Post on 10-Apr-2020
Data SheetSS/264XR_5
ABB 2600T SeriesEngineered solutions
for all applications
Base accuracy : ±0.075%
Span limits– 0.2 to 60000kPa; 0.8inH2O to 8700psi– 0.54 to 16000kPa abs; 4mmHg to 2320psia
Reliable sensing system coupled with very latestdigital technologies
Comprehensive sensor choice– optimize in-use total performance and stability
5–year stability
Flexible configuration facilities– provided locally via local keys combined with LCD
indicator or via hand held terminal orPC configuration platform
Multiple protocol availability– provides integration with HART®, PROFIBUS PA
and FOUNDATION Fieldbus platforms offeringinterchangeability and transmitter upgradecapabilities
Broad selection of variants, options fill fluids andwetted materials
– allows total flexibility maximizing cost-effectiveaspect, also providing applications with criticalprocess media at extended temperature range
PED compliance to sound engineering practice(SEP)
FieldIT
2600T Series Pressure Transmitters
Model 264DR Differential Models 264PR and 264HR Gauge
Models 264VR and 264NR Absolutewith remote seal(s)
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
2
Functional SpecificationsRange and span limits
– models 264DR/264PR/264VR
General DescriptionModels detailed in this data sheet apply for those transmitters whichinclude one or two remote seal(s) connected via a capillary to thetransmitter sensor. Depending on the selected ordering code thefollowing models are available:a) model 264DR which allows a differential measurement using either
two remote seals of same type and size or one remote seal (onpositive or negative side) and a standard threaded connection direct1/4 – 18 NPT on flange or 1/2 – 14 NPT through adapter, for the wet ordry leg on the side opposite to seal.
b) models 264PR or 264VR allowing gauge or absolute measurementrespetively with the reference side at atmosphere or at vacuum. Theother side which can be the positive or negative (high or low pressureside) features the required remote seal.
Model 264HR or 264NR have the remote seal on the positive side and theuser can select the suitable code for having the reference at armosphericor vacuum pressure respectively for gauge or absolute measure.
The following table list the types of standard seal which can be combinedwith 264xR transmitters (the mnemonic is used as reference in thecompatibility table of page 3).
Refer to seal data sheet for all data and details relevant to seal element.
All following specification data apply for identical characteristics of the twosides when the transmitter is differential with two seals.
rosneSedoC
timiLegnaRreppU)LRU(
)LRL(timiLegnaRrewoLmuminiM
napsRD462
laitnereffiderusaem
RP462eguag
erusaem
RV462etulosbaerusaem
BaPk4
rabm04Hni61 2O
aPk4–rabm04–
Hni61– 2O
aPk2.0rabm2
Hni8.0 2O
EaPk61
rabm061Hni46 2O
aPk61–rabm061–
Hni46– 2O
aPk61–rabm061–
Hni46– 2O
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk45.0rabm4.5
Hni61.2 2O
FaPk04
rabm004Hni061 2O
aPk04–rabm004–
Hni061– 2O
aPk04–rabm004–
Hni061– 2O
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk76.0rabm7.6
Hni76.2 2O
GaPk56
rabm056Hni062 2O
aPk56–rabm056–
Hni062– 2O
aPk56–rabm056–
Hni062– 2O
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk1.1rabm11
Hni53.4 2O
HaPk061
rabm0061Hni246 2O
aPk061–rabm0061–
Hni246– 2O
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk76.2rabm7.62
Hni7.01 2O
MaPk006
rab6isp78
aPk006–rab6–isp78–
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk01rab1.0isp54.1
PaPk0042
rab42isp843
aPk0042–rab42–isp843–
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk04rab4.0isp8.5
QaPk0008
rab08isp0611
aPk0008–rab08–
isp0611–
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk431rab43.1isp4.91
SaPk00061
rab061isp0232
aPk00061–rab061–isp0232–
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk762rab76.2isp7.83
ledoM epytlaeS eziS cinomenM
W462SrefaW
)doof(refaW
1 1/2 04ND/ni05ND/ni208ND/ni3
5.1P2P3P
C462SeetlacimehC
degnalfni3 3P
A462SE462SR462S
degnalFmgarhpaidhsulf)tnioJgniRosla(
-1 1/2 )ylnoJREMSA(ni05ND/ni2
001-08ND/ni4-3
5.1P2P3P
degnalFdednetxemgarhpaid
05ND/ni208ND/ni3001ND/ni4
2E3E3P
U462S noinU 1 1/2n 5.1Z
T462S enil-ffodedaerhT 2 1/2 ni 5.2T
M462S enil-ffodegnalF 2 1/2n 5.2T
S462S
tunnoinUpmalcirT
lerruByrrehCcitpesA,yratinaS
05F/ni208F/ni3
ni4
2S3S3S
B462S nottuB ni1 1B
P462SecivresaerU
degnalf1 1/2 ni2 1/2 ni
5.1U5.2U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
3
Lower Range Limit (LRL) for 264NR is 0.07kPa abs, 0.7mbar abs,0.5mmHg for all ranges
(§) Lower Range Limit is 0.135kPa abs, 1.35mbar abs, 1mmHg forinert Galden or 0.4kPa abs, 4mbar abs, 3mmHg for inert Halocarbon.
– models 264HR/NR Span limits
Maximum span = URL(can be further adjusted up to ± URL (TD = 0.5) for differentialmodels, within the range limits)
IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSORCODE PROVIDING THE TURNDOWN VALUE AS LOWEST ASPOSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS.
Zero suppression and elevation
Zero and span can be adjusted to any value within the range limitsdetailed in the table as long as:
– calibrated span ≥ minimum span
DampingSelectable time constant : 0, 0.25, 0.5, 1, 2, 4, 8 or 16s.This is in addition to sensor response time
Turn on time
Operation within specification in less than 1s with minimumdamping.
Insulation resistance
> 100MΩ at 1000VDC (terminals to earth)
The combinations sensor code/seal type marked (•) modify the base accuracy rating and static pressure effect; refer to performance specifications.Although he above table defines capillary length, for some types of seal combined to the sensor, care should be taken of the maximum workingpressure of the used seal which can limit the range.
Refer to ABB for data related to application of capillary lengths greater than those specified in above table.
rosneSedoC
egnaRreppU)LRU(timiL
egnaRrewoL)LRL(timiL
RH462rof
napSmuminiM
RH462 RN462
GaPk56
rabm056Hni062 2O
aPk56–rabm056–
Hni062– 2O
aPk1.1rabm11
Hni53.4 2O
aPk1.1rabm11gHmm8
HaPk061
rabm0061Hni246 2O
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk76.2rabm7.62
Hni7.01 2O
aPk76.2rabm7.62
gHmm02
MaPk006
rab6isp78
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk01rab1.0isp54.1
aPk01rab1.0isp54.1
PaPk0042
rab42isp843
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk04rab4.0isp8.5
aPk04rab4.0isp8.5
QaPk0008
rab08isp0611
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk431rab43.1isp4.91
aPk431rab43.1isp4.91
SaPk00061
rab061isp0232
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk762rab76.2isp7.83
aPk762rab76.2isp7.83
VaPk00006
rab006isp0078
)§(sbaaPk70.0)§(sbarabm7.0
)§(gHmm5.0
aPk0002rab02isp092
rosneSedoC
)stekarbni)m(htgnelyrallipacmumixamhtiwsepytlaesdewolla(ytilibitapmoCnoitarugifnoctnemerusaemsusrev
laitnereffiD)slaesowt(
laitnereffiddnaeguag)laeseno(
etulosba)laeseno(
B )5.1(3P)•5.1(3S)•1(5.2T)•1(3E
E )3(3P)•3(3S,)•2(5.2T,)•2(3E
)1(3P)1(3S
)1(3P)1(3S
G-F )3(5,2T,)4(3E,)2(2E,)6(3P,)3(2P)6(3S,)•1(2S,)3(5.2U
)2(5,2T,)3(3E,)4(3P,)2(2P)4(3S,)3(5.2U
)2(5,2T,)3(3E,)3(3P,)2(2P)3(3S,)3(5.2U
H )6(3E,)6(2E,)8(3P,)8(2P,)4(5.1P)01(3S,)3(2S,)6(5.2U,)6(5.2T
,)3(5.1Z,)8(3E,)4(2E,)01(3P,)6(2P,)3(5.1P)01(3S,)2(2S,)6(5.2U,)6(5.2T
)6(3E,)3(2E,)8(3P,)5(2P,)3(5.1P)8(3S,)2(2S,)5(5.2U,)5(5.2T
M ,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)6(5.2T
,)5(5.1Z,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)5(5.1U,)6(5.2T
,)6(3E,)5(2E,)8(3P,)6(2P,)4(5.1P)8(3S,)5(2S,)5(5.2U,)4(5.1U,)5(5.2T
P ,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)6(5.2T
,)5(5.1Z,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)5(5.1U,)6(5.2T
,)6(3E,)5(2E,)8(3P,)6(2P,)4(5.1P)8(3S,)5(2S,)5(5.2U,)4(5.1U,)5(5.2T
Q ,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)6(5.2T
,)5(5.1Z)•3(1B,)8(3E,)6(2E,)01(3P,)8(2P,)5(5.1P)01(3S,)6(2S,)6(5.2U,)5(5.1U,)6(5.2T
,)6(3E,)5(2E,)8(3P,)6(2P,)4(5.1P)8(3S,)5(2S,)5(5.2U,)4(5.1U,)5(5.2T
S ,)01(3P,)8(2P,)5(5.1P)6(5.2U,)6(5.2T
,)5(5.1Z,)01(3P,)8(2P,)5(5.1P)•3(1B,)6(5.2U,)5(5.1U,)6(5.2T
,)8(3P,)6(2P,)4(5.1P)5(5.2U,)4(5.1U,)5(5.2T
V )6(5.2U,)5(5.1U,)3(1B
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
4
Operative limits
Temperature limits °C (°F) :
Ambient (is the operating temperature)
Lower ambient limit for LCD indicators: –20°C (–4°F)
Upper ambient limit for LCD indicators: +70°C (+158°F)
Note : For Hazardous Atmosphere applications see the temperaturerange specified on the certificate/approval relevant to the aimedtype of protection
Process
Lower limit (side without seal for 264DR only)
– refer to lower ambient limits; –20°C (–4°F) for Viton gasket
Upper limit (side without seal for 264DR only)
– Silicone oil: 121°C (250°F) (1)
– Inert fluid: 100°C (212°F) (2)
(1) 100°C (212°F) for application below atmospheric pressure
(2) 65°C (150°F) for application below atmospheric pressure
The following table show characteristics of capillary/seal fill fluids whenused in transmitters with remote seal.
Fill fluids with FDA are defined as food fills and are Generally RecognizedAs Safe (GRAS) by the US Food and Drug Administration (FDA).
REFER ALSO TO S264 DATA SHEET FOR FURTHER LIMITATIONDUE TO SEAL VARIANTS.
Storage
Lower limit: –50°C (–58°F); –40°C (–40°F) for LCD indicators
Upper limit: +85°C (+185°F)
Pressure limitsRefer to seal specification sheet for maximum working pressure relatedto the used remote seal.
Overpressure limits (without damage to the transmitter)
0.07kPa abs, 0.7mbar abs, 0.01psia (0.135kPa abs, 1.35mbar abs,1mmHg for inert Galden or 0.4kPa abs, 4mbar abs, 3mmHg for inertHalocarbon) to transmitter sensor limit or flange rating of seal,whichever is less:
– 21MPa, 210bar, 3045psi for models 264DR, 264PR and 264VR(except 7MPa, 70bar, 1015psi for sensor code B and 16MPa,160bar, 2320psi for sensor code E)
– 21MPa, 210bar, 3045psi for models 264HR/NR sensors P,Q,S
– 14MPa, 140bar, 2030psi for models 264HR/NR sensors G,H,M
– 90MPa, 900bar, 13050psi for model 264HR sensor V.
Static pressure
Transmitters for differential pressure model 264DR operates withinspecifications between the following limits:
– 1.3kPa abs,13mbar abs, 0.2psia and 21MPa, 210bar, 3045psi(except 7MPa, 70bar, 1015psi for sensor code B and 16MPa,160bar, 2320psi for sensor code E).
– 0.07kPa abs,0.7mbar abs, 0.1psia and 21MPa, 210bar, 3045psi(except 7MPa, 70bar, 1015psi for sensor code B and 16MPa,160bar, 2320 psi for sensor code E) or flange rating of sealwhichever is less, using two remote seals on both transmitter side.
Proof pressure
The transmitter can be exposed without leaking to line pressure of up to
– 28MPa, 280bar, 4000psi for model 264DR, 264PR and 264VR andfor sensor codes G,H,M of models 264HR and 264NR
– 40MPa, 400bar, 5900 psi for sensor codes P,Q,S of models264HR/NR
– 90MPa, 900bar, 13050 psi for sensor code V of model 264HR
or two times the flange rating of seal, whichever is less
Meet ANSI/ISA–S 82.03 hydrostatic test requirements and SAMAPMC 27.1.
gnilliF
sledoMRV/RP/RD462
sledoMRN/RH462
ledoMRH462
srosneSSotF
srosneSE,B
srosneSSotG
rosneSV
lioenociliS002CD
58+dna04–)581+dna04–(
58+dna52–)581+dna31–(
58+dna04–)581+dna04–(
58+dna04–)581+dna04–(
trenInedlaG
58+dna02–)581+dna4–(
58+dna01–)581+dna41+(
58+dna02–)581+dna4–(
trenInobracolaH
58+dna02–)581+dna4–(
58+dna01–)581+dna41+(
58+dna02–)581+dna4–(
SDIULFLLIF)NOITACILPPA(
SNOITIDNOCGNITAREPO
xamTfo>sbaP@
nimPsbarabm
)aisp(
xamTnimP@
nimT
002CD-lioenociliS)esopruplareneG(
)093(002rabm53@
7.0)10.0(
061)023(
04–)04–(
041NA-lioenociliS)erutarepmethgiH(
)617(083rab1@
7.0)10.0(
003)275(
5–)32+(
TLXmrehtlyS–remyloPenociliS)erutarepmetwoL(
)212(001rabm011@
2)30.0(
02)86(
001–)841–(
02-MeeboeN-lioelbategeVADF)yratinaS-dooF(
)093(002rab1@
031)9.1(
051)003(
81–)0(
)%07(retaWnirecylGADF)yratinaS-dooF(
)002(39rab1@
0001)5.41(
39)002(
7–)02+(
28LOCRAM-liolareniMADF)yratinaS-dooF(
)093(002rabm002@
33)5.0(
04)401(
04–)04–(
nedlaG–trenI)ecivreSnegyxO(
)023(061rab1@
7.0)10.0(
56)051(
81–)0(
2.4nobracolaH–trenI)ecivreSnegyxO(
)653(081rabm004@
4)60.0(
07)851(
02–)4–(
llifBBA)slaicepsdnastniaP(
)275(003rabm004@
7.0)10.0(
061)023(
01–)41+(
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
5
Environmental limits
Electromagnetic compatibility (EMC)
Comply with EN 61000–6–3 for emission and EN 61000–6–2 forimmunity requirements and test;
Radiated electromagnetic immunity level: 30V/m(according to IEC 1000–4–3, EN61000–4–3)
Conducted electromagnetic immunity level : 30V(according to IEC 1000–4-6, EN 61000–4–6)
Surge immunity level (with surge protector): 4kV(according to IEC 1000-4–5 EN 61000–4–5)
Fast transient (Burst) immunity level: 4kV(according to IEC 1000–4–4 EN 61000–4–4)
Pressure equipment directive (PED)
Comply with 97/23/EEC following sound engineering practice (SEP).
Humidity
Relative humidity: up to 100% annual average
Condensing, icing: admissible
Vibration resistance
Accelerations up to 2g at frequency up to 1000Hz(according to IEC 60068–2–6)
Shock resistance (according to IEC 60068–2–27)
Acceleration: 50g
Duration: 11ms
Wet and dust-laden atmospheres
The transmitter is dust and sand tight and protected against immersioneffects as defined by EN 60529 (1989) to IP 67 (IP 68 on request) or byNEMA to 4X or by JIS to C0920. IP65 with Harting Han connector.
Hazardous atmospheres
With or without output meter/integral display– COMBINED ATEX (Intrinsic safety and flameproof), FM and CSA
ZELM approval. See below detailed classifications.– COMBINED INTRINSIC SAFETY and FLAMEPROOF/EUROPE:
ATEX/ZELM approvalII 1 GD T50°C, EEx ia IIC T6 (–40°C ≤ Ta ≤+40°C)T95°C, EEx ia IIC T4 (–40°C ≤ Ta ≤+85°C)II 1/2 GD T85°C, EEx d IIC T6 (–40°C ≤ Ta ≤ +75°C)
– INTRINSIC SAFETY/EUROPE:ATEX/ZELM approvalII 1 GD T50°C, EEx ia IIC T6 (–40°C ≤ Ta ≤+40°C)T95°C, EEx ia IIC T4 (–40°C ≤ Ta ≤+85°C)
– TYPE "N"/EUROPE:ATEX/ZELM type examination (for HART)II 3 GD T50°C, EEx nL IIC T6 (–40°C ≤ Ta ≤+40°C)
T95°C, EEx nL IIC T4 (–40°C ≤ Ta ≤+85°C)– FLAMEPROOF/EUROPE:
ATEX/CESI approvalII 1/2 GD T85°C, EEx d IIC T6 (–40°C ≤ Ta ≤ +75°C)
– CANADIAN STANDARDS ASSOCIATION and FACTORY MUTUAL:– Explosionproof: Class I, Div. 1, Groups A, B, C, D– Dust ignitionproof : Class II, Div. 1, Groups E, F, G– Suitable for : Class II, Div. 2, Groups F, G; Class III, Div. 1, 2– Nonincendive: Class I, Div. 2, Groups A, B, C, D– Intrinsically safe: Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G
AEx ia IIC T6/T4, Zone 0 (FM)– STANDARDS AUSTRALIA (SAA): TS Approval
- Intrinsically safe Ex ia IIC T4/T5 (–20°C ≤ Ta ≤+80°C) only HART- No sparking Ex n IIC T4/T6 (–20°C ≤ Ta ≤+80°C) only HART- Flameproof Ex d IIC T4/T6 (–20°C ≤ Ta ≤+80°C)- Dust ignitionproof DIP A21 Ta T6 (–20°C ≤ Ta ≤+80°C)
– INTRINSIC SAFETY/CHINANEPSI approval Ex ia IIC T4-T6
– FLAMEPROOF/CHINANEPSI approval Ex d IIC T6
– GOST (Russia), GOST (Kazakistan), Inmetro (Brazil)based on ATEX
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
6
R(kΩ) =Supply voltage – min. operating voltage (VDC)–––––––––––––––––––––––––––––––––––––––
22.5
Electrical Characteristics and OptionsHART digital communication and 4 to 20mA output
Power Supply
The transmitter operates from 10.5 to 42VDC with no load and isprotected against reverse polarity connection (additional load allowsoperations over 42VDC).
For EEx ia and other intrinsically safe approval power supply mustnot exceed 30VDC.
Ripple
20mV max on a 250Ω load as per HART specifications
Load limitations
4 to 20mA and HART total loop resistance :
A minimum of 250Ω is required for HART communication.
Optional indicators
Output meter
CoMeter and Prometer LCD:
5-digit (±99999 counts) programmable with 7.6mm. high (3in),7-segment numeric characters plus sign and digital point for digitalindication of output value in percentage, current or engineer unit;
10-segment bargraph display (10% per segment) for analogindication of output in percentage;
7-digit with 6mm. high (2.3in), 14-segment alphanumericcharacters, for engineer units and configuration display
Analog : 36mm (1.4in) scale on 90°.
Integral display
LCD, 15 lines x 56 column dot matrix providing 2 lines indication as
– top: 5-digit (numeric) plus sign or 7-digit alphanumeric
– bottom: 7-digit alphanumeric
and additional 50-segment bargraph for indication of analog outputin percentage.
User-definable matrix display mode with HART communication:
– process variable in pressure unit or
– output signal as percentage, current or engineering units
Display also indicates in/out transfer function, static pressure,sensor temperature and diagnostic messages and providesconfiguration facilities.
Optional surge protection
Up to 4kV
– voltage 1.2 µs rise time / 50 µs delay time to half value
– current 8 µs rise time / 20 µs delay time to half value
Output signal
Two–wire 4 to 20mA, user-selectable for linear or square root output,power of 3/2 or 5/2, 5th order or two 2nd order switching point selectableprogrammable polynomial output.
HART® communication provides digital process variable (%, mA orengineering units) superimposed on 4 to 20mA signal, with protocolbased on Bell 202 FSK standard.
Output current limits (to NAMUR standard)
Overload condition
- Lower limit: 3.8mA
- Upper limit: 20.5mA
Transmitter failure mode (to NAMUR standard)
The output signal can be user-selected to a value of 3.7 or 22mA ongross transmitter failure condition, detected by self-diagnostics.
In case of CPU failure the output is driven <3.7mA or >22mA.
(volts)
MINIMUM OPERATING VOLTAGES
10.5
with integral display
with optional output analog indicator
with optional surge protection
with ProMeter output indicator
10.7 12.3 12.5
no link on output indicator plugs
15.3
with CoMeter indicator and HART communication
13.3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
7
PROFIBUS PA output
Device type
Pressure transmitter compliant to Profiles 3.0 Class A & B; ident.number 052B HEX.
Power supply
The transmitter operates from 9 to 32VDC , polarity independent.
For EEx ia approval power supply must not exceed 17.5VDC.Intrinsic safety installation according to FISCO model.
Current consumptionoperating (quiescent): 10.5mA
fault current limiting: 20mA max.
Output signal
Physical layer in compliance to IEC 1158–2/EN 61158–2 withtransmission to Manchester II modulation, at 31.25kbit/sec.
Output interface
PROFIBUS PA communication according to Profibus DP50170 Part 2/DIN 19245 part 1–3.
Output update time
25ms
Function blocks
2 analog input, 1 transducer, 1 physical
Integral display
LCD, 15 lines x 56 column dot matrix providing 2 lines indication as
– top: 5-digit (numeric) plus sign or 7-digit alphanumeric
– bottom: 7-digit alphanumeric
and additional 50-segment bargraph for indication of output inpercentage of the analog input function block assigned to the primaryvariable.
User-definable matrix display mode:
– process variable in pressure units or
– primary variable in engineering units (output of transducer block) or
– output as percentage or engineering units of analog input functionblocks
Display also indicates diagnostic messages and providesconfiguration facilities.Secondary variable, static pressure and sensor temperature can beread.
Transmitter failure mode
On gross transmitter failure condition, detected by self-diagnostics, theoutput signal can be driven to defined conditions, selectable by the useras safe, last valid or calculated value. If electronic failure or short circuitoccur the transmitter consumption is electronically limited at a definedvalue (20mA approx), for safety of the network.
FOUNDATION Fieldbus output
Device type
LINK MASTER DEVICE
Link Active Scheduler (LAS) capability implemented.
Power supply
The transmitter operates from 9 to 32VDC, polarity independent.
For EEx ia approval power supply must not exceed 24VDC (entitycertification) or 17.5VDC (FISCO certification), according to FF–816.
Current consumption
operating (quiescent): 10.5mA
fault current limiting: 20mA max.
Output signal
Physical layer in compliance to IEC 1158–2/EN 61158–2 withtransmission to Manchester II modulation, at 31.25kbit/sec.
Function blocks/execution period
2 enhanced Analog Input blocks/25ms max (each)1 enhanced PID block/40ms max.1 standard ARitmetic block/25ms1 standard Input Selector block/25ms1 standard Control Selector block/25ms1 standard Signal Characterization block/25ms1 standard Integrator/Totalizer block/25ms
Additional blocks
1 enhanced Resource block
1 custom Pressure with calibration transducer block
1 custom Advanced Diagnostics transducer block including Plugged Input Line Detection
1 custom Local Display transducer block
Number of link objects35
Number of VCRs
35
Output interface
FOUNDATION fieldbus digital communication protocol to standard H1,compliant to specification V. 1.6; FF registration in progress.
Integral display
LCD, 15 lines x 56 column dot matrix providing 2 lines indication as
– top: 5-digit (numeric) plus sign or 7-digit alphanumeric
– bottom: 7-digit alphanumeric
and additional 50-segment bargraph for percentage indication of theanalog input function block output, assigned to the primary variable.
User-definable matrix display mode:
– process variable in pressure units or
– primary variable in engineering units (output of transducer block) or
– output as percentage or engineering units of one or more selected function blocks
Display also indicates diagnostic messages. Secondary variable,static pressure and sensor temperature can be read.
Transmitter failure mode
The output signal is "frozen" to the last valid value on gross transmitterfailure condition, detected by self-diagnostics which also indicate aBAD conditions. If electronic failure or short circuit occur the transmitterconsumption is electronically limited at a defined value (20mA approx),for safety of the network.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
8
Operating influences
Temperature effects
per 20K (36°F) ambient temperature change on transmitter sensorbetween the limits of –20°C to +65°C (–4 to +150°F):
The total temperature error is the combination of the abovetransmitter effect with seal errors, as appliclable due to applicationtemperatures.
Refer to seal data sheet for additional effects of the remote seal.
Optional CoMeter and ProMeter ambient temperature
Total reading error per 20K (36°F) change between the ambient limitsof –20 and +70°C (-4 and +158°F) :
±0.15% of max span (16mA).
Static pressure (zero errors can be calibrated out at line pressure)
for differential measurement per 2MPa, 20bar or 290psi.
Model 264DR with remote seal(s)– zero error: ±0.25% of URL– span error: ±0.25% of readingMultiply by 1.5 the errors for sensor codes B and E and for sensor/seal combinations marked (•)
Supply voltage
Within voltage/load specified limits the total effect is less than0.005% of URL per volt.
Load
Within load/voltage specified limits the total effect is negligible.
Electromagnetic field
Total effect : less than 0.10% of span from 20 to 1000MHz and forfield strengths up to 30V/m when tested with shielded conduit andgrounding, with or without meter.
Common mode interference
No effect from 100Vrms @ 50Hz, or 50VDC
Vibration effect
±0.10% of URL (according to IEC 61298–3)
URLSpan
URLSpan
URLSpan
URLSpan
Performance specificationsStated at reference condition to IEC 60770 ambient temperature of 20°C(68°F), relative humidity of 65%, atmospheric pressure of 1013hPa(1013mbar), mounting position with vertical diaphragm and zero basedrange for transmitter with isolating diaphragms in AISI 316 L ss or Hastelloyand silicone oil fill and HART digital trim values equal to 4–20mA span endpoints, in linear mode.
Unless otherwise specified, errors are quoted as % of span.
Some performance data are affected by the actual turndown (TD) as ratiobetween Upper Range Limit (URL) and calibrated span.
IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODEPROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TOOPTIMIZE PERFORMANCE CHARACTERISTICS.
Accuracy rating% of calibrated span, including combined effects of terminal basedlinearity, hysteresis and repeatability.
For fieldbus versions SPAN refer to analog input function block outscalerange
Using remote seal sizes <DN 80/3in– ±0.10% for TD from 1:1 to 10:1
(±0.10% for sensor codes B and E for TD from 1:1 to 5:1)
– ±0.01% x for TD from 10:1 to 20:1
±0.02% x for sensor codes B and Efor TD from 5:1 to 10:1)
Using remote seal sizes ≥ DN 80/3in– ±0.075% for TD from 1:1 to 10:1
( ±0.10% for sensor codes B and E for TD from 1:1 to 5:1)
– ±0.0075% x for TD from 10:1 to 20:1
(±0.02% x for sensor codes B and Efor TD from 5:1 to 10:1)
Multiply the values by 1.5 for sensor/seal combination marked (•) and fortransmitter for absolute measurement.
ledoMrosneS
edoCDTrofotpu
RD462RP462
SotE 1:01 )naps%560.0+LRU%40.0(±
B 1:5 )naps%01.0+LRU%60.0(±
RV462 SotE 1:01 )naps%31.0+LRU%80.0(±
RN/RH462 SotG 1:01 )naps%560.0+LRU%40.0(±
RH462 V 1:01 )naps%01.0+LRU%60.0(±
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
9
Physical Specification(Refer to ordering information sheets for variant availability related tospecific model or versions code)
Materials
Model 264DR only – Side without seal
Process isolating diaphragms (*)
AISI 316 L ss; Hastelloy C276™; Monel 400™; Tantalum;
Hastelloy C276™ on AISI 316 L ss gasket seat.
A remote seal can be selected with required diaphragm (refer below)
Process flanges, adapters, plugs and drain/vent valves (*)
AISI 316 L ss; Hastelloy C276™; Monel 400™.
Bolts and nuts
AISI 316 ss bolts Class A4–80 and nuts Class A4-70 per UNI 7323(ISO 3506);
AISI 316 ss bolts and nuts Class A4–50 per UNI 7323 (ISO 3506), incompliance with NACE MR0175 Class II.
Gaskets (*)
Viton™; PTFE.
Models 264DR/PR/VR/HR/NR
Blind flange (reference and/or remote seal(s) side)
AISI 316 L ss
Seal side process diaphragm (remote seal) (*)
AISI 316 L ss; Hastelloy C276™ ; Tantalum;AISI 316 L ss or Hastelloy C276™ with anti-stick coating;AISI 316 L ss with anti-corrosion coating; AISI 316 L ss gold plated;Superduplex ss (UNS S32750 to ASTM SA479);Diaflex (AISI with anti-abrasion treatment).
Extension material
AISI 316 L ss (also for Diaflex and gold plated diaphragms);Hastelloy C276™;AISI 316 L ss or Hastelloy C276™ with coating same as diaphragm
Seal side fill fluid (remote seal)
Silicone oil-DC200™, Silicone oil-AN140™, Inert-Halocarbon™4.2,Inert-Galden™, Silicone Polymer-Syltherm XTL™, Vegetable oil-Neobee M-20™, Glycerin Water, Mineral oil-MARCOL 82™, ABB fill.
Sensor fill fluid
Silicone oil (DC200™); inert fill (Halocarbon™4.2 or Galden™).
Sensor housing
AISI 316 L ss.
Electronic housing and covers
Barrel version
– Copper-free content aluminium alloy with baked epoxy finish;
– Low-copper content aluminium alloy with baked epoxy finish;
– AISI 316 L ss.
DIN version
– Low-copper content aluminium alloy with baked epoxy finish.
Covers O-ring
Buna N.
Local zero and span adjustments:
Glass filled polycarbonate plastic (removable).
Tagging
AISI 316ss data plate attached to the electronics housing.
CalibrationStandard: at maximum span, zero based range, ambient temperatureand pressure;
Optional: at specified range and ambient conditions;.
Optional extras
Output indicator
plug-in rotatable type, LCD or analog.
Supplemental customer tag
AISI 316 ss tag screwed/fastened to the transmitter for customer's tagdata up to a maximum of 20 characters and spaces on one line for tagnumber and tag name, and up to a maximum of 3 spaced strings of 10characters each for calibration details (lower and upper values plusunit). Special typing evaluated on request for charges.
Surge protection (only as external unit for PROFIBUS PA and FF)
Test Certificates (test, design, calibration, material traceability)
Tag and manual language
Communication connectors
Process connectionson conventional flanges : 1/4 – 18 NPT on process axis
on adapters : 1/2 – 14 NPT on process axis
fixing threads: 7/16 – 20 UNF at 41.3mm centre distance
Refer to seal data sheet for process connection variants throughremote seal.
Electrical connectionsTwo 1/2 – 14 NPT or M20x1.5 or PG 13.5 or 1/2 GK threadedconduit entries, direct on housing.
Special communication connector (on request)
– HART : straight or angle Harting Han connector and one plug.
– FOUNDATION Fieldbus, PROFIBUS PA: M12x1 or 7/8.
Terminal block
HART version: three terminals for signal/external meter wiring up to2.5mm2 (14AWG) and three connection points for test andcommunication purposes.
Fieldbus versions: two terminals for signal wiring (bus connection)up to 2.5mm2 (14AWG)
Grounding
Internal and external 6mm2 (10AWG) ground termination points areprovided.
Mounting positionTransmitter can be mounted in any position.Electronics housing may be rotated to any position. A positive stopprevents over travel.
Mass (without options and seals)– models 264DR/PR/VR : 3kg approx (7lb)
– models 264HR/NR: 1.7kg approx (4lb)
Add 1.5kg (3.4lb) for AISI housing.Add 650g (1.5lb) for packing.
PackingCarton
(*) Wetted parts of the transmitter.
(**) U-bolt material: AISI 400 ss; screws material: high-strength alloy steel orAISI 316 ss.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
10
ConfigurationTransmitter with HART communication and 4 to 20 mA
Standard configuration
Transmitters are factory calibrated to customer's specified range.Calibrated range and tag number are stamped on the tag plate. If acalibration range and tag data are not specified, the transmitter will besupplied with the plate left blank and configured as follows:
Engineering Unit kPa4 mA Zero20 mA Upper Range Limit (URL)Output LinearDamping 1 sec.Transmitter failure mode UpscaleSoftware tag (8 characters max) BlankOptional LCD indicator/display 0 to 100.0% linear
Any or all the above configurable parameters, including Lower range–valueand Upper range-value which must be the same unit of measure, can beeasily changed using the HART hand–held communicator or by a PCrunning the configuration software SMART VISION with DTM for 2600T.The transmitter database is customized with specified flange type andmaterial, O–ring and drain/vent materials and meter code option.Custom configuration (option)The following data may be specified in addition to the standardconfiguration parameters:
Descriptor 16 alphanumeric charactersMessage 32 alphanumeric charactersDate Day, month, year
Transmitter with PROFIBUS PA communicationTransmitters are factory calibrated to customer's specified range.Calibrated range and tag number are stamped on the tag plate. If acalibration range and tag data are not specified, the transmitter will besupplied with the plate left blank and configured as follows:
Measure Profile PressureEngineering Unit kPaOutput scale 0% Lower Range Limit (LRL)Output scale 100% Upper Range Limit (URL)Output LinearHi-Hi Limit Upper Range Limit (URL)Hi Limit Upper Range Limit (URL)Low Limit Lower Range Limit (LRL)Low-Low Limit Lower Range Limit (LRL)Limits hysteresis 0.5% of output scalePV filter 0 sec.Address (settable by local key) 126Tag 32 alphanumeric characters
Any or all the above configurable parameters, including Lower range-valueand Upper range–value which must be the same unit of measure, can beeasily changed by a PC running the configuration software SMART VISIONwith DTM for 2600T.The transmitter database is customized with specified flange type andmaterial, O–ring and drain/vent materials and meter code option.Custom configuration (option)The following data may be specified in addition to the standardconfiguration parameters:
Descriptor 32 alphanumeric charactersMessage 32 alphanumeric charactersDate Day, month, year
Transmitter with FOUNDATION FieldbuscommunicationTransmitters are factory calibrated to customer's specified range.Calibrated range and tag number are stamped on the tag plate. If acalibration range and tag data are not specified, the transmitter will besupplied with the plate left blank and the analog input function block FB1is configured as follows:
Measure Profile PressureEngineering Unit kPaOutput scale 0% Lower Range Limit (LRL)Output scale 100% Upper Range Limit (URL)Output LinearHi-Hi Limit Upper Range Limit (URL)Hi Limit : Upper Range Limit (URL)Low Limit Lower Range Limit (LRL)Low-Low Limit Lower Range Limit (LRL)Limits hysteresis 0.5% of output scalePV filter time 0 sec.Tag 32 alphanumeric characters
The analog input function block FB2 is configured for the sensor tempe-rature measured in °C. Any or all the above configurable parameters,including the range values, can be changed using any host compliant toFOUNDATION fieldbus. The transmitter database is customized withspecified flange type and material, O–ring and drain/vent materials andmeter code option.
For any protocol available engineering units of pressure measure are :Pa, kPa, MPainH2O@4°C, mmH2O@4°C, psiinH2O@20°C, ftH2O@20°C, mmH2O@20°CinHg, mmHg, Torrg/cm2, kg/cm2, atmmbar, bar
™ Hastelloy is a Cabot Corporation trademark
™ Monel is an International Nickel Co. trademark
™ Viton is a Dupont de Nemour trademark
™ DC200 is a Dow Corning Corporation trademark
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
™ AN140 is a Wacker-Chemie trademarl
™ Neobee M20 is a Stepan Company trademark
™ Marcol is a Esso Italiana trademarl
™ Syltherm is a Dow Chemical Company trademark
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
11
54 (2.13)
62 (2.44) 43 (1.69)
135
(5.3
1)
+
82 (3
.23)
127 (5.00)17 (0.67)
26 (1.02)17 (0.67)
36 (1.42)
MOUNTING DIMENSIONS (not for construction unless certified) - dimensions in mm (in)264DR/PR/VR transmitter on bracket for vertical or horizontal 60mm (2in) pipe mounting (barrel housing)
Consider one capillary only to remote seal for 264PR/VR
Certificationlabel
Identification tagAdjustments
Terminalside
Electronicside
Integral displayhousing
Min. clearanceto removethe cover
Output meterhousing
Barrel typehousing
Electricalconnections
Coverlockingscrew
Note : For 264DR side with 1/4 – 18 NPT thread director with 1/2 – 14 NPT through adapter, threaded process connection, gasketgroove and gaskets are in accordance with DIN 19213.Bolting threads for fixing adapter or other devices (i.e. manifod etc.) on process flange is 7/16 – 20 UNF.
Flange
To remoteseal
43 (1.69 71 (2.80)
54 (2.13)
135
(5.3
1)
+
82 (3
.23)
127 (5.00)17 (0.67)
26 (1.02)17 (0.67)
36 (1.42)
166
(6.5
4)
38 (1.50) 51 (2.01)41
.3 (1
.63)
63 (2
.48)
55 (2.17)
S
NOSSTIUCRIC
SEL
NOI
NETS
OST U
RREV
UOCE
LRE
DRAG
TNE' M
EF NE BELCI
QUAT
E
ALSTIU
CRIC
IVE
H
COPE
EK
VERTIGT
E
H
WN
!
86 (3.39)
70 (2.75)
70 (2
.75)
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
12
264DR/PR/VR transmitter on bracket for vertical or horizontal 60mm (2in) pipe mounting (DIN housing)
Electricalconnections
17 (0.67)
41.3 (1.63)
63 (2.48)
179 (7.05)
38 (1
.50)
51 (2
.01)
55 (2
.17)
148 (5.83)36 (1.42)
26 (1
.02)
17 (0
.67)
82 (3.23)
102
(4.0
2)
82 (3.23)
S
NOS
STIUCRI C SEL
NOINET
SOS
TU
RRE
VUOC
ELRED
RAG
TNE'
MEF
NEBEL
CI
QUAT
E
ALSTI UCRI C
IVE
H
COPE
EK
VER
TIGT
E
H
WN
!
264DR/PR/VR transmitter on bracket for vertical or horizontal 60mm (2in) pipe mounting
Cover lockingscrew
Certificationlabel
Identificationtag
To remoteseal
DIN typehousing
Terminal side
Externalground
Flange
Electronicside
Certificationlabel
Adjustments
Output meterhousing
Consider one capillary only to remote seal for 264PR/VR
55 (2.17) max 7 (0.28)
142
(5.5
9)
86 (3.39)
S
NOSSTIUCRIC
SEL
NOI
NETS
OST U
RREV
UOCE
LRE
DRAG
TNE' M
EF NE BELCI
QUAT
E
ALSTIUCRI
C
IVE
H
COPE
EK
VERTIGT
E
H
WN
!
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
13
70 (2
.75)
S
NOS
STIUCRI C SEL
NOINET
SOS
TU
RRE
VUOC
ELRED
RAG
TNE'
MEF
NEBEL
CI
QUAT
E
ALSTI UCRI C
IVE
H
COPE
EK
VER
TIGT
E
H
WN
!
264DR/PR/VR transmitter on bracket for wall mounting (by up to four M8 screws; NOT SUPPLIED)
264DR/PR/VR transmitter on flat type (for box) bracket for vertical or horizontal 60mm (2in) pipe mounting
70 (2
.75)
70 (2.75)
25 (1
)
Consider one capillary only to remote seal for 264PR/VR
204
(8.0
3)
70 (2.75)
84 (3
.31)
70 (2
.75)
98 (3.86)
+
25 (0.98)
47 (1.85)
S
NOSSTIUCRIC
SEL
NOI
NETS
OST U
RREV
UOCE
LRE
DRAG
TNE' M
EF NE BELCI
QUAT
E
ALSTIU
CRIC
IVE
H
COPE
EK
VERTIGT
E
H
WN
!
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
14
18 (0
.71)
ø 65 (2.56)
135 (5.31)
16 (0
63)
13 (0
.51)
40 (1
.57)
100
(3.9
4)
127 (5.00)17 (0.67)
26 (1.02)17 (0.67)
36 (1.42)
Electricalconnections
Cover lockingscrew
To remoteseal
Min. Bend Radius150 (6)
264HR/NR transmitter on bracket for 60mm (2in) pipe mounting (barrel housing)
Sensors G, H, M, P, Q, S
264HR transmitter on bracket for 60mm (2in) pipe mounting (barrel housing)
Sensor V
100
(3.9
4)
56 (2.20)
135 (5.31)
46 (1
.81)
127 (5.00)
17 (0.67)26 (1.02)
17 (0.67)36 (1.42)
40 (1
.57)
86 (3.39)
S
NOSSTIUCRIC
SEL
NOI
NETS
OST U
RREV
UOCE
LRE
DRAG
TNE' M
EF NE BELCI
QUAT
E
ALSTIUCRI
C
IVE
H
COPE
EK
VERTIGT
E
H
WN
!Electrical
connections
Cover lockingscrew
Min. Bend Radius150 (6)
To remoteseal
170
(6.6
9)
S
NOSSTIUCRIC
SEL
NOI
NETS
OST U
RREV
UOCE
LRE
DRAG
TNE' M
EF NE BELCI
QUAT
E
ALSTIUCRI
C
IVE
H
COPE
EK
VERTIGT
E
H
WN
!
86 (3.39)
70 (2.75)
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
15
Electrical connectionsHART Version
FIELDBUS Versions
+
+
-
-
++
--691HT
A B C
1
D E F
2
G H I
3
J K L
4
M N O
5
P Q R
6
S T U
7
V W X
8
Y Z #
9
@ % & /
0
+-
PV
REVIEW SERIALLINK
TRIM
F1 F2 F3 F4
CONF
M
Kent-Taylor
0
43
56 7 8
9
1020
40
0
60
100%
2 80
M+
-
- 1
54 6
23 8
7
+
TEST COMM
Internal groundtermination point
Fieldbus line(polarity independent)
External groundtermination point
Test points4 to 20mA
Hartingpin (male)
identification
Internal groundtermination point
External groundtermination point
Hand-heldcommunicator
GND
Line load
Remoteindicator
Powersource
250 ohm min
Receiver
HART hand-held communicator may be connected at any wiring termination point in the loop, providing the minimum resistanceis 250 ohm. If this is less than 250 ohm, additional resistance should be added to allow communications
Optional
BUS CONNECTIONS
2
1
4
3
1 3
42
7/8” connector
M12 x 1 connector
NOITACIFITNEDI)elam(NIPNOITADNUOF
subdleiFSUBIFORP
AP11111222223333344444
-FF+FF
DLEIHSDNUORG
+APDNUORG
–APDLEIHS
CONNECTOR IS SUPPLIED LOOSE WITHOUT MATING FEMALE PLUG
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
16
BASIC ORDERING INFORMATION model 264DR Differential Pressure Transmitter with remoteseal(s)Select one character or set of characters from each category and specify complete catalog number.Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required.Quote separately one or two seals as required.
LEDOMESAB 1– ts 5ot ht sretcarahc 2 6 4 D R X S X X X d'tnoC
%570.0YCARUCCAESAB–)s(laesetomerhtiwrettimsnarTerusserPlaitnereffiD
–stimilnapS-ROSNES 6 ht retcarahcaPk4dna2.0
aPk61dna45.0aPk04dna76.0
aPk56dna1.1aPk061dna76.2
aPk006dna01aPk0042dna04
aPk0008dna431aPk00061dna762
rabm04dna2rabm061dna4.5rabm004dna7.6rabm056dna11
rabm0061dna7.62rab6dna1.0
rab42dna4.0rab08dna43.1
rab061dna76.2
Hni61dna8.0 2OHni46dna61.2 2OHni061dna76.2 2OHni062dna53.4 2OHni246dna7.01 2Oisp78dna54.1isp843dna8.5
isp0611dna4.91isp0232dna7.83
BEFGHMPQS
edocesU 7– ht retcarahc S
)strapdettew(diulflliF/lairetammgarhpaiD 8– ht retcarahc
ssL613ISIA)taesISIAno(™672CyolletsaH
™672CyolletsaH™004lenoM
mulatnaTssL613ISIA
)taesISIAno(™672CyolletsaH™672CyolletsaH
™004lenoMmulatnaT
ssL613ISIA)taesISIAno(™672CyolletsaH
™672CyolletsaH™004lenoM
mulatnaTssL613ISIAssL613ISIAssL613ISIA
lioenociliSlioenociliSlioenociliSlioenociliSlioenociliS
nedlaG-diulftrenInedlaG-diulftrenInedlaG-diulftrenInedlaG-diulftrenInedlaG-diulftrenI
nobracolaH-diulftrenInobracolaH-diulftrenInobracolaH-diulftrenInobracolaH-diulftrenInobracolaH-diulftrenI
lioenociliSnedlaG-diulftrenI
nobracolaH-diulftrenI
)yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotslaesowt()yletarapesdetouqebotslaesowt()yletarapesdetouqebotslaesowt(
)3etoN()3etoN()3etoN()3etoN()3etoN(
)3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN()3,1setoN(
)2etoN()3,1setoN()3,1setoN(
ECANECANECANECAN
ECANECANECANECAN
ECANECANECANECAN
SHKMTABFCDLQP45R2W
)strapdettew(noitcennocdnalairetamsretpada/segnalfssecorP – 9 ht retcarahc
noitcurtsnocslaesowtrofssL613ISIA)noitcennoclatnoziroH(ssL613ISIA)noitcennoclatnoziroH(ssL613ISIA
1/4 (tceridf-TPN81– 7/ 61 )gnillird.S.UFNU02–1/2 (retpadahguorhtf-TPN41– 7/ 61 )gnillird.S.UFNU02–1/4 (tceridf-TPN81– 7/ 61 )gnillird.S.UFNU02–1/2 (retpadahguorhtf-TPN41– 7/ 61 )gnillird.S.UFNU02–1/4 (tceridf-TPN81– 7/ 61 )gnillird.S.UFNU02–1/2 (retpadahguorhtf-TPN41– 7/ 61 )gnillird.S.UFNU02–
)4etoN()5etoN()5etoN(
)6,5setoN()6,5setoN()6,5setoN()6,5setoN(
ECANECANECANECANECANECANECAN
RAB
)noitcennoclatnoziroH(™672CyolletsaH)noitcennoclatnoziroH(™672CyolletsaH
DE
)noitcennoclatnoziroH(™004lenoM)noitcennoclatnoziroH(™004lenoM
GH
)strapdettew(teksaG/stloB 01– ht retcarahc
noitcurtsnocslaesowtrofsteksagtuohtiw)ECAN(ss613ISIAnoitcurtsnocslaesowtrofsteksagtuohtiwss613ISIA
ss613ISIAss613ISIA
)ECAN(ss613ISIA)ECAN(ss613ISIA
™notiVEFTP™notiV
EFTP
)4etoN()4etoN()5etoN(
)5,1setoN()5etoN(
)5,1setoN(
ECAN
ECANECAN
RS1234
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
17
RD462NOITAMROFNIGNIREDROCISAB X X
noitcennoclacirtcelednalairetamgnisuoH 11– ht retcarahc
)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg(
)7etoN()7etoN(
)7etoN()7etoN(
)7etoN(
)7etoN(
ABDCEG
)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
HLNMPR
)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocsubdleiF
STVUZ
)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA
)02MC(5.1x02M5.31gP
rotcennocnaHgnitraH
JYK
snoitpolanoitiddA/tuptuO 21– ht retcarahc
Am02ot4dnanoitacinummoclatigidTRAHAm02ot4dnanoitacinummoclatigidTRAH
APSUBIFORPAPSUBIFORP
subdleiFNOITADNUOFsubdleiFNOITADNUOF
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
)9,8setoN()8etoN(
)9,8setoN()9etoN(
)9,8setoN()9etoN(
H1P2F3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
18
ADDITIONAL ORDERING INFORMATION for model 264DRAdd one or more 2-digit code(s) after the basic ordering information to select all required options
XX XX XX XX XX XX XX XX XX d'tnoC
)strapdettew()noitisopdnalairetam(evlavtnev/niarDssL613ISIAssL613ISIAssL613ISIA
™672CyolletsaH™672CyolletsaH™672CyolletsaH
™004lenoM™004lenoM™004lenoM
sixassecorpnopotedisegnalfno
mottobedisegnalfnosixassecorpno
potedisegnalfnomottobedisegnalfno
sixassecorpnopotedisegnalfno
mottobedisegnalfno
)01etoN()01etoN()01etoN()11etoN()11etoN()11etoN()21etoN()21etoN()21etoN(
ECANECANECANECANECANECANECANECANECAN
1V2V3V4V5V6V7V8V9V
noitacifitreclacirtcelEaixEEytefaScisnirtnI–DG1yrogetaCIIpuorGXETA
dxEEfoorpemalF–DG2/1yrogetaCIIpuorGXETA)31etoN(ecnailpmocngisedLnxEE"N"noitcetorpfoepyT–DG3yrogetaCIIpuorGXETA
ylno()ASC(noitaicossAdradnatSnaidanaC 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–)subdleiFNOITADNUOFdnaAPSUBIFORProfnxEdnaaixEtoN(AASailartsuAsdradnatS
htiwylno(lavorppa)MF(lautuMyrotcaF 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–foorpemalFdnaytefaScisnirtnI-XETAdenibmoC
htiwylno(ASCdnaMF,XETAdenibmoC 1/2 )31etoN()noitcennoclacirtcele5.31gPdna02M,TPN41–)3edoctuptuOFFrofelbaliavatoN(aixEytefaScisnirtnI-)anihC(ISPEN
dxEfoorpemalF-)anihC(ISPENaixEE)aissuR(TSOGdxEE)aissuR(TSOG
aixEE)natsikazaK(TSOGdxEE)natsikazaK(TSOG
)31etoN(aixEE)lizarB(ortemnI)31etoN(dxEE)lizarB(ortemnI)31etoN(LnxEE)lizarB(ortemnI
1E2E3E4E5E6E7ENEYEZE1W2W3W4W5W6W7W
retemtuptuO
noitarbilacdradnatS,reteMorPnoitarbilaclaicepS,reteMorP
elacs%001–0raenilrotacidnituptuogolanAelacs01–0toorerauqsrotacidnituptuogolanA
)elacsraenilrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA)elacstoorerauqsrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA
)reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP)noitarugifnocremotsuc–reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP
)31etoN()31etoN()31etoN()31etoN()31etoN()31etoN()31etoN()31etoN(
1D2D3D4D5D6D7D8D
DCLlargetnIyalpsidlargetniDCLlatigiD 1L
)lairetamdnaepahs(tekcarbgnitnuoMgnitnuomepiproFgnitnuomepiproFgnitnuomllawroFgnitnuomllawroF
xobrofepyttalF
)gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN(
leetsnobraCssL613ISIAleetsnobraCssL613ISIAssL613ISIA
1B2B3B4B5B
egruS)Am02-4/TRAHroflanretnI(rotcetorPtneisnarT/egruS
ylnosubdleiFNOITADNUOFdnaAPSUBIFORProfesooldeilppuslanretxE(rotcetorPtneisnarT/egruShtiwelbatius 1/2 )TSUDon,snoitacifitrecASCdnaMF,XETAhtiwdnanoitcennoclacirtcele02MdnaTPN41–
1S
launamgnitarepOnamreG
nailatIhcnerF
1M2M4M
egaugnalgat&slebaLnamreG
nailatIhcnerF
1T2T4T
etalpgatlanoitiddAetalpleetssselniatsnogatfognitnirpresaL 2I
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
19
Note 1: Suitable for oxygen service
Note 2: Not wetted – Hastelloy C276™ on AISI seat for sensor code B
Note 3: Not wetted – Not available with sensor code B
Note 4: Not available with diaphragm/fill code S, H, K, M, T, A, B, F, C, D, L, Q, P, 4, 5
Note 5: Not available with diaphragm/fill code R, 2, W.
Note 6: Not available with diaphragm material/fill fluid code S, H, A, B, L, Q
Note 7: Select type in additional ordering code
Note 8: Not available with Electronic Housing code Z, R, G
Note 9: Not available with Electronic Housing code P, E and K
Note 10: Not available with Process flanges/adapters code D, E, G, H, R
Note 11: Not available with Process flanges/adapters code A, B, G, H, R
Note 12: Not available with Process flanges/adapters code A, B, D, E, R
Note 13: Not available with PROFIBUS PA and FF output code 2 or 3
Note 14: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y
™ Hastelloy is a Cabot Corporation trademark
™ Monel is an International Nickel Co. trademark
™ Viton is a Dupont de Nemour trademark
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
Standard delivery items (can be differently specified by additional ordering code)– Adapters supplied loose
– Plug on axis (no drain/vent valves)
– General purpose (no electrical certification)
– No meter/display, no mounting bracket, no surge protection
– English manual and labels
– Configuration with kPa and deg. C units
– No test, inspection or material traceability certificates
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'SRESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
XX XX XX XX
noitarugifnoCHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°4taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°4taisp/O
motsuC
2N3N4N5N6N
setacifitreC
)tniop-9(noitarbilacfo1.3–40201NEetacifitrecnoitcepsnIngisedtnemurtsnifo1.2–40201NEredroehthtiwecnailpmocfoetacifitreC
1C6C
ytilibaecartlairetaM
strapdettewssecorpfo1.2–40201NEredroehthtiwecnailpmocfoetacifitreCstrapdettewssecorpfo1.3–40201NEetacifitrecnoitcepsnI
1H3H
rotcennoC
)gulpelamefgnitamtuohtiwesooldeilppus(-)subdleiFNOITADNUOFrofdednemmoceR(8/7subdleiF)gulpelamefgnitamtuohtiwesooldeilppus(-)APSUBIFORProfdednemmoceR(1x21MsubdleiF
yrtnethgiarts–naHgnitraHyrtneelgna–naHgnitraH
)41,9setoN()41,9setoN()41,8setoN()41,8setoN(
1U2U3U4U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
20
BASIC ORDERING INFORMATION model 264PR Gauge Pressure Transmitter with remote sealSelect one character or set of characters from each category and specify complete catalog number.Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required.
LEDOMESAB 1– ts 5ot ht sretcarahc 2 6 4 P R X S X X X X X
%570.0YCARUCCAESAB–laesetomerhtiwrettimsnarTerusserPeguaG
–stimilnapS-ROSNES 6 ht retcarahcaPk61dna45.0aPk04dna76.0
aPk56dna1.1aPk061dna76.2
aPk006dna01aPk0042dna04
aPk0008dna431aPk00061dna762
rabm061dna4.5rabm004dna7.6rabm056dna11
rabm0061dna7.62rab6dna1.0
rab42dna4.0rab08dna43.1
rab061dna76.2
Hni46dna61.2 2OHni061dna76.2 2OHni062dna53.4 2OHni246dna7.01 2Oisp78dna54.1isp843dna8.5
isp0611dna4.91isp0232dna7.83
EFGHMPQS
edocesU 7– ht retcarahc S
diulflliF/lairetammgarhpaiD 8– ht retcarahc
ssL613ISIAssL613ISIAssL613ISIA
lioenociliSnedlaG-diulftrenI
nobracolaH-diulftrenI
)yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaeseno(
)1etoN()1etoN(
R2W
lairetamsretpada/segnalfssecorP – 9 ht retcarahc
noitcurtsnoclaesrofssL613ISIA R
stloB 01– ht retcarahc
noitcurtsnoclaesrofsteksagtuohtiw)ECAN(ss613ISIAnoitcurtsnoclaesrofsteksagtuohtiwss613ISIA
ECAN RS
noitcennoclacirtcelednalairetamgnisuoH 11– ht retcarahc
)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA
)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA
)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocsubdleiF)02MC(5.1x02M
5.31gProtcennocnaHgnitraH
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg(
)2etoN()2etoN(
)2etoN()2etoN(
)2etoN(
)2etoN(
ABDCEGHLNMPRSTVUZJYK
snoitpolanoitiddA/tuptuO 21– ht retcarahc
Am02ot4dnanoitacinummoclatigidTRAHAm02ot4dnanoitacinummoclatigidTRAH
APSUBIFORPAPSUBIFORP
subdleiFNOITADNUOFsubdleiFNOITADNUOF
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
)4,3setoN()3etoN(
)4,3setoN()4etoN(
)4,3setoN()4etoN(
H1P2F3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
21
ADDITIONAL ORDERING INFORMATION for model 264PRAdd one or more 2-digit code(s) after the basic ordering information to select all required options
XX XX XX XX XX XX XX XX XX XX XX XXnoitacifitreclacirtcelE
aixEEytefaScisnirtnI–DG1yrogetaCIIpuorGXETAdxEEfoorpemalF–DG2/1yrogetaCIIpuorGXETA
)5etoN(ecnailpmocngisedLnxEE"N"noitcetorpfoepyT–DG3yrogetaCIIpuorGXETAylno()ASC(noitaicossAdradnatSnaidanaC 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–
)subdleiFNOITADNUOFdnaAPSUBIFORProfnxEdnaaixEtoN(AASailartsuAsdradnatShtiwylno(lavorppa)MF(lautuMyrotcaF 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–
foorpemalFdnaytefaScisnirtnI-XETAdenibmoChtiwylno(ASCdnaMF,XETAdenibmoC 1/2 )5etoN()noitcennoclacirtcele5.31gPdna02M,TPN41–
)3edoctuptuOFFrofelbaliavatoN(aixEytefaScisnirtnI-)anihC(ISPENdxEfoorpemalF-)anihC(ISPEN
aixEE)aissuR(TSOGdxEE)aissuR(TSOG
aixEE)natsikazaK(TSOGdxEE)natsikazaK(TSOG
)5etoN(aixEE)lizarB(ortemnI)5etoN(dxEE)lizarB(ortemnI)5etoN(LnxEE)lizarB(ortemnI
1E2E3E4E5E6E7ENEYEZE1W2W3W4W5W6W7W
retemtuptuO
noitarbilacdradnatS,reteMorPnoitarbilaclaicepS,reteMorP
elacs%001–0raenilrotacidnituptuogolanA)elacsraenilrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA
)reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP)noitarugifnocremotsuc–reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP
)5etoN()5etoN()5etoN()5etoN()5etoN()5etoN(
1D2D3D5D7D8D
DCLlargetnIyalpsidlargetniDCLlatigiD 1L
)lairetamdnaepahs(tekcarbgnitnuoMgnitnuomepiproFgnitnuomepiproFgnitnuomllawroFgnitnuomllawroF
xobrofepyttalF
)gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN(
leetsnobraCssL613ISIAleetsnobraCssL613ISIAssL613ISIA
1B2B3B4B5B
egruS)Am02-4/TRAHroflanretnI(rotcetorPtneisnarT/egruS
ylnosubdleiFNOITADNUOFdnaAPSUBIFORProfesooldeilppuslanretxE(rotcetorPtneisnarT/egruShtiwelbatius 1/2 )TSUDon,snoitacifitrecASCdnaMF,XETAhtiwdnanoitcennoclacirtcele02MdnaTPN41–
1S
launamgnitarepOnamreG
nailatIhcnerF
1M2M4M
egaugnalgat&slebaLnamreG
nailatIhcnerF
1T2T4T
etalpgatlanoitiddAetalpleetssselniatsnogatfognitnirpresaL 2I
noitarugifnoCHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°4taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°4taisp/O
motsuC
2N3N4N5N6N
setacifitreC
)tniop-9(noitarbilacfo1.3–40201NEetacifitrecnoitcepsnIngisedtnemurtsnifo1.2–40201NEredroehthtiwecnailpmocfoetacifitreC
1C6C
ytilibaecartlairetaM
strapdettewssecorpfo1.2–40201NEredroehthtiwecnailpmocfoetacifitreCstrapdettewssecorpfo1.3–40201NEetacifitrecnoitcepsnI
1H3H
rotcennoC
)gulpelamefgnitamtuohtiwesooldeilppus(-)subdleiFNOITADNUOFrofdednemmoceR(8/7subdleiF)gulpelamefgnitamtuohtiwesooldeilppus(-)APSUBIFORProfdednemmoceR(1x21MsubdleiF
yrtnethgiarts–naHgnitraHyrtneelgna–naHgnitraH
)6,4setoN()6,4setoN()6,3setoN()6,3setoN(
1U2U3U4U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
22
Note 1: Suitable for oxygen service
Note 2: Select type in additional ordering code
Note 3: Not available with Electronic Housing code Z, R, G
Note 4: Not available with Electronic Housing code P, E and K
Note 5: Not available with PROFIBUS PA and FF output code 2 or 3
Note 6: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
Standard delivery items (can be differently specified by additional ordering code)– General purpose (no electrical certification)
– No meter/display, no mounting bracket, no surge protection
– English manual and labels
– Configuration with kPa and deg. C units
– No test, inspection or material traceability certificates
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'SRESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
23
BASIC ORDERING INFORMATION model 264HR Gauge Pressure Transmitter with remote seal
Select one character or set of characters from each category and specify complete catalog number.Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required.
LEDOMESAB 1– ts 5ot ht sretcarahc 2 6 4 H R X X X X X
%570.0YCARUCCAESAB–laesetomerhtiwrettimsnarTerusserPeguaG
–stimilnapS-ROSNES 6 ht retcarahcaPk56dna1.1
aPk061dna76.2aPk006dna01
aPk0042dna04aPk0008dna431
aPk00061dna762aPk00006dna0002
rabm056dna11rabm0061dna7.62
rab6dna1.0rab42dna4.0
rab08dna43.1rab061dna76.2
rab006dna02
Hni062dna53.4 2OHni246dna7.01 2Oisp78dna54.1isp843dna8.5
isp0611dna4.91isp0232dna7.83isp0078dna092
GHMPQSV
diulflliF/lairetammgarhpaiD 7– ht retcarahc)Vrosnesrof672CyolletsaH(ssL613ISIA
ssL613ISIAssL613ISIA
lioenociliSnedlaG-diulftrenI
nobracolaH-diulftrenI)1etoN()1etoN(
R2W
noitcennocssecorP – 8 ht retcarahc
)epytnottubtpecxe(laesetomeRlaesetomerepytnottuB
)yletarapesdetouqebotlaeseno()yletarapesdetouqebotlaesnottubeno( )2etoN(
RG
noitcennoclacirtcelednalairetamgnisuoH 9– ht retcarahc
)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg(
)3etoN()3etoN(
)3etoN()3etoN(
)3etoN(
ABDCEG
)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
HLNMPR
)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocsubdleiF
STVUZ
snoitpolanoitiddA/tuptuO 01– ht retcarahc
Am02ot4dnanoitacinummoclatigidTRAHAm02ot4dnanoitacinummoclatigidTRAH
APSUBIFORPAPSUBIFORP
subdleiFNOITADNUOFsubdleiFNOITADNUOF
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
)5,4setoN()4etoN(
)5,4setoN()5etoN(
)5,4setoN()5etoN(
H1P2F3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
24
ADDITIONAL ORDERING INFORMATION for model 264HRAdd one or more 2-digit code(s) after the basic ordering information to select all required options
XX XX XX XX XX XX XX XX XX XX XX XX
noitacifitreclacirtcelEaixEEytefaScisnirtnI–DG1yrogetaCIIpuorGXETA
dxEEfoorpemalF–DG2/1yrogetaCIIpuorGXETA)6etoN(ecnailpmocngisedLnxEE"N"noitcetorpfoepyT–DG3yrogetaCIIpuorGXETA
ylno()ASC(noitaicossAdradnatSnaidanaC 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–)subdleiFNOITADNUOFdnaAPSUBIFORProfnxEdnaaixEtoN(AASailartsuAsdradnatS
htiwylno(lavorppa)MF(lautuMyrotcaF 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–foorpemalFdnaytefaScisnirtnI-XETAdenibmoC
htiwylno(ASCdnaMF,XETAdenibmoC 1/2 )6etoN()noitcennoclacirtcele5.31gPdna02M,TPN41–)3edoctuptuOFFrofelbaliavatoN(aixEytefaScisnirtnI-)anihC(ISPEN
dxEfoorpemalF-)anihC(ISPENaixEE)aissuR(TSOGdxEE)aissuR(TSOG
aixEE)natsikazaK(TSOGdxEE)natsikazaK(TSOG
)6etoN(aixEE)lizarB(ortemnI)6etoN(dxEE)lizarB(ortemnI)6etoN(LnxEE)lizarB(ortemnI
1E2E3E4E5E6E7ENEYEZE1W2W3W4W5W6W7W
retemtuptuO
noitarbilacdradnatS,reteMorPnoitarbilaclaicepS,reteMorP
elacs%001–0raenilrotacidnituptuogolanA)elacsraenilrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA
)reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP)noitarugifnocremotsuc–reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP
)6etoN()6etoN()6etoN()6etoN()6etoN()6etoN(
1D2D3D5D7D8D
DCLlargetnI
yalpsidlargetniDCLlatigiD 1L
)lairetamdnaepahs(tekcarbgnitnuoM
gnitnuomepiproFgnitnuomepiproF
)gnisuohISIArofelbatiustoN( leetsnobraCssL613ISIA
1B2B
egruS
)Am02-4/TRAHroflanretnI(rotcetorPtneisnarT/egruSylnosubdleiFNOITADNUOFdnaAPSUBIFORProfesooldeilppuslanretxE(rotcetorPtneisnarT/egruS
htiwelbatius 1/2 )TSUDon,snoitacifitrecASCdnaMF,XETAhtiwdnanoitcennoclacirtcele02MdnaTPN41–1S
launamgnitarepO
namreGnailatIhcnerF
1M2M4M
egaugnalgat&slebaL
namreGnailatIhcnerF
1T2T4T
etalpgatlanoitiddA
etalpleetssselniatsnogatfognitnirpresaL 2I
noitarugifnoC
Hni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°4taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°4taisp/O
motsuC
2N3N4N5N6N
setacifitreC
)tniop-9(noitarbilacfo1.3–40201NEetacifitrecnoitcepsnIngisedtnemurtsnifo1.2–40201NEredroehthtiwecnailpmocfoetacifitreC
1C6C
ytilibaecartlairetaM
strapdettewssecorpfo1.2–40201NEredroehthtiwecnailpmocfoetacifitreCstrapdettewssecorpfo1.3–40201NEetacifitrecnoitcepsnI
1H3H
rotcennoC
)gulpelamefgnitamtuohtiwesooldeilppus(-)subdleiFNOITADNUOFrofdednemmoceR(8/7subdleiF)gulpelamefgnitamtuohtiwesooldeilppus(-)APSUBIFORProfdednemmoceR(1x21MsubdleiF
yrtnethgiarts–naHgnitraHyrtneelgna–naHgnitraH
)7,5setoN()7,5setoN()7,4setoN()7,4setoN(
1U2U3U4U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
25
Note 1: Suitable for oxygen service - NOT AVAILABLE FOR SENSOR V
Note 2: Not available with sensor code G, H, M, P
Note 3: Select type in additional ordering code
Note 4: Not available with Electronic Housing code Z, R, G
Note 5: Not available with Electronic Housing code P, E
Note 6: Not available with PROFIBUS PA and FF output code 2 or 3
Note 7: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
Standard delivery items (can be differently specified by additional ordering code)– General purpose (no electrical certification)
– No meter/display, no mounting bracket, no surge protection
– English manual and labels
– Configuration with kPa and deg. C units
– No test, inspection or material traceability certificates
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'SRESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
26
BASIC ORDERING INFORMATION model 264VR Absolute Pressure Transmitter with remote seal
Select one character or set of characters from each category and specify complete catalog number.Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required.
LEDOMESAB 1– ts 5ot ht sretcarahc 2 6 4 V R X S X X X X X
%570.0YCARUCCAESAB–laesetomerhtiwrettimsnarTerusserPetulosbA
–stimilnapS-ROSNES 6 ht retcarahcaPk61dna45.0
aPk04dna76.0aPk56dna1.1
aPk061dna76.2aPk006dna01
aPk0042dna04aPk0008dna431
aPk00061dna762
rabm061dna4.5rabm004dna7.6rabm056dna11
rabm0061dna7.62rab6dna1.0
rab42dna4.0rab08dna43.1
rab061dna76.2
gHmm021dna4gHmm003dna5gHmm084dna8
gHmm0021dna02isp78dna54.1isp843dna8.5
isp0611dna4.91isp0232dna7.83
EFGHMPQS
edocesU 7– ht retcarahc S
diulflliF/lairetammgarhpaiD 8– ht retcarahc
ssL613ISIAssL613ISIAssL613ISIA
lioenociliSnedlaG-diulftrenI
nobracolaH-diulftrenI
)yletarapesdetouqebotepytnoinutpecxelaeseno()yletarapesdetouqebotepytnoinutpecxelaeseno()yletarapesdetouqebotepytnoinutpecxelaeseno(
)1etoN()1etoN(
R2W
lairetamsretpada/segnalfssecorP – 9 ht retcarahc
noitcurtsnoclaesrofssL613ISIA R
stloB 01– ht retcarahc
noitcurtsnoclaesrofsteksagtuohtiw)ECAN(ss613ISIAnoitcurtsnoclaesrofsteksagtuohtiwss613ISIA
ECAN RS
noitcennoclacirtcelednalairetamgnisuoH 11– ht retcarahc
)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA
)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA
)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA)noisrevNID(yollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocsubdleiF)02MC(5.1x02M
5.31gProtcennocnaHgnitraH
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg()ylnoesopruplareneg(
)2etoN()2etoN(
)2etoN()2etoN(
)2etoN(
)2etoN(
ABDCEGHLNMPRSTVUZJYK
snoitpolanoitiddA/tuptuO 21– ht retcarahc
Am02ot4dnanoitacinummoclatigidTRAHAm02ot4dnanoitacinummoclatigidTRAH
APSUBIFORPAPSUBIFORP
subdleiFNOITADNUOFsubdleiFNOITADNUOF
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
)4,3setoN()3etoN(
)4,3setoN()4etoN(
)4,3setoN()4etoN(
H1P2F3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
27
ADDITIONAL ORDERING INFORMATION for model 264VRAdd one or more 2-digit code(s) after the basic ordering information to select all required options
XX XX XX XX XX XX XX XX XX XX XX XXnoitacifitreclacirtcelE
aixEEytefaScisnirtnI–DG1yrogetaCIIpuorGXETAdxEEfoorpemalF–DG2/1yrogetaCIIpuorGXETA
)5etoN(ecnailpmocngisedLnxEE"N"noitcetorpfoepyT–DG3yrogetaCIIpuorGXETAylno()ASC(noitaicossAdradnatSnaidanaC 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–
)subdleiFNOITADNUOFdnaAPSUBIFORProfnxEdnaaixEtoN(AASailartsuAsdradnatShtiwylno(lavorppa)MF(lautuMyrotcaF 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–
foorpemalFdnaytefaScisnirtnI-XETAdenibmoChtiwylno(ASCdnaMF,XETAdenibmoC 1/2 )5etoN()noitcennoclacirtcele5.31gPdna02M,TPN41–
)3edoctuptuOFFrofelbaliavatoN(aixEytefaScisnirtnI-)anihC(ISPENdxEfoorpemalF-)anihC(ISPEN
aixEE)aissuR(TSOGdxEE)aissuR(TSOG
aixEE)natsikazaK(TSOGdxEE)natsikazaK(TSOG
)5etoN(aixEE)lizarB(ortemnI)5etoN(dxEE)lizarB(ortemnI)5etoN(LnxEE)lizarB(ortemnI
1E2E3E4E5E6E7ENEYEZE1W2W3W4W5W6W7W
retemtuptuO
noitarbilacdradnatS,reteMorPnoitarbilaclaicepS,reteMorP
elacs%001–0raenilrotacidnituptuogolanA)elacsraenilrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA
)reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP)noitarugifnocremotsuc–reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP
)5etoN()5etoN()5etoN()5etoN()5etoN()5etoN(
1D2D3D5D7D8D
DCLlargetnIyalpsidlargetniDCLlatigiD 1L
)lairetamdnaepahs(tekcarbgnitnuoMgnitnuomepiproFgnitnuomepiproFgnitnuomllawroFgnitnuomllawroF
xobrofepyttalF
)gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN()gnisuohISIArofelbatiustoN(
leetsnobraCssL613ISIAleetsnobraCssL613ISIAssL613ISIA
1B2B3B4B5B
egruS)Am02-4/TRAHroflanretnI(rotcetorPtneisnarT/egruS
ylnosubdleiFNOITADNUOFdnaAPSUBIFORProfesooldeilppuslanretxE(rotcetorPtneisnarT/egruShtiwelbatius 1/2 )TSUDon,snoitacifitrecASCdnaMF,XETAhtiwdnanoitcennoclacirtcele02MdnaTPN41–
1S
launamgnitarepOnamreG
nailatIhcnerF
1M2M4M
egaugnalgat&slebaLnamreG
nailatIhcnerF
1T2T4T
etalpgatlanoitiddAetalpleetssselniatsnogatfognitnirpresaL 2I
noitarugifnoCHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°4taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°4taisp/O
motsuC
2N3N4N5N6N
setacifitreC
)tniop-9(noitarbilacfo1.3–40201NEetacifitrecnoitcepsnIngisedtnemurtsnifo1.2–40201NEredroehthtiwecnailpmocfoetacifitreC
1C6C
ytilibaecartlairetaM
strapdettewssecorpfo1.2–40201NEredroehthtiwecnailpmocfoetacifitreCstrapdettewssecorpfo1.3–40201NEetacifitrecnoitcepsnI
1H3H
rotcennoC
)gulpelamefgnitamtuohtiwesooldeilppus(-)subdleiFNOITADNUOFrofdednemmoceR(8/7subdleiF)gulpelamefgnitamtuohtiwesooldeilppus(-)APSUBIFORProfdednemmoceR(1x21MsubdleiF
yrtnethgiarts–naHgnitraHyrtneelgna–naHgnitraH
)6,4setoN()6,4setoN()6,3setoN()6,3setoN(
1U2U3U4U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
28
Note 1: Suitable for oxygen service
Note 2: Select type in additional ordering code
Note 3: Not available with Electronic Housing code Z, R, G
Note 4: Not available with Electronic Housing code P, E, K
Note 5: Not available with PROFIBUS PA and FF output code 2 or 3
Note 6: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B, J, Y.
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
Standard delivery items (can be differently specified by additional ordering code)– General purpose (no electrical certification)
– No meter/display, no mounting bracket, no surge protection
– English manual and labels
– Configuration with kPa and deg. C units
– No test, inspection or material traceability certificates
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'SRESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
29
Select one character or set of characters from each category and specify complete catalog number.Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required.
BASIC ORDERING INFORMATION model 264NR Absolute Pressure Transmitter with remote seal
LEDOMESAB 1– ts 5ot ht sretcarahc 2 6 4 N R X X X X X
%570.0YCARUCCAESAB–laesetomerhtiwrettimsnarTerusserPetulosbA
–stimilnapS-ROSNES 6 ht retcarahcaPk56dna1.1
aPk061dna76.2aPk006dna01
aPk0042dna04aPk0008dna431
aPk00061dna762
rabm056dna11rabm0061dna7.62
rab6dna1.0rab42dna4.0
rab08dna43.1rab061dna76.2
gHmm084dna8gHmm0021dna02
isp78dna54.1isp843dna8.5
isp0611dna4.91isp0232dna7.83
GHMPQS
diulflliF/lairetammgarhpaiD 7– ht retcarahcssL613ISIAssL613ISIAssL613ISIA
lioenociliSnedlaG-diulftrenI
nobracolaH-diulftrenI)1etoN()1etoN(
R2W
noitcennocssecorP – 8 ht retcarahc
laesetomeR )yletarapesdetouqebotsepytnoinudnanottubtpecxelaeseno( R
noitcennoclacirtcelednalairetamgnisuoH 9– ht retcarahc
)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA)noisrevlerraB(yollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg()ylnoesopruplareneg(
)ylnoesopruplareneg(
)3etoN()3etoN(
)3etoN()3etoN(
)3etoN(
ABDCEG
)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA)noisrevlerraB(eerf-reppocyollamuinimulA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocnaHgnitraHrotcennocsubdleiF
HLNMPR
)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA)noisrevlerraB(ssL613ISIA
1/2 TPN41–)02MC(5.1x02M
5.31gP1/2 KG
rotcennocsubdleiF
STVUZ
snoitpolanoitiddA/tuptuO 01– ht retcarahc
Am02ot4dnanoitacinummoclatigidTRAHAm02ot4dnanoitacinummoclatigidTRAH
APSUBIFORPAPSUBIFORP
subdleiFNOITADNUOFsubdleiFNOITADNUOF
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
snoitpolanoitiddaoN)"edocgniredrolanoitiddA"ybderedroebot(detseuqersnoitpO
)5,4setoN()4etoN(
)5,4setoN()5etoN(
)5,4setoN()5etoN(
H1P2F3
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
30
ADDITIONAL ORDERING INFORMATION for model 264NRAdd one or more 2-digit code(s) after the basic ordering information to select all required options
XX XX XX XX XX XX XX XX XX XX XX XX
noitacifitreclacirtcelEaixEEytefaScisnirtnI–DG1yrogetaCIIpuorGXETA
dxEEfoorpemalF–DG2/1yrogetaCIIpuorGXETA)6etoN(ecnailpmocngisedLnxEE"N"noitcetorpfoepyT–DG3yrogetaCIIpuorGXETA
ylno()ASC(noitaicossAdradnatSnaidanaC 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–)subdleiFNOITADNUOFdnaAPSUBIFORProfnxEdnaaixEtoN(AASailartsuAsdradnatS
htiwylno(lavorppa)MF(lautuMyrotcaF 1/2 )noitcennoclacirtcele5.31gPdna02M,TPN41–foorpemalFdnaytefaScisnirtnI-XETAdenibmoC
htiwylno(ASCdnaMF,XETAdenibmoC 1/2 )6etoN()noitcennoclacirtcele5.31gPdna02M,TPN41–)3edoctuptuOFFrofelbaliavatoN(aixEytefaScisnirtnI-)anihC(ISPEN
dxEfoorpemalF-)anihC(ISPENaixEE)aissuR(TSOGdxEE)aissuR(TSOG
aixEE)natsikazaK(TSOGdxEE)natsikazaK(TSOG
)6etoN(aixEE)lizarB(ortemnI)6etoN(dxEE)lizarB(ortemnI)6etoN(LnxEE)lizarB(ortemnI
1E2E3E4E5E6E7ENEYEZE1W2W3W4W5W6W7W
retemtuptuO
noitarbilacdradnatS,reteMorPnoitarbilaclaicepS,reteMorP
elacs%001–0raenilrotacidnituptuogolanA)elacsraenilrofdeificepsebot(noitaudarglaiceps,rotacidnituptuogolanA
)reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP)noitarugifnocremotsuc–reteMoC(rotarugifnocTRAHdnaretemlangiselbammargorP
)6etoN()6etoN()6etoN()6etoN()6etoN()6etoN(
1D2D3D5D7D8D
DCLlargetnI
yalpsidlargetniDCLlatigiD 1L
)lairetamdnaepahs(tekcarbgnitnuoM
gnitnuomepiproFgnitnuomepiproF
)gnisuohISIArofelbatiustoN( leetsnobraCssL613ISIA
1B2B
egruS
)Am02-4/TRAHroflanretnI(rotcetorPtneisnarT/egruSylnosubdleiFNOITADNUOFdnaAPSUBIFORProfesooldeilppuslanretxE(rotcetorPtneisnarT/egruS
htiwelbatius 1/2 )TSUDon,snoitacifitrecASCdnaMF,XETAhtiwdnanoitcennoclacirtcele02MdnaTPN41–1S
launamgnitarepO
namreGnailatIhcnerF
1M2M4M
egaugnalgat&slebaL
namreGnailatIhcnerF
1T2T4T
etalpgatlanoitiddA
etalpleetssselniatsnogatfognitnirpresaL 2I
noitarugifnoC
Hni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 F.ged=erutarepmeT;C°4taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°02taisp/OHni=erusserP–dradnatS 2 C.ged=erutarepmeT;C°4taisp/O
motsuC
2N3N4N5N6N
setacifitreC
)tniop-9(noitarbilacfo1.3–40201NEetacifitrecnoitcepsnIngisedtnemurtsnifo1.2–40201NEredroehthtiwecnailpmocfoetacifitreC
1C6C
ytilibaecartlairetaM
strapdettewssecorpfo1.2–40201NEredroehthtiwecnailpmocfoetacifitreCstrapdettewssecorpfo1.3–40201NEetacifitrecnoitcepsnI
1H3H
rotcennoC
)gulpelamefgnitamtuohtiwesooldeilppus(-)subdleiFNOITADNUOFrofdednemmoceR(8/7subdleiF)gulpelamefgnitamtuohtiwesooldeilppus(-)APSUBIFORProfdednemmoceR(1x21MsubdleiF
yrtnethgiarts–naHgnitraHyrtneelgna–naHgnitraH
)7,5setoN()7,5setoN()7,4setoN()7,4setoN(
1U2U3U4U
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR SS/264XR_5
31
Note 1: Suitable for oxygen service
Note 2: Not used
Note 3: Select type in additional ordering code
Note 4: Not available with Electronic Housing code Z, R, G
Note 5: Not available with Electronic Housing code P, E
Note 6: Not available with PROFIBUS PA and FF output code 2 or 3
Note 7: Not available with Electronic housing code U, S, T, V, H, M, L, N, D, C, A, B
™ Galden is a Montefluos trademark
™ Halocarbon is a Halocarbon Products Co. trademark
Standard delivery items (can be differently specified by additional ordering code)– General purpose (no electrical certification)
– No meter/display, no mounting bracket, no surge protection
– English manual and labels
– Configuration with kPa and deg. C units
– No test, inspection or material traceability certificates
THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'SRESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING.
2600T Pressure TransmittersModel 264DR, 264PR, 264HR, 264VR, 264NR
ABB LtdHoward Road, St. NeotsCambridgeshire, PE19 8EUUKTel: +44(0)1480 475321Fax: +44(0)1480 217948
ABB Inc.125 E. County Line RoadWarminster, PA 18974USATel: +1 215 674 6000Fax: +1 215 674 7183
ABB SACE spaBusiness Unit InstrumentationVia Statale 11322016 Lenno (CO) ItalyTel: +39 0344 58111Fax: +39 0344 56278
SS
/264
XR_5
ABB has Sales & Customer Supportexpertise in over 100 countries worldwide
www.abb.com/instrumentation
The Company’s policy is one of continuous productimprovement and the right is reserved to modify the
information contained herein without notice.
Printed in Italy (12.06)
© ABB 2006