Raisecom RC951E-4FEE1
Ethernet over PDH Remote Gateway
Content
Introduction
Applications
Technical Data
Configure EoP
RC951E-4FEE1
INTRODUCTION
Introduction RC951E-4FEE1
• Raisecom RC951E-4FEE1 is Raisecom's intelligent Ethernet Demarcation Device (EDD) with E1 uplink.
• RC951E-4FEE1 offers 4 FE downlink ports and 1 E1 uplink.
• The device can be either deployed in a point to point topology, or in a point to multi-point topology as CPEs.
• Raisecom EDD is not only capable of doing what a layer-2 switch is capable of on Ethernet switching, but is inherently good at network diagnostices as a device working on the border.
• Apart from local CLI management, RC951E-4FEE1 is also available with inband web-based management.
RC951E-4FEE1
Applications
Point to point
Point to multipoint
Point-to-point application with E1 uplink
Point-to-multipoint application with E1 uplink
RC951E-4FEE1
Technical Data
RC951E-4FEE1 Technical Data (1/2)
• Single VCG, HDLC/GFP encapsulation software configurable
• Support LCAS, VCG members automatically adjust when E1 link status changes
• VCG-level fault pass through• E1 loopback detection and Ethernet loop
detection• Ethernet cable diagnostics• Ingress rate limit and egress traffic shaping
RC951E-4FEE1 Technical Data (2/3)
• Storm control of broadcast, multicast, unicast and dlf frames
• 8K MAC address table, full MAC address table management
• IEEE802.1Q and IEEE802.1ad, VLAN tagging and stacking
• 4 queue QoS, CoS/DSCP/port-based, queue scheduling rule including sp, wrr, sp+wrr
• IEEE802.3ad link aggregation• Layer 2/layer 3 SLA
RC951E-4FEE1 Technical Data (3/2)
• IEEE802.3ah OAM• IEEE802.1ag CFM, and ITU-T recommendation
Y.1731• CLI management access by local CONSOLE,
Telnet or SSH• In-band web-based management• GUI-based concentratively management on
Raisecom NView NNM system
RC951E-4FEE1
Configure EoP
Configure EoP
E1
Carrier Ethernet Backbone
VLAN 110
IP: 192.168.1.10
RC953-4FEE1
E1RAISECOMRC953-FE8E1
E1
IP:192.168.1.11 VLAN:100
E1RAISECOMRC953-FE8E1
SDH
VLAN 110
IP:192.168.1.12 VLAN:100
RC953-4FEE1
•GFP encapsulation mode•Client 1-4 correspond to FE port 1,2,3,4•Line 1 corresponds to inner switch port aggregate traffics from FE port 1, 2, 3, 4. It work under ‘trunk mode’ .•Data traffics using VLAN 110.•Make sure the E1 are contained in the VCG•Remotely manage RC953-4FE8E1 by telnet from central management sever PC Configure IP address 192.168.1.12/24 and 192.168.1.11/24 and VLAN ID 100.•Line 1 trunk allows VLAN 100 to pass as well as other VLANs of traffics.
Configure EoP
Login to RC953-4FEE1Via Serial
Configure EoP (serial)
Login to RC953-4FEE1
Login : raisecomPassword : Raisecom Priviliege Mode
Password : raisecom
Configure EoP (serial)
Create Vlan
GFP Mode
Configure EoP (serial)
Line 1 (E1) for Trunk
Port 1 for vlan 100, port 2 for vlan 101
Configure EoP (serial)
Interface EoP
Enable VCAT
Enable LCAS
Save Configuration
Configure IP Management
Set IP address
IP Address Subnet MaskVlan Management
Configure EoP
Login to RC953-4FEE1Via Web Browser
IP : 192.168.4..30/24
Configure EoP (Web Browser)
Login to RC953-4FEE1
IP :192.168.4.28/24
User Name : raisecomPassword : raisecom
Configure EoP (Web Browser)
Create Vlan1
2
3
4
Configure EoP (Web Browser)
GFP Mode
1
2
3
4
Configure EoP (Web Browser)
Line 1 (E1) for Trunk 1
2
3
4
5
Configure EoP (Web Browser)
Port 1 for vlan 100, port 2 for vlan 101
1
2
3
4
5
6
Configure EoP (Web Browser)
VCG Member1
2
3
4
Configure EoP (Web Browser)
Enable VCAT1
2
3
4
Configure EoP (Web Browser)
Enable LCAS1
3
2
54