Pump Station Considerations for a Simple Duplex Station Discharging into a Combined Regional Force...

Post on 20-Jan-2018

215 views 0 download

description

Project Background Private development client Development includes two large retail buildings, service station, bank, and general commercial No gravity sewer service in area

Transcript of Pump Station Considerations for a Simple Duplex Station Discharging into a Combined Regional Force...

Pump Station Considerations for a Simple Duplex Station Discharging into a Combined Regional

Force Main

Rachel Rausch, EIT

Site Location

Bluffton, SC

Project Background

• Private development client

• Development includes two large retail buildings, service station,

bank, and general commercial

• No gravity sewer service in area

Project Background

Unique Design Considerations• Donation of project to Beaufort Jasper Water and Sewer

Authority (BJWSA)

• Little topographical variability on site

• Deep wetwell

• Site pump station will pump into 16” combined regional

force main Unknown conditions in regional force main

Design Solution: Data Collection

• BJWSA Standards

• Force main record drawings

• Force main operating conditions

• Operating pressure

• Flow

Design Solutions: Calculations• Wastewater Flow Estimate

• Site Storage Volume

• Force Main Operating Conditions

• Choosing Pumps

Design Solutions: CalculationsWastewater flow from site:Peaking Factor=4Qpeak=92.4

BJWSA storage volume requirement:

Storage volume in site MH and pipes > 24 hour volume from site

Pump SelectionExisting force main conditions analyzed

• Regional Force Main Pump station on• 1,000 gpm @ 70’ TDH

• Regional Force Main Pump Station CP-67 off

• No flow in regional force main

• Two C factors analyzed for each system curve

System Curve-Pumps On

0 200 400 600 800 1000 12000

50

100

150

200

250System Curve-Regional Force Main Pumps On

TDH C1 MIN [FT] TDH C1 MAX [FT] TDH C2 MIN [FT] TDH C2 MAX [FT] PUMP CURVE #1

PUMP CURVE #2 PUMP CURVE #3 PUMP CURVE #4 PUMP CURVE #5 PUMP CURVE #6

Flowrate (gpm)

TDH

(ft)

Design Point:310 gpm at 102’ TDH

Hazen-Williams C Factors:C1=110C2=130

System Curves-Pumps Off

0 200 400 600 800 1000 12000

50

100

150

200

250

300

350System Curve-Regional Force Main Pumps Off

TDH C1 MIN [FT] TDH C1 MAX [FT] TDH C2 MIN [FT] TDH C2 MAX [FT] PUMP CURVE #1

PUMP CURVE #2 PUMP CURVE #3 PUMP CURVE #4 PUMP CURVE #5 PUMP CURVE #6

Flowrate (gpm)

TDH

(ft)

Design Point:410 gpm at 96’ TDH

Hazen-Williams C Factors:C1=110C2=130

Pump Selection

Other Calculations

• Cycle time

• Buoyancy Calculations

• High groundwater table

• Deep wetwell, approximately 24 feet deep

Final Pump Station Layout

Project Status• BJWSA Approval• Construction Status

Questions?

Lessons Learned