Post on 16-Oct-2021
NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
B006‐6586‐P000
B006‐6586‐P000
NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
The product described in this document is a licensed product of NCR Corporation.
NCR and NCR SelfServ are trademarks of NCR Corporation. Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Where creation of derivative works, modifications or copies of this NCR copyrighted documentation is permitted under the terms and conditions of an agreement you have with NCR, NCR's copyright notice must be included.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent.
© 2007, 2008, 2009, 2010, 2012, 2013by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com. All Rights Reserved
i
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationContents
IntroductionAudience...............................................................................................1 ‐ 1
About This Document ...........................................................................1 ‐ 1
NCR Site Preparation Services Contact Information.............................1 ‐ 1
Revision Record ....................................................................................1 ‐ 1
Customer Responsibilities
Notice ...................................................................................................2 ‐ 1
Site Compliance ....................................................................................2 ‐ 1
Customer Actions .................................................................................2 ‐ 1
Standards Compliance
Radio Frequency Interference ..............................................................3 ‐ 1FCC Radio Frequency Interference Statement ................................3 ‐ 1Canadian Class A Device Declaration...............................................3 ‐ 1
Safety ....................................................................................................3 ‐ 1Safety Directive................................................................................3 ‐ 1Harmonised Safety Standard...........................................................3 ‐ 1
Electromagnetic Compatibility (EMC)...................................................3 ‐ 1Immunity Standards ........................................................................3 ‐ 1EMC Directives.................................................................................3 ‐ 1Emission Standards..........................................................................3 ‐ 1Additional Requirements for 220V ‐ 240V Units .............................3 ‐ 1
Accessibility ..........................................................................................3 ‐ 1NCR Optimum Height ......................................................................3 ‐ 1Lowered Heights..............................................................................3 ‐ 1
Product Overview
General Description ..............................................................................4 ‐ 1Options ............................................................................................4 ‐ 1
Acoustics...............................................................................................4 ‐ 1
Heat Dissipation....................................................................................4 ‐ 1
Product Identification...........................................................................4 ‐ 1
Site Requirements
Positioning the ATM .............................................................................5 ‐ 1
Floor......................................................................................................5 ‐ 1
Doorways and Corridors .......................................................................5 ‐ 1
Wall.......................................................................................................5 ‐ 1Wall Cavity.......................................................................................5 ‐ 1Installing Through a Glass Wall........................................................5 ‐ 1Collar Tolerance...............................................................................5 ‐ 1
Ambient Lighting...................................................................................5 ‐ 1
Temperature and Humidity ..................................................................5 ‐ 2Normal Operating Range (Interior Environment)............................5 ‐ 2Normal Operating Range (Exterior Environment) ...........................5 ‐ 2Storage Range (Up To Three Months) .............................................5 ‐ 2
Transit Range (Up To One Week) ....................................................5 ‐ 2Extreme Power On Range (Up To One Hour) ..................................5 ‐ 2
Barometric Pressure .............................................................................5 ‐ 2
Power Requirements
AC Power Requirements.......................................................................6 ‐ 1
Input Voltage Setting............................................................................6 ‐ 1
Grounding.............................................................................................6 ‐ 1
Transient Protection.............................................................................6 ‐ 1Transient Protection Products.........................................................6 ‐ 1
Cable Requirements
Cable Preparation.................................................................................7 ‐ 1
Data Line Transient Protection.............................................................7 ‐ 1Transient Protection Products.........................................................7 ‐ 1
High Order Communications Standard Cable (RS‐232) ........................7 ‐ 1
RS‐232 Cable (9 pin) .............................................................................7 ‐ 1
Alarm Interface Cables .........................................................................7 ‐ 2Basic Alarm Cable ............................................................................7 ‐ 2Enhanced Alarm Cable ....................................................................7 ‐ 2
Remote Status Monitor ........................................................................7 ‐ 3Shortening the Cable.......................................................................7 ‐ 3
Remote Relay Cable..............................................................................7 ‐ 3
Ethernet Standard Cable ......................................................................7 ‐ 3
Power Cable..........................................................................................7 ‐ 3
Decals
Card Orientation Window ....................................................................8 ‐ 1
Advert Window ....................................................................................8 ‐ 1Logo Collar ......................................................................................8 ‐ 1Advert Collar or Open Advert Collar................................................8 ‐ 1
Cash Blank Window..............................................................................8 ‐ 1
Entry/Exit Decals ..................................................................................8 ‐ 1
Decal Placement ...................................................................................8 ‐ 1
Variant Details ‐ CEN, Short SLeeve
Package Dimensions .............................................................................9 ‐ 1
ATM Dimensions...................................................................................9 ‐ 1Without Pressurisation....................................................................9 ‐ 1With Pressurisation .........................................................................9 ‐ 1
Weights and Floor Loading...................................................................9 ‐ 1Without Pressurisation....................................................................9 ‐ 1With Pressurisation .........................................................................9 ‐ 1
Collar Dimensions.................................................................................9 ‐ 2Standard ..........................................................................................9 ‐ 2Advert..............................................................................................9 ‐ 2Logo .................................................................................................9 ‐ 2Open Standard ................................................................................9 ‐ 2
Open Advert .................................................................................... 9 ‐ 2Open Extended................................................................................ 9 ‐ 2
Cable Entry ........................................................................................... 9 ‐ 2
Security Bolts........................................................................................ 9 ‐ 3
Bolt Holes ............................................................................................. 9 ‐ 3Standard, Advert, Logo or Open Advert Collar................................ 9 ‐ 3Open Standard or Open Extended Collar ........................................ 9 ‐ 3
Hole in the Wall.................................................................................... 9 ‐ 4Hole at Optimum Height ................................................................. 9 ‐ 4Hole at Lowered Height .................................................................. 9 ‐ 4
Facia Items ........................................................................................... 9 ‐ 5Topmost Viewable Facia Item......................................................... 9 ‐ 5Heights and Depths ......................................................................... 9 ‐ 5Distance for Voice Guidance ........................................................... 9 ‐ 5
Servicing Areas ‐ Optimum ‐ Single ATM.............................................. 9 ‐ 6Standard, Advert, Logo or Open Advert Collar................................ 9 ‐ 6Open Standard or Open Extended Collar ........................................ 9 ‐ 6
Servicing Areas ‐ Optimum ‐ Side By Side ............................................ 9 ‐ 7Standard, Advert, Logo or Open Advert Collar................................ 9 ‐ 7Open Standard or Open Extended Collar ........................................ 9 ‐ 7
Servicing Areas ‐ Minimum ‐ Single ATM ............................................. 9 ‐ 8Standard, Advert, Logo or Open Advert Collar................................ 9 ‐ 8Open Standard or Open Extended Collar ........................................ 9 ‐ 8
Servicing Areas ‐ Minimum ‐ Side By Side ............................................ 9 ‐ 9Standard, Advert, Logo or Open Advert Collar................................ 9 ‐ 9Open Standard or Open Extended Collar ........................................ 9 ‐ 9
Clearances ‐ Corridor.......................................................................... 9 ‐ 10
Clearance ‐ Pressurisation Fan ........................................................... 9 ‐ 10
Clearances ‐ Exterior Wall .................................................................. 9 ‐ 10Standard, Open Standard or Logo Collar....................................... 9 ‐ 10Advert Collar ................................................................................. 9 ‐ 10Open Advert Collar........................................................................ 9 ‐ 10Open Extended Collar ................................................................... 9 ‐ 10
Internal Space Constraint for Third‐Party Camera ............................. 9 ‐ 10
Variant Details ‐ CEN, Standard Sleeve
Package Dimensions........................................................................... 10 ‐ 1
ATM Dimensions ................................................................................ 10 ‐ 1Without Pressurisation ................................................................. 10 ‐ 1With Pressurisation ....................................................................... 10 ‐ 1
Weights and Floor Loading................................................................. 10 ‐ 1Without Pressurisation ................................................................. 10 ‐ 1With Pressurisation ....................................................................... 10 ‐ 1
Collar Dimensions............................................................................... 10 ‐ 2Standard........................................................................................ 10 ‐ 2Advert............................................................................................ 10 ‐ 2Logo............................................................................................... 10 ‐ 2Open Standard .............................................................................. 10 ‐ 2Open Advert .................................................................................. 10 ‐ 2Open Extended.............................................................................. 10 ‐ 2
Cable Entry ......................................................................................... 10 ‐ 2
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Contents NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
ii
Security Bolts ......................................................................................10 ‐ 3Bolt Holes............................................................................................10 ‐ 3Standard, Advert, Logo or Open Advert Collar ..............................10 ‐ 3Open Standard or Open Extended Collar ......................................10 ‐ 3
Hole in the Wall ..................................................................................10 ‐ 4Hole at Optimum Height ...............................................................10 ‐ 4Hole at Lowered Height.................................................................10 ‐ 4
Facia Items..........................................................................................10 ‐ 5Topmost Viewable Facia Item .......................................................10 ‐ 5Heights and Depths .......................................................................10 ‐ 5Distance for Voice Guidance .........................................................10 ‐ 5
Servicing Areas ‐ Optimum ‐ Single ATM ............................................10 ‐ 6Standard, Advert, Logo or Open Advert Collar ..............................10 ‐ 6Open Standard or Open Extended Collar ......................................10 ‐ 6
Servicing Areas ‐ Optimum ‐ Side By Side...........................................10 ‐ 7Standard, Advert, Logo or Open Advert Collar ..............................10 ‐ 7Open Standard or Open Extended Collar ......................................10 ‐ 7
Servicing Areas ‐ Minimum ‐ Single ATM............................................10 ‐ 8Standard, Advert, Logo or Open Advert Collar ..............................10 ‐ 8Open Standard or Open Extended Collar ......................................10 ‐ 8
Servicing Areas ‐ Minimum ‐ Side By Side ..........................................10 ‐ 9Standard, Advert, Logo or Open Advert Collar ..............................10 ‐ 9Open Standard or Open Extended Collar ......................................10 ‐ 9
Clearances ‐ Corridor ........................................................................10 ‐ 10
Clearance ‐ Pressurisation Fan..........................................................10 ‐ 10
Clearances ‐ Exterior Wall.................................................................10 ‐ 10Standard, Open Standard or Logo Collar .....................................10 ‐ 10Advert Collar................................................................................10 ‐ 10Open Advert Collar ......................................................................10 ‐ 10Open Extended Collar..................................................................10 ‐ 10
Internal Space Constraint for Third‐Party Camera ...........................10 ‐ 10
Variant Details ‐ UL, Short SLeeve
Package Dimensions ...........................................................................11 ‐ 1
ATM Dimensions.................................................................................11 ‐ 1
Collar Dimensions ...............................................................................11 ‐ 1Standard ........................................................................................11 ‐ 1Advert ............................................................................................11 ‐ 1Logo ...............................................................................................11 ‐ 1Open Standard...............................................................................11 ‐ 1Open Advert ..................................................................................11 ‐ 1Open Extended ..............................................................................11 ‐ 1
Weight and Floor Loading...................................................................11 ‐ 2
Security Bolts ......................................................................................11 ‐ 2
Bolt Holes............................................................................................11 ‐ 2Standard, Advert, Logo or Open Advert Collar ..............................11 ‐ 2Open Standard or Open Extended Collar ......................................11 ‐ 2
Cable Entry..........................................................................................11 ‐ 2
Hole in the Wall ..................................................................................11 ‐ 3Hole at Optimum Height ...............................................................11 ‐ 3Hole at Lowered Height.................................................................11 ‐ 3
Facia Items..........................................................................................11 ‐ 4Topmost Viewable Facia Item .......................................................11 ‐ 4Heights and Depths .......................................................................11 ‐ 4Distance for Voice Guidance .........................................................11 ‐ 4
Servicing Areas ‐ Optimum ‐ Single ATM............................................11 ‐ 5Standard, Advert, Logo or Open Advert Collar..............................11 ‐ 5Open Standard or Open Extended Collar ......................................11 ‐ 5
Servicing Areas ‐ Optimum ‐ Side By Side...........................................11 ‐ 6Standard, Advert, Logo or Open Advert Collar..............................11 ‐ 6Open Standard or Open Extended Collar ......................................11 ‐ 6
Servicing Areas ‐ Minimum ‐ Single ATM............................................11 ‐ 7Standard, Advert, Logo or Open Advert Collar..............................11 ‐ 7Open Standard or Open Extended Collar ......................................11 ‐ 7
Servicing Areas ‐ Minimum ‐ Side By Side ..........................................11 ‐ 8Standard, Advert, Logo or Open Advert Collar..............................11 ‐ 8Open Standard or Open Extended Collar ......................................11 ‐ 8
Clearances ‐ Corridor..........................................................................11 ‐ 9
Clearances ‐ Exterior Wall ..................................................................11 ‐ 9Standard, Open Standard or Logo Collar.......................................11 ‐ 9Advert Collar..................................................................................11 ‐ 9Open Advert Collar ........................................................................11 ‐ 9Open Extended Collar....................................................................11 ‐ 9
Internal Space Constraint for Third‐Party Camera .............................11 ‐ 9
Variant Details ‐ UL, Standard SLeeve
Package Dimensions ...........................................................................12 ‐ 1
ATM Dimensions.................................................................................12 ‐ 1
Collar Dimensions...............................................................................12 ‐ 1Standard ........................................................................................12 ‐ 1Advert............................................................................................12 ‐ 1Logo ...............................................................................................12 ‐ 1Open Standard ..............................................................................12 ‐ 1Open Advert ..................................................................................12 ‐ 1Open Extended..............................................................................12 ‐ 1
Weight and Floor Loading ..................................................................12 ‐ 2
Security Bolts ......................................................................................12 ‐ 2
Bolt Holes ...........................................................................................12 ‐ 2Standard, Advert, Logo or Open Advert Collar..............................12 ‐ 2Open Standard or Open Extended Collar ......................................12 ‐ 2
Cable Entry .........................................................................................12 ‐ 2
Hole in the Wall ..................................................................................12 ‐ 3Hole at Optimum Height ...............................................................12 ‐ 3Hole at Lowered Height.................................................................12 ‐ 3
Facia Items..........................................................................................12 ‐ 4Topmost Viewable Facia Item .......................................................12 ‐ 4Heights and Depths .......................................................................12 ‐ 4Distance for Voice Guidance .........................................................12 ‐ 4
Servicing Areas ‐ Optimum ‐ Single ATM............................................12 ‐ 5Standard, Advert, Logo or Open Advert Collar..............................12 ‐ 5Open Standard or Open Extended Collar ......................................12 ‐ 5
Servicing Areas ‐ Optimum ‐ Side By Side...........................................12 ‐ 6
Standard, Advert, Logo or Open Advert Collar.............................. 12 ‐ 6Open Standard or Open Extended Collar ...................................... 12 ‐ 6
Servicing Areas ‐ Minimum ‐ Single ATM ........................................... 12 ‐ 7Standard, Advert, Logo or Open Advert Collar.............................. 12 ‐ 7Open Standard or Open Extended Collar ...................................... 12 ‐ 7
Servicing Areas ‐ Minimum ‐ Side By Side .......................................... 12 ‐ 8Standard, Advert, Logo or Open Advert Collar.............................. 12 ‐ 8Open Standard or Open Extended Collar ...................................... 12 ‐ 8
Clearances ‐ Corridor.......................................................................... 12 ‐ 9
Clearances ‐ Exterior Wall .................................................................. 12 ‐ 9Standard, Open Standard or Logo Collar....................................... 12 ‐ 9Advert Collar ................................................................................. 12 ‐ 9Open Advert Collar........................................................................ 12 ‐ 9Open Extended Collar ................................................................... 12 ‐ 9
Internal Space Constraint for Third‐Party Camera ............................. 12 ‐ 9
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
1 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationIntroduction
AUDIENCE
This document is intended for architects and those responsible for preparing a site prior to the arrival of the ATM.
ABOUT THIS DOCUMENT
This site preparation document is designed to be read on wide aspect ratio screens. Each section has been structured to fit the maximum amount of information on the minimum number of pages yet still be readable when printed on A3 size paper. Printing on smaller paper sizes may reduce readability but will make handling easier.
The document is organised into sections covering the following topics:
Introduction ‐ this section
Customer Responsibilities
Standards Compliance
Product Overview
Site Requirements
Power Requirements
Cable Requirements
Decals
Variant Details ‐ UL, Short Sleeve
Variant Details ‐ UL, Standard Sleeve
Variant Details ‐ CEN, Short Sleeve
Variant Details ‐ CEN, Standard Sleeve
Each page has two or three columns laid out as follows:
Where left and right side are stated the ATM is viewed from the front (facia side) of the ATM. All plan views are from the top unless otherwise stated.
Unless otherwise stated all dimensions are rounded to the nearest millimetre and equivalent decimal of an inch.
NCR SITE PREPARATION SERVICES CONTACT INFORMATION
For more information from NCR’s Site Preparation Services group on the availability of power protection, data line transient suppressors, uninterruptible power supply products, warranty or configuration assistance, call the appropriate number below:
REVISION RECORD
Publication IDCopyright
Publication name Section name Section number Page number
Column 1 Column 2 Column 3
Region Telephone
USA and Canada +1 800 257 0458
Europe, Middle East and Africa +97 1501405904 or 919-228-2412 (US)
Caribbean and Latin America +55 21 2540 0058
Asia Pacific +91 93-80291285
Date Revision Pages Reason for Change
November 2010 E Inside frontcover
Back pages8, 10, 12, 69
Various78
Various
Updated inside front cover EMC and NCR address. Added revision record.Contact information changed.Added CEN Grade IV ECB·S Security Enclosure
Added Scalable Deposit ModuleRemoved opaque window decal - not available on this productChanged ADA collar to Open Standard Collar
February 2011 F 4767
Various
Updated Lowered Heights section.Updated CEN IV walk-up weights and floor loading.Removed references to ECB·S and Spanish Certified. Updated ADA plinth heights. Removed ADAAG.
May 2011 G 67 Added CEN III and CEN IV gas resistant variants weights and floor loadings
June 2011 G 72 Note 2 changed to read hole ‘C’, was hole ‘B’
November 2011 G 24 Corrected Cheque Entry conversions
November 2011 H 48, 5153
Removed open standard collar from note 1.Removed word ADA from text.
April 2012 J 25, 26, 27, 29,30
Added Contactless Card Reader (behind Facia).
November 2012 K 13, 14, 19, 2049
76, 77
76
Added ATM dimensions with Pressurisation Fan.Added Height Clearance section.Added Floor Loading information with Pressurisation Fan. Corrected Gas Resistant UL floor loading information.
December 2012 L 817, 20, 22, 24
30, 313477
Added CEN III to Drive Up variants list.Added Drive Up ATM dimensions with CEN III.Added CEN III collar dimensions.Changed CEN L to CEN IIIAdded floor loading information of Drive Up variants with CEN III security enclosure.
March 2013 M All
Various9-3, 10-3,11-2, 12-2
New A3 landscape format.Removed all drive-up detail, this is now in a new publication B006-7206.Added all requirements from NCR SelfServ™ 32, 34, and 38 Site Preparation Requirements, B006-6670.Removed existing hole details.Updated security bolts specifications.
May 2013 N 9-1, 10-1 Added CENIII/IV dimensions
August 2013 P Various8-1
9-2, 10-5,11-4, 12-4
Various
Added the Open Extended Collar.Changed the heading title under advert window from Standard Collar with Advert Light or Lowered Height Collar to Advert Collar or Open Advert Collar.Changed the open standard width from 730 mm(28.74 in.) to 732 mm (28.82 in.).Updated the depths in the facia items section for all four variants, from front of collar to front of shelf.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
2 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationCustomer Responsibilities
NOTICE
This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully.
It is the responsibility of you, the customer, to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
CAUTION NCR Corporation is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.
SITE COMPLIANCE
This document contains the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified in this document, because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct.
Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer.
For information and guidance purposes only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation.
NCR staff will be available to answer questions relating to the contents of this document but, except where:
a. the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and
b. the customer shall have entered into a formal contract with NCR for provision of the same
no comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.
Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customer’s responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect, full insurance in respect of it.
CUSTOMER ACTIONS
The customer must do or provide the following:
When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate:
Location of the equipment
Site wiring (power and signal, paths and lengths)
Location of other equipment capable of generating electrical noise, electromagnetic interference, heat, etc.
Make building alterations necessary to meet wiring and other site requirements.
Provide and install all communications cables, wall jacks, special connectors, and associated hardware.
Provide and install necessary power distribution boxes, conduits, grounds, lightning protection, and associated hardware.
Make sure all applicable codes, regulations and laws (including, but not limited to, electrical, building, safety, and health) are met.
Provide and install auxiliary power or other equipment as required.
Provide storage or service areas as required.
Make sure the environmental requirements of the system/unit are met.
Provide floor coverings and environmental systems that limit or control static electricity build‐up and discharge.
Install the product at a height which meets the accessibility regulations of the relevant country.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
3 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationStandards Compliance
RADIO FREQUENCY INTERFERENCE
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case you, the customer, will be required to correct the interference at your own expense.
Canadian Class A Device Declaration
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
SAFETY
Safety Directive
73/23/EEC, 93/68/ECC ‘Low Voltage Directive and Amendment’.
Harmonised Safety Standard
EN 60950‐1: 2006 ‘Information Technology Equipment ‐ Safety’
ELECTROMAGNETIC COMPATIBILITY (EMC)
Immunity Standards
The ATM complies with the following requirements for radiated and conducted immunity:
EN 55024 (1998)/+A1: 2001, A2: 2003
As per the requirements of EN55024, the ATM complies with the requirements of the following normative Immunity Standard:
EN 61000‐4‐2 Electrostatic Discharge
EN 61000‐4‐3 Radiated RF
EN 61000‐4‐4 Electrical Fast Transient/Burst
EN 61000‐4‐5 Surge
EN 61000‐4‐6 Conducted RF
EN 61000‐4‐8 Power Frequency Magnetic Field
EN 61000‐4‐11 Voltage Dips/Short Interruption.
EMC Directives
This equipment has been found to comply with the essential requirements of EMC Directive 2004/108/EC, by testing to harmonized standard, EN55022and EN55024. The equipment complies with the limits for a Class A digital device, pursuant to EN55022.
The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:
2004/108/EC ‘EMC Directive’
93/68/EEC ‘CE Marking Directive’
Emission Standards
The ATM complies with the following requirements for radiated and conducted emissions:
EN 55022 (1998) Class A
FCC 47CFR Part 15. Class A
CISPR 22 Class A
AS/NZS 3548 Class A
GB 9254 Class A
CNS 13438 Class A.
Additional Requirements for 220V ‐ 240V Units
The ATM complies with the following requirements for conducted emissions:
EN 61000‐3‐2: 2000, Mains harmonics, Class A
EN 61000‐3‐3: 1995/+A1: 2001, Mains flicker.
ACCESSIBILITY
NCR Optimum Height
This height assures the best display viewability for able‐bodied people. It does NOT comply with the lowered height regulations listed in the next section.
Lowered Heights
The lowered installation heights are designed to meet the regulations below and therefore accommodate use by both able‐bodied and disabled people.
Lowered heights are specified for the following regulations:
(UK) Access to ATMs: UK Design Guidelines 2002, Centre for Accessible Environments
(US) Department of Justice Standard for Accessible Design, Title III, (ADA 2010)
(CAN) CAN/CSA B651.1‐09 Barrier‐Free Design for Automated Banking Machines (CSA).
In addition to CAE, ADA and CSA, the ATM is designed to also meet the following regulations:
(AUS) AS3769 Australian Standard (AS3769).
(AUS) Australian Bankers’ Association (ABA) Industry Standard, Automatic Teller Machines (ATMs).2004
(FRA) Ministère de L’Emploi, de la Cohésion Sociale et du Logement, Aug 24, 2006, which modifies Code de la Construction, articles R.111‐19 to R.111‐19‐3 and R.111‐19‐6
The heights listed in this document assume no additional depth has been added by the installation. Increased depth may change the height requirements, therefore please refer to the relevant accessibility regulation where additional depth has been added.
Note: It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations.
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
4 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationProduct Overview
GENERAL DESCRIPTION
The NCR SelfServ 34 Walk‐Up Automated Teller Machine is a ‘through the wall’ ATM which may be installed through any suitable exterior wall or in a vestibule location.
There are no separate Vestibule or Through the Wall variants of the SelfServ 34. All dimensions and clearances are the same for both types of installation.
Options
Security Enclosure
CEN Grade L
CEN Grade I
CEN Grade III
CEN Grade IV
UL 291 Level 1
Sleeve
Short Sleeve
Standard Sleeve
Collars
Standard
Advert
Logo
Open Standard
Open Advert
Open Extended
Pressurisation
Pressurisation fan (CEN variants only)
ACOUSTICS
For most variants the acoustics sound power does not exceed:
65 dB(A) when idle
68 dB(A) when operating (see note).
However, the following configurations will affect the sound levels as shown in the table below:
HEAT DISSIPATION
The NCR SelfServ product range is a flexible hardware platform. NCR recommends that actual power measurements are taken and used to establish the heat dissipation for specific hardware configurations. These measurements should include any custom or third party features.
Where specific measurements are not available then, as a guide, 760 KJ/hour can be used as an indicative heating load. This figure is based on an ATM in idle mode, with a medium to high feature functionality configuration.
Heat dissipation figures are largely unaffected by transactional rates.
PRODUCT IDENTIFICATION
The illustration below is typical of the layout of the product identification label which is fixed inside the ATM.
The product is identified by a class and a 4 digit model number. The serial number is unique to each ATM. The tracer number is used to identify where the ATM was built.
Please quote all of the serial and tracer numbers, including the prefix, when making reference to the ATM.
Electrical rating information is also shown on the product label.
Configuration Acoustic sound power when operating
Coin and passbook does not exceed 72 dB(A)
Cooling fans does not exceed 75 dB(A)
Air conditioner does not exceed 78 dB(A)
Model: XXXX
Hz: 50/60 A: X.X
XX - XXXXXXXXTracer: Serial:
Vãc:
NCR Global Solutions Ltd.
NCR SelfServ XX™
Made in UK
BANK EQUIPMENTCLASSIFIED BY UNDERWRITERSLABORATORIES INC. AS TOELECTRICAL FIRE, SHOCK ANDCASUALTY HAZARDS ONLY.5B3R
CLASSIFIED
Electromagnetic CompatibilityThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.
This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio InterferenceRegulations of Canada.
Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J
Class: XXXX
XX - XX
®LR32207
ACN 000 003 592Manufactured: Xxxxxx XXXX
®UL
XXX - XXXv
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables auxappareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par leministère des Communications du Canada
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
5 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationSite Requirements
POSITIONING THE ATM
The ATM may be installed through any suitable exterior wall or vestibule location.
The ATM must also be positioned away from heat sources or any air conditioning equipment.
Bright lights and windows behind the user may degrade camera performance. Position the ATM away from direct sunlight.
Allow sufficient room for installation and servicing requirements.
FLOOR
The ATM must be installed on a level, even, concrete or other noncombustible surface. In locations where the floor may be uneven, it is recommended that a steel plate is used under the ATM.
An antistatic floor covering should be used and must be of a type that will not generate dust or fluff.
The ATM must be installed on a floor capable of supporting the maximum weight including media. Only the maximum weight should be considered as additional options may be added after installation. Floor loading is calculated by dividing the maximum weight of the ATM by the surface area of the ATM base in contact with the floor.
Service areas, ATM weights and floor loading can be found in the Variant Details section for your ATM.
DOORWAYS AND CORRIDORS
Make sure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM and remove it from the palette in an area with sufficient access then move it to the installation site.
Make sure that any corridors can support the weight of the ATM, including all packaging and the pallet.
Corridor sizes and ATM weights can be found in the Variant Details section for your ATM.
WALL
A 25 mm (1.0 in.) wide smooth surface is required around the edge of the wall opening to enable a good weather seal.
Wall Cavity
Any cavity in the wall must be sealed to provide a flush surface that does not extend into the wall opening. Leave the gap between the ATM sleeve and the wall opening clear to allow air at room temperature to circulate.
Installing Through a Glass Wall
If you are installing your ATM through a glass wall you may require a suitable glass support (normally a steel collar) to sit between the ATM collar and the glass. The requirement for this support should be determined by the architect. If required, any such support should be sourced locally.
Collar Tolerance
The collar has a tolerance of +/‐ 4 mm (0.2 in. (+/‐ 0.5°)) at the top and bottom, with 0 mm (0.0 in. (0°)) at its centre.
The collar cannot accommodate large dips or depressions in the wall. Make sure the wall is smooth and even.
AMBIENT LIGHTING
If the ATM is fitted with a camera, it is strongly recommended that there is a minimum of 50 LUX lighting at floor level within the area illustrated below.
Seal any cavity
Do not block air gaps
+/- 4 mm(0.16 in.)
+/- 4 mm(0.16 in.)
0.0 mm(0.0 in.)
1500 mm(59.1 in.)
1000 mm(39.4 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Site Requirements NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
5 ‐ 2
TEMPERATURE AND HUMIDITY
Continuous operating at or near the range limits, or in a location where the temperature and humidity change beyond the specification, should be avoided.
If installing though an exterior wall, the site must meet the requirements of both the Interior and Exterior environments.
Note: For exterior through the wall ATMs the humidity inside the building is restricted to a maximum of 30% at an outside temperature of ‐35°C(‐31°F), with a linear relationship between temperature and humidity to a maximum humidity at 0°C (32°F).
Normal Operating Range (Interior Environment)
Temperature:
without Severe Environment: 10oC to 40oC (50oF to 104oF)
with severe environment fitted: 0oC to 40oC (32oF to 104oF)
Relative Humidity: 20% to 80%
Dew Point Temperature Restriction: 26oC (79oF) maximum
If a pressurisation unit is fitted then minimum operating temperature is 10oC (50oF) even with severe environment fitted.
Normal Operating Range (Exterior Environment)
Temperature:
without Passbook Printer: ‐35oC to 50oC (‐31oF to 122oF)
with Passbook Printer: 0oC to 40oC (32oF to 104oF)
Relative Humidity:
without Passbook Printer: 10% to 100%
with Passbook Printer fitted: 10% to 80%
Dew Point Temperature Restriction: 26oC (79oF) maximum
If a pressurisation unit is fitted then minimum operating temperature is 10oC (50oF) even with severe environment fitted.
Storage Range (Up To Three Months)
Temperature: ‐10oC to 50oC (14oF to 122oF)
Relative Humidity: 10% to 90%
Transit Range (Up To One Week)
Temperature: ‐40oC to 60oC (‐40oF to 140oF)
Relative Humidity: 5% to 95%
Extreme Power On Range (Up To One Hour)
Temperature: 0oC to 45oC (32oF to 113oF)
Relative Humidity: 10% to 95%
BAROMETRIC PRESSURE
Operating/Transit Limits: 105 kPa (15.2 lb.F/in.) to 70 kPa (10.2 lb.F/in.)
Equivalent Altitude: Up to a maximum of 3000 m (9842.52 ft)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
6 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationPower Requirements
AC POWER REQUIREMENTS
The maximum current requirements are:
10A at 120V
6.3A at 230V.
The maximum inrush current is 100A.
NCR does not recommend running an ATM with deposit devices without an Uninterruptible Power Supply (UPS). Without a UPS, there is the potential for customer’s cash to be retained in the device if there is a power failure.
INPUT VOLTAGE SETTING
The ATM can operate from the following input mains voltages:
90V to 136V at 50/60Hz
180V to 264V at 50/60Hz.
GROUNDING
The ATM operates from a single phase, 3 wire supply: live, neutral and ground.
The ATM power requirements will normally permit it to operate within existing wiring configurations and from existing mains outlets provided that:
the branch circuit of the distribution panel supporting the ATM is not also used to support equipment with heavy inductive loads such as air conditioners or AC motors.
other branch circuits on the same distribution panel do not support such equipment.
the installation meets or exceeds the regulatory and local guidelines with regard to electrical safety and all conductor sizing.
The normal and safe operation of this ATM is dependant on the above. Only qualified personnel that meet local certification standards should be permitted to ensure compliance.
Note that the building ground point can also affect data integrity. For additional information refer to Data Line Transient Protection in the Cable Requirements section
TRANSIENT PROTECTION
In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced on to power lines. Such transient energy can be very damaging to electronic hardware and can also cause data corruption. Under these circumstances, NCR recommends the use of AC power transient suppressors and data (communication) line transient suppressors. Such protective devices are intended to guard against power and data line transients that can result in hardware damage and various system or program errors.
Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by NCR Corporation Maintenance Agreement. NCR accepts no liability for any such occurrence nor for its consequences.
When power transient suppression is required, the suppressors used should meet the following minimum requirements:
Dissipate energy to match the appropriate application categories as defined by ANSI/IEEE Standard C62.41, Guide on Surge Voltages in Low‐Voltage AC Power Circuits.
Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not ‘clamp’ the voltage to zero, and must self‐recover after the passage of the transient. The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements.
Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive indication of its failure such as a blown fuse or tripped breaker
Be listed by the accepted safety organization for the country involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, state, and national electrical codes and regulations.
Transient Protection Products
NCR provides a full range of both AC power and data line transient surge suppressors to protect your ATM. For more information, please call NCR Site Preparation Services for more information.
NCR Site Preparation Services Contact Information is listed in the Introduction section.
Location CategoryComparable to IECNo 664 Category
Transient
Waveform Amplitudes
B = Major feeders, short branch circuits, and load centres
III
Volts = 1.2 x 50 sCurrent = 8 x 20 sand0.5 Rise - 100 kHz Ringwave
6kV3kA
6kV500A
C = Service Entrance and run to load centre
IVVolts = 1.2 x 50 sCurrent = 8 x 20 s
10kV or more10kA or more
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
7 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationCable Requirements
CABLE PREPARATION
NCR supply a power cable for the ATM. Other external cables are not supplied. Specifications for these cables are given in this section.
It is the customer’s responsibility to have any required external cables installed and to make sure that all cable preparations comply with NCR specifications as well as with all national, state or local telephone and telegraph regulations and laws.
When producing cables allow for 2.2 m (7.22 ft) of cable within the ATM.
DATA LINE TRANSIENT PROTECTION
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur the use of protective devices may be required to ensure proper operation of the equipment.
It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements:
Be of the self‐recovering voltage limiting type. Exhibit a ‘short circuit’ mode upon its failure to ensure a positive indication of its failure. Insert minimum inductive and capacity loading at the operating frequency. Be installed in accordance with all applicable local, state, and national electrical codes and regulations.
Protect the data port from damage in the presence of a data line transient event as defined in IEC Standard 1000‐4‐5 (formerly IEC 801‐5).
Transient Protection Products
NCR provides a full range of both AC power and data line transient surge suppressors to protect your ATM. For more information, please call NCR Site Preparation Services for more information.
NCR Site Preparation Services Contact Information is listed in the Introduction section.
HIGH ORDER COMMUNICATIONS STANDARD CABLE (RS‐232)
The interconnecting cable to the remote modem should not exceed 12.24 m (40.16 ft) in length and must conform to the following specification:
Remove a 40 mm (1.57 in.) section of the outer sleeve, 1.5 m (4.9 ft.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
RS‐232 CABLE (9 PIN)
The ATM can have up to two RS‐232 (9 pin) outlets. The cable for each outlet should not exceed 12.24 m (40.16 ft) and must conform to the following specification:
Remove a 40 mm (1.57 in.) section of the outer sleeve, 2 m (6.6 ft.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1, 2, 5, 6
3
4
1. Connector, 25 Way (NCR part no. 006-0005897)2. Terminal, wire, male (NCR part no. 009-0002642)3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
RD.V
DSR.V
RFS.V
SIG.GND
RLSD.V
WCA.V
DTR.V
CI.V
WIN.V
TD.V
RQS.V
TSET.V
RSET.V
EXT SET.V
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
1.5 m(4.9 ft.)
40 mm(1.57 in.)
1
2
3
4
5
6
7
8
9
1, 23
4
DCD
TXD
DSR
S-GND
RTS
CTS
RI
RXD
DTR
1. Connector, 9 way (NCR part no. 006-0010488).2. Terminal wire, female (NCR part no. 009-0002640).3. Cable, shielded multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).
40 mm(1.57 in.)
2 m(6.6 ft.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Cable Requirements NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
7 ‐ 2
ALARM INTERFACE CABLES
The ATM may optionally be configured to provide an alarm interface which enables the ATM to be connected to an external local alarm system. The interface may take the form of one of two options; a basic alarm system or an enhanced alarm system.
A stabilised, non‐interruptible power supply must be provided through the external alarm system. The alarm interface cable wiring must conform to the following specification:
12V +/‐ 2V dc
200mA maximum
Ripple, 5% maximum.
Basic Alarm Cable
Remove a 20 mm (0.8 in.) section of the outer sleeve, 125 mm (4.9 in.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
Enhanced Alarm Cable
Remove a 20 mm (0.8 in.) section of the outer sleeve, 125 mm (4.9 in.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1, 2, 5, 6
3
4
1. Connector, 25 Way (NCR part no. 006-0005896)2. Terminal, wire, female (NCR part no. 009-0002640)3. Cable, multiconductor (determined by the alarm installed).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Common
+12V
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
N.O.
N.C
+12V Return
Vibration/Heat
Vibration/Heat
Vibration/Heat
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm(0.8 in.)
125 mm(4.9 in.)
1, 2, 5, 6
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1. Connector, 25 Way (NCR part no. 006-0005896)2. Terminal, wire, female (NCR part no. 009-0002640)3. Cable, multiconductor (determined by the alarm installed).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Test Transmitter A
Tamper Alarm N.O.
Tamper Alarm N.C
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Composite Attack Common
+12V
Test Transmitter B
Tamper Alarm Common
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
Composite Attack N.O.
Composite Attack N.C
+12V Return
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm(0.8 in.)
125 mm(4.9 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Cable Requirements NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
7 ‐ 3
REMOTE STATUS MONITOR
The remote status monitor feature is supplied as a complete assembly consisting of a status indicator unit, 76.2 m (250 ft) of cable and a connector.
Remove a 20 mm (0.8 in.) section of the outer sleeve, 125 mm (4.9 in.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
Shortening the Cable
If you need to shorten the cable, proceed as follows:
1. Remove the cover from the remote status indicator unit
2. Disconnect the four leads (E1, E2, E3 and E4) from the indicator
3. Cut the cable to the required length and strip the four wire ends
4. Connect the wires to the correct terminals
5. Replace the status indicator cover.
REMOTE RELAY CABLE
The remote relay provides a pair of open contacts, rated at 28 volts per ampere for both ac and dc supplies, which can be closed to activate a remote device. The interconnecting cable to a remote device must conform to the following specification and wiring:
Remove a 20 mm (0.8 in.) section of the outer sleeve, 125 mm (4.9 in.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
ETHERNET STANDARD CABLE
The ethernet standard cable must be fully shielded, 8 pin, category 5 compliant and must not exceed 97 m (318.20 ft) in length.
Remove a 40 mm (1.57 in.) section of the outer sleeve, 1.8 m (5.91 ft.) from the ATM end of the cable.
Take care not to cut through the cable shielding.
POWER CABLE
The ATM is supplied either as a 120V or a 220‐240V unit.
120V ATMs are supplied with a power cable fitted with a NEMA type 5‐15P power source connector.
220‐240V ATMs are supplied with an unterminated power cable. Information about suitable power connectors is supplied with the accessories.
The power cable supplied is 3 m (9.84 ft) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations.
WARNING This equipment must be earthed.
125 mm(4.9 in.)
20 mm(0.8 in.)
(Green) E1
(Red) E2
(White) E3
(Black) E4
Red
Yellow
Green
1
2
1, 2 34
Rl1
RL2
1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).2. Terminal wire, male (NCR part no. 007-2009663).3. Cable, multiconductor (NCR part no. 006-5800006).4. Connector (determined by remote device).
20 mm(0.8 in.)
125 mm(4.9 in.)
40 mm(1.57 in.)
1.8 m(5.91ft.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
8 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationDecals
CARD ORIENTATION WINDOW
An industry standard credit card can be placed behind the card orientation window.
The card or decal should be a maximum of 0.75 mm (0.0295 in.) thick.
Note: Not suitable for use with the contactless card reader.
ADVERT WINDOW
The decals should be a maximum of 0.75 mm (0.0295 in.) thick.
Logo Collar
Advert Collar or Open Advert Collar
CASH BLANK WINDOW
The card or decal should be a maximum of 0.75 mm (0.0295 in.) thick.
ENTRY/EXIT DECALS
Entry/Exit decals should be a maximum of 0.5 mm (0.02 in.) thick. NCR recommends they be made from textured polycarbonate with 3M 467 High Performance MP adhesive.
Decals should provide good contrast, at least 70%, between foreground (text/icon) and background.
A sans serif typeface should be used (Tiresias is recommended). The text size should be at least 14 point, and larger where possible. Where tactile decals are required they should be designed in line with specific country requirements.
Suggested icon designs and wording are shown below:
DECAL PLACEMENT
NCR recommends placing entry/exit decals above or below the entry/exit slots, determined by the space available near the slot.
Cash Blank Window decal and Card Orientation Window decal/card are placed on the inside of the window.
Advert window decals can be placed on either the front or the inside of the window.
15 mm(0.59 in.)
48 mm(1.89 in.)Radius
54 mm(2.13 in.)
86 mm(3.39 in.)
530 mm(20.87 in.)
58mm(2.28 in.)
483 mm(19.02 in.)
2.5 mm(0.09 in.)Radius in
four corners
168 mm(6.61 in.)
251 mm(9.88 in.)
67 mm(2.64 in.)
0.5 mm(0.02 in.)Radius in
four corners
Envelope Deposit
Statement and
Passbook Printer
Statement
Cash Deposit
Cash DispenseReceipt
CashDispense/Deposit
EnvelopeDispense/Deposit
Envelope Deposit
Cheque Deposit
12
34
56
78
9
Passbook Printer
Coin Dispense
Finger Print Reader
Cash/ChequeDeposit1
23
4 5
67
8 9
12 mm(0.47 in.)
70 mm(2.76 in.)
Advert Window
Card OrientationWindow
Cash BlankWindow
Coin
Cash Deposit
Passbook
FingerprintReader
Receipt
Statement
Cash/Cheque Depositor
Envelope Depositor
Cash Dispense/Depositor
Envelope Dispense/Depositor
Cash Dispense
Cash/Cheque DepositorEnvelope DepositorCash Dispense/DepositorEnvelope Dispense/DepositorCash Dispense
Cheque Depositor
Bulk Cheque Deposit
Combined Statement/Passbook Printer
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
9 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationVariant Details ‐ CEN, Short SLeeve
PACKAGE DIMENSIONS
ATM DIMENSIONS
Without Pressurisation
With Pressurisation WEIGHTS AND FLOOR LOADING
Without Pressurisation
Standard Security Enclosures
Gas Resistant Security Enclosures
With Pressurisation
Standard Security Enclosures
Gas Resistant Security Enclosures
957 mm(37.68 in.)
977 mm(38.46 in.)
1405 mm(55.24 in.)
1435 mm(56.50 in.)
1836 mm(72.28 in.)
1702 mm(67.01 in.)
47 mm(1.85 in.)
267 mm(10.51 in.)
267 mm(10.51 in.)
1187 mm(46.73 in.)
1498 mm(58.98 in.)
868 mm(34.17 in.)
659 mm(25.94 in.)
843 mm(33.19 in.)
1171 mm(46.10 in.)
664 mm(26.14 in.)
800 mm(31.50 in.)
65 mm(2.56 in.)
605 mm(23.82 in.)
65 mm(2.56 in.)
773 mm(30.43 in.)
770 mm(30.31 in.)
CENI/L
CENIII/IV(34.84 in.)885 mm
865 mm (34.06 in.)
773 mm(30.43 in.)
47 mm(1.85 in.)
267 mm(10.51 in.)
280 mm(11.0 in.)
359 mm(14.13 in.)
134 mm(5.28 in.)
1187 mm(46.73 in.)
1641 mm(64.61 in.)
868 mm(34.17 in.)
659 mm(25.94 in.)
843 mm(33.19 in.)
1171 mm(46.10 in.)
664 mm(26.14 in.)
800 mm(31.50 in.)
65 mm(2.56 in.)
605 mm(23.82 in.)
65 mm(2.56 in.)
658 mm(25.91 in.)
143 mm(5.63 in.)
168 mm(6.61 in.)
42 mm(1.65 in.)
267 mm(10.51 in.)
770 mm(30.31 in.)
CENI/L
CENIII/IV(34.84 in.)
865 mm (34.06 in.)
885 mm
CEN Grade I and CEN Grade L
CEN grade III CEN grade IV
Maximum weight878 kg
(1935 lb.)1036 kg(2285 lb.)
1076 kg(2372 lb.)
Floor loading1425 kg/m2 (292 lb./ft2)
1682 kg/m2 (345 lb./ft2)
1747 kg/m2 (358 lb./ft2)
CEN grade III CEN grade IV
Maximum weight1060 kg
(2336.9 lb.)1101 kg
(2427.3 lb.)
Floor loading1721 kg/m2 (352.4 lb./ft2)
1787 kg/m2 (366.0 lb./ft2)
CEN Grade I and CEN Grade L
CEN grade III CEN grade IV
Maximum weight888 kg
(1957.7 lb.)1046 kg
(2306 lb.)1086 kg
(2394.2 lb.)
Floor loading1442 kg/m2 (295.2 lb./ft2)
1698 kg/m2 (347.8 lb./ft2)
1763 kg/m2 (361.1 lb./ft2)
CEN grade III CEN grade IV
Maximum weight1070 kg
(2358.9 lb.)1111 kg
(2449.3 lb.)
Floor loading1737 kg/m2 (355.7 lb./ft2)
1804 kg/m2 (369.4 lb./ft2)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 2
COLLAR DIMENSIONS
Standard
Advert
Logo
Open Standard
Open Advert
Open Extended
CABLE ENTRY
38 mm(1.49 in.)
75 mm(2.95 in.)
626 mm(24.6 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1233 mm(48.54 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
75 mm(2.94 in.)
840 mm(33.07 in.)
276 mm(10.87 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1447 mm(56.97 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
626 mm(24.65 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1233 mm(48.54 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
630 mm(24.80 in.)
60 mm(2.36 in.)
37 mm(1.46 in.)
129 mm(5.08 in.)
732 mm(28.82 in.)
1234 mm(48.58 in.)
185 mm(7.28 in.)
38 mm(1.49 in.)
855 mm(33.66 in.)
210 mm(8.27 in.)
291 mm(11.57 in.)
47 mm(1.85 in.)
75 mm(2.95 in.)
725 mm(28.54 in.)
1462 mm(57.56 in.)
239 mm(9.41 in.)
185 mm(7.28 in.)
38 mm(1.50 in.)
60 mm(2.36 in.)
129 mm(5.08 in.)
859 mm(33.82 in.)
37 mm(1.46 in.)
732 mm(28.82 in.)
1234 mm(48.58 in.)
535 mm(21.1 in.)
170 mm(6.7 in.)
770 mm(30.31 in.)
800 mm(31.50 in.)
150 mm(5.91 in.)
403 mm(15.87 in.)
247 mm(9.72 in.)
33 mm(1.30 in.)
65 mm(2.66 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 3
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of the bolt holes, using bolts with anchor washers as specified below. Bolts and anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading imposed by the anchor points for these bolts.
If an adjustable plinth is used, it must be bolted to the floor to the same specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a concrete floor is:
Bolts
Type ‐ either resin anchor or shield anchor bolts
Size ‐ M16 (5/8 in.)
Minimum Length ‐ 150 mm (5.9 in.)
Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
Type ‐ flat, steel (as per DIN7349 or equivalent)
Size ‐ M16 (5/8 in.)
Outer diameter ‐ no greater than 40 mm (1.58 in.)
Minimum thickness ‐ 6 mm (0.2 in.).
BOLT HOLES
The ATM should be bolted to the floor or plinth, through all the holes marked ‘A’, using four bolts with anchor washers.
The ‘B’ hole enables an alarm to be fitted (CEN III security enclosures only).
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
203 mm (8.00 in.)Maximum
384 mm(15.12 in.)
B
A
A
A
A
Hole in Wall
500 mm(19.7 in.)
250 mm(9.8 in.)
285 mm(11.2 in.)
770 mm(30.3 in.)
170 mm(6.7 in.)
800 mm(31.5 in.)
150 mm(5.9 in.)
500 mm(19.7 in.)
250 mm(9.8 in.)
150 mm(5.9 in.)
19 mm(0.7 in.)
Hole A Bolt Holes (All CEN security enclosures) Hole B (Alarm Hole, CEN III security enclosures only)
45 mm(1.77 in.)
45 mm(1.77 in.)
20 mm(0.78 in.)
25 mm(0.98 in.)
28 mm(1.10 in.)
60 mm(2.36 in.)
45 mm(1.77 in.)
28 mm(1.10 in.)
B
A
A
A
A
Hole in Wall
Hole A Bolt Holes (All CEN security enclosures) Hole B (Alarm Hole, CEN III security enclosures only)
178 mm (7.00 in.)Maximum
330 mm(12.99 in.)
500 mm(19.68 in.)
250 mm(9.84 in.)
285 mm(11.22 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
150 mm(5.91 in.)
500 mm(19.68 in.)
250 mm(9.84 in.)
150 mm(5.91 in.)
19 mm(0.75 in.)
45 mm(1.77 in.)
45 mm(1.77 in.)
20 mm(0.78 in.)
25 mm(0.98 in.)
28 mm(1.10 in.)
60 mm(2.36 in.)
45 mm(1.77 in.)
28 mm(1.10 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 4
HOLE IN THE WALL
Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations. Where no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have the height specified in the illustrations below.
The open advert collar does not fit through this hole.
Standard, Advert or Logo Collar
Open Standard Collar
Hole at Lowered Height
It is the responsibility of the owning institution to make sure that the heights from the sidewalk level to the facia items comply with any local regulations.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have one of the heights specified in the table below.
Note that CEN certified security enclosures must have a CEN certified plinth.
NCR recommends the Open Standard or Open Advert Collar for lowered height installation.
Open Advert Collar
Open Standard or Open Extended Collar
View from Inside BuildingMaximum (8.00 in.)203 mm
534 mm(21.02 in.)
Plinth
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
368 mm(14.49 in.)
368 mm(14.49 in.)
View from Inside BuildingMaximum (7.00 in.)178 mm
534 mm(21.02 in.)
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
Plinth
Installation Height
CAEParallel Approach
ADACSA
Parallel Approach
A - Bottom of hole816 mm
(32.13 in.)786 mm
(30.94 in.)766 mm
(30.16 in.)
B - Plinth height168 mm(6.61 in.)
138 mm(5.43 in.)
118 mm(4.65 in.)
Maximum (8.00 in.)203 mm
744 mm(29.29 in.)
A
B
19 mm(0.7 5in.)
625 mm(24.61 in.)
Hole in Wall
ATM Base
View from Inside Building
PlinthSidewalk
View from Inside BuildingMaximum (7.01 in.)178 mm
534 mm(21.02 in.)
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
A
B
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 5
FACIA ITEMS
Topmost Viewable Facia Item
Depending on the configuration of the ATM the statement exit slot or the cheque entry slot may be the highest viewable facia item.
The following table shows the projected angles (‘A’ in the illustration) from the front of the collar to the topmost viewable facia item for the different collar types. The illustration shows the Standard collar.
Heights and Depths Distance for Voice Guidance
Standard or Advert Collar
Open Standard or Open Extended Collar
Open Advert Collar
Statement Exit 27 degrees 34 degrees 40 degrees
Cheque Entry 44 degrees 60 degrees 66 degrees
5JKL
$
S
12
34
56
78
9
S
12
34
56
78
9
A
Facia ItemHeight
from baseof ATM
Depthfrom front
of shelf
Statement Exit1079 mm(42.48 in.)
245 mm(9.64 in.)
Passbook Entry/Exit1079 mm(42.48 in.)
245 mm(9.64 in.)
Receipt1079 mm(42.48 in.)
155 mm(6.10 in.)
Cheque Entry1060 mm(41.73 in.)
185 mm(7.28 in.)
Coin Exit1074 mm(42.28 in.)
206 mm(8.11 in.)
Touchscreen381 mm (15.0 in.)
Top1029 mm(40.51 in.)
258 mm(10.16 in.)
Touchscreen307 mm (12.1 in.)
Top1008 mm(39.68 in.)
252 mm(9.92 in.)
Display with FDKs381 mm (15.0 in.) Display
Top FDK961 mm
(37.83 in.)206 mm(8.11 in.)
Card Reader958 mm
(37.72 in.)125 mm(4.92 in.)
Display with FDKs307 mm (12.1 in.) Display
Top FDK954 mm
(37.56 in.)201 mm(7.91 in.)
Contactless Card Reader (on Facia)883 mm(34.76 in.
106 mm(4.17 in.)
Camera874 mm
(34.41 in.)121 mm(4.76 in.)
Private Audio824 mm
(32.44 in.)119 mm(4.68 in.)
Cash Exit/Entry749 mm
(29.49 in.)137 mm(5.39 in.)
Envelope Exit/Entry749 mm
(29.49 in.)137 mm(5.39 in.)
Scalable Deposit Module749 mm
(29.49 in.)137 mm(5.39 in.)
Fingerprint Reader733 mm
(28.86 in.)59 mm
(2.32 in.)
Contactless Card Reader (behind Facia)714 mm
(28.11 in.)80 mm
(3.14 in.)
PIN Pad Number 5 key714 mm
(28.11 in.)69 mm
(2.72 in.)
$
S
12
34
56
78
9
5JKL
Facia ItemDistance from
No. 5 Key
Receipt 1446 mm
(17.56 in.)
Card Reader 1355 mm
(13.98 in.)
Contactless Card Reader(on Facia)
2296 mm
(11.65 in.)
Private Audio 2264 mm
(10.39 in.)
Cash Exit/Entry 3184 mm(7.24 in.)
Envelope Exit/Entry 3184 mm(7.24 in.)
Contactless Card Reader (behind Facia) 3242 mm(9.53 in.)
Fingerprint Reader 9217 mm(8.54 in.)
Cash Exit/Entry 9144 mm(5.67 in.)
Envelope Exit/Entry 9144 mm(5.67 in.)
Scalable Deposit Module 9144 mm(5.67 in.)
Display with FDKs307 mm (12.1 in.) Display
Top Left FDK
10306 mm
(12.05 in.)
Display with FDKs381 mm (15.0 in.) Display
Top Left FDK
10333 mm
(13.11 in.)
Cheque Entry 11426 mm
(16.77 in.)
Coin Exit 11426 mm
(16.77 in.)
Statement Exit 12378 mm
(14.88 in.)
Passbook Entry/Exit 12378 mm
(14.88 in.)
12111098
7 6 543
21
S
S
12
34
56
78
9
$
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 6
SERVICING AREAS ‐ OPTIMUM ‐ SINGLE ATM
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2314 mm(91.10 in.)
178 mm(7.00 in.)Maximum
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 7
SERVICING AREAS ‐ OPTIMUM ‐ SIDE BY SIDE
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2368 mm(93.23 in.)
178 mm(7.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 8
SERVICING AREAS ‐ MINIMUM ‐ SINGLE ATM
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
2042 mm(80.39 in.)
326 mm(12.83 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
750 mm(29.53 in.)
2314 mm(91.10 in.)
178 mm(7.00 in.
)Maximum
1988 mm(78.27 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 9
SERVICING AREAS ‐ MINIMUM ‐ SIDE BY SIDE
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
2042 mm(80.39 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
178 mm(7.00 in.)Maximum
2314 mm(91.10 in.) 1988 mm
(78.27 in.)
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
9 ‐ 10
CLEARANCES ‐ CORRIDOR
The dimensions shown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
CLEARANCE ‐ PRESSURISATION FAN
The illustration below shows the minimum height clearance required for the installation, removal, and replacement of the pressurisation fan module.
CLEARANCES ‐ EXTERIOR WALL
Standard, Open Standard or Logo Collar
Advert Collar
Open Advert Collar
Open Extended Collar
INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA
If a third‐party camera is to be installed, it must fit within the space constraint shown below.
Packaged ATM(pallet, carton
and lid)
Packaged ATM(pallet and
carton)
Unpackaged ATM
A Doorway or straight corridor989 mm
(38.94 in.)969 mm
(38.15 in.)785 mm
(30.91 in.)
B Corridor with corner1224 mm(48.19 in.)
1199 mm(47.20 in.)
986 mm(38.82 in.)
C Rotation about centre1748 mm(68.82 in.)
1712 mm(67.40 in.)
1428 mm(56.22 in.)
C
B
BA
350 mm(13.78 in.)493 mm
(19.41 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
100 mm(3.94 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
56º
60 mm(2.36 in.)
30 mm(1.81 in.)
60 mm(2.36 in.)
30 mm(1.81 in.)
150 mm(5.90 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
10 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationVariant Details ‐ CEN, Standard Sleeve
PACKAGE DIMENSIONS
ATM DIMENSIONS
Without Pressurisation
With Pressurisation WEIGHTS AND FLOOR LOADING
Without Pressurisation
Standard Security Enclosures
Gas Resistant Security Enclosures
With Pressurisation
Standard Security Enclosures
Gas Resistant Security Enclosures
957 mm(37.68 in.)
977 mm(38.46 in.)
1405 mm(55.24 in.)
1435 mm(56.50 in.)
1836 mm(72.28 in.)
1702 mm(67.01 in.)
47 mm(1.9 in.)
380 mm(15.0 in.)
1300 mm(51.2 in.)
1498 mm(59.0 in.)
868 mm(34.2 in.)
659 mm(25.9 in.)
843 mm(33.2 in.)
1171 mm(46.1 in.)
667 mm(26.3 in.)
800 mm(31.5 in.)
65 mm(2.6 in.)
605 mm(23.8 in.)
65 mm(2.6 in.)
380 mm(15.0 in.)
770 mm(30.3 in.)
773 mm(30.4 in.)
CENI/L
CENIII/IV(34.84 in.)
865 mm (34.06 in.)
885 mm
47 mm(1.9 in.)
380 mm(15.0 in.)
1300 mm(51.2 in.)
1641 mm(64.6 in.)
868 mm(34.2 in.)
659 mm(25.9 in.)
843 mm(33.2 in.)
1171 mm(46.1 in.)
667 mm(26.3 in.)
800 mm(31.5 in.)
65 mm(2.6 in.)
605 mm(23.8 in.)
65 mm(2.6 in.)
280 mm(11.0 in.)
359 mm(14.1 in.)
134 mm(5.3 in.) 658 mm
(25.9 in.)
143 mm(5.6 in.)
168 mm(6.6 in.)
773 mm(30.4 in.)
380 mm(15.0 in.)
770 mm(30.3 in.)
CENI/L
CENIII/IV(34.84 in.)
865 mm (34.06 in.)
885 mm
CEN Grade I and CEN Grade L
CEN grade III CEN grade IV
Maximum weight878 kg
(1935 lb.)1036 kg(2285 lb.)
1076 kg(2372 lb.)
Floor loading1425 kg/m2 (292 lb./ft2)
1682 kg/m2 (345 lb./ft2)
1747 kg/m2 (358 lb./ft2)
CEN grade III CEN grade IV
Maximum weight1060 kg
(2336.9 lb.)1101 kg
(2427.3 lb.)
Floor loading1721 kg/m2 (352.4 lb./ft2)
1787 kg/m2 (366.0 lb./ft2)
CEN Grade I and CEN Grade L
CEN grade III CEN grade IV
Maximum weight888 kg
(1957.7 lb.)1046 kg
(2306 lb.)1086 kg
(2394.2 lb.)
Floor loading1442 kg/m2 (295.2 lb./ft2)
1698 kg/m2 (347.8 lb./ft2)
1763 kg/m2 (361.1 lb./ft2)
CEN grade III CEN grade IV
Maximum weight1070 kg
(2358.9 lb.)1111 kg
(2449.3 lb.)
Floor loading1737 kg/m2 (355.7 lb./ft2)
1804 kg/m2 (369.4 lb./ft2)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 2
COLLAR DIMENSIONS
Standard
Advert
Logo
Open Standard
Open Advert
Open Extended
CABLE ENTRY
38 mm(1.50 in.)
75 mm(2.95 in.)
626 mm(24.65 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1233 mm(48.54 in.)
352 mm(13.86 in.)
840 mm(33.07 in.)
276 mm(10.87 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1447 mm(56.97 in.)
352 mm(13.86 in.)
626 mm(24.65 in.)
62 mm(2.4 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
47 mm(1.85 in.)
352 mm(13.86 in.)
1233 mm(48.54 in.)
725 mm(28.54 in.)
38 mm(1.50 in.)
630 mm(24.80 in.)
60 mm(2.36 in.)
37 mm(1.46 in.)
129 mm(5.08 in.)
732 mm(28.82 in.)
1234 mm(48.58 in.)
298 mm(11.73 in.)
38 mm(1.5 in.)
855 mm(33.7 in.)
210 mm(8.3 in.)
291 mm(11.5 in.)
47 mm(1.9 in.)
75 mm(3.0 in.)
725 mm(28.5 in.)
1453 mm(57.20 in.)
352 mm(13.86 in.)
38 mm(1.50 in.)
60 mm(2.36 in.)
129 mm(5.08 in.)
859 mm(33.82 in.)
37 mm(1.46 in.)
732 mm(28.82 in.)
1234 mm(48.58 in.)
298 mm(11.73 in.)
535 mm(21.1 in.)
170 mm(6.7 in.)
770 mm(30.31 in.)
800 mm(31.50 in.)
150 mm(5.91 in.)
403 mm(15.87 in.)
247 mm(9.72 in.)
33 mm(1.30 in.)
65 mm(2.66 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard SleeveNCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 3
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of the bolt holes, using bolts with anchor washers as specified below. Bolts and anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading imposed by the anchor points for these bolts.
If an adjustable plinth is used, it must be bolted to the floor to the same specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a concrete floor is:
Bolts
Type ‐ either resin anchor or shield anchor bolts
Size ‐ M16 (5/8 in.)
Minimum Length ‐ 150 mm (5.9 in.)
Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
Type ‐ flat, steel (as per DIN7349 or equivalent)
Size ‐ M16 (5/8 in.)
Outer diameter ‐ no greater than 40 mm (1.58 in.)
Minimum thickness ‐ 6 mm (0.2 in.).
BOLT HOLES
The ATM should be bolted to the floor or plinth, through all the holes marked ‘A’, using four bolts with anchor washers.
The ‘B’ hole enables an alarm to be fitted (CEN III security enclosures only).
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
330 mm(13.00 in.)Maximum
504 mm(19.84 in.)
B
A
A
A
A
Hole A Bolt Holes (All CEN security enclosures) Hole B (Alarm Hole, CEN III security enclosures only)
Hole in Wall
500 mm(19.68 in.)
250 mm(9.84 in.)
285 mm(11.22 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
150 mm(5.91 in.)
500 mm(19.68 in.)
250 mm(9.84 in.)
150 mm(5.91 in.)
19 mm(0.75 in.)
45 mm(1.77 in.)
45 mm(1.77 in.)
20 mm(0.78 in.)
25 mm(0.98 in.)
28 mm(1.10 in.)
60 mm(2.36 in.)
45 mm(1.77 in.)
28 mm(1.10 in.)
B
A
A
A
A
Hole A Bolt Holes (All CEN security enclosures) Hole B (Alarm Hole, CEN III security enclosures only)
292 mm(11.50 in.)Maximum
500 mm(19.68 in.)
250 mm(9.84 in.)
285 mm(11.22 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
150 mm(5.91 in.)
500 mm(19.68 in.)
250 mm(9.84 in.)
150 mm(5.91 in.)
19 mm(0.75 in.)
435 mm(17.13 in.)
45 mm(1.77 in.)
45 mm(1.77 in.)
20 mm(0.78 in.)
25 mm(0.98 in.)
28 mm(1.10 in.)
60 mm(2.36 in.)
45 mm(1.77 in.)
28 mm(1.10 in.)
Hole in Wall
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 4
HOLE IN THE WALL
Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations. Where no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have the height specified in the illustrations below.
The open advert collar does not fit through this hole.
Standard, Advert or Logo Collar
Open Standard Collar
Hole at Lowered Height
It is the responsibility of the owning institution to make sure that the heights from the sidewalk level to the facia items comply with any local regulations.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have one of the heights specified in the table below.
Note that CEN certified security enclosures must have a CEN certified plinth.
NCR recommends the Open Standard or Open Advert Collar for lowered height installation.
Open Advert Collar
Open Standard or Open Extended Collar
View from Inside BuildingMaximum (13.0 in.)330 mm
534 mm(21.02 in.)
Plinth
Hole in Wall
19 mm(0.75 in.)
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
368 mm(14.49 in.)
ATM Base
View from Inside BuildingMaximum 292 mm (11.50 in.)
Plinth
19 mm(0.75 in.)
20 mm(0.79 in.)
Sidewalk
534 mm(21.02 in.)
625 mm(24.61 in.)
170 mm(6.70 in.)
36 mm(1.42 in.)
368 mm(14.49 in.)
Hole in Wall
ATM Base
1026 mm(40.39 in.)
Installation Height
CAEParallel Approach
ADACSA
Parallel Approach
A - Bottom of hole816 mm
(32.13 in.)786 mm
(30.94 in.)766 mm
(30.16 in.)
B - Plinth height168 mm(6.61 in.)
138 mm(5.43 in.)
118 mm(4.65 in.)
B
Hole in Wall
ATM Base
View from Inside BuildingMaximum (13.00 in.)330 mm
744 mm(29.29 in.)
Plinth
A
19 mm(0.75 in.)
625 mm(24.61 in.)
Sidewalk
Plinth
ATM Base
View from Inside BuildingMaximum (11.50 in.)292 mm
534 mm(21.02 in.)
Hole in Wall
19 mm(0.75 in.)
625 mm(24.61 in.)
170 mm(6.69 in.)
36 mm(1.42 in.)
20 mm(0.79 in.)
Sidewalk
A
B
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard SleeveNCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 5
FACIA ITEMS
Topmost Viewable Facia Item
Depending on the configuration of the ATM the statement exit slot or the cheque entry slot may be the highest viewable facia item.
The following table shows the projected angles (‘A’ in the illustration) from the front of the collar to the topmost viewable facia item for the different collar types. The illustration shows the Standard collar.
Heights and Depths Distance for Voice Guidance
Standard or Advert Collar
Open Standard or Open Extended Collar
Open Advert Collar
Statement Exit 27 degrees 34 degrees 40 degrees
Cheque Entry 44 degrees 60 degrees 66 degrees
5JKL
$
S
12
34
56
78
9
S
12
34
56
78
9
A
Facia ItemHeight
from baseof ATM
Depthfrom front
of shelf
Statement Exit1079 mm(42.48 in.)
245 mm(9.64 in.)
Passbook Entry/Exit1079 mm(42.48 in.)
245 mm(9.64 in.)
Receipt1079 mm(42.48 in.)
155 mm(6.10 in.)
Cheque Entry1060 mm(41.73 in.)
185 mm(7.28 in.)
Coin Exit1074 mm(42.28 in.)
206 mm(8.11 in.)
Touchscreen381 mm (15.0 in.)
Top1029 mm(40.51 in.)
258 mm(10.16 in.)
Touchscreen307 mm (12.1 in.)
Top1008 mm(39.68 in.)
252 mm(9.92 in.)
Display with FDKs381 mm (15.0 in.) Display
Top FDK961 mm
(37.83 in.)206 mm(8.11 in.)
Card Reader958 mm
(37.72 in.)125 mm(4.92 in.)
Display with FDKs307 mm (12.1 in.) Display
Top FDK954 mm
(37.56 in.)201 mm(7.91 in.)
Contactless Card Reader (on Facia)883 mm(34.76 in.
106 mm(4.17 in.)
Camera874 mm
(34.41 in.)121 mm(4.76 in.)
Private Audio824 mm
(32.44 in.)119 mm(4.68 in.)
Cash Exit/Entry749 mm
(29.49 in.)137 mm(5.39 in.)
Envelope Exit/Entry749 mm
(29.49 in.)137 mm(5.39 in.)
Scalable Deposit Module749 mm
(29.49 in.)137 mm(5.39 in.)
Fingerprint Reader733 mm
(28.86 in.)59 mm
(2.32 in.)
Contactless Card Reader (behind Facia)714 mm
(28.11 in.)80 mm
(3.14 in.)
PIN Pad Number 5 key714 mm
(28.11 in.)69 mm
(2.72 in.)
$
S
12
34
56
78
9
5JKL
Facia ItemDistance from
No. 5 Key
Receipt 1446 mm
(17.56 in.)
Card Reader 1355 mm
(13.98 in.)
Contactless Card Reader(on Facia)
2296 mm
(11.65 in.)
Private Audio 2264 mm
(10.39 in.)
Cash Exit/Entry 3184 mm(7.24 in.)
Envelope Exit/Entry 3184 mm(7.24 in.)
Contactless Card Reader (behind Facia) 3242 mm(9.53 in.)
Fingerprint Reader 9217 mm(8.54 in.)
Cash Exit/Entry 9144 mm(5.67 in.)
Envelope Exit/Entry 9144 mm(5.67 in.)
Scalable Deposit Module 9144 mm(5.67 in.)
Display with FDKs307 mm (12.1 in.) Display
Top Left FDK
10306 mm
(12.05 in.)
Display with FDKs381 mm (15.0 in.) Display
Top Left FDK
10333 mm
(13.11 in.)
Cheque Entry 11426 mm
(16.77 in.)
Coin Exit 11426 mm
(16.77 in.)
Statement Exit 12378 mm
(14.88 in.)
Passbook Entry/Exit 12378 mm
(14.88 in.)
12111098
7 6 543
21
S
S
12
34
56
78
9
$
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 6
SERVICING AREAS ‐ OPTIMUM ‐ SINGLE ATM
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
2481 mm(97.68 in.)
750 mm(29.53 in.)
330 mm(13.00 in.)Maximum
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2427 mm(95.55 in.)
292 mm(11.50 in.)Maximum
Maximum
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 7
SERVICING AREAS ‐ OPTIMUM ‐ SIDE BY SIDE
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2481 mm(97.68 in.)
330 mm(13.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
292 mm(11.50 in.)Maximum
2427 mm(95.55 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 8
SERVICING AREAS ‐ MINIMUM ‐ SINGLE ATM
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1
2
3
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
330 mm(13.00 in.)Maximum 750 mm
(29.53 in.)
2155 mm(84.84 in.)
2377 mm(93.58 in.)
1
2
3
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
292 mm(11.5 in.)Maximum 750 mm
(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
2101 mm(82.72 in.)
2323 mm(91.46 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐ 9
SERVICING AREAS ‐ MINIMUM ‐ SIDE BY SIDE
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
330 mm(13.00 in.)Maximum
2155 mm(84.84 in.)
2377 mm(93.58 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
292 mm(11.5 in.)Maximum
2101 mm(82.72 in.)
2323 mm(91.46 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ CEN, Standard Sleeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
10 ‐
CLEARANCES ‐ CORRIDOR
The dimensions shown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
CLEARANCE ‐ PRESSURISATION FAN
The illustration below shows the minimum height clearance required for the installation, removal, and replacement of the pressurisation fan module.
CLEARANCES ‐ EXTERIOR WALL
Standard, Open Standard or Logo Collar
Advert Collar
Open Advert Collar
Open Extended Collar
INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA
If a third‐party camera is to be installed, it must fit within the space constraint shown below.
Packaged ATM(pallet, carton
and lid)
Packaged ATM(pallet and
carton)
Unpackaged ATM
A Doorway or straight corridor989 mm
(38.94 in.)969 mm
(38.15 in.)785 mm
(30.91 in.)
B Corridor with corner1224 mm(48.19 in.)
1199 mm(47.20 in.)
1022 mm(40.24 in.)
C Rotation about centre1748 mm(68.82 in.)
1712 mm(67.40 in.)
1524 mm(60.00 in.)
C
B
BA
350 mm(13.78 in.)493 mm
(19.41 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
100 mm(3.94 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
56º
60 mm(2.36 in.)
30 mm(1.81 in.)
60 mm(2.36 in.)
30 mm(1.81 in.)
180 mm(7.08 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
11 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationVariant Details ‐ UL, Short SLeeve
PACKAGE DIMENSIONS
ATM DIMENSIONS
COLLAR DIMENSIONS
Standard
Advert
Logo
Open Standard
Open Advert
Open Extended
957 mm(37.68 in.)
977 mm(38.46 in.)
1405 mm(55.24 in.)
1435 mm(56.50 in.)
1836 mm(72.28 in.)
1693 mm(66.65 in.)
65 mm(2.56 in.)
605 mm(23.82 in.)
65 mm(2.56 in.)
47 mm(1.85 in.)
267 mm(10.51 in.)
267 mm(10.51 in.)
1187 mm(46.73 in.)
1489 mm(58.62 in.)
839 mm(33.03 in.)
868 mm(34.17 in.)
650 mm(25.59 in.)
834 mm(32.83 in.)
1162 mm(45.75 in.)
655 mm(25.79 in.)
800 mm(31.50 in.)
770 mm(30.31 in.)
773 mm(30.43 in.)
38 mm(1.49 in.)
75 mm(2.95 in.)
626 mm(24.6 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1224 mm(48.19 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
75 mm(2.94 in.)
840 mm(33.07 in.)
276 mm(10.87 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1438 mm(56.61 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
626 mm(24.65 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1224 mm(48.19 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
630 mm(24.80 in.)
60 mm(2.36 in.)
37 mm(1.46 in.)
129 mm(5.08 in.)
732 mm(28.82 in.)
1225 mm(48.23 in.)
185 mm(7.28 in.)
38 mm(1.49 in.)
855 mm(33.66 in.)
210 mm(8.27 in.)
291 mm(11.57 in.)
47 mm(1.85 in.)
75 mm(2.95 in.)
725 mm(28.54 in.)
1453 mm(57.20 in.)
239 mm(9.41 in.)
38 mm(1.50 in.)
60 mm(2.36 in.)
129 mm(5.08 in.)
859 mm(33.82 in.)
37 mm(1.46 in.)
732 mm(28.82 in.)
1225 mm(48.23 in.)
185 mm(7.28 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 2
WEIGHT AND FLOOR LOADING
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of the bolt holes, using bolts with anchor washers as specified below. Bolts and anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading imposed by the anchor points for these bolts.
If an adjustable plinth is used, it must be bolted to the floor to the same specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a concrete floor is:
Bolts
Type ‐ either resin anchor or shield anchor bolts
Size ‐ M16 (5/8 in.)
Minimum Length ‐ 150 mm (5.9 in.)
Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
Type ‐ flat, steel (as per DIN7349 or equivalent)
Size ‐ M16 (5/8 in.)
Outer diameter ‐ no greater than 40 mm (1.58 in.)
Minimum thickness ‐ 6 mm (0.2 in.).
BOLT HOLES
The ATM should be bolted to the floor or plinth, through all the holes marked ‘A’, using four bolts with anchor washers.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
CABLE ENTRY
UL 291 Level 1
Maximum weight831 kg
(1833 lb.)
Floor loading1349 kg/m2 (277 lb./ft2)
203 mm (8.00 in.)Maximum
Hole in Wall
500 mm(19.68 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
135 mm(5.31 in.)
500 mm(19.68 in.)
30 mm(1.18 in.)
165 mm(6.50 in.)
285 mm(11.22 in.)
19 mm(0.75 in.)
369 mm(14.53 in.)
Ø 25 mm(0.98 in.)
Slots in4 Places
A
A
A
A
Security Enclosure
178 mm (7.00 in.)Maximum
315 mm(12.40 in.)
500 mm(19.68 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
135 mm(5.31 in.)
500 mm(19.68 in.)
30 mm(1.18 in.)
165 mm(6.50 in.)
285 mm(11.22 in.)
19 mm(0.75 in.)
Ø 25 mm(0.98 in.)
Slots in4 Places
A
A
A
A
Security Enclosure
Hole in Wall
770 mm(30.31 in.)
800 mm(31.50 in.)
43 mm(1.69 in.)
36 mm(1.42 in.)
408 mm(16.06 in.)
135 mm(5.3 in.)
257 mm(10.12 in.)
564 mm(22.20 in.)
170 mm(6.69 in.)
Cable Entry Hole
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 3
HOLE IN THE WALL
Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations. Where no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have the height specified in the illustrations below.
The open advert collar does not fit through this hole.
Standard, Advert or Logo Collar
Open Standard Collar
Hole at Lowered Height
It is the responsibility of the owning institution to make sure that the heights from the sidewalk level to the facia items comply with any local regulations.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have one of the heights specified in the table below.
NCR recommends the Open Standard or Open Advert Collar for lowered height installation.
Open Advert Collar
Open Standard or Open Extended Collar
View from Inside BuildingMaximum (8.00 in.)203 mm
534 mm(21.02 in.)
Plinth
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
377mm(14.84 in.)
View from Inside BuildingMaximum (7.00 in.)178 mm
534 mm(21.02 in.)
Plinth
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
377mm(14.84 in.)
Installation Height
CAEParallel Approach
ADACSA
Parallel Approach
A - Bottom of hole816 mm
(32.13 in.)786 mm
(30.94 in.)766 mm
(30.16 in.)
B - Plinth height177 mm(6.97 in.)
147 mm(5.79 in.)
127 mm(5.00 in.)
Maximum (8.00 in.)203 mm
744 mm(29.29 in.)
A
B
19 mm(0.7 5in.)
625 mm(24.61 in.)
Hole in Wall
ATM Base
View from Inside Building
PlinthSidewalk
View from Inside BuildingMaximum (7.01 in.)178 mm
534 mm(21.02 in.)
ATM Base
19 mm(0.75 in.)
Hole in Wall
625 mm(24.61 in.)
Sidewalk
A
B
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 4
FACIA ITEMS
Topmost Viewable Facia Item
Depending on the configuration of the ATM the statement exit slot or the cheque entry slot may be the highest viewable facia item.
The following table shows the projected angles (‘A’ in the illustration) from the front of the collar to the topmost viewable facia item for the different collar types. The illustration shows the Standard collar.
Heights and Depths Distance for Voice Guidance
Standard or Advert Collar
Open Standard or Open Extended Collar
Open Advert Collar
Statement Exit 27 degrees 34 degrees 40 degrees
Cheque Entry 44 degrees 60 degrees 66 degrees
56º
60 mm(2.36 in.)
30 mm(1.81 in.)
60 mm(2.36 in.)
30 mm(1.81 in.)
180 mm(7.08 in.)
A
Facia ItemHeight
from baseof ATM
Depthfrom front
of shelf
Statement Exit1070 mm(42.13 in.)
245 mm(9.64 in.)
Passbook Entry/Exit1070 mm(42.13 in.)
245 mm(9.64 in.)
Receipt1070 mm(42.13 in.)
155 mm(6.10 in.)
Cheque Entry1051 mm(41.38 in.)
185 mm(7.28 in.)
Coin Exit1065 mm(41.93 in.)
206 mm(8.11 in.)
Touchscreen381 mm (15.0 in.)
Top1020 mm(40.16 in.)
258 mm(10.16 in.)
Touchscreen307 mm (12.1 in.)
Top999 mm
(39.33 in.)252 mm(9.92 in.)
Display with FDKs381 mm (15.0 in.) Display
Top FDK952 mm
(37.48 in.)206 mm(8.11 in.)
Card Reader949 mm
(37.36 in.)125 mm(4.92 in.)
Display with FDKs307 mm (12.1 in.) Display
Top FDK945 mm
(37.20 in.)201 mm(7.91 in.)
Contactless Card Reader (on Facia)874 mm(34.41 in.
106 mm(4.17 in.)
Camera865 mm
(34.06 in.)121 mm(4.76 in.)
Private Audio815 mm
(32.09 in.)119 mm(4.68 in.)
Cash Exit/Entry740 mm
(29.13 in.)137 mm(5.39 in.)
Envelope Exit/Entry740 mm
(29.13 in.)137 mm(5.39 in.)
Scalable Deposit Module740 mm
(29.13 in.)137 mm(5.39 in.)
Fingerprint Reader724 mm
(28.50 in.)59 mm
(2.32 in.)
Contactless Card Reader (behind Facia)705 mm
(27.76 in.)80 mm
(3.14 in.)
PIN Pad Number 5 key659 mm
(25.94 in.)69 mm
(2.72 in.)
$
S
12
34
56
78
9
5JKL
Facia ItemDistance from
No. 5 Key
Receipt 1446 mm
(17.56 in.)
Card Reader 1355 mm
(13.98 in.)
Contactless Card Reader(on Facia)
2296 mm
(11.65 in.)
Private Audio 2264 mm
(10.39 in.)
Cash Exit/Entry 3184 mm(7.24 in.)
Envelope Exit/Entry 3184 mm(7.24 in.)
Contactless Card Reader (behind Facia) 3242 mm(9.53 in.)
Fingerprint Reader 9217 mm(8.54 in.)
Cash Exit/Entry 9144 mm(5.67 in.)
Envelope Exit/Entry 9144 mm(5.67 in.)
Scalable Deposit Module 9144 mm(5.67 in.)
Display with FDKs307 mm (12.1 in.) Display
Top Left FDK
10306 mm
(12.05 in.)
Display with FDKs381 mm (15.0 in.) Display
Top Left FDK
10333 mm
(13.11 in.)
Cheque Entry 11426 mm
(16.77 in.)
Coin Exit 11426 mm
(16.77 in.)
Statement Exit 12378 mm
(14.88 in.)
Passbook Entry/Exit 12378 mm
(14.88 in.)
12111098
7 6 543
21
S
S
12
34
56
78
9
$
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 5
SERVICING AREAS ‐ OPTIMUM ‐ SINGLE ATM
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2314 mm(91.10 in.)
178 mm(7.00 in.)Maximum
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 6
SERVICING AREAS ‐ OPTIMUM ‐ SIDE BY SIDE
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
203 mm(8.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
2368 mm(93.23 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2314 mm(91.10 in.)
178 mm(7.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 7
SERVICING AREAS ‐ MINIMUM ‐ SINGLE ATM
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
2042 mm(80.39 in.)
326 mm(12.83 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
750 mm(29.53 in.)
2314 mm(91.10 in.)
178 mm(7.00 in.)Maximum
1988 mm(78.27 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 8
SERVICING AREAS ‐ MINIMUM ‐ SIDE BY SIDE
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2368 mm(93.23 in.)
203 mm(8.00 in.)Maximum
2042 mm(80.39 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
178 mm(7.00 in.)Maximum
2314 mm(91.10 in.) 1988 mm
(78.27 in.)
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Short SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
11 ‐ 9
CLEARANCES ‐ CORRIDOR
The dimensions shown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
CLEARANCES ‐ EXTERIOR WALL
Standard, Open Standard or Logo Collar
Advert Collar
Open Advert Collar
Open Extended Collar
INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA
If a third‐party camera is to be installed, it must fit within the space constraint shown below.
Packaged ATM(pallet, carton
and lid)
Packaged ATM(pallet and
carton)
Unpackaged ATM
A Doorway or straight corridor989 mm
(38.94 in.)969 mm
(38.15 in.)785 mm
(30.91 in.)
B Corridor with corner1224 mm(48.19 in.)
1199 mm(47.20 in.)
986 mm(38.82 in.)
C Rotation about centre1748 mm(68.82 in.)
1712 mm(67.40 in.)
1428 mm(56.22 in.)
C
B
BA
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
100 mm(3.94 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
56º
60 mm(2.36 in.)
30 mm(1.81 in.)
60 mm(2.36 in.)
30 mm(1.81 in.)
150 mm(5.90 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
12 ‐ 1
NCR SelfServ™ 34 Walk‐Up ATM Site PreparationVariant Details ‐ UL, Standard SLeeve
PACKAGE DIMENSIONS
ATM DIMENSIONS
COLLAR DIMENSIONS
Standard
Advert
Logo
Open Standard
Open Advert
Open Extended
957 mm(37.68 in.)
977 mm(38.46 in.)
1405 mm(55.24 in.)
1435 mm(56.50 in.)
1836 mm(72.28 in.)
1693 mm(66.65 in.)
773 mm(30.4 in.)
800 mm(31.5 in.)
65 mm(2.6 in.)
47 mm(1.9 in.)
380 mm(15.0 in.)
380 mm(15.0 in.)
1300 mm(51.2 in.)
1489 mm(58.6 in.)
839 mm(33.0 in.)
868 mm(34.2 in.)
650 mm(25.6 in.)
834 mm(32.8 in.)
1162 mm(45.7 in.)
658 mm(25.9 in.)
605 mm(23.8 in.)
65 mm(2.6 in.)
770 mm(30.3 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
626 mm(24.65 in.)
62 mm(2.44 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1224 mm(48.19 in.)
352 mm(13.86 in.)
840 mm(33.07 in.)
276 mm(10.87 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
47 mm(1.85 in.)
725 mm(28.54 in.)
1438 mm(56.61 in.)
352 mm(13.86 in.)
626 mm(24.65 in.)
62 mm(2.4 in.)
38 mm(1.50 in.)
75 mm(2.95 in.)
47 mm(1.85 in.)
352 mm(13.86 in.)
1224 mm(48.19 in.)
725 mm(28.54 in.)
38 mm(1.50 in.)
630 mm(24.80 in.)
60 mm(2.36 in.)
37 mm(1.46 in.)
129 mm(5.08 in.)
732 mm(28.82 in.)
1225 mm(48.23 in.)
298 mm(11.73 in.)
38 mm(1.5 in.)
855 mm(33.7 in.)
210 mm(8.3 in.)
291 mm(11.5 in.)
47 mm(1.9 in.)
75 mm(3.0 in.)
725 mm(28.5 in.)
1453 mm(57.20 in.)
352 mm(13.86 in.)
298 mm(11.73 in.)
38 mm(1.50 in.)
60 mm(2.36 in.)
129 mm(5.08 in.)
859 mm(33.82 in.)
37 mm(1.46 in.)
732 mm(28.82 in.)
1225 mm(48.23 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 2
WEIGHT AND FLOOR LOADING
SECURITY BOLTS
Bolts and anchors must be supplied by the owning organisation.
To meet security standards the ATM must be bolted to the floor, through all of the bolt holes, using bolts with anchor washers as specified below. Bolts and anchor washers are to be supplied by the owning organisation.
Make sure that the floor or plinth is capable of withstanding the loading imposed by the anchor points for these bolts.
If an adjustable plinth is used, it must be bolted to the floor to the same specification as the ATM.
The minimum specification for bolts and washers to secure the ATM to a concrete floor is:
Bolts
Type ‐ either resin anchor or shield anchor bolts
Size ‐ M16 (5/8 in.)
Minimum Length ‐ 150 mm (5.9 in.)
Strength ‐ high tensile (minimum ISO property class 8,8).
Washers
Type ‐ flat, steel (as per DIN7349 or equivalent)
Size ‐ M16 (5/8 in.)
Outer diameter ‐ no greater than 40 mm (1.58 in.)
Minimum thickness ‐ 6 mm (0.2 in.).
BOLT HOLES
The ATM should be bolted to the floor or plinth, through all the holes marked ‘A’, using four bolts with anchor washers.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
CABLE ENTRY
UL 291 Level 1
Maximum weight831 kg
(1833 lb.)
Floor loading1349 kg/m2 (277 lb./ft2)
489 mm(19.25 in.)330 mm
(13.00 in.)Maximum
500 mm(19.68 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
135 mm(5.31 in.)
500 mm(19.68 in.)
30 mm(1.18 in.)
165 mm(6.50 in.)
285 mm(11.22 in.)
19 mm(0.75 in.)
Ø 25 mm(0.98 in.)
Slots in4 Places
A
A
A
A
Security Enclosure
Hole in Wall
435 mm(17.13 in.)292 mm
(11.50 in.)Maximum
500 mm(19.68 in.)
770 mm(30.31 in.)
170 mm(6.69 in.)
800 mm(31.50 in.)
135 mm(5.31 in.)
500 mm(19.68 in.)
30 mm(1.18 in.)
165 mm(6.50 in.)
285 mm(11.22 in.)
19 mm(0.75 in.)
Ø 25 mm(0.98 in.)
Slots in4 Places
A
A
A
A
Security Enclosure
Hole in Wall
770 mm(30.31 in.)
800 mm(31.50 in.)
43 mm(1.69 in.)
36 mm(1.42 in.)
408 mm(16.06 in.)
135 mm(5.3 in.)
257 mm(10.12 in.)
564 mm(22.20 in.)
170 mm(6.69 in.)
Cable Entry Hole
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 3
HOLE IN THE WALL
Hole at Optimum Height
It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations. Where no such regulations exist, the ATM can be installed at the NCR optimum height.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have the height specified in the illustrations below.
The open advert collar does not fit through this hole.
Standard, Advert or Logo Collar
Open Standard Collar
Hole at Lowered Height
It is the responsibility of the owning institution to make sure that the heights from the sidewalk level to the facia items comply with any local regulations.
For correct installation height you must consider the difference in height between the sidewalk and the interior floor. If there is no difference then the plinth must have one of the heights specified in the table below.
NCR recommends the Open Standard or Open Advert Collar for lowered height installation.
Open Advert Collar
Open Standard or Open Extended Collar
View from Inside BuildingMaximum (13.0 in.)330 mm
534 mm(21.02 in.)
Plinth
Hole in Wall
19 mm(0.75 in.)
625 mm(24.61 in.)
Sidewalk
1026 mm(40.39 in.)
377 mm(14.84 in.)
ATM Base
View from Inside BuildingMaximum 292 mm (11.50 in.)
Plinth
19 mm(0.75 in.)
20 mm(0.79 in.)
Sidewalk
534 mm(21.02 in.)
625 mm(24.61 in.)
170 mm(6.70 in.)
36 mm(1.42 in.)
377 mm(14.84 in.)
Hole in Wall
ATM Base
1026 mm(40.39 in.)
Installation Height
CAEParallel Approach
ADACSA
Parallel Approach
A - Bottom of hole816 mm
(32.13 in.)786 mm
(30.94 in.)766 mm
(30.16 in.)
B - Plinth height177 mm(6.97 in.)
147 mm(5.79 in.)
127 mm(5.00 in.)
B
Hole in Wall
ATM Base
View from Inside BuildingMaximum (13.00 in.)330 mm
744 mm(29.29 in.)
Plinth
A
19 mm(0.75 in.)
625 mm(24.61 in.)
Sidewalk
Plinth
ATM Base
View from Inside BuildingMaximum (11.50 in.)292 mm
534 mm(21.02 in.)
Hole in Wall
19 mm(0.75 in.)
625 mm(24.61 in.)
170 mm(6.69 in.)
36 mm(1.42 in.)
20 mm(0.79 in.)
Sidewalk
A
B
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 4
FACIA ITEMS
Topmost Viewable Facia Item
Depending on the configuration of the ATM the statement exit slot or the cheque entry slot may be the highest viewable facia item.
The following table shows the projected angles (‘A’ in the illustration) from the front of the collar to the topmost viewable facia item for the different collar types. The illustration shows the Standard collar.
Heights and Depths Distance for Voice Guidance
Standard or Advert Collar
Open Standard or Open Extended Collar
Open Advert Collar
Statement Exit 27 degrees 34 degrees 40 degrees
Cheque Entry 44 degrees 60 degrees 66 degrees
5JKL
$
S
12
34
56
78
9
S
12
34
56
78
9
A
Facia ItemHeight
from baseof ATM
Depthfrom front
of shelf
Statement Exit1070 mm(42.13 in.)
245 mm(9.64 in.)
Passbook Entry/Exit1070 mm(42.13 in.)
245 mm(9.64 in.)
Receipt1070 mm(42.13 in.)
155 mm(6.10 in.)
Cheque Entry1051 mm(41.38 in.)
185 mm(7.28 in.)
Coin Exit1065 mm(41.93 in.)
206 mm(8.11 in.)
Touchscreen381 mm (15.0 in.)
Top1020 mm(40.16 in.)
258 mm(10.16 in.)
Touchscreen307 mm (12.1 in.)
Top999 mm
(39.33 in.)252 mm(9.92 in.)
Display with FDKs381 mm (15.0 in.) Display
Top FDK952 mm
(37.48 in.)206 mm(8.11 in.)
Card Reader949 mm
(37.36 in.)125 mm(4.92 in.)
Display with FDKs307 mm (12.1 in.) Display
Top FDK945 mm
(37.20 in.)201 mm(7.91 in.)
Contactless Card Reader (on Facia)874 mm(34.41 in.
106 mm(4.17 in.)
Camera865 mm
(34.06 in.)121 mm(4.76 in.)
Private Audio815 mm
(32.09 in.)119 mm(4.68 in.)
Cash Exit/Entry740 mm
(29.13 in.)137 mm(5.39 in.)
Envelope Exit/Entry740 mm
(29.13 in.)137 mm(5.39 in.)
Scalable Deposit Module740 mm
(29.13 in.)137 mm(5.39 in.)
Fingerprint Reader724 mm
(28.50 in.)59 mm
(2.32 in.)
Contactless Card Reader (behind Facia)705 mm
(27.76 in.)80 mm
(3.14 in.)
PIN Pad Number 5 key659 mm
(25.94 in.)69 mm
(2.72 in.)
$
S
12
34
56
78
9
5JKL
Facia ItemDistance from
No. 5 Key
Receipt 1446 mm
(17.56 in.)
Card Reader 1355 mm
(13.98 in.)
Contactless Card Reader(on Facia)
2296 mm
(11.65 in.)
Private Audio 2264 mm
(10.39 in.)
Cash Exit/Entry 3184 mm(7.24 in.)
Envelope Exit/Entry 3184 mm(7.24 in.)
Contactless Card Reader (behind Facia) 3242 mm(9.53 in.)
Fingerprint Reader 9217 mm(8.54 in.)
Cash Exit/Entry 9144 mm(5.67 in.)
Envelope Exit/Entry 9144 mm(5.67 in.)
Scalable Deposit Module 9144 mm(5.67 in.)
Display with FDKs307 mm (12.1 in.) Display
Top Left FDK
10306 mm
(12.05 in.)
Display with FDKs381 mm (15.0 in.) Display
Top Left FDK
10333 mm
(13.11 in.)
Cheque Entry 11426 mm
(16.77 in.)
Coin Exit 11426 mm
(16.77 in.)
Statement Exit 12378 mm
(14.88 in.)
Passbook Entry/Exit 12378 mm
(14.88 in.)
12111098
7 6 543
21
S
S
12
34
56
78
9
$
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 5
SERVICING AREAS ‐ OPTIMUM ‐ SINGLE ATM
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2481 mm(97.68 in.)
330 mm(13.00 in.)Maximum
1780 mm(70.08 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2427 mm(95.55 in.)
292 mm(11.50 in.)Maximum
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 6
SERVICING AREAS ‐ OPTIMUM ‐ SIDE BY SIDE
The optimum servicing area provides the best access to the ATM for all servicing and operation tasks.
Wherever possible the ATM should be installed within the optimum servicing area.
If the optimum area is not available then refer to Servicing Areas ‐ Minimum. However note that installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time over a ATM installed using the optimum area.
Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
2481 mm(97.68 in.)
330 mm(13.00 in.)Maximum
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
770 mm(30.31 in.)
525 mm(20.67 in.)
460 mm(18.11 in.)
25 mm(0.98 in.)
460 mm(18.11 in.)
326 mm(12.83 in.)
1000 mm(39.37 in.)
750 mm(29.53 in.)
460 mm(18.11 in.)
90 mm(3.54 in.)
3010 mm(118.5 in.)
292 mm(11.50 in.)Maximum
2427 mm(95.55 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 7
SERVICING AREAS ‐ MINIMUM ‐ SINGLE ATM
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar Open Standard or Open Extended Collar
1
2
3
1
2
3
330 mm(13.00 in.)Maximum 750 mm
(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2155 mm(84.84 in.)
326 mm(12.83 in.)
2377 mm(93.58 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
292 mm(11.5 in.)Maximum 750 mm
(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
1209 mm(47.60 in.)
1431 mm(56.34 in.)
1571 mm(61.85 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
2101 mm(82.72 in.)
326 mm(12.83 in.)
2323 mm(91.46 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 8
SERVICING AREAS ‐ MINIMUM ‐ SIDE BY SIDE
This is the minimum area required for operating and servicing the ATM.
Wherever possible the ATM should be installed within the optimum servicing area. Installing the ATM in the minimum servicing area may increase the servicing and/or upgrading time.
If the minimum area is not available then consult your local service representative. Every site is different and you may still be able to install the ATM but with further increases to servicing and/or upgrading time.
If you install in the minimum area then note that doors can open, and devices rack out, beyond the area shown. Always leave as much space as possible around the ATM to facilitate safe operation and servicing.
Standard, Advert, Logo or Open Advert Collar
Open Standard or Open Extended Collar
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
330 mm(13.00 in.)Maximum
2155 mm(84.84 in.)
2377 mm(93.58 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
1
2
3
1
2
3
750 mm(29.53 in.)
320 mm(12.60 in.)
98 mm(3.86 in.)
222 mm(8.74 in.)
460 mm(18.11 in.)
1000 mm(39.37 in.)
770 mm(30.31 in.)
550 mm(21.65 in.)
341 mm(13.43 in.)
211 mm(8.31 in.)
326 mm(12.83 in.)
70 mm(2.76 in.)
770 mm(30.31 in.)
2271 mm(89.41 in.)
2411 mm(94.92 in.)
2049 mm(80.67 in.)
292 mm(11.5 in.)Maximum
2101 mm(82.72 in.)
2323 mm(91.46 in.)
Cash Acceptor/Recycler or Scalable Deposit Module (LH side)
Scalable Deposit Module or BNA (RH side)
BNA or Cash Acceptor/Recycler
Minimum clearance
Additional clearances required for:
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000
Variant Details ‐ UL, Standard SLeeve NCR SelfServ™ 34 Walk‐Up ATM Site Preparation
12 ‐ 9
CLEARANCES ‐ CORRIDOR
The dimensions shown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions.
CLEARANCES ‐ EXTERIOR WALL
Standard, Open Standard or Logo Collar
Advert Collar
Open Advert Collar
Open Extended Collar
INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA
If a third‐party camera is to be installed, it must fit within the space constraint shown below.
Packaged ATM(pallet, carton
and lid)
Packaged ATM(pallet and
carton)
Unpackaged ATM
A Doorway or straight corridor989 mm
(38.94 in.)969 mm
(38.15 in.)785 mm
(30.91 in.)
B Corridor with corner1224 mm(48.19 in.)
1199 mm(47.20 in.)
1022 mm(40.24 in.)
C Rotation about centre1748 mm(68.82 in.)
1712 mm(67.40 in.)
1524 mm(60.00 in.)
C
B
BA
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
100 mm(3.94 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
10 mm(0.39 in.)
45 mm(1.77 in.)
30 mm(1.18 in.)
30 mm(1.18 in.)
56º
60 mm(2.36 in.)
30 mm(1.81 in.)
60 mm(2.36 in.)
30 mm(1.81 in.)
180 mm(7.08 in.)
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2007, 2008, 2009, 2010, 2012, 2013 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐6586‐P000