Post on 27-Jun-2018
FOR all inDicationS*!
The Straumann® Dental Implant System offers you and your patients
efficient and esthetic implant-borne restorations for a wide range of indi-
cations, giving you the flexibility you need in your treatment.
Single tooth missing
Partially edentulous
Fully edentulous
*From single teeth to edentulous solutions
2
Simplicity anD eFFiciency: SOFT TISSUE LEVEL SOLUTIONS
Straumann® Soft Tissue Level is one of the most
widely used soft tissue implant lines. With 10-year
long-term results for SLA®1, it is the ideal partner in
your practice and the right choice for your patient
treatment.
DeSigneD to Save time anD increaSe eFFiciency in your Practice2
Soft Tissue Level implant aims at reducing chair time and minimizing treatment complexity
Designed to provide integrated soft tissue management through built-in machined collar design
High treatment success and patient satisfaction supported by strong scientific evidence3
Placement of an implant Healing cap Placement of a provisional abutment
treatment workFlow on SoFt tiSSue level imPlant SolutionS
3
take aDvantage oF tHe eaSy acceSSibility to tHe imPlant by working at SoFt tiSSue level
Lean prosthetic portfolio supported by the implant design Abutment-level impression makes workflow efficient and
number of patient visits can be minimized4
Simple impression taking and abutment placement due to the connection at soft tissue level
reDucinG TREATMENT compleXity
conventional impression taking insertion of the abutment crown in place
4
The Straumann® Bone Level implant line provides
you with additional flexibility to deliver an optimal
esthetic solution to patients. Bone Level implants
complement the Straumann® Soft Tissue Level port-
folio to offer you wide treatment flexibility and man-
ifold options.
eStHeticS anD FleXiBilty: BONE LEVEL IMPLANT SOLUTIONS
excellent eStHeticS Due to bone PreServation5,6 anD Smart SoFt tiSSue management
Stable crestal bone supporting esthetic outcome5,6
Exclusive self-guiding CrossFit® connection designed for a precise fit and stability
A wide range of treatment options with the convenience of a confident solution at bone level
the precise and self-guiding crossFit® connection
bone level imPlant
5
DeSigneD For outStanDing eStHetic reSultS anD Flexibility in reStorative ProceDureS
Broad range of materials and restorative options designed for an optimal result in every treatment step
Natural appearance through full ceramic restorations with customized or standard abutments
Smart soft tissue management from start to finish with Consistent Emergence Profiles™
FOR A WiDe ranGe oF treatment optionS
Healing abutment temporary restoration Final restoration
conSiStent emergence ProFileS™
Consistently matching geometries throughout the entire work flow
Eases the fabrication of temporary and final restorations Excellent esthetic results5,6
6
For years, implants with the SLA® surface have de-
livered excellent results and high implant success
rates.7,8 Straumann followed this state-of-the-art
development in implant dentistry with the SLActive®
surface, the next generation in surface technology.
Promoting faster osseointegration and providing
higher predictability, SLActive® has become a cen-
tral feature of the implant portfolio.
A LEADING SurFace innoVation: SLActive®
more conFiDence tHrougH HigHer PreDictability9,10,11
SLActive® designed to deliver:
Higher security and faster osseointegration for every indication9,10,12–17
Reduced healing times from 6–8 weeks down to 3–4 weeks11
Increased treatment predictability in critical protocols9
7
Roxolid®, the new “DNA” of implant materials, is a
titanium-zirconium alloy, specifically developed for
dental implantology. Roxolid® is designed to widen
your treatment options with small diameter implants.
Mechanical tests have demonstrated higher tensile
and fatigue strength of Roxolid® implants compared
to titanium grade 4 implants.18,19 In combination
with the SLActive® surface, Roxolid® brings high
strength and excellent osseointegration properties
to the Straumann® Dental Implant System portfolio.
roxoliD® tHe new “Dna” oF imPlant materialS
Confidence when placing small diameter implants Flexibility of having more treatment options Designed to increase patients’ acceptance of implant
treatment
DRIVING material innoVation: ROXOLID®
8
Simplicity: ONE SYSTEM
The proven Straumann® Dental Implant System (SDIS)
is a broad portfolio of Soft Tissue and Bone Level
implants that allows you to deliver an optimal treat-
ment to your patients.
imPlant PortFolio
the classic implant for one-stage surgery
the implant for flexible
healing protocols
the implant for immediate
placement and superior pri-
mary stability
the implant for confidence and esthetics at bone level
most common clinical situations
Straumann® Standard
Straumann® Standard Plus
Straumann® Tapered Effect
Straumann® Bone Level
Anterior region
Posterior region
Small interdental space (NN)
Thin mucosa biotype
Thick mucosa biotype
Bone augmentation with simultaneous implant placement
Submerged healing
Non-submerged healing
Immediate implant placement in extraction socket
Internal sinus lift
Highly recommended Recommended
Please note that the size limitations according to the instructions for use of each Straumann® product apply and must be observed. Each Straumann® product must be used in accordance with the instructions for use provided by Straumann. It is the practitioner’s responsibility to use the device in accordance with these instructions for use and to determine if the device fits the individual patient situation.
9
Straumann® Surgical cassette Straumann® guided Surgery cassette
Simplicity: ONE INSTRUMENT KIT
For your convenience, the appropriate Straumann®
surgical instrument kit can be used for all implant
lines of the Straumann® Dental Implant System, in
both conventional and guided surgery.
Straumann® inStrument kit
For eaSe oF HanDling
The easy-to-read user guide ensures a reliable working sequence through color-coded arrows and silicone sleeves
The cassette can be packed to reflect the working procedure (which is performed either using the handpiece or manually with the ratchet)
Clear illustrations and drill length stops confirm, at a glance, that the arrangement of instruments, screws and healing caps is complete and correct
PROSTHETIC OPTIONS COVERING A Variety oF inDicationS
Choose between different materials and follow
your preferred workflow! The Straumann® prosthet-
ics portfolio offers you the esthetics and flexibility
you need in your practice.
cHooSe tHe accurate ProStHetic oPtion
Solid abutments are designed to facilitate the restoration of implants
Flexible and comprehensive synOcta® portfolio offers the perfect restorative solution
Easy to achieve esthetics with anatomic abutments
titanium gold ceramics cobalt-chrome
Cementable
Solid
synOcta® Cementable
synOcta® Angled
Anatomic
CADCAM
synOcta® 1.5
Multi-Base Straumann® CARES® Screw-retained bridge
synOcta® Gold
Gold
Anatomic IPS e.max® Abutment
CADCAM
Straumann® CARES® Screw-retained bridge
Single tooth
Screw-retained
Cemented
Partially edentulous
Screw-retained
Cemented
basic Solutions advanced Solutions Premium Solutions
LOCATOR®
Bar
Retentive anchor
Individualized bar
Telescopic constructions
synOcta® 1.5
Multi-Base Gold
Straumann® CARES® Screw-retained Dolder® Bar
Straumann® CARES® Screw-retained bridge
Fully edentulous
Removable overdentures
Fixed overdentures
ProStHeticS PortFolio
Soft Tissue Level implants Bone Level implants
Natural-looking esthetics with CADCAM abutments Flexible and comprehensive Multi-Base portfolio designed
for perfectly fitting screw-retained multiple unit restorations Due to their standard designs, LOCATOR® and bar
components are ready to use in a variety of indications
titanium gold ceramics cobalt-chrome
Cementable
Solid
synOcta® Cementable
synOcta® Angled
Anatomic
CADCAM
synOcta® 1.5
Multi-Base Straumann® CARES® Screw-retained bridge
synOcta® Gold
Gold
Anatomic IPS e.max® Abutment
CADCAM
Straumann® CARES® Screw-retained bridge
Single tooth
Screw-retained
Cemented
Partially edentulous
Screw-retained
Cemented
basic Solutions advanced Solutions Premium Solutions
LOCATOR®
Bar
Retentive anchor
Individualized bar
Telescopic constructions
synOcta® 1.5
Multi-Base Gold
Straumann® CARES® Screw-retained Dolder® Bar
Straumann® CARES® Screw-retained bridge
Fully edentulous
Removable overdentures
Fixed overdentures
12
5
Bone Control Design™ is an implant design which
has been applied consistently to the Straumann®
Dental Implant System. It is built on 5 key factors for
bone preservation and thus provides a crucial foun-
dation for esthetic results and long-term success.
reliaBility: BONE CONTROL DESIGN™
The Straumann® Dental Implant System is your reli-
able partner in implant treatment, giving you simple
and convenient solutions – for your success!
1. Respecting the biological distance
oPtimize creStal bone PreServation
2. Optimal position of smooth and rough surface interface
3. Biomechanical implant design
4b. Microgap control Bone Level
4a. Microgap control Soft Tissue Level
5. Implant surface osteoconductivity
3
REFERENCES
1 Fischer K. ITI World Symposium. 2010 15–17 Apr; Geneva; Switzerland. 2 Applicable to simple cases according to the ITI rating. 3 Straumann® SLA Scientific Evidence first edition (2011). 4 Applicable to simple cases according to the ITI rating and using a solid
abutment. 5 Buser D et al. Stability of Contour Augmentation and Esthetic Outcomes
of Implant-supported Single Crowns in the Esthetic Zone. 3-Year Results of a Prospective Study With Early Implant Placement Postextraction. J. Periodontol. 2011;82(3):342–349.
6 Cordaro L et al. Submerged vs non-submerged healing of implants for single tooth replacement in the aesthetic zone: results from a multicentre RCT. Oral presentation at Annual Meeting of EAO, 2010 in Glasgow (UK).
7 Bornstein M.M. et al. Early loading of non-submerged titanium implants with a sandblasted and acid-etched surface. 5-year results of a pro-spective study in partially edentulous patients. Clin. Oral Implants Res. 2005;16:631–638.
8 Roccuzzo M. et al. Early loading of sandblasted and acid-etched implants: a randomized-controlled double-blind split-mouth study. Five-year results. Clin. Oral Implants Res. 2008;19:148–152.
9 Ganeles J, Zöllner A, Jackowski J, ten Bruggenkate C, Beagle J, Guerra F. Immediate and early loading of Straumann implants with a chemically modified surface (SLActive®) in the posterior mandible and maxilla: 1-year results from a prospective multicenter study. Clin. Oral Impl. Res. 2008;19:1119–1128.
10 Bornstein MM, Wittneben JG, Brägger U, Buser D. Early loading at 21 days of non-submerged titanium implants with a chemically modified sandblasted and acid-etched surface: 3-year results of a prospective study in the posterior mandible. J. Periodontol. 2010 Jun;81(6):809–818.
11 Oates TW, Valderrama P, Bischof M, Nedir R, Jones A, Simpson J, Toutenburg H, Cochran DL. Enhanced implant stability with a chemically modified SLA® surface: a randomized pilot study. The International Journal of Oral & Maxillofacial Implants. 2007;22(5):755–760.
12 Luongo G, Oteri G. A noninterventional study documenting use and success of implants with a new chemically modified titanium surface in daily dental practice. J. Oral Implantol. 2010;36(4):305–314.
13 Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Bone regeneration in dehiscence-type defects at chemically modified (SLActive) and conventional SLA titanium implants: A pilot study in dogs. Journal of Clinical Periodontology. 2007;34(1):78–86.
14 Schwarz F, Ferrari D, Herten M, Mihatovic I, Wieland M, Sager M, Becker J. Effects of surface hydrophilicity and microtopography on early stages of soft and hard tissue integration at non-submerged titanium implants: An immunohistochemical study in dogs. Journal of Periodontology. 2007;78(11):2171–2184.
15 Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Histological and immunohistochemical analysis of initial and early subepithelial connective tissue attachment at chemically modified and conventional SLA® titanium implants. A pilot study in dogs. Clinical Oral Implants Research. 2007;11(3):245–455.
16 Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J. Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA® titanium implants: Preliminary results of a pilot study in dogs. Clinical Oral Implants Research. 2007;11(4):481–488.
17 Buser D, Broggini N, Wieland M, Schenk RK, Denzer AJ, Cochran DL, Hoffmann B, Lussi A, Steinemann SG. Enhanced bone apposition to a chemically modified SLA titanium surface. J. Dent. Res. 2004 Jul;83(7): 529–533.
18 Norm ASTM F67 (states min. tensile strength of annealed titanium). 19 Data on file, used for all Straumann® titanium and Roxolid® implants.
International HeadquartersInstitut Straumann AG Peter Merian-Weg 12CH-4002 Basel, SwitzerlandPhone +41 (0)61 965 11 11Fax +41 (0)61 965 11 01
www.s t raumann.com
Stra
uman
n pr
oduc
ts ar
e C
E m
arke
d
03/
12
152.
912/
en
BG
2101
2
Dolder® is a registered trademark from Prof. Eugen Dolder, former director, School of Dentistry of Zurich. IPS e.max® is a registered trademark of Ivoclar Vivadent AG, Liechtenstein. LOCATOR® is a registered trademark of Zest Anchors, Inc., USA. Some items of the Straumann® Dental Implant System are not available in all countries.
© Institut Straumann AG, 2012. All rights reserved. Straumann® and/or other trademarks and logos from Straumann® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved.