lattice girder
reinforcement elevationfiber concrete with steelspring clamp Ø 2 mm
reinforcement-steel Ø 10 mm
concretecover
concretecover
• same expansion as concrete• homogeneous bond• very high strength, 88 N/mm2
• depth of water penetration in themillimeter range
• frost and de-icing salt resistance• no-tilt• pointwise contact with the
formwork, ideal for exposed concrete
Safety and efficiency without compromise
Hence reference ismade to thenew DIN-stipulationson page 51. alkali resistance,2. depth of water penetration,3. refractability,4. load bearing capacity,5. concrete bond,6. stability and no-tilt,7. frost and de-icing salt resistance.
If the spacer used by you fails to meetthe requirements of DIN 1045 and ofthe “Deutscher Betonverein” (GermanConcrete Society), you have to facethe risk of complaints.Our technically experiencedpersonnel will be pleased to helpyou in selecting the right spacerfor your application.QUICK fiber concrete spacers complywith the specifications of DIN 1045and the guidelines of the “DeutscherBetonverein” (German ConcreteSociety).
Important information!We do not accept any liability fordamage caused by plastic spacersand plastic distance tubes.
Supo N bone-shaped spacer
with nubs
Supo pyramid-shaped spacer
Quick-Supowith special plastic clamp
Supo Nwith nubs
Quick-Bipo-mD • Fiber concretespacers with wire
Bipobone-shape
Bipowith pressed tray
Bipo flat
extremely quick
Use = 800 pcs/h
Use = 90 pcs/h
The ideal spacerfor beams andcolumns
Quick-Kapo • fiber concrete spacerswith 2 mm steel clamp
Kapo
Kapo Nwith nubs for
exposed concrete
Pyramid-shapefor exposedaggregateconcrete
Bone-shapefor horizontalreinforcement
absolutelynot tilt
20
Kapo--/20
1216
Kapo--/12 –16
10 3
Kapo--/3 –10
Use = 600 pcs/h
Aus unserer Preisliste
Quick-Duplofor hollow-wll construction
Supo-Duo
hollow-wall
Pyramid-shapefor exposedfirst-classconcrete
pointwise support
Quick-Stapo • Bar spacers with fiberconcrete spacers
9/07
The wrong spacerswere used here!
Quick reinforced fiber concrete spacersAccording to DIN 1045for concrete cover from 15 to 100 mm
reinforcement-steel
concretecover
concrete cover(5 mm higherthan with toothdesign)
Bipo incl. wire
Please refer tothe cost comparisonon page 4!
NEW
NEW
Quick Fiber concrete spacersasbestos-free • for concrete cover from 15 to 100 mm • according to DIN 1045
2
Quick-Aal--/--N•--cmwith nubs
length 120
Quick-Aal -- / N (dimples)• for exposed concrete• for heavy reinforcement• rational working• for beam and ceiling reinforcemet
cuttin
g length
length 80
length 50
beam
slab
cutting length
profile shapeensures optimum
concrete bond
Aal for bar reinforcementapprox. 1 – 1.5 pcs required per m2
25
15
15
25
triangular profile VK and bumerang Nwith 25 cm cutting length
triangular profile VK and bumerang Nwith 33 cm cutting length
for reinforcement steel mesh(square mesh)
for reinforcement steel mesh(rectangular mesh)
profile shape ensuresoptimum concretebond
Quick-Bumerang--/25 cm (33 cm)with rubs
25 u. 33 cm
Quick-Dreika-V/K • Fiber concretespacers • Short length extruded profilefor reinforcement steel mesh
33 cmfor rectangular mesh
25 cmfor squaremesh
25
33
• very competitive price• approx. 1.5 – 2 pcs required per m2
• heavy-duty quality• extremely quick
33
15
25
33
Quick-MSB Supo assembly spacerfor reinforcement
Supo N bone-shaped assembly spacerwith nail hole and aluminium nail
75
Quick-Dreika-K1 • Fiber concretespacers · with 2 mm steel clamp
Dreika K1 Dreika--K1Swith bevel cut
Clamp protected bautility patent.
The steel clamp(2 mm) alwaysguarantees a tightfit, regardless ofthe iron thickness.
– up to Ø 5 mm iron
– up to Ø 10 mm iron
– up to Ø 16 mm iron
Dreika K1with nubs
aluminiumnail
to secure thereinforcement
Quick-AMB • Montage-Aalwith plastic clamp and nail hole
cuttin
g length
cuttin
g length
180 - 200 m
m
3
Quick-Dreika-D2with 1.4 mm wire
Quick-Tunnel-Kapowith wire or steel clamp
Quick-Bipo-S/Öincl. wire
a80/110
H
b 80/110
2 mm steel clamp 1.4 mm wire
very stable, no tilt
concaveunequal angle(standard)
K/Gconcaveequal angle
diagonal fixing to the reinforcement, toavoid the formation of air bubbles
with
Quick-Dreika
Quick-Vierkant forextremely heavy rein-
forcements and as form-work and reinforcement
elevation
Quick-Vierkantsquare profile
Dreika Kunequal angle
Dreika K/Gequal angle
Dreika Vequal angle
tilt r
iskno
tilt
no ti
lt
cover as required
Ø 3-10 mm
20
30
Quick-BWAreinforcement elevation
Quick-Board
2mm wire300mm long
Quick-Boardfor slotted wall reinforcement
Quick-Rollewith optional boreholes
also for slotted walls roll
15
a
b
c
Quick-Roka • for concrete tubewith 2 steel clamps 2 mm
Clamp arrangement
Quick-Clipowith plastic clamp
Clipo, the spacer that is clipped on toreinforcement bars Ø 10 mm
safety guaranteed
a
c
b
two applications, but only one typein the vertical and horizontal directions
with claw fastener
b
aQuick-Board claw fastener
without claw fastener
20 mm cutting lengthand user-defined
20 - 100 mm
25 - 50 mm
1.00
- 1.
20 m
1.00
- 1.
20 m
1.00
- 1.
20 m
1.00
- 1.
20 m
4
Quick Fiber concrete spacers, according to DIN 1045Properties:• strength 88 N/mm2
• depth of water penetration in the millimetre range• homogeneous concrete bond• frost and de-icing salt resistanceto be delivered and fitted in compliance with DIN and the manufacturer instructions.Maufacturer: Quick Bauprodukte GmbHWestendamm 3 · D-58239 Schwerte · Tel. 0 23 04/9 81 43 0 · Fax 0 23 04/9 81 43 22www.quick-bauprodukte.de · info@quick-bauprodukte.de
EUR/Unit Total EUR
Bidding text
Item Qty Type
Quickprodukts
No. of pcsrequiredper m2
Price€/–
Material costsfor 10.000 m2
No. ofpcs
used/hTotaltime
Labour costsfor 10.000 m2
(€ 33,23/h)Total costs
(material + labour)
Dreika30/25 VKfor square mesh
Dreika30/33 VKfor rectangular mesh
Bumerang30/25 Nfor square mesh
Bumerang30/33 Nfor rectangular mesh
KL 30/200for square andrectangular mesh
Supo 30 N bonefor square andrectangular mesh
Bipo 30 mDfor square andrectangular mesh
1.5 pcs
1.5 pcs
1.5 pcs
1.5 pcs
2.0 m
2.5 pcs
3.0 pcs
15.000 pcs
15.000 pcs
15.000 pcs
15.000 pcs
20.000 m
25.000 pcs
30.000 pcs
40,95/%pcs
54,46/%pcs
47,25/%pcs
57,75/%pcs
87,55/%m
27,49/%pcs
9,65/%pcs
8.169,00 €
8.662,50 €
17.510,00 €
6.872,50 €
2.895,00 €
400 pcs
400 pcs
400 pcs
400 pcs
200 m
600 pcs
90 pcs
37,50 h
37,50 h
37,50 h
37,50 h
100,00 h
41,67 h
333,33 h
3.500,00 €
1.458,45 €
11.666,55 €
9.481,50 €
8.400,00 €
9.975,00 €
21.010,00 €
8.330,95 €
14.561,55 €
Ceiling reinforcement
mostcompetitive
longesttotal time
leastcompetitive
Attention: As you can see from this comparison, the “mostcompetitive purchasing prices” do not mean you have found aneconomical solution! Time is the decisive factor here that muston no account be neglected.
6.142,50 €
7.087,50 €
1.312,50 €
1.312,50 €
1.312,50 €
1.312,50 €
7.455,00 €
Kapo 30/3-10
Supo 30 N
Dreika 30/18 K1*
Dreika 45/18 K1*
Bipo 30 mD
2.5 pcs
2.5 pcs
2.0 pcs
2.0 pcs
3.0 pcs
25.000 pcs
25.000 pcs
20.000 pcs
20.000 pcs
30.000 pcs
21,40/%pcs
23,90/%pcs
45,15/%pcs
58,80/%pcs
9,65/%pcs
5.350,00 €
5.975,00 €
9.030,00 €
11.760,00 €
2.895,00 €
600 pcs
800 pcs
600 pcs
450 pcs
90 pcs
41,67 h
31,25 h
33,33 h
44,44 h
333,33 h
1.458,45 €
1.093,75 €
1.166,55 €
1.555,40 €
11.666,55 €
6.808,45 €
7.068,75 €
10.196,55 €
13.315,40 €
14.561,55 €
Wall reinforcement
*Attention: Make sure you always chose the right cover for“Dreika”. This is due to the fact that the next largest bearer sizemust be selected if “Dreika” is suspended from the spreader bar(e.g. Dreika 45 instead of Dreika 30)
Cost comparison – Spacers
No. of pcsrequired per10.000 m2
Quickprodukts
No. of pcsrequiredper m2
Price€/–
Material costsfor 10.000 m2
No. ofpcs
used/hTotaltime
Labour costsfor 10.000 m2
(€ 33,23/h)Total costs
(material + labour)
No. of pcsrequired per10.000 m2
mostcompetitive
longesttotal time
leastcompetitive
5
Table legend:e = abbreviations for the previously described individual
ambient conditions and possible types of damager = concrete with reinforcement exposed to air and
humidityt = concrete with reinforcement exposed to salty wateru = thoroughly moistened concrete greatly exposed
to “freezing and thawing”i = concrete without/with reinforcement exposed to
chemical aggression by natural soils, ground andsea water
o = concrete without/with reinforcement exposed to considerable mechanical stress (e.g. braking, starting)
Table 2: Component catalogue: Concrete quality and concrete cover according to DIN 1045 / EN 206
Component designsand possible ambientconditions
Possible damage due to:
carbonation chloridesea
waterconcrete
coverchemical
aggression wear
Min.compressive
strength class
Corresp. to„former”
strength class
Necessaryconcrete
cover
foundation, base
foundation, base
inside components
reinforced components outdoorsa) frostb) vertical + frost + water sprayc) horizon. + frost + water sprayreinforced compo. with outdoor air accessa) without frostb) with frostc) vertical + frost + water sprayreinforced walls, stabs, beamsstairs, plattformsa) insideb) outside + frostreinfor. cellar wall, base above ground linea) frostb) frost + de-icing saltunderground parking: driving area
without reinforcement
with reinforcementconsiderable chem. aggression,without reinf.
considerable chem. aggression, with reinf.without reinforcement
with reinforcement
XO
1 2 3 4 1 2 3 1 2 3 1 2 3 4 1 2 3 1 2 3
nominal dimension(mm)XC XD XS XF XA XM
X
X
X
X
X
X
XX XX
XXX
X
XXX
X
X
XX X
X
X
XX
X
X
X
X
XX
C8/10
C16/20C25/30
C25/30C8/10
C16/20
C25/30C35/45
C30/37 (LP)
C20/25C25/30C35/45
C16/20C25/30
C25/30C30/37 (LP)
C35/45
B5
B15-B25B25-B35
B25-B35B5
B15-B25
B25-B35B45B35
B25B15-B25
B45
B15-B25B25-B35
B25-B35B35B45
–
35–
35–
20
405555
404055
2040
405560
Table 1: „Protection classes“ – Exposition classes
Possible type of Ambient „Protection Occurrence:damage: conditions class“ (examples of use)
1. Reinforcement dry XC 1 k inside componentsdamage due to wet, rarely dry XC 2 k base componentscarbonation moderately moist XC 3 k open halls
alternately wet/dry XC 4 k outside components in the rain2. Rein- not caused moderately moist XD 1 k single garagesforce- by sea wet, rarely dry XD 2 k swimming poolsment water alternately wet/dry XD 3 k carriageway surfaces, parking decksdue to caused salty air XS 1 k outside components in coastal areaschlorides by sea under water XS 2 k inner harbour components
water water spray, tide XS 3 k quay walls3. Concrete medium without de-icing agent XF 1 k outside componentsdamage water with de-icing agent XF 2 k circulation spacesdue to much without de-icing agent XF 3 k open water basinsfrost water with de-icing agent XF 4 k road surfaces4. Concrete damage slight XA 1 k liquid manure containersdue to aggresive medium XA 2 k components in/around sea waterchemicals strong XA 3 k fodder fermenting silos, cooling towers5. Concrete medium XM 1 k soils - due to pneumatic tyre carsdamage due to strong XM 2 k soils - due to solid rubber tyre carswear extreme XM 3 k soils for track vehicles
No risk of damage all ambient non-reinforcedto the concrete conditions except: X0 k foundations and
XF, XA and XM k inside components
e
k
r
t
u
i
o
Table 3: Concrete covers according to DIN 1045 / EN 206 depending on protectionclasses (exposition classes) and bar diameter
2
2,5
3
3,5
4
Ambient conditions accordingto „protection classes”
Bar diameter dsin mm:
Concrete cover cin cm:
XC 1
= dry
(e.g. inside components)
bis 10
12, 14
16, 20
25
28
3,5bis 20
4
4,5
25
28
XC 2. XC 3
= wet, seldom dry, probably moist
(e.g. base components)
4
4,5
bis 25
28
XC 4 = alternately dry – wet
(e.g. outside components in the rain)
5,5bis 28XS 1, XS 2, XS 3 = sea salts(e.g. components in coastal areas)
5,5bis 28XD 1, XD 2, XD 3 = simple salts(e.g. single garages, parking decks)
DIN Information to select the right spacer
9/2007
IDEALLY LOCATED IN GERMANYAND EUROPE
France
Sales offices in:
• Belgium• the Netherlands• Austria• Poland• Portugal• Swizerland• Scandinavia• Spain• Czech Republic• Russia
Additional sales support viaworldwide agents
Worldwide technical supportfrom civil engineers withexperience in sale
Quick Bauprodukte GmbHSchwerte (NRW)Administration and factory
Westendamm 3D-58239 SchwertePhone: 0 23 04-981 43 0Fax: 0 23 04-981 43 22
Direct phone:Sales department:0 23 04-981 43 17Technical department:0 23 04-981 43 30
Direct fax:Sales department:0 23 04-981 43 22Technical department:0 23 04-981 43 26
info@quick-bauprodukte.dewww.quick-bauprodukte.de
Denmark
Czech Republic
Dortmund airport(approx. 10 km)
Station