Post on 06-Dec-2021
ROAD DESIGN PRESENTATION STANDARDS
DP013 - ROAD LIGHTING
K Net Number: 13555463 Document Revision: 5 Document Date: 28 June 2021
Document Amendment Record
Master Specification Revision 5 2
Document Amendment Record
Rev Change Description Date Author Checked Authorised
1 Initial Issue 29 July 2009 Noel O’Callaghan 2
General review of text and example drawings 23 December
2011 Natasha Stone
Alison Freer Jeremy Champion Noel O’Callaghan
3 Note 1 amended, Long/Lat added, PLIG points changed
21 January 2014
Natasha Stone Greg Gurner Noel O’Callaghan
4 Example drawing updated
11 March 2020
Disha Nayak Yanyan Xiao Joanna Davis
5 Example drawing updated 28 June 2021 Disha Nayak John Brodie Colin Boulden
Document Management This document is the Property of the Department of Planning Transport and Infrastructure (DIT) and contains information that is confidential to DIT. It must not be copied or reproduced in any way without the written consent of DIT. This is a controlled document and it will be updated and reissued as approved changes are made.
To be read in conjunction with CAD Manual & Presentation Guidelines DP001 (Master Specification PC-EDM7)
DP013 LIGHTING
Master Specification Revision 5 3
DP013 LIGHTING
1 Purpose
1.1 The ‘Lighting’ drawing is used to show the location and orientation of new lighting structures and related electrical components along with existing lighting structures and related electrical components that are to remain.
1.2 For examples of this standard see attached drawing.
1.3 The details listed below shall be arranged on separate lighting drawing unless specified otherwise.
Content
1.4 Layers to be shown as per the DIT Layer Matrix (DP001, Appendix A)
1.5 The following CAD entities are required:
a) All information in DP001 – General Requirements.
b) Symbols showing new lighting pole. (Layer = D-ELEC-Lighting Pole , block provide)
c) Symbols showing new lighting outreach and Luminaire. (outreach drawn to scale). (Layer = D-ELEC-Lighting Outreach+Luminaire, block provide)
d) Symbols showing existing lighting outreach and Luminaire. (outreach drawn to scale). (Layer = S-ELEC-Lighting Outreach+Luminaire, block provide)
e) Text identifying both new lighting structures and existing lighting structures to remain. (layer = D-ELEC-Lighting ID number, block provided)
f) Lines showing lighting conduit. (layer = D-ELEC-Lighting Conduit , line style provide)
g) Text identifying new lighting conduit (number of & size). (layer = D-ELEC-Lighting Conduit Label) (Paper Space text height =2.5mm)
h) Appropriate completed schedules. (Lighting, Circuit Details, Luminaire and pole type). (layer =D-ENHA-Schedules)
i) Text describing specific lighting requirements. (layer = D-ENHA-General Notes)(Paper Space text=2.5mm)
j) Symbols showing switchboards. (layer = D-ELEC-Lighting Pits, block provided)
k) Symbols showing junction pit locations and size. (layer = D-ELEC-Lighting Pits, block provided)
l) Text identifying supply points. (layer = D-ELEC-Service Point ID Label)
m) Hatching must indicate the clearance from any overhead or underground cabling as required by the Office of the Technical Regulator (OTR). (only required to be shown if work is expected to occur within this zone. (layer =D-ELEC-Lighting Conduit)
1.6 Survey on the Lighting Drawing shall be trimmed (i.e. survey detail should only be shown outside the extents of the design)
1.7 Existing Services shall be shown
E
40 60 80
100
120
140
160
180
0.000
20
40
60
80
MC20
1x80 RL
54839SAPN
54840SAPN
C1SAPN
RPBRPB
54838SC-1
54837798-1
54836798-1 54842
SC-13262SAPN
SP'A'
1x80 RL
54841SAPN
MSB'798'
4L
1x50 RL
1x80 RL
GRAVES STREET
ESSEX STREET
SC
NEWTON ROAD
ALBION TCE
DALE STREET
UNCONTROLLED COPY WHEN PRINTEDAMENDMENT DESCRIPTION BY CHECKNo. ACCEPTANCE DATE 100 MILLIMETRES ON ORIGINAL DRAWING ALL DIMENSIONS ARE IN METRES UNLESS SHOWN OTHERWISE
Government
of South Australia
Department of Planning,Transport and Infrastructure B
ROAD No. 6012NEWTON ROAD
JUNCTION; GRAVES STREET & NEWTON ROADMC10; CH 0 - CH 200, MC20; CH 0 - CH 100
LIGHTING
3342 42
11221104 2018/12072
201900245 201900119
4.79
4.79
WGA WGA
AI13447302
-34.881578 138.673736
3342 33
A PRELIMINARY ISSUE WGA 01.07.19B FOR APPROVAL WGA 08.08.19
WGA JOB NUMBER
60 Wyatt Street, Adelaide, SA 5000Telephone 08 8223 7433
Email adelaide@wga.com.au
NOT FOR CONSTRUCTIONFOR APPROVAL
WGA181788 06 3 6 9 12
LIGHTING DETAILSSET OUTLUMINAIRE
ASSET No. TYPELAMP LIGHT POLE
TYPE MAST HGHT O'REACHSAPN
DWG. No. TARIFFPLIG PT TYPEORIENTATION MAINTFACTOR OFFSET
COMMENTSSUPPLY No.
- AS SHOWN3262 A 150W LED 0.8 1 10.5m 2.0m EXISTING E1766 PLC NEW SAPN LUMINAIRE, LOUVRE & BRACKETDL2656, EM4108 & LED LOUVRE
- AS SHOWN54839 B 80W LED 0.8 1 8.5m 4.5m EXISTING E1768 PLC NEW SAPN LUMINAIRE & BRACKETDL2640 & EM4107
- AS SHOWN54841 B 80W LED 0.8 1 7.8m 3.0m EXISTING E1767/3 PLC NEW SAPN LUMINAIRE & BRACKETDL2506, DL1410, DL1310,
- AS SHOWN54836 A 150W LED 0.8 2 12.0m 3.0m 0.7m N/A EO NEW DPTI POLE, LUMINARE & BASEN/A
TYPE DESIGNLUMINAIRE AND POLE TYPE
A SYLVANIA ROADLED MIDI AERO 2MOD 4K
3 COMBINATION LIGHTING/SIGNAL POLE
1 SAPN STOBIE POLE
ON NEW STOBIE POLE
DL1062, DH3674, EM4107
- AS SHOWN54838 A 150W LED 0.8 3 12.0m 4.5m 0.7m N/A EO NEW DPTI COMBO POLE, LUMINAIRE & BASEN/A
COUNCIL LIGHTING DETAILSSET OUTLUMINAIRE
ASSET No. TYPELAMP LIGHT POLE
TYPE MAST HGHT O'REACHSAPN
DWG. No. TARIFFPLIG PT TYPEORIENTATION MAINTFACTOR OFFSET
COMMENTSSUPPLY No.
- AS SHOWNC1 B 60W LED 0.8 1 8.5m 2.5m EXISTING - PLC NEW SAPN LUMINAIRE, LOUVRE & BRACKETDL2640, EM4106 & LED LOUVRE
THIS SHEET PART SUPERSEDES DRAWING 3342 SHEET 21
LIGHT POLE BASE - INSTALL
LIGHT POLE BASE - EXISTING
LUMINAIRE: DPTI - INSTALL
CONDUIT - EXISTING
LUMINAIRE: DPTI - EXISTING
LIGHTING PIT (TYPE 1-8 AS INDICATED)
X X
XX
CONDUIT - INSTALL (LIGHTING DRAWINGS)
CABLE: SAPN - UNDERGROUND
CABLE: SAPN - OVERHEAD
LEGENDSYMBOL DESCRIPTION
STOBIE POLE - EXISTING
2L
EARTHED
SECURECOMBINATION LIGHTING / SIGNAL POLE BASE - INSTALL
LIGHT STRUCTURE IDCIRCUIT ID (THREE PHASE)
L15W1
REMOVE POLE & BASE
REMOVE
DPTI SWITCHBOARD
RPB
ROAD LIGHTINGRL
SIGNAL CONTROLLER ELV WITH EXTENSION HOUSINGSC
LUMINAIRE: SAPN - INSTALL
LUMINAIRE: SAPN - EXISTING
SERVICE POINT - ON STOBIE POLESP
Q3
32A TYPE 'C'10kA
MAIN SWITCH(SEALABLE ENCLOSURE)CURRENT LIMITER ISOLATOR : ROAD LIGHTING
Q1
CCT.No.1
2x16mm²(ICM = 7.6A)(D = 5.0m)
RETICULATED SERVICE:MAINS SUPPLY
SP 1/N ~ 230 V 50 Hz AS SPECIFIED
CCT.No.2
Q4
TYPE 'C' 20A
TRAFFICSIGNALSUPPLY
Q5
SURGEDIVERTER
CMVdrop=0.05%
(=0.11V)
6A 'TYPE C'
SP'A' CONSUMERMAINS LOAD
CALCVDROP/ZLOOP
LAMPS/LOAD
CCT.No.12 x 150W LED LAMPS
(54836 & 54837)
CCT. No. 12x6mm²
6mm² EARTH(ICCT1 = 1.3A)
Vdrop=0.34%(=0.78V)
Zloop=0.84Ω
STOBIE MOUNTED ROAD LIGHTING SW/BDCIRCUIT DETAILS (Single line).
Refer 4055 SHT 55
CONSUMER MAINS
6A 'TYPE C'SPARE SPARE
2 FRANGIBLE - SLIP BASE
SPARE
SIGNAL POLE BASE
- AS SHOWN54837 A 150W LED 0.8 2 12.0m 4.5m 0.7m N/A EO NEW DPTI POLE, LUMINARE & BASEN/A
- AS SHOWN54842 A 150W LED 0.8 3 12.0m 4.5m 0.7m N/A EO NEW DPTI COMBO POLE, LUMINAIRE & BASEN/A
SA POWER NETWORKS TO PROVIDEOVER/UNDER FOR PUBLIC LIGHTINGCONNECTION.
LUMINAIRE: COUNCIL - INSTALL
B SYLVANIA ROADLED MIDI AERO 1MOD 4K
EXISTING TRAFFIC SIGNALS ANDCIRCUITS TO BE REMOVED.
- AS SHOWN54840 B 80W LED 0.8 1 8.5m 3.0m EXISTING E1768 PLC NEW SAPN LUMINAIRE & BRACKETDL2640 & EM4107ON NEW STOBIE POLE
SAPN TO REMOVE EXISTING REDUNDANTSTOBIE POLES & ASSOCIATED OVERHEADCABLING (TYPICAL).
LOCATE EARTH STAKE PIT WITHIN3.5m AND 5.0m FROM STOBIE POLE.
NEW STOBIE POLE INSTALLED ASPART OF SAPN LINE DESIGN WORKS.
NEW STOBIE POLE INSTALLED ASPART OF SAPN LINE DESIGN WORKS.
EXTENT OF WORKS
EXTENT OF WORKS
FOR
CONT
INUA
TION
REF
ER D
RG 33
42 S
HEET
21
FOR
CONT
INUA
TION
REF
ER D
RG 33
42 S
HEET
21
10A TYPE 'C'
Q2 N
10A
PE CELLS1
MONTACUTE ROAD
LOWER NORTH EAST ROAD
CONSUMER MAINSCM
MSB'798'
10A'TYPE C'SAFETY CAMERA DIST(SPARE)
SCSIGNAL CONTROLLER TOP BOX (xxx)
OR
TB-Q2
NON ESSENTIALMAIN SWITCH
CONTROL
10A
PE CELL
6A'TYPEC'N
C12
LIGHTINGCONTACTOR
GPO-RCD
C1:1
C1:2
6A 'TYPE C'ROAD LIGHTING
NON ESSENTIAL DIST.
CCT.No.1
CCT.No.2
CCT.No.3
6A 'TYPE C 'ROAD LIGHTING
6A 'TYPE C'ROAD LIGHTING
10A'TYPEC'
16A'TYPEC'
SPARE SPARESPARE
SPARE SPARESPARE
CCT.SAFETYCAMERA
ASSET NUM #798
CCT.No.12 x 150W LED LAMPS
(54838 & 54842)
Vdrop=0.74% (=1.70V)Zloop=0.84Ω
A&N : 2 x 6mm²ETH : 1 x 6mm²(D=30m)(ICCT TBRL = 1.3A)
SUPPLY FROM32A MAIN SWITCHWITHIN TRAFFIC
CONTROLLERESSENTIAL
DISTRIBUTIONSECTION
CCT. SC2x16mm²
16mm² EARTH(ICCTSC = 6.3A)
CMVdrop=0.19%
(=0.44V)
LIGHTING DETAILS HAVE BEEN DESIGNED FOR CATEGORY V3 IN ACCORDANCE WITHAUSTRALIAN / NEW ZEALAND STANDARD 'AS/NZS 1158 LIGHTING FOR ROADS & PUBLICSPACES'.
ELECTRICAL DETAILS HAVE BEEN DESIGNED IN ACCORDANCE WITH AUSTRALIAN / NEWZEALAND STANDARD 'AS/NZS 3000 ELECTRICAL INSTALLATIONS (WIRING RULES)'.
ALTERNATIVE LUMINAIRE AND POLE TYPES MAY BE USED ONLY WHEN APPROVED BYPRINCIPAL ENGINEER, LIGHTING.
LIGHT POLE OFFSETS ARE MEASURED FROM CENTRE OF POLE TO THE FACE OF KERB ORBITUMEN EDGE.
ORIENTATION OF LIGHT POLES TO BE 90° TO THE CENTRE LINE ALIGNMENT OF THE ROADUNLESS OTHERWISE SHOWN.
FOR POLE, MAST ARM AND FOOTING DETAILS REFER TO STANDARD DRAWING S-4055SHEETS 19 - 22, 30, 37 - 41, 46, 49, 64 - 65 & 71.
FOR PIT DETAILS REFER TO STANDARD DRAWING S-4055 SHEETS 34 - 36 & 66 - 70.ENSURE ALL PIT LIDS ARE FINISHED TO FINAL SURFACE LEVELS.
FOR ELECTRICAL SWITCHBOARD DETAILS REFER TO STANDARD DRAWING S-4055SHEETS 43 & 54 - 58.
NOTES:1.
2.
3.
4.
5.
6.
7.
8.
10
10
10
10
6
6
4
Department for Infrastructure and Transport