Post on 12-Jan-2017
>
Ventilation Air Conditioning RefrigerationHeating
22ºCInside
OUTSIDEHUMIDITY
PROVIDED BYHEINEN & HOPMAN
35 C
90%
productsself contained units - HHc
Self conTained uniTS
cSW self-contained marine air conditioning unit
The CSW self contained unit is specifically suitable for area’s that can difficulty served by a central air handling unint and a low cooling or heating capacity is required.
• Nominal cooling loads: 3.5 kW - 7.0 kW• Sea-water-cooled / fresh-water-cooled • Refrigerant R404a (other refrigerants are optional)• Electro-coated mild-steel casing with powder-coated paint (color on request)• Removable panels for access and maintance• Water and drain pipe size “G ½”• Electrical supply o Control circuit 220V 3ph 60Hz o Main circuit 440V 3ph 60Hz• Available options o Refrigerant: R134a or R407c o Water connection left side or right side o Electrical heating
CSW 3.5 CSW 7
Nominal cooling load (kW) 3.5 7
Nominal air flow (m3/h) 500 1050
External pressure (Pa) 300 300
Fan motor rating (kW) 0.05 0.105
Compressor motor power (kW) 3 2.8
Normal water flow (m3/h) 0.87 1.3
Dimensions H (mm) 600 600
W (mm) 760 1060
D (mm) 430 430
Weight (kg) 90 150
Electric heating (kW) 1.6 4
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
W D
H
cST self-contained marine air conditioning unit
The CST self contained unit is specifically suitable for area’s that can difficulty served by a central air handling units, like thruster room, secluded cabin, etc.
• Nominal cooling loads: 7.0 kW - 35.0 kW (available cooling load till 70kW, technical data on request)• Sea-water-cooled / fresh-water-cooled • Refrigerant R404a (other refrigerants are optional)• Electro-coated mild-steel casing with powder-coated paint (color on request)• Removable front and side panels for access and maintenance• Electrical supply o 440V 3ph 60Hz o 380V 3ph 50Hz• Available options o Control: Switch or DDC control o Refrigerant: R134a or R407c o Water connection left side or right side o Supply air: Duct or plenum grill o Fresh-water shell and tube condenser o Fresh-air connection o Electrical heating
CST02 CST03 CST05 CST08 CST10
Nominal cooling load (kW) 7 10.5 17.5 28 35
Nominal air flow (m3/h) 1080 1530 2550 4075 5100
External pressure (Pa) 300 -- 500 -- 500 -- 500 -- 500 --
Fan motor rating (kW) 0.55 0.55 0.75 0.55 1.5 0.75 2.2 1.1 2.2 1.5
Compressor motor power (kW) 1.5 2.2 3.7 6.0 7.5
Normal water flow (m3/h) 2.3 3.2 5.8 9.5 10.7
Dimensions H (mm) 1600a 1800b 1600a 1800b 1750a 2000b 1800a 2100b 1900a 2200b
W (mm) 900 900 1050 1250 1250
D (mm) 500 500 550 650 650
Weight (kg) 185 225 285 373 412
Electric heating (kW) 3 4.5 9 18 18
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
Note: (a) Air supply with duct / (b) Air supply with grill
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
cSG self-contained marine galley unit
The CSG self contained unit is an self contained unit with 100% fresh air especially designed to serve the galley. • Nominal cooling loads: 7.0 kW - 30.0 kW• Sea-water-cooled / fresh-water-cooled• Refrigerant R404a (other refrigerants are optional) • Electro-coated mild-steel casing with powder-coated paint (color on request)• Removable front and side panels for access and maintenance• Electrical supply o 440V 3ph 60Hz o 380V 3ph 50Hz• Available options o Control: Switch or DDC control o Refrigerant: R134a or R407c o Water connection left side, right side and back side o Supply air: Duct or plenum grill o Fresh-water shell and tube condenser o Remote control o Electrical heating
CSG07 CSG10 CSG15 CSG20 CSG25 CSG30
Nominal cooling load (kW) 7 10 15 20 25 30
Nominal air flow (m3/h) 750 600 850 1100 1550 1600
External pressure (Pa) 500 600 600 600 600 600
Fan motor rating (kW) 0.75 0.75 1.1 1.1 1.1 1.5
Compressor motor power (kW) 1.5 1.9 3.0 3.7 5.2 2x 3.2
Normal water flow (m3/h) 2.3 2.9 4.5 5.6 6.8 6.5
Dimensions H (mm) 1600 1700 1750 1750 1850 2000
W (mm) 550 550 750 750 750 750
D (mm) 550 550 750 750 750 750
Weight (kg) 140 180 190 210 240 370
Electric heating (kW) 4.5 9 12 13.5 18 22
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
cS self-contained marine air conditioning unit
CS self contained unit is the same as the CST type but with a square shape instead of rectangular. • Nominal cooling loads: 10.0 kW - 30.0 kW (available cooling load till 70kW, technical data on request)• Sea-water-cooled / fresh-water-cooled• Refrigerant R404a (other refrigerants are optional) • Electro-coated mild-steel casing with powder-coated paint (color on request)• Removable front and side panels for access and maintenance• Electrical supply o 440V 3ph 60Hz o 380V 3ph 50Hz• Available options o Control: Switch or DDC control o Refrigerant: R134a or R407c o Water connection left side, right side and back side o Supply air: Duct or plenum grill o Fresh-water shell and tube condenser o Fresh-air connection o Electrical heating
CS10 CS15 CS20 CS25 CS30
Nominal cooling load (kW) 10 15 20 25 30
Nominal air flow (m3/h) 1600 2600 3600 4200 4800
Fan motor rating (kW) 0.55 0.75 1.1 1.1 1.5
Compressor motor power (kW) 1.9 3.0 3.7 5.2 6.0
Normal water flow (m3/h) 2.9 4.5 5.6 6.9 9.8
Dimensions H (mm) 1600a 1800b 1700a 2000b 1750a 2000b 1800a 2000b 1850a 2150b
W (mm) 550 750 750 750 1000
D (mm) 550 750 750 750 750
Weight (kg) 207 264 322 322 375
Electric heating (kW) 4.5 9 12 12 18
Note: (a) Air supply with duct / (b) Air supply with grill
cSa air-cooled split marine air conditioning unit
The CSA spli unit is specifically suitable for area’s that can difficulty served by a central air handling units or cooling water.
• Nominal cooling loads: 10.0 kW - 30.0 kW• Air-cooled • Internal section o Refrigerant R404a (other refrigerants are optional) o Electro-coated mild-steel casing with powder-coated paint (color on request) o Removable front and side panels for access and maintenance o Electrical supply: - 440V 3ph 60Hz - 380V 3ph 50Hz• External section: o Electro-coated mild-steel casing with powder-coated paint (color on request) o Condenser air flow adjustable in two steps• Available options o Control: Switch or DDC control o Refrigerant: R134a or R407c o Supply air: Duct or plenum grill o Fresh-air connection o Electrical heating
CSA10 CSA15 CSA20 CSA25 CSA30
Internal section
Nominal cooling load (kW) 10 15 20 25 30
Nominal air flow (m3/h) 1600 2600 3600 4200 4800
Fan motor rating (kW) 0.55 0.75 1.1 1.1 1.5
Compressor motor power (kW) 1.9 3.0 3.7 5.2 6.0
Normal water flow (m3/h) 2.9 4.5 5.6 6.9 9.8
Dimensions H (mm) 1800 2000 2000 2000 2000
W (mm) 550 750 750 750 1000
D (mm) 550 750 750 750 750
Weight (kg) 207 264 322 322 375
Electric heating (kW) 4.5 9 12 12 18
External section
Condensing capacity (kW) 14 19 25 32 38
Condenser air flow (m3/h) 2x 3000 2x 4000 2x 5000 2x 6500 2x 8000
Fan motor input (kW) 2x 0.3 2x 0.3 2x 0.5 2x 0.5 2x 0.8
Dimensions H (mm) 830 880 880 880 1030
W (mm) 1350 1495 1495 1745 1745
D (mm) 565 615 615 675 675
Weight (kg) 130 150 180 210 240
C
H
W
A
B
D
H& H
H&H
D
W D
H
External section
Internal section
www.heinenhopman.com
Heinen & Hopman encourages a more
sustainable world. By providing eco-friendly solutions and serviceswe offer our clients
the option of reducing energy consumption
and thus co2 emissions. Visit
greenmanifest.info for more information.
BrazilT: +5521 3587 4241/4244E: info@br.heinenhopman.com
france - la ciotatT: +334 4204 8685E: info@heinenhopmanfrance.com
france - GrasseT: +336 3090 7786 E: info@heinenhopmanfrance.com
GermanyT:+49 4073 1680E: info@drewsmarine.com
indiaT: +9133 6499 1293E: info@heinenhopmanindia.com
italyT: +3901 8745 7970E: info@it.heinenhopman.com
The netherlands (HQ)T: +313 3299 2500E: info@heinenhopman.com
The netherlands (Rotterdam)T: +317 8890 8050E: binnenvaart@heinenhopman.nl
norwayT: +47 6919 0900E: admin@teknotherm.no
Peoples Republic of chinaT: +8621 3253 2896E: info@cn.heinenhopman.com
Peoples Republic of chinaT: +86 510 8528 1763E: ivo.klaric@teknotherm.no
PolandT: +489 1433 1800E: tmh@teknotherm.no
RomaniaT: +402 3644 8222E: office@ro.heinenhopman.com
RussiaT: +7 (4012) 308 801E: info@heinenhopman.ru
SingaporeT: +65 6897 7879E: info@sg.heinenhopman.com
South KoreaT: +8270 4901 0000E: info@kr.heinenhopman.com
SpainT: +349 3225 9668E: info@es.heinenhopman.com
SwedenT: +46 3121 7500E: mats.uden@teknotherm.no
TurkeyT: +9021 6493 8118E: info@tr.heinenhopman.com
uae (abu dhabi) T:+971 2550 4147E: info@caspuae.com
uae (dubai)T: +971 4263 5453E: info@caspuae.com
uSa - fort lauderdale, floridaT: +195 4463 0110E: info@arwmaritime.com
uSa - Houma, louisiana T: +198 5876 7989E: leblanc@leblancandassociates.com