Post on 06-Sep-2018
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 0075wi03 valid until 31st December 2018
www.passivehouse.com
Category: Window FrameManufacturer: Pierret System,
Transinne,Belgium
Product name: QUESTY
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
Comfort UW = 0.78 ≤ 0.80 W/(m2 K)UW ,installed ≤ 0.85 W/(m2 K)with Ug = 0.70 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.70
CERTIFIEDCOMPONENTPassive House Institute
cool, temperate climate
phBPassive House
efficiency class phE phD phC phB phA
Pierret SystemZI Le Cerisier, 10, 6890 Transinne, BelgiumT +32 (0) 61 65 50 10 |B philippe.delvaux@pierret-system.com | -Í http://www.pierret-system.com |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Timber frame (0,13 W/(m3K)) with insulated external aluminium shell. Used Pane: 48 mm (4/18/4/18/4),intersection of the Glass: 20 mm.
Explanation
The window U-values were calculated for the test window size of 1.23 m× 1.48 m with Ug = 0.70 W/(m2 K).If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.70 0.66 0.60 0.54 W/(m2 K)↓ ↓ ↓ ↓
Window UW = 0.78 0.75 0.71 0.67 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.
The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/4 QUESTY
www.passivehouse.com
Frame width U-value frame Ψ -panel edge Temp. Factorbf Uf Ψg fRsi=0.25
Framevalues mm W/(m2 K) W/(m K) [-]
Top (to) 118 0.74 0.028 0.78
Side (s) 118 0.74 0.028 0.78
Bottom (bo) 118 0.74 0.028 0.78
Mullionflying
(fm) 137 0.77 0.027 0.78
Spacer: SWISSPACER V Secondary seal: Polysulfide
Validated installations
Timber frame
Ψinstall W/(m K)Top 0.022Side 0.022Bottom 0.026
UW ,installed = 0.85 W/(m2 K)
EIFS
Ψinstall W/(m K)Top 0.010Side 0.010Bottom 0.016
UW ,installed = 0.82 W/(m2 K)
Cavity wall (operable)
Ψinstall W/(m K)Top 0.012Side 0.012Bottom 0.016
UW ,installed = 0.82 W/(m2 K)
3/4Component-ID: 0075wi03
www.passivehouse.com