTO WALL.
46 78 "
1516
DIMENSIONS
W415-1499 / A / 02.05.16
7
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
ENCLOSURE FOR CONDO PACK
82"
REF.
A A
A-A
0" M
IN. C
LEA
RAN
CE
* 2"
MIN
. CLE
ARA
NC
E
10" M
IN.
CLE
ARA
NC
E
36"
DO
OR
OPE
NIN
G
29"
REF
.
1" R
EF.
DRA
IN R
EQUI
RED
(1
.5" Ø
MIN
.)FO
R RE
MO
VA
L O
F HE
ATIN
G M
OD
ULE
WA
TER
DRA
INA
ND
AC
CO
ND
ENSA
TE
DRA
IN
32 1
/8"
REF.
*
ROUG
H O
PEN
ING
TO
SUI
T 2
8 7/
8" X
44
7/8"
WA
LL S
LEEV
E
VIE
W O
F O
UTSI
DE
WA
LL
8" M
IN.
2" M
IN.
CLE
ARA
NC
E TO
CO
MBU
STIB
LE
**SE
CUR
E TO
WA
LL
FABR
ICA
TED
WO
OD
OR
STEE
L SU
PPO
RT
1" R
EF. C
LEA
RAN
CE
BETW
EEN
LEF
T (H
ING
E)SI
DE
DO
OR
JAM
AN
D C
ON
DO
PA
CK
44
7/8"
REF
. 4
4 7/
8" R
EF.
28
7/8"
NOTE
** En
gine
er/A
rchi
tect
- to
con
sult
with
Nap
oleo
n En
gine
erin
g to
det
erm
ine
brac
ket l
ocat
ion
for s
ettin
g th
e de
sire
d de
pth
of W
all S
leev
e in
to w
all.
CLE
ARA
NC
E FO
R SE
RVIC
ING
) (1
0" R
ECO
MM
END
ED M
IN.
FLO
OR
1.5"
Ø
Flas
hing
Flas
hing
12
9/16
"
16 "
Seal
aro
und
Slee
ve a
nd
OU
TS
IDE
wal
l
Seal
aro
und
Slee
ve a
ndIN
SID
E w
all
PRO
TRU
DE
1/2”
MIN
.-1” M
AX.
Bric
k W
all
PRO
TRU
DE
1/2”
MIN
.-1” M
AX.
Bric
k W
all
* If l
ess
then
10”
, se
rvic
ing
may
be
perfo
rmed
by
open
ing
the
front
doo
r pan
els
and
the
heat
ing
mod
ule
may
nee
d to
be
rem
oved
to a
cces
s co
mpo
nent
s.
Spac
e re
quire
d fo
r R
etur
n Ai
r Duc
ting
mus
t be
cons
ider
ed.
45
1/2"
45
3/8"
43
1/8"
W415-1499 / A / 02.05.16Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • phone 866-820-8686• fax 705-725-1150 • www.napo leonhea t ingandcoo l ing .com
8" M
IN
FLO
OR
32
1 8"
25
1 16"
29"
3
1 2"
8"
20
1 2" 15 16
" 1
6"
28
1 4"
53 8
" 2
41 4
" 3
1 8"
WA
TER
CO
NN
ECTI
ON
S 3/
4 W
ATE
R PI
PES
(7/8
OD
)
ELEC
TRIC
AL
CO
NN
ECTI
ON
24
1 8"
115 16
" 1
1 16" 7
1 8"
28
43
45
1 8"
AIR
SU
PPLY
O
UTL
ET
AIR
RET
URN
INLE
T
28"
7 8"
1 2"
45
3 8"
WA
TER
OU
TLET
(R
ETU
RN)
WA
TER
INLE
T(S
UPP
LY)
115 16
"
AC
DRA
IN12
9 16"
WA
LL S
LEEV
E
HEA
TIN
G
MO
DU
LE
CO
OLI
NG
M
OD
ULE
(AIR
C
ON
DIT
ION
ER)
CONDO PACK SHOWN IN WALL SLEEVE
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8
PHONE: 866-820-8686 • FAX: 705-725-1150Website: www.napoleonheatingandcooling.comGeneral: hvac@napoleonproducts.comTechnical inquiries: hvacsupport@napoleonproducts.com