Post on 11-Feb-2017
RLS35Relink unveils the innovative energy storage
Vins di Gennaro
2
Problems
● 1.3 bl people without electricity (source IEA)
● Clean energy arises, increased need to compensate intermittency
● Residential-small commercial users want to reduce energy cost and increase self-consumption from renewable energy.
3
RLS35 gen 1.0
● 3.5 kW rated power ● Single phase (230 V)● On-grid/off-grid system● Renewable energy management ● 19” rack with battery trays ● LiFePO4 2.5 khW - DOD 80%● High voltage dc-link ● Up to 15 kWh battery (6 packs)
4
● Compatible with existing PV/wind generators● Small size and weight● LiFePO4 high density battery● Long lifetime● High degree of modularity● Wider operational range● On-grid to off-grid transaction● Power generation control (patent pending)
Advantages
5
AC-link interconnection
RLS35 Standard ESS● Retrofit existing plant● Compatibility different
sources ● Standard AC voltage
● No Retrofit ● No Compatibility ● Given DC range only
6
Smaller Battery
Pictures speak louder than words.
Relink batteries needs 1/9 of volume compared to gel lead-acid batteries.
7
Lighter BatteryWell, if you need to get fit, choose lead-acid
Relink batteries weight only 1/10 of standard ones.
8
The Smallest!
Relink Li-ion battery has the highest density on the market.
Standard Li-ion battery density is 95 Wh/m3. 2.5 kWh standard battery needs a 5U tray vs. 3U tray.
9
Constant Cells Voltage
Relink batteries keep the cells voltage constant over charging-discharging cycles.
A non-uniform cells voltage reduce the overall battery performance and lifetime.
10
Longer Lifetime BatteryA gel lead-acid batteries have 500 cycles average lifetime.
Relink batteries can withstand to deep discharge for 2000-2500 cycles
11
Power modularity
Do you need more power for your appliances?
No problem, add an extra inverter.
Upgrade to 7 kW.
1
2
12
Capacity modularity
Do you need to store more energy?
No problem, add extra battery tray. Upgrade up to 15
kWh (6 trays)
1
2
3
13
Wider Temp Operative RangeLead-acid batteries ESS has narrow temperature
operating range.
RLS35 can operate in tough environments without affecting performances
14
Underlying Magic
Relink RLS35 introduces two innovative concepts● Power Generation Control (patent pending).
When the grid is missing, the renewable generator and load keep working.
● Energy Sharing Mode (patent pending). Plurality of units and renewable generators, in master-slave configuration, make possible sharing of energy among users.
15
Power Generation Control
In case of black-out, the system will keep supplying the loads and appliances as well as will not disconnect renewable power generators.
If the power generated exceeds the user power consumption, the CPU is specially controlling the generators connected reducing their output.
16
Power Generation Control
● No Light● No Production
● Keep production on● Supplies the loads
17
Energy Sharing Mode
By means of the Power Generation Control system the Energy Sharing can be achieved.
A plurality of RLS35 and renewable energy generators are connected to each other in a closed system and connected to the public grid in one single point allowing a sharing of energy among the users.
18
Energy Sharing ModeUsers with excess production will share energy to users with excess of consumption, eventually energy difference can be sold or purchased. The greater is the number of RLS35 interconnected the lower is the probability that the system need to buy energy from traders.
19
Energy Sharing Mode
PG=5Pc=2
PG=3Pc=4
PG=3Pc=0
PG=0Pc=2
Psold=3
20
Energy Sharing Mode in Offices