1

SPLIT CORE CURRENT TRANSFORMERS

TC / TQ

TC / TQ Technical Features

TypePrimary Current

ARated Burden1)

Cl. 0,5 / VA* Cl.1 / VA* Cl.3 / VA*

TQ 18-B

100/1A – 0,2 –

125/1A – 0,2 –

150/1A – 0,2 –

200/1A – 0,2 –

250/1A – 0,2 –

150/5A – 1 –

200/5A – 1 –

250/5A – 1 –

TC 18

60/1A – – 0,2

75/1A – – 0,2

100/1A – – 0,2

125/1A – – 0,2

150/1A – – 0,2

200/1A – 0,2 0,2

250/1A – 0,2 –

TQ 27

200/1A – 0,2 –

250/1A – 0,2 –

300/1A – 0,2 –

400/1A – 0,2 –

500/1A – 0,2 –

250/5A – 1 –

300/5A – 1 –

400/5A – 1 –

500/5A – 1 –

TQ 42 / TQ 84

250/1A – 0,5 –

300/1A – 0,5 –

400/1A – 0,5 –

500/1A – 0,5 –

600/1A – 0,5 –

750/1A 0,5 – –

800/1A 0,5 – –

1000/1A 0,5 – –

300/5A – 1,5 –

400/5A – 1,5 –

500/5A – 1,5 –

600/5A – 1,5 –

750/5A – 1,5 –

800/5A 1,5 – –

1000/5A 1,5 – –

TC18 / TQ42 / TQ84 Technical specificationsEnviromental conditions

Location Indoor use

Operating temperatureTC18: -5ºC to +40ºCTQ42/TQ84: -10ºC to +55ºC

Relative humidity 5% - 85%, non condensing

Protection degree IP20

Application conditions

Standard IEC 60044-1

Rated short-time thermal current 60 x ln/1s

Rated insulation level 100% ln

Rated frequency 0,72/3-kV

Class of insulationTC18: ETQ42/TQ84: E (+120ºC)

Primary window dimensionsTC18: max. Ø 18mmTQ42: max. Ø 42mmTQ84: 42mm x 84mm

Secondary leads

TC18: 5m cable 0,5mm2

3m cable 0,5mm2 (200-250/1A)

TQ42/ 1A: L= 3m cable 0,5mm2 flexible

TQ84: 5A: L= 0,5m cable 1,5mm2 flexible

Application

The very compact TQ/ TC are especially designed for connection to digital

measurement systems. All TC /TQ are supplied with colour coded leads se-

condary leads. Correct closing of the current transformer/sensor is guaran-

teed by a distinct sound of a “click”. Two UV-resistant ty-raps are supplied

with the current transformer whicn can be easily mounted around the pri-

mary conductor.

All TC18/ TQ42 and TQ84 current transformers are capable of supplying

the specified burden at the end of the secondary leads. The accuracy of

these current transformers (TQ42/TQ84) results in highly accurate measu-

rement.

All TQ18-B current sensors and all TQ27 current transformers are capable

or supplying a burden of 0.2 VA at the end of the cable. The accuracy class

1 for all these CT’s are perfect for high accurate kWh measurements.

Split core current transformer / sensor

n Very easy mounting is guaranteedn Fast fixation with two UV-resistant tie wrapsn Also in class 1 available for high accurate kWh measurementsn All TC/TQ.. split core CT’s are supplied with colour coded leads

NEW

1) Burden specified at the end of the secondary leads* Accurcy conform IEC 600-44-1, valid from 5 to 120%ln

TQ18-B / TQ27 Technical specificationslth 60*ln/1s

Insulation class E (max. 120ª)

Protection degree IP20

Ambient temperature -5 to +55ºC

According EC 60044-1

Primary conductorTQ18-B: max. Ø 18mmTQ 27: max. Ø 28mm

Secondary leads1A: L= 3m cable 0,5mm2

5A: L= 0,5m cable 1,5mm2

Remark Only for insulated primary conductors

05

2

CURR

ENT TR

ANSF

ORM

ERS

SPLIT CORE CURRENT TRANSFORMERS 05

Dimension / Wiring diagrams

TC18

TQ 27

TQ18-B

TQ 42 / TQ 84

Wiring Diagram

Dimensions

Wiring Diagram

Dimensions

Wiring Diagram

Dimensions

Wiring Diagram

Dimensions

TQ42