Post on 15-Jan-2016
ProfileGünther Spelsberg GmbH + Co. KG
Our company’s profile
1904 - 1948• 1904 Founding of Kaiser & Co. by Walther Kaiser + Ernst Spelsberg
Company – History
• 1905 Start of production of insulating tube and accessories
• 1926 Start of production of cast iron, moisture-proof boxes
• 1941 Formation of the focus on moisture-proof conduit boxes
• 1948 First participation at the industrial trade fair in Hanover
1948 - 2001• 1956 Renamed as Günther Spelsberg KG after
the split from Kaiser
Company – History
• 1957 Continual expansion of the product range in the “surface-type installation” field
• 1991 New building of the branch factory in Buttstädt, Thuringia (50 employees, 6000m2, 2000 pallet stations, production of Red Range conduit boxes, cavity wall boxes and IBT concrete construction products)
• 1996 New building of the administration building and manufactured goods
warehouse in Schalksmühle • 2001 Start of production with of WKE conduit boxes with E30 – E90 function
2003• 2003 Opening of the new production site in Schalksmühle after two years of construction
The Company Today
• €11 million investment volumes
• 60,000 m³ ground excavation
• 104,000m³ interior space
• 20,000m² production and storage space
• approx. 6000 pallet stations for half and assembly units
StrategySpelsberg right up-to-date
• Development and sale of individual customer solutions
• Creation of growth impulses for existing markets
• Stronger focus on the target groups of the industry
Continuous trend from the series manufacturer to the order manufacturer
Growing investment in product development
• Opening new markets through innovative products, e.g. fireproofing
Enclosure SystemsWhat matters is the right enclosure!
Your specialist for industrial applications
Enclosure Systems Coordinated variety
• Polystyrene: – impact resistant, withstands temperatures up to 40°
• Polycarbonate: – glass fibre reinforced, UV resistant,
– withstands temperatures up to 70°
• choice of 13 basic enclosures with up to
3 different cover heights
• can be sealed with leads as standard Special colors
• Hinges– Hinges (including screws and
drilling template) convert removable covers into hinged covers
• Small up to TK 1809• Large from TK 1811
• Wall mounting brackets– For external mounting of all
boxes
Accessories
• Padlock – For protection against
unauthorised access
Accessories
• Thumb grips – Set of 4 pieces to fix on the
cover screws
Accessories• Mounting plates
– Insulated mounting plates for all sizes
– Metal mounting plates
• Spacers– Spacers in plastic
determing the distance between PC-boards and mounting plates and the base of the box
• DIN-profiles– 15x5x 1 up to TK
1809– 35x7.5x1 up to TK
3625– Can be mounted to
the longest or the shortest side
Accessories
Enclosure Systems Coordinated variety• Combinable without limit
• Extensive accessories
• Modular tooling
• Metric tooling
• Can be sealed with leads as standard
• Different cover heights
Enclosure systems Certificated security• Certificated
• Continuous quality assurance
• UL – certified laboratory
• Polycarbonate UL Nema 4X
• Distribution boards EK acc. to Nema 4X
From development to manufacture - All from a single source
• Planning, Development• Prototype building• Inspection/Testing• Project design• Engineering• Production• Brand labelling• Continuous further development
Enclosure systems Coordinated variety
NEW !! Serie NG, Plastic - enclosures
• IP 65• Plastic ABS und polycarbonate• smooth and shiny surface• RAL 7035• Fits to BUD/Fibox/Ensto/Bopla etc. (Norm enclosures)• Cover grey or transparent • corrosion free cover screws• accesories• complete availibility from Januar 2008 on• UL conformity, certification acc. To UL 50 in process
Development to manufactureAll from a single source
Development to manufacture Own tool construction
Technology trends2-component technic for customisedsolutions• 2 component-injection
moulding • Quick and safe assembly • No fitting necessary• The 2 component enclosures
are extra impact resistant • Self-sealing membrane
entries• No special tools necessary
Aluminium enclosures• Corrosion protection due to powder
coating• Painting, silver grey RAL 7001, AL SI
12 Material• Other colours on request• Unpowdered enclosures available• High cemical resistance and
protection against electromagnetic interference
• IP 66 protection• Complete range from 50x45x30mm
up to 330x230x110mm
Application example
Application example
Application example
Application example
Application example
Application example
Application example
Application example
Enclosure systemsfrom Spelsberg
Fire Protection
Fire prevention for the electronical installation What does it mean? Function guarantee?
Test acc. to DIN 4102 ETK Unit - temperature – time - curve
Fire prevention for the electronical installation What does it mean? Function
guarantee?
The whole performance system is tested,
which means that only a performance system
(with junction box) including cable construction system can have a function guarantee
Dowels, cabels and other fasteners have to have an approval as well!
DIN 4102 Part 12
Fire testing acc. to DIN 4102 Part 12,MPA NRW
Installation of ceiling assembly with test samples WKE 200 and 400
Fastening of the cables with approved materials
Fire testing acc. to DIN 4102 part 12,MPA NRW
after approx. 5 minutes,
temperature after the ETK approx. 500°C
Fire testing acc. to DIN 4102 part 12,MPA NRW
Lighted with four oil burners
Test assembly power cable
Examination on
• interruption
and
• short-circuit
Test assembly exterior view
Test assembly after turning off the burners (>90 min)
Fire prevention for the electrotecnical installation
- The solution in junction boxes!
Fire prevention for the electrotecnical installation
The solution in junction boxes WKE
Junction boxes with function guarantee E30 / E60 / E90 acc. to DIN 4102 part 12
• MPA approved • E 90• 0,5² to 16²• IP 54• very flexible cable entry point• plastic box = safeguarded isolation• non halogen
Fire prevention for the electrotecnical installation The solution in junction boxes WKE
Junction boxes with function guarantee E30acc. to DIN 4102 part 12
• MPA approved • 0,5² to 35²!• very robust – non vandalisum• IP 66• very flexible – terminal block => fuse possible• non halogen • plastic box = safeguarded isolation
Hinges Fuse
Fire prevention for the electrotecnical installation The solution in junction boxes WKE
Fire Statistics
What is the leading killer in fires?
Why Must We Contain Smoke, Toxic Gases and Fire?
3/4 of all fire deaths are caused by smoke inhalation (PVC!!!).
Approximately 57% of people killed in fires are not in the room of the fire’s origin.
Visibility - 47% of survivors caught in a fire could not see more than 12 feet.
Smoke travels 120-420 feet per minute under fire conditions
Spelsberg Campaign ?
• Win a journey to Europe!
• For more information please visit our booth!!
Thanks for your attention!