PulseEight wireless intelligent completion technology in ... · IDSP Packer – Successful downhole...

Post on 06-Aug-2020

6 views 0 download

Transcript of PulseEight wireless intelligent completion technology in ... · IDSP Packer – Successful downhole...

TDK-CS-P8C1-0519©2019 Tendeka. All rights reserved. www.tendeka.com

Jul44

46

48

50

52

54

56

58

Aug Sept Oct Nov Dec Jan FebDate

Wireless Vs Memory Gauge Pressure Comparison

Pres

sure

(bar

)

Pressure Wireless Gauge Decoded

Pressure 3rd Party Memory GaugePressure Wireless Gauge Internal Log

Well Data

Offshore NorwayLocation:

Gas & Gas Condensate producerWell Type:

June 2011Installation Date:

Depth: 2500m

7”Tubing Size:

100°CTemperature:

FBHP: 900psi FWHP: 450psi

Norway

A Scandinavian operator had experienced downhole pressure and temperature gauge failure in their well, losing vital data required to plan for tertiary recover techniques in this mature and heavily depleted field.

The ChallengeLow well energy with little pressure drop across the wellhead choke coupled with condensate slugging are potentially challenging for Fluid Harmonics production telemetry.

Tendeka SolutionTendeka restored measurements using the PulseEight Wireless PT Gauge. No surface acquisition equipment or data relay system was required as the existing wellhead pressure sensor was used to read the signal.

Project ResultsThe gauge transmitted data for 226 days. On retrieval, the data was compared to a memory gauge deployed in the assembly, confirming the veracity of the transmitted and recorded Wireless Gauge data.

– Successful installation, hanging off the WDG on an IDSP Packer

– Successful downhole data acquisition– Successful wireless transmission to surface

Case Study:PulseEight wireless intelligent completion technology regains P/T data from clients wells in Norway

Tendeka’s PulseEight system uses unique Fluid Harmonics Production Telemetry to regain pressure & temperature from clients wells.