Advanced Technology SolutionstoMeet your Lab’s Needs
Today’s LaboratoryChallenges
Laboratories continue to facea number of challenges.
These include clinical, operationaland financial issues such as:
• Demand for clinically relevant information• Medical technologist labor shortage• Increased workload• Need for faster turnaround time• Requirement for high reliability• Limited laboratory budgets
Fluorescent Flow CytometryYields Optimized Productivity
The Sysmex XT Automated Hematology Systemsutilize the power of fluorescent flow cytometry andhydrodynamic focusing technologies. Using a unique,diode laser bench, Sysmex fluorescent flow cytometryprovides the sensitivity needed for measuring anddifferentiating cell types in whole blood and bodyfluid samples. Fluorescent technology andhydrodynamic focusing enable the analyzers toconsistently classify normal WBC, RBC, and PLTpopulations from abnormal populations, therebydecreasing the number of manual interventions.
1
Even with these challenges, the need for hematology testinghas remained steady or continued to grow. Laboratoriesare searching for hematology analyzers that can improveproductivity and efficiency while providing enhancedclinical information. Designed to be reliable and efficient,the Sysmex XT-2000i and XT-1800i (XT) offers mediumvolume labs an automated hematology system that cantruly meet and exceed their expectations. The XT streamlinesyour workflow by providing testing for up to 80 samplesper hour, enabling rapid turnaround time.
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 2
Clinically Relevant Information
High Quality Hemoglobin(HGB) Analysis
The XT utilizes the cyanide-freereagent, Sodium Laurel Sulfate(SLS). The end product is a coloredcompound that is measuredspectrophotometrically. Since hemoglobindeterminations are performed from adilution and in its own separate chamber,there is no interference from high WBCcounts, lipemia or abnormal proteins.
Direct Hematocrit (HCT)Measurement
The cumulative pulse heights of all theRBC counts yield the HCT. This is basedon the principle that the pulse height(voltage change) produced by cellspassing through the aperture isproportional to cell volume.
RBCs and PLTs
RBCs and PLTs are counted in adedicated channel using Impedance orDirect Current (DC) detection methodcombined with hydrodynamic focusingtechnology. Challenges to cell countingsuch as coincidence or recirculationare circumvented and automaticdiscriminators separate the twocell populations.
Even with samples at extremelylow or unusually high concentrations,the XT-Series analyze RBCs and PLTswith uncompromised precisionand accuracy.
2
Hydrodynamic Focused Cell Counting
Effective Red CellDisorder Screening andTherapy Monitoring
The XT-Series provide the panelof standard parameters for basicand reliable anemia screeningand monitoring.
WBC, A Clear Differentiation
The combination of side scatter(cell complexity), forward scatter(cell size) and fluorescence (DNA &RNA concentration) of nucleated cellsprovides a concise and precise imageof each detected peripheral blood cell.
This 3-dimensional blood cell analysisprovides unique accuracy and precision.Fluorescence labeling of peripheralblood cells is a milestone for theroutine leukocyte differential.
Fluorescent technology enablesthe XT to reliably differentiate normalWBC populations from abnormal WBCpopulations. The sensitivity of theunique application of fluorescent flowcytometry gives the lab a high level ofconfidence in reporting accurate WBCdifferentials, even on critical patientsamples when the WBC count is low.
Conversion to SLS-Hgb
WBC Differential Scattergram
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 3
Advanced Clinical Parameters
3
Fluorescent Optical Platelet
Fluorescent Optical Platelet*
The XT-2000i offers both aFluorescent Optical Platelet (PLT-O)in addition to the traditional impedancePLT count. Flagging associated withatypical or abnormal platelets, due toincreased size or fragmentation isminimized by use of the opticalplatelet count. Accuracy in reportingis supported by the availability of bothtechnologies.
Fluorescent Optical Platelet is acomplementary, reportable parameterto the impedance platelet count.
The PLT-O parameter provides:
• Improved accuracy on lowplatelet counts
• Accurate counts when interferencesare present, thus reducing manualintervention
• Automated judgment for reportingPLT-O or impedance PLT throughinstrument settings, eliminatingtech-to-tech decision variability
*XT-2000i only
Body Fluids
The XT analyzers include measurementfor body fluids. These analyzers providereportable WBC and RBC countsfor all common body fluid samples(CSF, synovial and serous).
The analyzers apply provenimpedance and fluorescent flowcytometry technology ensuringan accurate body fluid count froma single sample analysis.
The XT Body Fluid Count provides:
• No sample pre-treatment• No additional reagents or
additional quality control materialrequirement
• An automatic background checkprior to analyzing a sample
The XT Body Fluid Count benefits:• Improved productivity• Decreased turnaround time (TAT)• Decrease manual technical
intervention
Immature Granulocytes(IG) Determination
• Cells included in the IG countare metamyelocytes, myelocytes,and promyelocytes
• The IG parameter is providedfrom the DIFF channel
• The IG software applies a flexiblegating algorithm tailored toindividual samples, thus providingreliable IG counts
The IG Parameter provides:
Improved accuracy and sensitivity• Reduced false positive and
false negative rates• Result consistency by reducing
tech-to-tech variation in reportingmanual differentials
Improved workflow• Fewer manual differentials means
faster turnaround time (TAT)
Labor savings• Fewer manual slide reviews improves
laboratory efficiency and supportshigher laboratory output
Body FluidImmature Granulocyte Count
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 4
One Comprehensive System
4
With the use of fluorescent technology, the reticulocyte count assures:
• Accurate reticulocyte % and #• Improved immature reticulocyte fraction (IRF) information for earlier diagnosis
and treatment by clinicians• Elimination of common interferences from Howell-Jolly bodies,
Pappenheimer bodies and immature reticulocytes to avoid manual counts
In addition, the Reticulocyte Hemoglobin (RET-He), is a parameter measuredin the reticulocyte channel which is used to measure the incorporation of ironinto erythrocyte hemoglobin.
The RET-He parameter supports:
• Rapid, direct analysis of an earlier stage of RBC development forprompt clinical follow-up
• Assessment of anemia. RET-He is an established parameter used inKDOQI (Kidney Disease Outcomes Quality Initiative) guidelines for assessingthe initial iron status of patients
• Accuracy and sensitivity in measurement of red cell production that aidsthe clinician in effective monitoring of costly drug protocols for cell stimulation
*XT-2000i only
Fluorescent Reticulocyte Count
Reticulocyte Analysis*
Known as the “Gold Standard”reticulocyte testing parameter, thefluorescent reticulocyte count isavailable on the XT-2000i. Sysmexwas one of the first companies toprovide on-board retic testing ina dedicated channel, which improvedefficiencies in reticulocyte counting.
Positive PatientSample withRetic Analysis
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 5
5
Improved Productivity & Efficiency
e-Tools: Assuring Qualityand Optimizing Performance
SNCSTM, Sysmex NetworkCommunications System, is proprietarysoftware which enables fast, securecommunication from your analyzer toSysmex servers using a high-speed,outbound internet connection. Thispowerful tool is the instrument datalink feeding a variety of innovativetools and services.
InsightTM
Insight is a web-based InterlaboratoryQuality Assessment Program (IQAP)which allows on-demand qualitycontrol reporting with access anytime,anywhere. Insight meets therequirements to document peercomparison data for your analyzerwhile eliminating manual steps.
Remote Monitoring
Continuous collection andmonitoring of instrument performancedata is linked to our tracking anddispatch system. We monitor yourinstrument performance, instrumentconfiguration settings and back-upsettings continuously.
Make your lab more efficient with:
• Unobtrusive, remote andreal-time monitoring
• Proactive identification andfollow-up of potential issues
• Enhanced first-time field fixes,if needed
e-Supply – ReagentInventory Management
The e-Supply program offers onlinereagent monitoring that simplifiesboth ordering and inventory processes.
This innovative program helps you:
• Track reagent usage and inventory• Maintain appropriate inventory levels• Reduce your shipping cost
Sysmex WAM™
The XT can be used in conjunctionwith Sysmex WAM DecisionSupport Software for the ClinicalLaboratory, which enhances sampleand data workflow and improvesturnaround time (TAT).
For the Mid VolumeLaboratory
The XT offers comprehensiveclinical testing menus for wholeblood and body fluids, providingaccurate, precise and sensitiveresults. Your clinicians receive qualityresults to assist in the diagnosis,management and therapeuticmonitoring of disease states.
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 6
6
Principles & Technologies Fluorescent Flow Cytometry:WBC-Diff
DC-Sheath-Flow:RBC, HCT, PLT
Cyanide-free SLS-Method:HGB
21 Whole Blood Reportable WBC, RBC, HGB, HCT, MCV, MCH, MCHC,Parameters PLT (Impedance and Fluorescent Optical)
NEUT%, LYMPH%, MONO%, EO%, BASO%,NEUT#, LYMPH#, MONO#, EO#, BASO#,RDW-SD, RDW-CV, MPV
Additional Parameters
IG XT-2000i StandardXT-1800i Optional
RET-He XT-2000i Optional
2 Body Fluid Reportable Parameters WBC-BF, RBC-BF
Linearity WBC: 0.00 – 440.0 x 103/µLRBC: 0.00 – 8.00 x 106/µLPLT: 0 – 5,000 x 103/µL
Throughput Whole Blood: 80 samples/hour (max.)Body Fluid: 30 samples/hour (max.)
Sample Volumes Closed Mode: 150μLManual Mode: 85μLCapillary Mode: 40μL
Data Storage 10,000 samples (including graphics)(IPU: Information Processing Unit)
Quality Control Comprehensive QC files including(Total QC Management) “current” and “new” lot feature
Levey-Jennings control chartX-barM fileOnline Quality Assurance
Program – InsightTM
Interfaces ASTMSysmex WAMTM (HL7 & ASTM)
Dimensions / Weight Main unit (including sampler):w x h x d [in] / [lbs] 20.9 x 24.8 x 28.3 / 129.8
SysmexXT-2000i™ and XT-1800i™
Specifications
MKT-10-1136:MKT-10-1136 5/22/12 9:04 AM Page 7
Sysmex Corporation