adancime 60 mtop screen 45 mHstatic 5.05 m
testQ (mc/h) Hdin (m) rezultat masura la galeata
1 0.00 5.05 static2 0.45 5.62 5l/40s3 0.86 6.15 5l/21s4 1.13 6.60 5l/16s
Delta Pmax (m) 10 25% max pt gravel pack (fara gravel max 10%)H din max(m) 15Qmax (mc/h) 7
Qapa necesar (mc/h) 2
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
40.00
45.00
Productivitate putQapa (mc/h)
H din (m)
(fara gravel max 10%)
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
40.00
45.00
Productivitate putQapa (mc/h)
H din (m)
masuratoare SQ 2-55hdin Qfantana PI caracteristici producatorm mc/h h mc/h
5.05 0.00 32 35.62 0.45 45 2.56.15 0.86 60 1.56.60 1.13 66 0.5
10.00 3.10
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
5
10
15
20
25
30
35
40
45
QputQ pompa pres med
presiune hidrofor1 kg/cm2 2 kg/cm2 3 kg/cm2
17 7 -330 20 1045 35 2551 41 31
(adancimea din caracteristica pompei minus 5 m, nivelul static, minus 10 m pt fiecare kg/cm2)
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
5
10
15
20
25
30
35
40
45
QputQ pompa pres med
(adancimea din caracteristica pompei minus 5 m, nivelul static, minus 10 m pt fiecare kg/cm2)
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m sq 2-55m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 32 35.62 0.45 0.79 20.62 30.62 45 2.56.15 0.86 0.77 21.15 31.15 60 1.56.60 1.13 0.60 21.6 31.6 66 0.5
10.00 3.10 0.58 extrapolare 25 35
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
SQ 2-35 Qpompa
Sq 2-55 Qpompa
SQ 2-70 Qpompa
ONKM 100 Qpompa
ONKM 150 Qpompa
B007 Qpompa
presiune hidrofor1 kg/cm2 2 kg/cm2 3 kg/cm2
17 7 -330 20 1045 35 2551 41 31
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
SQ 2-35 Qpompa
Sq 2-55 Qpompa
SQ 2-70 Qpompa
ONKM 100 Qpompa
ONKM 150 Qpompa
B007 Qpompa
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m ONK150m mc/h mc/h/m m m h mc/h
5.00 0.00 20 30 102 0.35.57 0.45 0.79 20.57 30.57 78 0.66.10 0.86 0.77 21.1 31.1 67 0.96.55 1.13 0.60 21.55 31.55 58 1.2
10.00 3.10 0.57 extrapolare 25 35 48 1.537 1.825 2.1
zestre put 15 2.4diam (m) 0.19 7 2.7vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 2.2sectiune fantana (m2) 0.028339viteza apa (m/s) 0.021565diametru max particula nisip transportata (mm) 0.072662
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 1.5 kg/cm23.5 kg/cm2
87 82 6263 58 3852 47 2743 38 1833 28 822 17 -310 5 -15
0 -5 -25-8 -13 -33
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m ONK100m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 62 0.35.62 0.45 0.79 20.62 30.62 49 0.66.15 0.86 0.77 21.15 31.15 42 0.96.60 1.13 0.60 21.6 31.6 37 1.2
10.00 3.10 0.58 extrapolare 25 35 30 1.523 1.816 2.1
zestre put 10 2.4diam (m) 0.19 6 2.7vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.15 20 3010 0.75 25 3520 2.25 35 4530 3.75 45 5535 4.5 50 60
verificare ascensiune nisipQ pompa (mc/h) 1.8sectiune fantana (m2) 0.028339viteza apa (m/s) 0.017644diametru max particula nisip transportata (mm) 0.048641
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
Column K
Column N
presiune hidrofor0.5 kg/cm21.5 kg/cm23.5 kg/cm25 kg/cm2
5052 42 22 739 29 9 -632 22 2 -1327 17 -3 -1820 10 -10 -2513 3 -17 -32
6 -4 -24 -390 -10 -30 -45
-4 -14 -34 -490 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
0
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
Column K
Column N
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m ONK100m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 62 0.35.62 0.45 0.79 20.62 30.62 49 0.66.15 0.86 0.77 21.15 31.15 42 0.96.60 1.13 0.60 21.6 31.6 37 1.2
10.00 3.10 0.58 extrapolare 25 35 30 1.523 1.816 2.1
zestre put 10 2.3diam (m) 0.19 6 2.4vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 1.8sectiune fantana (m2) 0.028339viteza apa (m/s) 0.017644diametru max particula nisip transportata (mm) 0.048641
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
-20
-10
0
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
Column O
presiune hidrofor0.5 kg/cm21.5 kg/cm23.5 kg/cm24 kg/cm2
l/min 405 34 26 8 4
10 33 25 6 215 30 22 2 -320 27 17 -3 -825 20 10 -10 -1530 13 3 -17 -2235 6 -4 -24 -29
38.33333 0 -10 -30 -3540 -4 -14 -34 -39
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
-20
-10
0
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
Column O
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m sq 2-35m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 19 35.62 0.45 0.79 20.62 30.62 29 2.56.15 0.86 0.77 21.15 31.15 39 1.56.60 1.13 0.60 21.6 31.6 43 0.5
10.00 3.10 0.58 extrapolare 25 35
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 2.75sectiune fantana (m2) 0.028339viteza apa (m/s) 0.026956diametru max particula nisip transportata (mm) 0.113534
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Qpompa pres min
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 2 kg/cm2 3.5 kg/cm2
4 -6 -2114 4 -1124 14 -128 18 3
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Qpompa pres min
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m sq 2-55m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 32 35.62 0.45 0.79 20.62 30.62 45 2.56.15 0.86 0.77 21.15 31.15 60 1.56.60 1.13 0.60 21.6 31.6 66 0.5
10.00 3.10 0.58 extrapolare 25 35
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.05 20 3010 0.25 25 3520 0.75 35 4530 1.25 45 5535 1.5 50 60
verificare ascensiune nisipQ pompa (mc/h) 3.1sectiune fantana (m2) 0.028339viteza apa (m/s) 0.030387diametru max particula nisip transportata (mm) 0.144273
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 2 kg/cm2 3.5 kg/cm2
17 7 -830 20 545 35 2051 41 26
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m sq 2-70m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 43 35.62 0.45 0.79 20.62 30.62 60 2.56.15 0.86 0.77 21.15 31.15 79 1.56.60 1.13 0.60 21.6 31.6 87 0.5
10.00 3.10 0.58 extrapolare 25 35
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 3.1sectiune fantana (m2) 0.028339viteza apa (m/s) 0.030387diametru max particula nisip transportata (mm) 0.144273
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Qpompa pres min
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 2 kg/cm2 3 kg/cm2
28 18 845 35 2564 54 4472 62 52
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Qpompa pres med
Qpompa pres min
Q pompa pres max
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m B007m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 23 35.62 0.45 0.79 20.62 30.62 42 2.46.15 0.86 0.77 21.15 31.15 49 2.16.60 1.13 0.60 21.6 31.6 55 1.8
10.00 3.10 0.58 extrapolare 25 35 62 1.268 0.6
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 3.1sectiune fantana (m2) 0.028339viteza apa (m/s) 0.030387diametru max particula nisip transportata (mm) 0.144273
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Column L
Column K
Column M
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 2 kg/cm2 3.5 kg/cm2
8 -2 -1727 17 234 24 940 30 1547 37 2253 43 28
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Column L
Column K
Column M
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
masuratoare hdinamic put secathdin Qfantana PI 15 m 25 m B005m mc/h mc/h/m m m h mc/h
5.05 0.00 20.05 30.05 15 35.62 0.45 0.79 20.62 30.62 27 2.46.15 0.86 0.77 21.15 31.15 31 2.16.60 1.13 0.60 21.6 31.6 35 1.8
10.00 3.10 0.58 extrapolare 25 35 40 1.243 0.6
zestre putdiam (m) 0.19vol (l/m) 28.34
Put cu nivel scazut si infundat
hdin min put secat si infundathdin Qfantana PI 15 m 25 mm mc/h mc/h/m m m
5 0 0.1 20 3010 0.5 25 3520 1.5 35 4530 2.5 45 5535 3 50 60
verificare ascensiune nisipQ pompa (mc/h) 3.1sectiune fantana (m2) 0.028339viteza apa (m/s) 0.030387diametru max particula nisip transportata (mm) 0.144273
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Column L
Column K
Column M
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
presiune hidrofor1 kg/cm2 2 kg/cm2 3 kg/cm2
0 -10 -2012 2 -816 6 -420 10 025 15 528 18 8
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 50
10
20
30
40
50
60
Qput
Column L
Column K
Column M
Qput secat 15 m
Q put secat 25 m
Q put infundat
Qput infundat si secat 15 m
Q put secat 25 m si infundat
2.988