Palar River Bridge

Post on 12-Dec-2015

27 views 8 download

description

Planning analysis and Design of High Level River Bridge across River Palar as a part of Vellore Bypass

Transcript of Palar River Bridge

Batch No:1404

D Praveen Kumar10121A0114M M S Siddartha 10121A0130S Hemanth Kumar 10121A0151K Ajit Kumar 11125A0103 P Raghavendra 11125A0107

IV B-Tech Civil Engineering

WELCOME

Planning, Analysis and Design of high level bridge across River Palar

as a part of Vellore Bypass

Under the guidance of

External Guide

M. Venkat Das,

Das consultants, Chennai.

Internal Guide

V. Mahesh,Sree Vidyanikethan Engineering College.

Location of Site

Contents Hydraulic Calculations Review of Geotechnical Report Bridge Components

Hydraulic Calculations Discharge Calculations Linear Water Way Scour Depth Calculations

Review of Geotechnical Report

Design of Bridge Components• Design of Super Structure

– Design of Deck slab– Design of Girders

• Design of Sub Structure System– Design of piers– Design of Abutments

• Design of Foundations• Miscellaneous Items

– Neoprene Bearing Design– Design of Retaining Walls

IRC CodesThe Following Indian Roads Congress(IRC) codes will be referred for various loading and design parameters. IRC 5 – IRC 6 – 2000/2010 IRC 21 _ IRC 78 _ IRC 83-II -

ASK

Progress till now… Selecting suitable foundation. Learned to analyze all the components

using staad.pro software. Learned to design all the components

of bridge using Manual means in working stress method.

Calculations LWW• Depth of water (d) = 2.79 m• Assumed afflux (H) = 0.15 • Velocity of approach (Va = V x d/(d+H)) =

2.183 m/sec • Head due to velocity of approach (Hva =

Va2/2g) = 0.244 m • Total head (Ht =H + Hva) = 0.394 m • Velocity through vent (Vv = (2gHt)0.5) =

2.781 m/sec

Calculations LWW• Linear waterway required (Q/( Vv x d))

= 544.208 m • Proposed Span arrangement = 27 x

21.6 m = 583.2 - 26 - 1.5 = 555.7 m• Linear waterway provided = 555.7 m >

544.208 m • Hence Okay