PowerLogic PowerView v2.0 software
Schneider Electric 2- North American Operating Division
PowerLogic PowerView v2.0
●New native support for devices
●Software updates
●New PDI tool (PMC usage)
●Target availability is October 2008.
Schneider Electric 3- North American Operating Division
Supported Devices● The list of Supported Devices are:
●Power Meter 210
●Power Meter 500
●Power Meter 710,750
●Power Meter 810, 820, 850, 870– M22, M2222 and M26 extended I/O modules
●Enercept
●ION 6200
●Micrologic Trip Units Types P, H and A
● Maximum number of Devices:●The maximum number of devices for this software application is 32.
Schneider Electric 4- North American Operating Division
Device Communications to devices
●Device Connections● Automatic Detection (Auto discovery of networked devices)
●Software polls the network for supported devices ●User may “speed up” the detection process with scan options●Devices are automatically named but can be re-configured by user
● Manual connections●End users will have the option to manually add and delete device connections.
● Supports Ethernet gateways, including EGX models and PM8ECC
●Communications ● Supports Ethernet gateways, including EGX models and PM8ECC
● Devices with communication issues are highlighted in red
Schneider Electric 5- North American Operating Division
Auto Detection of Devices
Schneider Electric 6- North American Operating Division
Selective Scan Option
Schneider Electric 7- North American Operating Division
Data Logging● Onboard Data Logging:
●The Power Meter 800 (PM800) family will perform onboard data logging●The PM800 onboard logging interval is set in PMCU. PowerView Software will upload at regular 2 hour intervals automatically.
● PC-based Data Logging:●The Power Meter 210, Power Meter 710 & 750, and Micrologic Trip Units A, P and H will perform PC-based data logging.
●The PC-based data logging interval default is 15 minutes.●The PC-based data logging interval can be changed by the end user.●The measurements that are PC based data logged cannot be modified.
● Quantities (measurements) Logged:●Current●Voltage●Power●power factor●energy,●demand power●demand current●total harmonic distortion (THD).
Schneider Electric 8- North American Operating Division
Database Management
●Database Backups:●The option to backup the database will be available.
●Database Restores:●The option to restore the database will be available.
●Historical Database Management:●The Historical database will be maintained below 2.9 GB in size.
●Data will be deleted from the Historical database as first in – first out (FIFO) to prevent growth over 2.9GB.
●Deleted Historical data is not retained.
Schneider Electric 9- North American Operating Division
Real Time Display – Summary View
Schneider Electric 10- North American Operating Division
Report Builder●Basic Queries:
● Device(s) + Measurement(s)+ time range= Output (trends, charts, tables)● Both PC and Onboard (PM8’s) data available in database.
●Pre-configured Queries:● Focused on providing end user with historical information on their Electrical Energy
usage and power demand.●Energy usage for last day, week, month●Energy TOU (Time of Use) or Energy Bands outputs
● Support for Time of Use Metering includes.●defining up to 3 schedules●Each Schedule can contain
-> up to 10 periods (bands) for energy accumulation-> Supports weekends, special days, holidays
●Reports Viewer:● End user will be expected to have Microsoft Excel to view reports.
●All costing and other calculations (eg. Terrifications, rates) can be done manually by the customer in Excel.
Schneider Electric 11- North American Operating Division
General Report Example
Schneider Electric 12- North American Operating Division
Report Builder
Schneider Electric 13- North American Operating Division
Export the Data
Schneider Electric 14- North American Operating Division
Time of Use Setup
Schneider Electric 15- North American Operating Division
Time of Use Setup
Schneider Electric 16- North American Operating Division
Time of Use Setup
Schneider Electric 17- North American Operating Division
Time of Use Setup
Schneider Electric 18- North American Operating Division
Time of Use Setup
Schneider Electric 19- North American Operating Division
Appendix A – Data Logging per Device
Schneider Electric 20- North American Operating Division
>