Post on 20-Jul-2020
xx
High Efficiency Stainless Steel Gas Fired Water Heater
Phoenix Light Dut y
High Efficient Operation -up to 97% thermal efficiencyModulating Combustion System -3:1 turndown ratio -25,000 to 76,000 Btuh -Low NOx compliantSuperior Tank Construction of 316L Stainless Steel -3 tank sizes: 50, 60 & 80 gallon -Laser welded precision - No anode rods needed -LightweightHigh Efficient Combustion Heat Exchanger - patent pending cupronickel heat exchanger design boasts excellent heat transfer properties and resists corrosionCondensate System - Patent pending condensate system with removable built-in neutralizing Ph cartridge Venting - 2” PVC, CPVC or uLC S636 pipe -Combined vent length of 150 feet -two pipe balanced or unbalanced venting systemEase of Installation -top ports on inlet and outlet (patent pending integral inlet mixing device) -top connect auxiliary port for recirculation line or air handler piping increases overall efficiencyAdvanced Electronic Control - Easy to read LCD (icon and text) displayHigh Quality Stainless Steel Appearance
120 Braley Road, East Freetown, MA 02717 • 1-800-323-9651 • www.htproducts.comMKTLIT-54 - 02 / 2014 © HTP
S p e c i f i c a t i o n sPhoenix LD
In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.
4.000
FE
HOTOUTLET
AUXILIARY RETURN
COLD INLET
T & P
8.000
C
D
A
B
GALLONS A*
HS76-45
FC
45 42-3/4" 33-1/4"
54-3/4"
36-1/4"
7-1/4" 23" 32-1/4"
HS76-55 60 36-1/4"
36-1/4"
7-1/4"
D
23" 32-1/4"
HS76-75 80 62-3/4" 33-1/4"
E
7-1/4" 23" 32-1/4"
33-1/4"
B# LEDOM
MODEL # INPUT MODULATION
AIR INTAKE/EXHAUST
VENT SIZE
INLET/OUTLET SIZE
AUXILIARY CONN.
GASLINE
CONN.
SYSTEM RELIEF
PIPE SIZE
SHIPPINGWEIGHT
MAX. TEMPERATURE
LIMIT
HS76-45
25,000 -76,000 2" 3/4" 3/4" 1/2" 3/4" 160HS76-55
HS76-75
LP-441-D11/26/12
* HEIGHTS ARE PRELIMINARY
4.000
FE
HOTOUTLET
AUXILIARY RETURN
COLD INLET
T & P
8.000
C
D
A
B
GALLONS A*
HS76-45
FC
45 42-3/4" 33-1/4"
54-3/4"
36-1/4"
7-1/4" 23" 32-1/4"
HS76-55 60 36-1/4"
36-1/4"
7-1/4"
D
23" 32-1/4"
HS76-75 80 62-3/4" 33-1/4"
E
7-1/4" 23" 32-1/4"
33-1/4"
B# LEDOM
MODEL # INPUT MODULATION
AIR INTAKE/EXHAUST
VENT SIZE
INLET/OUTLET SIZE
AUXILIARY CONN.
GASLINE
CONN.
SYSTEM RELIEF
PIPE SIZE
SHIPPINGWEIGHT
MAX. TEMPERATURE
LIMIT
HS76-45
25,000 -76,000 2" 3/4" 3/4" 1/2" 3/4" 160HS76-55
HS76-75
LP-441-D11/26/12
* HEIGHTS ARE PRELIMINARY
MODEL BTUH VENT SIZE
GASLINE
GALLONCAPACITY
INLET/ OUTLET
SIZE
RELIEF VALVE
AUXCONN.
RECOVERY GPH AT
90˚ F RISE
FIRSTHOUR
RATING
PH76-50 25,000 - 76,000 2” 1/2”
503/4” NPT 3/4” FNPT 3/4” NPT 98
133 GAL.
PH76-60 25,000 - 76,000 60 140 GAL.
PH76-80 25,000 - 76,000 80 154 GAL.
MODEL A B C D E F SHIPPINGWEIGHT
THERMALEFFICIENCY
MAX. TEMP LIMIT
PH76-50 46.75” 36.25” 33.25” 7.25” 23” 32.25” 155 LBS 97%
160˚FPH76-60 54.75” 36.25” 33.25” 7.25” 23” 32.25” 170 LBS 97%
PH76-80 72.75” 36.25” 33.25” 7.25” 23” 32.25” 195 LBS 95%
HTP Made In Am
erica • HTP Made In A
mer
ic
a • HTP Made In A
merica • HTP Made In
Am
eric
a •
SCAQMD Rule 1146.2SCAQMD Rule 1146.2
Limited Warranty: Residential: 10 year if registered online & 7 year if not registeredCommercial: 3 year (upgradeable to 5 year with additional charge)
NO Anode Rods Needed!All coated tanks require anodes to delay the inevitable corrosion and tank failure. The average commercial water heater lasts about 6 years. The Commercial Phoenix stainless steel tank will outlast any coated steel tank in the market.SCALE BUILD-UP