Post on 14-Aug-2020
ProjectThe Liquor Store - Manchester
Eagle 3-in-1 LED p416 Owl LED p419
400
Emergency8 Product Groups 56 Products
401
www.anselluk.comwww.anselluk.com
Emergency
LED Downlights
50
IP65 Bulkhead
405
LED Downlights
50
Exit Boxes
412
LED Downlights
50
Suspended Edge
416
LED Downlights
50
IP65 Surface Edge
417
402
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
LED Downlights
50
Twin Spot
419
LED Downlights
50
LED Emergency Downlight
421
LED Downlights
50
Panel Pod Emergency
426
LED Downlights
50
LED/CFL and LV Emergency Packs
427
403
DeliverDeliverDesigned to
DeliverDeliverDesigned to
404
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
• Small and unobtrusive LED bulkhead• Supplied with self-adhesive
legend• Optic design provides
optimum performance for escape route lighting
• Side and rear cable entries• Screwless gear tray for
ease of installation• Viewing distance 17 metres
Swift LED BulkheadSupplied c/w Legend and Integral Driver
Accessory
210
100
40
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 94lmStandard Mode 147lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
Code Lamp Description
ASWTLED/3M LED 3W Maintained / Non-Maintained
ASBP/1 3.6V 600mAh Ni-Cd Replacement Battery
Mounting Height (M)
2.546
333
6.786
22.73
4.866
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
2.92.6-
6.87.4-
1.91.9-
3.83.8-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
3YR
IP65
405
www.anselluk.comwww.anselluk.com
• Ultra-slimprofileLEDpolycarbonate bulkhead
• Supplied with self-adhesive legend
• Side and rear cable entries• Hinged screwless gear tray
for ease of installation• Viewing distance 18 metres
352
110
55
AGLED/KITWith Guardian Installed
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Guardian LED BulkheadSupplied c/w Legend and Integral Driver
Code Lamp Description
AGLED/3M LED 3W Maintained / Non-Maintained
AGLED/KIT Semi-Recessing Kit - White
ASBP/2 3.6V 1500mAh Replacement Ni-Cd Battery
Accessories
Mounting Height (M)
2.546
2.933
66.16
2.22.43
4.54.86
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
3.23.6-
6.27.3-
1.91.9-
3.84.2-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
3YR
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 119lmStandard Mode 160lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
406
Project - LaddawRomford, UK
407
www.anselluk.comwww.anselluk.com
Kite LED Emergency BulkheadSupplied with Legend and Integral Driver
270
120
45
• Modernultra-slimprofileIP65 LED polycarbonate bulkhead
• Self-test as standard• Aesthetically designed for
modern appearance• Supplied with self-
adhesive legend• 20mm side and rear cable
entries• Hinged screwless gear
tray for ease of installation• Viewing distance 20
metres
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Mounting Height (M)
2.54
3.53.6-
6.58-
2.63.2-
78.6-
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
3.43.5-
68.8-
3.23-
7.28-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Code Lamp Description
AKTLED/3M/ST LED 3W Maintained / Non-Maintained
ASBP/1 3.6V 600mAh Ni-Cd Replacement Battery
Self-Test
Accessory
3YR ST
LED Information
Total (W) 3WLumens DeliveredEmergency Mode 68lmStandard Mode 123lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
408
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Centurion LED Bulkhead Supplied c/w Legend and Integral Driver
3YRST
• High lumen performance LED polycarbonate bulkhead for increased spacings
• Supplied with self-adhesive legend
• Self-test as standard• Outperforms 8W T5 and
exceeds performance of Guardian by 56%
• 20mm conduit entry positions and rear teminal box entry
• Hinged screwless gear tray for ease of installation
• Viewing distance 18 metres• 50,000 hours average
lifetime
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
352
6411
0
Self-Test
Accessory
Code Lamp Description
ACELED/3M/ST LED 6W Maintained / Non-Maintained
ASBP/2 3.6V 1500mAh Ni-Cd Replacement Battery
Mounting Height (M)
2.546
3.54.65
7.28.810.2
3.43.33.6
6.86.97.3
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
3.653.65
-
7.47.75
-
3.43.5-
7.27.5-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
LED Information
Total (W) 6WLumens DeliveredEmergency Mode 150lmStandard Mode 229lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
409
www.anselluk.comwww.anselluk.com
Osprey High Rack LED BulkheadSupplied c/w Integral Driver
• ModernslimprofileIP65LED polycarbonate bulkhead
• Compact high polished reflectordesigntoproviderequired light level from high mounting heights
• High performance LED’s and optical performance allows increased spacing ratios
• Cold store option incorporates an intelligent integral heat management system to operate in cold store applications down to -30°C
• Self-test as standard• Aesthetically designed for
modern appearance• 20mm side and rear cable
entries
Cold Store
Accessories
LED Information
3YR
330
135
69
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Mounting Height (M)
10151015
554
3.1
1314.25
1314.25
54
4.95.1
20.524.720.724.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
10151015
AOSLED/3M
AOSLED/3M/CS
AOSLED/3M
AOSLED/3M/CS
----
----
6.7526
1.5
171217
10.4
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Code Lamp Description
AOSLED/3M LED 10.5W Maintained / Non-Maintained
AOSLED/3M/CS LED 22W Maintained / Non-Maintained
ASBP/15 3.6V 4Ah Ni-Cd Replacement Battery
ASBP/16 3.6V 4Ah Ni-Cd Replacement Battery (for use with Cold Store fitting)
IP65
Total (W) 10.5WCold Store 22WLumens DeliveredEmergency Mode 254lmStandard Mode 559lmLumens Delivered Cold StoreEmergency Mode 238lmStandard Mode 552lmCCT 6500KInput 220/240VHertz 50/60HzOperating Temp 0°C to 40°C Cold Store -30°C to 5°C
ST410
Quick and easy installationSelf-Test as standard
Osprey LED 10.5W5 fittings to reach required lux level
Halogen Twinspot 2x20W7 fittings to reach required lux level
High Rack Bulkhead vs. Traditional Halogen TwinspotWarehouse racking aisle scheme (15 metre ceiling height and 2m aisle width)
Osprey LED
57
Maintenance freeBetter spacing ratio for less fittings
411
www.anselluk.comwww.anselluk.com
Standard
Self-Test
Accessory
AENLED/3M/W
AENLED/3M/SG
Code Lamp Description
AENLED/3M/W LED 2.6W Maintained/Non-Maintained - White
AENLED/3M/SG LED 2.6W Maintained/Non-Maintained - Silver Grey
AENLED/3M/W/ST LED 2.6W Maintained/Non-Maintained - White
ASBP/2 3.6V 1500mAh Ni-Cd Replacement Battery
• Ultra slim modern LED exit sign
• Self-test option• Neat picture frame
appearance compared to conventionalfluorescentexit signs
• Supplied with all legend options - arrow down, arrow up and arrow
left/right• Viewing distance 29
metres
LED Information
Total (W) 2.6WCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
316
196
36.5
Encore LED Exit SignSupplied c/w Legends and Integral Driver
3YR ST
IP20
412
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Project - Harveys RestaurantRhuddlan, UK
413
www.anselluk.comwww.anselluk.com
• White steel LED exit box sign with legend
• Larger dimensions enableseasyretrofitreplacement of fluorescentproducts
• Viewing distance 37 metres
375 60
185
Watchman LED Exit SignSupplied c/w Legend and Integral Driver
Code Lamp Description
AWLED/3M LED 3W Maintained / Non-Maintained
AG8/L/AD Legend - Arrow Down
AG8/L/AR Legend - Arrow Right
AG8/L/AL Legend - Arrow Left
AG8/L/AU Legend - Arrow Up
ASBP/3 3.6V 1800mAh Ni-Cd Replacement Battery
Legends
Battery
3YR
LED Information
Total (W) 3WCCT 6000KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP20
414
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
• White steel exit box sign with legend
• Viewing distance 37 metres
376
185
60
Guardsman Exit SignSupplied c/w Lamp and Legend
AG8/3M
Legends
Code Lamp Description
AG8/3M T5 8W Maintained / Non-Maintained - White
AG8/L/AD Legend - Arrow Down
AG8/L/AR Legend - Arrow Right
AG8/L/AL Legend - Arrow Left
AG8/L/AU Legend - Arrow Up
IP20
415
www.anselluk.comwww.anselluk.com
Eagle 3-In-1 LED Exit SignSupplied c/w Integral Driver and Legend
3YR ST
• Modern, slim, 3-In-1 LED Exit Sign
• Self-test option• Onefittingthatenables
choice of three different mounting options :- suspension, recessed or side arm wall mounting
• Viewing distance 25 Metres
364 86
48.5
45
32948
45
152
70
Semi Recessed
Suspended
Side Arm Wall Mounted
323
AE3LED/3M/SISemi Recessed
AE3LED/3M/WSuspended
AE3LED/3M/WSide Arm Wall Mounted
Standard
Self-Test
Legends
Battery
Code Lamp Description
AE3LED/3M/W LED 2.5W Maintained/Non-Maintained - White
AE3LED/3M/SI LED 2.5W Maintained/Non-Maintained - Silver
AE3LED/3M/W/ST LED 2.5W Maintained/Non-Maintained - White
AE3LED/ALAR Double Sided Legend - Arrow Left and Right
AE3LED/L/AD Double Sided Legend - Arrow Down
AE3LED/L/AU Double Sided Legend - Arrow Up
ASBP/4 3.6V 800mAh Replacement Ni-Cd Battery
LED Information
Total (W) 2.5WCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP20
416
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
336 130
8310
160
51
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
• Compact high performance IP65 polycarbonate surface emergency luminaire
• Self-test as standard• Optional hanging blade
legends (supplied with self-adhesive legend as standard) for enhanced appearance
• Aesthetically designed for modern appearance
• High output LED performance and distribution allows maximum spacing providing reduced cost
• Viewing distance 25 metres
Harrier LED IP65 Blade Exit SignSupplied c/w Self-Adhesive Legend (Optional Blade Legend ordered separately)
3YRST
Self-Test
Legends
Battery
Code Lamp Description
AHARLED/3M/ST LED 6W Maintained/Non-Maintained
AHARLED/ALAR Harrier LED Double Sided Legend - Arrow Left and Right
AHARLED/L/AD Harrier LED Double Sided Legend - Arrow Down
AHARLED/L/AU Harrier LED Double Sided Legend - Arrow Up
ASBP/5 7.2V 1500mAh Ni-Cd Replacement Battery
LED Information
Total (W) 6WLumens DeliveredEmergency Mode 120lmStandard Mode 299lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65
417
Project - The Liquor StoreManchester, UK
418
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
• Self-test Twin LED emergencyfloodlightforindustrial applications
• Robust white moulded enclosure
• Exceeds performance of 2x20W halogen equivalent
• Moulded polycarbonate heads
300 70
290
LED Information
Total (W) 5WLumens Delivered 488lmCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
IP65 Owl LED Twin SpotSupplied c/w Integral Driver
3YRST
Self-Test
Battery
Code Lamp Description
ATSLED/3NM/IP65/ST LED 5W Non-Maintained
ASBP/6 3.6V 6Ah Ni-Cd Replacement Battery
IP65
419
www.anselluk.comwww.anselluk.com
LED Twin SpotSupplied c/w Integral Driver
3YR
310 113
277
• Twin LED emergency floodlightingforindustrialapplications
• Exceeds performance of 2x20W halogen equivalent
• Robust metal enclosure in an opal colour
• Moulded polycarbonate heads
LED Information
Total (W) 3WCCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°Accessory
Code Lamp Description
ATSLED/3NM LED 3W Non-Maintained
ASBP/7 3.6V 4Ah Ni-Cd Replacement Battery
IP20
420
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Signal LED Emergency DownlightSupplied c/w Remote Driver and Battery Pack
3YR
• Economic and compact LEDNon-Maintainedfixed
downlight• White powder coat paint
finish• LED combines power and
green charge indicator• 3 hour emergency output• 120° beam angle
34
33
Ø45
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Mounting Height (M)
2.546
3.13.43
6.78.69
3.13.43
6.78.69
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
3.33.1-
6.58.3-
3.33.1-
6.58.3-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Accessory
Code Lamp Description
ASLED/3NM LED 1.5W Non-Maintained
ASBP/8 3.6V 2Ah Ni-Cd Replacement Battery
LED Information
Total (Watts) 1.5WLumens DeliveredEmergency Mode 124lmBeam Angle 120°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0°C to 45°C
IP20
421
www.anselluk.comwww.anselluk.com
Beacon LED Emergency Adjustable DownlightSupplied c/w Remote Driver and Battery Pack
3YR • LED Non-Maintained adjustable die-cast
aluminium downlight• 3 hour emergency output• Power and green charge
LED are discreetly incorporated within the head
• 120° beam angle
Ø78
52
60
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Accessory
Code Lamp Description
ABLED/3NM LED 5W Non-Maintained
ASBP/9 3.6V 4.5Ah Ni-Cd Replacement Battery
Mounting Height (M)
2.546
3.13.43.5
6.78.610
3.13.43.5
6.78.610
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
3.33.1-
6.58.3-
3.33.1-
6.58.3-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Total (Watts) 5WLumens DeliveredEmergency Mode 136lmBeam Angle 120°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0°C to 45°C
LED Information
IP20
422
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Raven LED Emergency DownlightSupplied c/w Integral Driver and Battery Pack
3YRST
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
95
• Recessed Self-test emergency downlight
with self-contained inverter and battery pack• Integral components forfast-fitinstallation• Option of escape route or open area models• High performance optic design• Pre-wired with 150mm
rubber insulated cable for ease of installation
• Up to 15 metres spacing between luminaires
Ø110
109
Code Lamp Description
ARALED/ER/3NM/ST LED 3W Non-Maintained - Escape Route
ARALED/OA/3NM/ST LED 3W Non-Maintained - Open Area
ASBP/14 3.7V 2.6Ah Li-ION Replacement Battery
Self-Test
Accessory
Mounting Height (M)
2.546
3.3 3.5 3.5
7 8.8 9.5
3.3 3.5 3.5
7 8.8 9.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.54**
3.53.5**
88.5**
3.53.5**
88.5**
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
Emergency downlight with integralinverter and battery pack
Escape Route
Open Area
IP20
LED InformationTotal (Watts) 3WLumens DeliveredEmergency ModeOpen Area 176lmEscape Route 224lmBeam Angle Open Area 49.3°Escape Route 62.4°CCT 6500KInput 220/240VHertz 50/60HzOperating Temp 0C° to 40C°
423
www.anselluk.comwww.anselluk.com
Merlin LED Emergency DownlightSupplied c/w Remote Driver and Battery Pack
3YR ST
• Ultra-lowprofilerecessedself-test emergency downlight
• Self-test as standard• Option of escape route or
open area models• Highspecificationoptic
design and performance allows increased spacing providing reduced cost
• Up to 17.8 metres spacing between luminaires
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Ø85
57
72
Self-Test
Accessory
Code Lamp Description
AMELED/ER/3NM/ST LED 5W Non-Maintained - Escape Route
AMELED/OA/3NM/ST LED 5W Non-Maintained - Open Area
ASBP/9 3.6V 4.5Ah Ni-Cd Replacement Battery
Escape Route
Open Area
Mounting Height (M)
2.546
2.74
4.5
6.91010
2.74
4.5
6.91010
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.546
68-
14.219.5
-
68-
14.219.5
-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
IP20
LED Information
Total (Watts) 5WLumens DeliveredEmergency ModeOpen Area 277lmEscape Route 227lmBeam Angle Open Area 108°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0°C to 45°C
424
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
Falcon LED Surface Emergency DownlightSupplied c/w Integral Driver and Battery Pack
3YRST
• Compact surface ultra-low profilerecessedself-testemergency downlight
• Self-test as standard• Option of escape route or
open area models• Highspecificationoptic
design and performance allows increased spacing providing reduced cost
• Up to 19.6 metres spacing between luminaires
Ø150 44.6
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
** 0.5 lux minimum must be used for areas larger than 60m², the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
*** Explanation of the symbols:- Transverse - Wall Distance to wall from side of fitting Transverse - Transverse Side to side spacing Axial - Wall Distance to wall from end of fitting Axial - Axial End to end spacing
Self-Test
Accessory
Code Lamp Description
AFALED/ER/3NM/ST LED 5W Non-Maintained - Escape Route
AFALED/OA/3NM/ST LED 5W Non-Maintained - Open Area
ASBP/10 3.6V 3Ah Ni-Cd Replacement Battery
Escape Route
Open Area
Mounting Height (M)
2.546
3.33.94
7.49
9.5
3.33.94
7.49
9.5
Transverse to Transverse
Transverse to Wall
Open (Anti-Panic) area (0.5 Lux Minimum) **
Axial to Wall
Axial to Axial
Mounting Height (M)
2.54-
---
---
67.8-
1216.8
-
Transverse to Transverse
Transverse to Wall
Escape route 2 metres wide (1 Lux minimum) *
Axial to Wall
Axial to Axial
***
***
IP20
LED Information
Total (Watts) 5WLumens DeliveredEmergency ModeOpen Area 152lmEscape Route 140lmBeam Angle Open Area 108°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
425
www.anselluk.comwww.anselluk.com
Top Housing View
Bottom Housing Viewshowing Emergency LED
LED Panel Pod Emergency for Infinite and Endurance LED Panels
3YR ST
• Integral emergency pod to convert any new Ansell
InfiniteLEDandEnduranceLED panel to emergency, instantly
• Simple, quick twist and lock fixing
• Supplied with a pre-wired 1 Metre cable for ease of installation
• Total light output of 220lm. Tri-colour LED shows green for healthy running condition,red/flashingforfault conditions and white for emergency operation
• UK Patent No. GB2522285• European Patent Applied
For No. 15165652.7 • Irish Patent Applied For
No. 2015/0128• EC Registered Design No
002712232-0001
170
53
LED Information
Total (Watts) 5WLumens Delivered 220lmBeam Angle 120°CCT 6500KInput 230VHertz 50/60HzOperating Temp 0C° to 45C°
Self-Test
Accessory
Code Lamp Description
AIRMLED/POD/3NM/ST LED 5W - Cool White
ASBP/11 3.6V 4.5Ah Ni-Cd Replacement Battery
STEP 2Locate and twist Panel Pod into position. Connect incoming supply to pre-leaded cable
STEP 1Unscrew coin plug from back of AnsellInfiniteLEDPanel
IP20
426
Warrington: +44 (0) 1942 433333 Belfast: +44 (0) 2890 773750
LED/CFL Emergency Lighting Pack
• Emergency lighting pack for use with LED and Mains GU10 CFL Lamps as follows:-
GU10 LED Lamps Minimum: 3W Maximum: 8W
GU10 CFL Lamps Minimum: 11W Maximum: 14W
• 55mm cut-out aperture• Will provide 3 hour duration
• 60mm cut-out aperture• Will provide 1 hour
duration on 50W lamp and 3 hours duration on 20W lamp
• For use with halogen light sources only
Low Voltage Emergency Lighting Pack
ALVP/3M
ACFLP/3
Code Description
ACFLP/3 Maintained / Non-Maintained - CFL/LED
ALVP/3M Maintained - Low Voltage IP20
IP20
427