MSR 145 - Condair · • Read the operating instructions carefully before using the MSR 145 or the...

Post on 19-May-2020

12 views 0 download

Transcript of MSR 145 - Condair · • Read the operating instructions carefully before using the MSR 145 or the...

User manual

MSR 145

PC software

Other PC software

Online

Viewer

Setup

operating instructions

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

…In

stru

ctio

ns

Reader

Inst

ruct

ions

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Contents

Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important notes regarding this user manual . . . . . . . . . . . . . . . . . . . . . 4Safety instructions and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 MSR 145 Modular Signal Recorder Operating Instructions . . . . . . . . . . 6Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Turningtheuniton/savingmeasurementparameters . . . . . . . . . . . . . . . . 8Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Userchecks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chargingthebattery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Operating,transportandstorageconditions . . . . . . . . . . . . . . . . . . . . . . . . 13Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Packinglist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Declarationofconformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14MSR PC software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 OtherMSRPCsoftware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Inst

ruct

ions

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Important notes regarding this user manual Inthismanualnotesofparticularimportancearepresentedasfollows:

ConventionsTerm / Symbol Description ExampleMSR145 Inthismanualtheterm"MSR145"

isusedtomeanboth"MSR145S"and"MSR145W"

Commands,programs,menuitems,functions,fieldnames

Commands,programs,menuitems,functions,fieldnamesareshowninbold .

Record

->X SeepageX ->5•Referencetofurtherinformation•Furtherinformation

CAUTIONIndicates that equipment may suffer dam-ageor thatdata lossmayoccurshould theinstructionsnotbefollowedcorrectly .

WARNINGIndicates that equipment may suffer dam-ageorthatthereisariskofinjurytotheop-eratororusershouldtheinstructionsnotbefollowedcorrectly .

Inst

ruct

ions

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Safety instructions and warnings

WARNING

•ReadtheoperatinginstructionscarefullybeforeusingtheMSR145ortheMSRsoftware .Thiswillprotectyoupersonallyandavoiddamage to theunit .

•TheMSR145isaunitforrecordinganddisplayingmeasurementparam-etersandmaynotbeusedforsafety-relatedapplications .

•BeforeusingtheMSR145checktheunititselfandallcablesforvisiblesignsofdamageandneveroperateadamagedMSR145 .AdamagedMSR145canendangeroperatorsafety!ShouldtheMSR145notfunctionperfectlyorappeartobedamaged,sendittoMSRElectronicsGmbHforrepair .

•EnsurethatnofluidsentertheMSR145'scasing .Fluidscausecorrosiondamageandshort-circuitsinsidetheMSR145 .

•TheMSR145mustneverbeopenedormodified .Themanufacturercannotbeheldliablefordamageresultingfromuseotherthanthatforwhichtheunitisintended,orfromimproperoperationoftheunit .

•NeveruseanMSR145withaleakingbattery .Shouldabatteryleakbede-tectedensurethattheelectrolytedoesnotcomeintocontactwiththeskin,theeyesorthemouth .Shouldthisoccur,thoroughlyrinsetheaffectedareawithwaterforatleast15minutes .Consultadoctor .Donotbreatheinanyvapoursemitted .ImmediatelycleantheelectrolytefromtheMSR145usingasoftclothanddisposeoftheclothsubsequently .

CAUTION

•EnsuretheproperdisposalofanobsoleteMSR145andUSBconnectioncable->14 .

Inst

ruct

ions

Operating Instructions

MSR 145W

MSR 145S

Inst

ruct

ions

OverviewTheMSR145isaminiaturiseduniversaldataloggerformeasuringandrecordingdifferentphysicalmeasurementparameters .Itcontainsatemperaturesensor,ahumiditysensorwithintegratedtemperature,apressuresensoranda3-axisaccelerometer(X,YandZaxes) .Themeasurementparameterscanbetrans-ferredtoaPCeitheroncedataloggingiscompletedorduringthedataloggingprocess .

TheMSRPCprogramenablesuserstocustomisethewayinwhichtheMSR145measuresandrecordsdataaccordingtotheirrequirements .Theintegratedclock(RTC)allowsdatafromasmanyMSR145unitsasrequiredtobesynchronisedandmergedintoasingledatarecord .

Controls

USBconnectioncable CDwithMSRsoftware

MSR145S

MSR145W

Indicator LED’sBlue: Recordindicator->25Red: Alarmindicator->24Yellow:Batterycharge

indicator->10

Apertureforpressuresensor

Push-button

Apertureforhumiditysensor

USBPC-Interface

MSR145WMSR145S

Apertureforhumiditysensor

Inst

ruct

ions

Turning the unit on / saving measurement parametersTheMSR145commencesdatarecordingatthestarttimedefinedinSetup* .

*SetupisanMSRPCprogram(seeSetupchapter) .

Inst

ruct

ions

MaintenanceUser checks•ChecktheMSR145beforeeachuse .•BeforeusingtheMSR145checkforvisiblesignsofdamage .•CheckthefunctionsoftheMSR145 .•NeveruseanMSR145thatisdamagedornotfunctioningperfectly .Neveruse

damagedaccessories .•Ensurethatthebatteryissufficientlychargedfortherequiredperiodofuse .ShouldtheMSR145notfunctionperfectlyorshoulddamagebecomeapparentsendtheunittoMSRElectronicsGmbHforrepair .RepairsmayonlybecarriedoutbyMSRElectronicsGmbHoranauthoriseddealer .Defectiveordamagedcomponents may only be replaced with manufacturer’s original parts.

Cleaning

•CleantheMSR145whennecessary .•AlwaysdisconnecttheMSR145fromthePCbeforecleaning .•Useacleaningagentsuitableforplasticoraclothdampenedwithwaterand

soap .

Charging the batteryBeforefirstuse: Thebatteryisnotfullychargedondeliveryandshould

be charged for approx . 3 hours before using theMSR145forthefirsttime .

ChargetheMSR145: •Beforeeachuse •AtleasteverysixmonthsMethod:•ConnecttheMSR145andthePCusingtheUSBconnectioncable . Notes:

•EnsurethatthePCremainsswitchedon .•TheyellowLEDilluminatesduringcharging(continuously) .•Chargingiscompletedafteramaximumof3hours .• Recorded data is non-volatile and remains in the unit’s memory even when

thebatteryisexhausted .•NeverstoretheMSR145withadischargedbattery . See->13(storageconditions) .

CAUTION•MSR145S: Ensure that no fluids enter the

MSR145'scasing .Fluidswillcausecorrosiondamageandshortcircuits .

•Neverusecorrosiveorabrasivecleaningagentsorpolishes .•Cleaningagentscontainingadditivessuchasalcoholwillcausethecase

tobecomemattand/orbrittle .

Inst

ruct

ions

10

Meaning of the yellow lamp when a USB device is connectedYellow LED MeaningLightscontinuously Charginginprogress

Off FullychargedornoconnectiontoPCorPCturnedoff

Flashes Fullycharged

Thebatteryisrechargedforashorttime,e .g .duringanonlinemeasurementordatarecording

Inst

ruct

ions

11

Re

ad

er

Se

tup

Vie

we

rO

nli

ne

PC

…M

od

ule

sIn

stru

ctio

nsSpecifications

Measured parameters: •Temperature •RelativehumiditywithintegratedTemperature •Pressure(e .g .altimeter,waterlevel,barometer) •3-axisacceleration(e .g .determiningposition) •2analoginputs(voltagerange0to2 .4V,12bit)

Working range: Temperature: -10°Cto+65°C -55°Cto+125°C(optionalwithexternalsensor)Humidity: 0-100%relativeHumidity,-20°Cto+65°CPressure: 0-2500mbarabsolute Optional:0-14000mbarabsoluteAcceleration: ±10G/±2Gselectable

Accuracy: Temperature: ±0,1°C(5°Cto45°C) ±0,2°C(-10°Cto+65°C) Optionswithexternalsensor: ±0,1°C(5°Cto45°C) ±0,5°C(0°Cto+70°C) ±2°C(-55°Cto+125°C)Humidity: ±2%relativehumidity (10-90%relativehumidity,0°Cto40°C) ±0,5°C(0°Cto40°C)Pressure: ±2,5mbar(750-1100mbarabsolute)Acceleration: ±0,15g(25°C)

Storage rate: Temperaturandhumidity: 1/s toevery12h Pressure: 10/s toevery12h Acceleration,Analoginput:50/s toevery12h

Memory capacity: Over2000000measurementparameters

Push-button: SetbookmarkorstartandstoptherecordGeneral MSR145S MSR145W

Size: 20 x 15 x 52 mm  18 x 14 x 60 mm 

Weight:  Approx. 16 g    Approx. 18 g

Sheath material:   PC      Silicon

Medium: Air      Air, water

Inst

ruct

ions

12

Re

ad

er

Se

tup

Vie

we

rO

nli

ne

PC

…M

od

ule

sIn

stru

ctio

nsPower supply:    •Rechargeablelithiumpolymerbattery170mAh •ThebatteryischargedviatheUSBconnection . •Onebatterychargeissufficientforoperationof theunitforseveralmonths (measurementrate1/minute)Interface:    USB

USB connection cable:   Approx .200cmStandards:  TheMSR145complieswithEUDirectiveRoHS/ WEEE . MSR145S: ProtectionClassificationIP60 MSR145W: ProtectionClassificationIP67

Y

Z

-Z

-Y

X

-X

Y

Z

-Z

-Y

X

-X

Inst

ruct

ions

1�

Operating, transport and storage conditions•ProtecttheMSR145fromexcessiveexposuretothesunandothersources

ofheat .Avoidheavyimpacts .•DonotplaceheavyobjectsontopoftheMSR145 .•OnlystoretheMSR145inadry,dust-freeenvironment .

Operating conditions:Temperature: -20°Cto+65°CPressure: 500mbarto2500mbarabsolute

Optimal storage and transportation conditions: Temperature: 0°Cto45°C(idealstorageconditionforthebattery)Humidity: 10-95%relativehumidity,non-condensingBatterychargelevel: NeverstoretheMSR145withadischargedbattery . Theidealchargelevelisa2/3charge(adischarged batteryachievesthischargelevelafterapprox . 2 hours’ charging).•MSR145S: Avoidcontactwithwaterandhumidity .•MSR145W: Relativehumidity:30%to95%max . (storageandtransport10-95%)

Troubleshooting

Problem Possible cause Possible solution

Thetemperatureincreasescon-tinuouslywhentheMSR145iscon-nectedtothePC

ThebatterywarmsupbecausechargingcommenceswhentheMSR145isconnectedtothePC .

WhenmakingtemperaturemeasurementsdisconnecttheMSR145fromthePC .

TheMSRPCprogramsdonotrecognisethecon-nectedMSR12

TheCOMportdriverisnotinstalledcorrectly .

Observethemanufactur-er’s installation instructions http://www .ftdichip .com/

Inst

ruct

ions

1�

Packing listOptions: •Additionalsensors

•Adapterforconnecting furthersensors

WarrantySeewarrantycard .

DisposalTaketheMSR145toamunicipalwastedisposalcentreor return ittoMSRElectronicsGmbH .TheMSR145mustnotbedisposedofinnormaldomesticwaste .

•MSR145SorMSR145W•CDincluding: •Usermanual

•MSRPCsoftware•MSR145USBconnectioncable•Warrantycard

Declaration of conformity

Other PC software

Online

Viewer

Reader

Setup

PC software

1�

Se

tup

Re

ad

er

Vie

we

rP

C…

On

lin

e

PC

16

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

OverviewExternalprocessingofMSR145dataiscarriedoutusingtheMSRPCsoftwareprogramsSetup,Reader,ViewerandOnline .TheMSRPCprogramscanbeusedforallMSRtypes .TheSetup enables the properties of the MSR 145 to be customised to user’s requirements .TheReaderallowstheusertotransfermeasurementparameterstoaWindowsPC .TheViewerisusedtodisplaydatagraphicallyorintableformortoexportitasatextfile(* .csv) .WiththehelpofOnlineuserscanviewmeasurementparametersandcurves“live”onaPC .

Installation of the MSR PC software on a PCInsert the CD containing the MSR PC software into the computer’s CD-ROM drive .Theinstallationprocedurestartsautomatically* .Duringinstallationselect:Run MSR Modular Signal Recorder now .TheMSRsymbol appearsonscreen .IfthePCisnotsetupforautomaticinstallation,proceedasfollows:1 . ClickStart > Run2 . ClickFind > Look in:(settoCDdrive) .3 . SelectthefileInstall_MSR .exeandOpen .4 . IntheRun dialog boxclickOK .5 . Theinstallationprocesswillbegin .6 . Followtheinstructionsandselect:RunMSR Modular Signal Recorder

now .7 . TheMSRsoftwaremaybestartedbyclickingontheMSRsymbol or

viaStart > Programs > MSR > MSR .

PC software

MSRprogramwindow

*Theprogram "InnoSetup" for installing theMSRPCprogramswaswrittenby JordanRussell (www .jrsoftware .org, copyrightJordanRussell) .

VersionnumberofMSRCD

VersionnumbersofMSRPCprograms

1�

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

UninstallingThe software is uninstalled via the computer’s operating system (Programs > MSR>UninstallMSR) .

System Requirements•Windows95orhigher•USBport

1�

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

PreparationBeforeusingtheMSRPCprogramsSetup, ReaderandOnline,thefollowingpreparationsmustbecompleted:•UsetheUSBconnectingcabletoconnecttheMSR145withthePC .•Beforefirstuse:Using opentheMSR program window,selectSettings>

MSR .• Select the rule by which the Setup, Reader and Online programs are to

searchfortherequiredMSR* .

MSRprogramwindow

•Selecttheportatwhichyourequirethesearchtobegin .

•Enterthepathtothedirectory .

•Seefollowingpagefortemplate .

•Selecttherequiredlanguage .

•Customer-specificprograms

*ThiswindowwillappearifaconnectiontoanMSRcannotbeestablishedusingthecurrentrule .

LoaderDialog

1�

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Template

The template, selectedviaSetting >MSR (* .mse),defineswhichsen-sorstheReader readsoutasstandardoraredisplayedinOnline .Thetemplatesetsthecolourofthetrace,thepositioningofitsaxis(left,right)andgivesthesensorsaname(“HUM,T1”isrequiredtobedisplayedas“outsidetemperature”,forexample) .TemplatescanbeproducedonthebasisofexamplescontainedinViewer (->30) .

Example Thetemperaturecurvesarerequiredtobeblueandorientedontheright

handaxisinalldisplaymodes .

1 .AssignrighthandaxisandbluecolourshadestotemperatureinViewer .2 .Saveastemplate(Bluetemp .mse) .3 .Generate new templates for Reader and Online: Select MSR pro-

gramwindow,Settings MSR>Template ,enternewnameandpath(Temperature .mse),thenOpen .

4 .Openthestillblanktemplate(Temperature .mse)using .5 .Import the template that was created in Viewer (Bluetemp .mse) .

Selecttherequiredsensors(tickincheckbox)intheModule columnandconfirmwithAccept .

6 .Editthedisplayedlist:FirstselectasensorintheModule columnandthenchooseEdit .

7 .Changethename“HUM,T1”to“Outsidetemperature”,andAccept .8 .Continuetomakethenecessaryadjustmentsandconfirmthemwith

Accept .

20

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Once the data has been transferred to the PCvarious options are available to the user . Detailsmaybefoundinthetextwindow .

Example: "Automatically generate a text file" In addition to the MSR format file, the Reader creates a text file (* .csv), which can be openedwith programs such as e .g . Microsoft Word orExcel .

UserdefineswhichrecordsaretransferredtothePC,theirfilenamesandtheirlocation .

TransferonlythemostrecentdatarecordloggedwiththeMSR145tothePC .

UserdefineswhichrecordsaretransferredtothePC .

Pre-adjustments - Reader

EntertherequiredoptionsfortheReader**viaSettings>Reader .

**DatarecordsaretransferredfromtheMSR145toaPCusingtheReader .

OncedatatransferiscompletetheReader createsadatarecord(* .msr)fromeachloggedrecord,namesitandsavesitinthecorrespondingdirectory .Thebottom-mostoptionallowstheuser toalter thesuggestedfilenameand loca-tion .

21

Se

tup

Re

ad

er

Vie

we

rO

nli

ne

PC

Pre-adjustments - Online

The functions described on this page are currently not available with theMSR145 .PleasenotetheexpandedSetupfunctions .

EntertherequiredoptionsforOnline*viaSettings>Online .*Online allows theuser to view theprogressof themeasurement process

directlyon-screen .

•Select the desiredfrequency with whichmeasured parametersaretobetransferredtothePC .

•OnceOnline isstartedthe measured para-meters of all availablesensors are displayedonscreen .

Completion of the preparatory measures

UponexitingSettingsthePCsavesthesettingsthatwerelastentered .ThedefaultsettingscanbereinstatedbyselectingSettings>MSR >Default .

Onceentryofthesettingsiscomplete,selectPrograms andstarttherequiredprogram .

Note: The following instructionsassume that thepreparations forusing theMSRPCprogramshavebeencompleted .

•Thisfunctionisnotavailablewith theMSR145 .

22

SetupisusedtoselectthesensorsforwhichtheMSR145isrequiredtosavemeasurementparameters,toenterthemeasurementfrequencyandtosetthebehaviour of the MSR’s memory. In Setupyoucanalsodefinethestarttimefordatarecordingandstopdatarecording .

ThefollowingsubjectsaredealtwithintheSetupchapter:• Basicsettings->23• Conditionalrecordingofmeasurementparameters(limits)->24• Settingthealarm->24• LEDbehaviour->25• TransferringbasicsettingstoseveralMSR145s->25• Settinguptheanalogueinputs->26• Settingthemeasurementrangeoftheaccelerometers->26• Calibratingtheaccelerationsensors->27• Formattingthememory->28

Setup

Se

tup

2�

Se

tup

Basic settings Note: Thispagedescribesthemostcommonlyusedsettings–theBasic set-

tings .Informationonfurthersettingscanbefoundonthefollowingpages .

• Completethepreparations(->18) .• StartSetup(Setupsymbol) .• UnderRead basic settings,readtheconfigurationsavedintheMSR145 .• EdittheBasic settingsaccordingtoyourrequirements .• TransferthenewconfigurationandthestartconditionstotheMSR145with

Write basic settings .

DefinethesensorsfromwhichtheMSR145shouldrecorddata,togetherwiththestoragerateDefinethesensorsfromwhichtheMSR145shouldrecorddata,togetherwiththestoragerate

Exitsetup

Readtheinforma-tionandmeasure-mentparameters

Displaythecurrentmeasurementparametercurvesforallsensors

Currentlynodataisbeingrecorded(inactive)(active:datarecordinginprogress)

Overwriteoldestmeasurementparameterswhenmemoryisfull

Transferstheconfiguration,thestartconditionsandthePCtimetotheMSR145

ReadthebasicsettingssavedintheMSR145

Stopdatarecording

Conditionalrecord-ingofmeasurementparameters->24

->24->26

BlueLEDflashesduringdatarecording( ->25)

->28

2�

Se

tup

Tip for extensive recordingsWhenmakingextensiverecordingsitisrecommendedthatallsensorsthatarenot requiredbe “turnedoff” .Thispreventsunrequiredmeasurementparam-etersfrombeingsaved .• UnderBasic settings turn"off"allunusedsensorgroups .• Toturnoffindividualsensorswithinonesensorgroupproceedasfollows:

Setthecut-inconditionsuchthattheyarenotactivatedduringtheplannedrecording(e .g .>200°C) .

Conditional recording of measurement parameters (limits)Ifforexample,yourequireonlytorecordtemperaturesgreaterthan20°C,usethefollowingprocedure

Setting the alarmTheMSR145candisplayanalarmifacertainmeasurementparameterdropsbeloworexceedsacertainvalue .When thealarmconditionoccurs the redLEDflashesonceperseconduntilthedatarecordingisstopped .Inputtingthealarmconditioniscarriedoutinthesamewayassettingthecut-in conditions (seesectionConditional recording of measurement param-eters) .EnterthealarmconditionsintheAlarm LimitandLimitcolumns .

1

2

•Enterthecut-inconditionsforthesensorintheRecordLimitandLimitcolumns .

•ReturntotheBasic settingswithandclickWrite basic

settings .

•ActivateLimitsactive1andthecor-respondingtemperaturesensor2 .

TheLimitstabopens .

ReadthelimitssavedintheMSR145

TheMSR145onlyrecordsmeasurementparametersfromthesensorT(p)thataregreaterthan20°C

2�

Se

tup

LED behaviourThebehaviouroftheblueLEDisdefinedviaSetup>Basic settings .

Situation Behaviour of the blue LEDStarttimehasbeentransferredtotheMSR145(nonfuzzy)

First5seconds

Double-flashes5timesat1-secondintervals

WartenaufStart(scharf) Double-flashesat5-secondintervals

Datenaufzeich-nungläuft

First5seconds Flashes5timesat1-secondintervals

After5sec-onds LEDflasheswitht1 LEDdoes

notflash

Transferring basic settings to several MSR 145sUsethefollowingproceduretotransferbasicsettingsthathavealreadybeeninputtoseveralMSR145s:

• StartSetup .• ConnecttheMSR145tothePC .(IfseveralMSR145sareconnectedto

thePC,selecttheCOMportoftherequiredMSR145) .• EntertherequiredvaluesintheBasic settings tab .• Setthecut-inandalarmconditionsintheLimitstab .• UseWrite basic settingstotransferthebasicsettingstotheMSR145 .• DisconnecttheMSR145justconfiguredandconnectthenextMSR145to

thePC .

Note: It isalsopossibletoconfiguredifferentlyequippedMSR145swithasinglebasicsetting .OneMSR145mayforexample,notbeequippedwithanyanalogue inputs .Thesetupprogram thensimplydoesnotwriteanydatatothesettingssavedintheMSR145forthoseanalogueinputs .

26

Se

tup

Setting up the analogue inputsTheanalogueinputsareconfiguredfromtheUser settingstab .

TodisplaytheconfigurationcurrentlysavedintheMSR145changetotheBasic settingstabandclickonRead basic settings .ThesettingswillnowappearintheUser settingstab .

• IntheUser settingstabsettheanalogueinputsaccordingtoyourrequire-ments .

• UseWrite user settingstotransferthenewsettingstotheMSR145

Note: NotallMSR145shaveanalogueinputs .

Setting the measurement range of the acceleration sensorsThemeasurementrangeoftheaccelerationsensorscanbesetfromtheUser settingstab .

SelecttherequiredmeasurementrangeandthenclickWrite user settings .

Note: To display the measurement range currently saved in the MSR145changeto theBasic settings tabandclickonRead basic settings .ThemeasurementrangewillnowappearintheUser settingstab .

2�

Se

tup

Calibrating the acceleration sensorsDependinguponrequirements,theaccelerationsensorsmayeitherbemanu-allycalibratedor theFactory settingsmaybeactivated fromtheUser set-tings tab .Transfer thenewcalibrationsettings to theMSR145usingWrite user settings .

Resetting calibration to factory settings•SelecttheUser settingstabandclickonFactory settings .•TransferthefactorysettingstotheMSR145withWrite user settings .

Manual calibration•SelecttheUser settingstab

andclickCalibrate .ClickonHelptodisplaythePositionoftheaxes .

•Selectthe2 G measurement range .•HoldtheMSR145sothatthe+Xaxisisorientedvertically-bottom-to-top .•Clickonmeasure1 .•TurntheMSR145over .Nowthe-Xaxisisorientedvertically-bottom-to-

top .•Clickonmeasure 2 .•Repeattheprocedureforthe+Y,-Y,+Zand-Zaxes .

•Selectthe10 G measurement range .•HoldtheMSR145sothatthe+Xaxisisorientedvertically-bottom-to-top .•Clickonmeasure 3 .•Repeattheprocedurecorrespondinglyforthe+X,+Y,-Y,+Zand-Zaxes .•CompletecalibrationbyclickingOK .•TransferthenewcalibrationtotheMSR145withWrite user settings .

Y

Z

-Z

-Y

X

-X

312

2�

Se

tup

DeletesallmeasurementparameterssavedintheMSR145

Formatting the memory

Formatting is used to delete all the measurement parameters saved in theMSR145 .

FormattingtheMSR145iscarriedoutfromtheFormat memorytab .

CAUTION Formattingwilleraseallmeasurementpa-rameterssavedintheMSR145!

2�

With theReader userscanselectively transferdatarecords loggedwith theMSR145 toaPC . Itdoeshowever freemeasurement records thathaveal-readybeenreadoutforoverwriting .

Transferring data records to a PC•Completethepreparations(->18) .•StarttheReader (Readersymbol)

Oncedatatransferhasstarted(Start)alldatarecordssavedontheMSR145canbeover-writtenifrequired,evenifthecircularbufferisdeactivatedinSetup .

•BegindatatransferwithStart .TheoptionsselectedunderSettings>Reader (->20)influencethenextsteps:•UndertheoptionRead selected recordsthefollowingdataentrydialogbox

appears:

•With the option Read selected records and save with “Save dia-log as” under Settings > Reader (->20) the filenames and locationssuggestedbyReader canbeoverwritten .

Once the data records have been saved on the PC a list of files createdappears .

Reader

•Selectthedatarecordstobetransferred .

•ClickOK .

•Datarecordshavingthesamestarttimeare

writtentogetherto onefile .

CAUTION

Re

ad

er

Date(YYMMDD)Serialnumber

Recordingstarttime(HHMMSS)Copynumber

FilenamesallocatedbytheReader

�0

Vie

we

r

ViewerRecordscreatedinReader orOnline maybeviewedandeditedonaPCwiththe Viewer .Themeasurementparametersmaybedisplayedeither ingraphorintableform .

•StarttheViewer (Viewersymbol) .•Openarecord(* .msr)viaFile>Open .

Move traces Withrightmousebuttonhelddown .

Enlarge section Marktherequiredsectionwiththeleftmousebuttonhelddown .SeealsoGraphics>Fixed axis .

Cross-hair Moveaxis: Grabtheaxis,movewithleftmousebutton . Movecentre: Grabthecentre,movewithleftmousebutton .

Traceson/off

Cross-hairon/offLockaxis Autoscaling

Undolastchange

Switchbetweengraphs,tablesandconfiguration

XandYvalues:Cross-hair1,cross-hair2(ThedisplayedYvaluealwaysrelatestotheleft-handaxis)

X-axis=time(seconds)

Differencebetweencross-hairs1&2

Gridlines

TextmodeShiftbetweentexttoolandgraphicsmode

Textcreatedusingthetextmode

�1

Vie

we

r

FileThe File menu is used to Open records , toReopen (Open again) the most recently usedrecordsandtoSave thecurrentlyopenrecordasdisplayed .WithSave time window as themeasurementpa-rametersof thedisplayed timewindowaresaved .(Themeasurementparametersofthehiddentrac-esarealsosaved) .ForfurtheroptionsseeCutter ->37 .

Templateshelptostandardisethedisplays,enableeasyrepetitionwhenreselectingthesamesensorsandthesameprintingformat .

Creating templates:AdjustthedisplaywithGraphandConfiguration andsaveviaFile>Save as template(filetype:* .mse) .

Apply a template to the displayed record: File>Use templatethenselecttherequiredtem-plate(*mse) .

Export Time window as text exports the meas-urementparametersofthedisplayedtimewindowin* .csvformat .Themeasurementparametersofthehiddentracesarealsoexported .ThetracecanbeexportedinBitmap(* .bmp)orasJPEGformat .

Print previewopensapreviewofthetrace/graph .Print openstheprintdialogbox .

Exit closes the Viewer . If changes were madetheuser isaskedwhetherthechangesshouldbesaved .Note:The program saves changes as “Template”(* . mse) . The template is automatically saved inthe record’s directory. Template(* .mse)andrecord(* .msr)havethesamename .Upon Opening a record the Viewer searches forthetemplateassociatedwiththatrecord .Shouldthetemplatenotbelocatedinthesamedirectoryastherecordthenthestandardformatwillbeopened .

�2

Vie

we

r

ViewThe View menu allows measurement param-eters tobedisplayedasaGraph orTable .Alternatively, using Configuration the displaymethod can be customised to the user’s require-ments .GraphGridlinescanbeshownforeachaxis(bottom,left,right) .

Fixed axis simplifies the amount of detail shownwithinatimewindoworrangeofvalues .

•Selecttherequiredsectionwiththeleftmousebut-tonhelddown .Thesectionisdisplayedenlarged .

•Forcloserviewing, lock the timewindow( )orrange of values to the left or right axis ( / ) .Severalaxescanbelocked .

•Withtheleftmousebuttonhelddown,selecttherequired detail . The enlargement is displayedwithoutalteringthetimesegmentorrangeofval-uesofthelockedaxes .

Afurtherclickreleasesthelock .Auto scal clearsalllockedaxes .

UsingthetwoCrosshairs valuescanbemeasuredontheXandYtraces .XandYdifferencescanbeevaluatedwiththesecondcross-hair .TheYvaluesdisplayedarealwaysassociatedwiththeleftaxis .

WithDetailed legendtracescanbeturnedonandoffinthelistofsensors .

The complete record is displayed by selectingAuto scale .Auto scale clearsalllockedaxes .

Undo undoesthelastenlargement .Aslongasthe Configuration dialog is not quitted, Undo

allows the lastchangesmade to thedisplayedconfigurationscreentobeundone .

��

Vie

we

r

Table (Tabelle)Go to time allowsuserstojumpstraighttothelineinthetablewiththerequiredtime .

Jump to beginning of graph causesthetabletojumptothefirstmeasurementvaluesdisplayedinthegraph .

ConfigurationAslongastheConfiguration dialog isnotquit-ted,Undo allowsthelastchangesmadetotheconfigurationscreentobeundone .

Text modeUsing the text mode you can insert texts at anyplace .Byclickingon youcanactivateanddeactivatethetextmode .

Inserttext:•Click on . The viewer displays

"Text1"intheupperleftcorner .•Drag the text field to the desired

place .•Double click on the text field and

enteryourrequiredtext .

Deletetext:•Click with the right mouse button

onthetextfieldandselectDelete .

TextfieldwithXandYvalues:•placethecrosshairs(->32)onyour

chosenpositiontoadoddopttheXandYvaluesyouwouldliketouseinthetextfield .

•Createatextfield(seeabove)andclickontherightmousebutton .

Selectthedesiredrepresentation .

��

Vie

we

rUsingConfiguration >Time axis X,thetimeaxiscanbeannotated,thetimesegmenttobedisplayedcanbeset,andtheIncrementfortheletteringandruled lines, togetherwith theFormat fornumberscanbeentered .AutomaticaxisannotationwithanIncrementof0(zero) .

ThenumberFormatforthedisplayedXandYval-uesisenteredviaConfiguration >Crosshairs .The displayed Y value always relates to the leftaxis .

AslongasConfigurationisnotquitted,userscanundothelastchangesmadetothedisplayedcon-figurationscreenwith .

QuitConfiguration viaGraph orTable .Uponquitting,theViewer savestheconfiguration .

Configuration allowsthedisplaymethodofthemeasurementparameterstobesetwiththehelpoftheconfigurationscreens .

EnteringtitleandfooterinformationisachievedviaConfiguration >General .

The associated sensor name, assignment to theleft or right axis, the colour, line weight and stylecanbesetforeachcurve .

Axis >inactiveallowsthegraphcurvetobeshownorhiddenasrequired .

CAUTION

Depictionofthecurvesusingpoints(Configura-tion >Points/Curves>Yes) requiresmorecomputingpower,possiblyleadingtoproblems .

Undothelastchanges

Quit Configura-tion

��

On

lin

e

Online allows users to view the progress of the measurement parametersdirectlyon-screen .

Procedure:•Completethepreparations->18 .•StartOnline (Onlinesymbol) .•Onlinedisplaysthemeasurementparametersgraphicallyandnumerically .

Online

Turntraceonandoff

ExitsOnline

�6

PC

TheCSV utilitycreatestextfiles(* .csv)fromdatarecords(* .msr) .Thesemaysubsequently be opened and edited in a word processing or spreadsheetapplication .

Creating a text file•StartCSV(MSR Program window>Tools>Csv) .•ClickonStart andselectthedatarecordfromwhichthetextfileistobecreated .

CSV creates a text file (* .csv) and saves it in the corresponding directoryforthatdatarecord .Textfile(* .csv)anddatarecord(* .msr)havethesamename .Note: Ifa template (* .mse)exists for thedata record inquestion,CSV

takesthisintoaccountwhencreatingthetextfile .

Example: Opening a CSV text file with Excel•Starttheword-processingorspreadsheetprogram .•OpentheCSVfileviaFile>Open .•UnderFile type,selectText Files .

CSV

Excelfilewithmeasureddata

Datasource

MSR145name

SerialnumberMSRrevisionnumber

Recordstarttime:Date(Day .Month .Year)andtimeofday(Hr:Min:Sec)ModulesforwhichmeasurementparameterswererecordedModuleversion

TimedifferencebetweenPCtimeandMSR145time(readouttime)ChannelandsensornamesUnitforthedisplayedvalue

Measuredparameters(data)inchronologicalorder

Timeofrecording

��

PC

TheCutter utilitycreatesanextractfromadatarecord(* .msr) .

Creating an extract from a data record•StarttheCutter utility(MSR Program window>Tool>Cutter) .

•Click on Start and select the data record fromwhichtheextractistobecreated .

•Selectthetimewindow .Beginning/End .

•Select the sensors for which the measurementparameters are to be exported to a new datarecordandclickNext .

•Enter the name and directory for the new datarecord .ClickonSave .

Cutter

PC

��

CalcWithCalccurvesfromexistingdatarecordscanbelinkedtoeachotherusingformulaeandsavedasadatarecord(* .msr) .ThesaveddatarecordcanbedisplayedandprocessedintheformofcurvesorasatableusingtheViewer .Templatessimplifytheprocessingofrecurringtasks .

Computing new curves•StartCalc (MSR program window >Tools>Calc)

1 Open data record (data origin) ClickonOpentoopenthedatarecordforwhichyouwanttoperformcal-

culationsonthecurve .Itispossibletoopenmultipledatarecords .2 Create new curves

Fromimported curvesselectthecurvethatyouwanttouseforyourcal-culationsanddragit–withtheleftmousebuttonpressed–totherightintothefieldforcurvestobeplotted .Repeatthisprocedureuntiltherequirednumberofcurvesisshownontheright .

3 Enter formula EntertheformulatobeusedforthenewcurveintotheFormulacolumn .

Forthis,usethecapitallettersontheleft . Exampleforasubtraction:A-C

YouwillfindalistoftheavailablefunctionsattheendofthissectionorunderHelp .

Modify the text for the new curves TheentriesinthecolumnsModule,SensorandUnitcanbemodified .

Opendatarecord

EnterformulaNumberfield

1

2

34

PC

��

Modify the order of the new curvesWiththeleftmousebuttonpressed,dragthenumberfieldtotherequiredposition .

Delete new curvesClickinsidethenumberfieldofthecurvetobedeletedandthenpressthedeletekey .ViaTemplate>Delete plotted curve,allnewcurvescanbesimultaneouslydeleted .

4 Calculating and saving the new curvesClickonCalculatethenenterthenameandsetthedirec-toryforthenewdatarecord .ClickonSave .

Note: Thecurvesaresavedasdatarecords(* .mrs) .ThesavedmeasurementparameterscanbedisplayedandprocessedasacurveorasatablebytheViewer .Intermediatevaluesareinterpolated .

Onlycurvesthatoverlaptimewisecanbecalculated .

Creating a template for processing recurring tasksOnceyouhavecreatedthenewcurvesyoucansavetheirlabels and formulae as a template (* .mse) . (Template >Write) .

Creating new curves using templatesOpentherequiredtemplate(*mse)viaTemplate>Read .Thiswillautomaticallygenerateanumberofnewcurves .Multiple templatesmaybeused togeneratenewcurves .Eachtemplategeneratesanumberofnewcurves .

PC

�0

Operators / brackets+-*/^ Plus,minus,multiply,divide,tothepowerof() Openbrackets,closebrackets

Functionssqrt(no .) Squarerootofthenumberln(no .) Naturallogarithmofthenumber(basee)exp(no .) Raisebasisetothepowerofthenumber

abs(no .) Absolutevalueofthenumbersgn(no .) no .>0:sgn=1

no .=0:sgn=0no .<0:sgn=-1

cos(no .) Cosineofthenumbersin(no .) Sineofthenumbertan(no .) Tangentofthenumberctg(no .) Cotangentofthenumber

arcsin(no .) Arcsineofthenumberarccos(no .) Arccosineofthenumberarctan(no .) Arctangentofthenumberarcctan(no .) Arccotangentofthenumber

sinh(no .) Hyperbolicsineofthenumbercosh(no .) Hyperboliccosineofthenumbertangh(no .) Hyperbolictangentofthenumberctgh(no .) Hyperboliccotangentofthenumber

toggleSgn(no .) Changeseverysecondmeasurementparametersign(plus/minus)

Furtherfunctionsonrequest

PC

�1

ConcatWithConcat(concatenate=tolink)datarecordscanbelinkedtogetherandsavedasanewdatarecord(* .msr) .Thenewlycreateddatarecordcanbedis-playedandprocessedintheformofcurvesorasatableusingtheViewer .

Concatenating several data recordsStartConcat(MSR program window>Tools>Concat)

1

1 Select the data records to be concatenated Open the data records that you want to concatenate by clicking Add .

Notethatthelistmustbeinchronologicalordersuchthattheoldestdatarecordisatthetop .Thereforeeitheropentheoldestdatarecordfirstorsortthelistafterwards(seebelow) .

Sort the list alphabetically UseSorttosortthelistalphabetically . Datarecordsthathaveautomaticallygeneratedfilenames(->29)canbe

chronologicallysortedusingSort .

Modify the data record order Withtheleftmousebuttonpressed,dragthenumberfieldtotherequired

position .

Listofdatarecordstobeconcatenated

2

3

Statuswindow

Datarecord1

p

TimeT2T1T0

Datarecord2

Beforeconcatenation

NewDatarecord3p

TimeT2T1T0Afterconcatenation

Numberwindow

PC

�2

Delete all data records from the list UseDelete alltoremovealldatarecordsfromthelist .

Delete one data record from the list SelectthedatarecordtobedeletedandclickDelete line .

2 Enter the name and directory for the new data record SetthepathtothedirectoryusingBrowseandenterthefilename,oruse

theinputwindowtodothis .

3 Calculating the new data record Start the calculation process with Start . Cancel the calculation with

Stop .Note:

•Concat creates a straight line between the lastdata record of the first curve (T1) and the firstdatarecordofthesecondcurve(T2) .

•If,forthedatarecordstobeconcatenated,therearecurvesthatoverlaptimewiseandthesehavethesamename(samemoduleandsensornameswiththesameunits),thecalculationwillbeabort-edandacorrespondingmessage*willappearinthestatuswindow .

•Ifthemodulenames,sen-sornamesorunitsof thecurvestobeconcatenateddonotcorrespondConcatwill be unable to join thecurvesandwillcreatetwocurves .**

•With Concat you cansuperimpose curves withdifferentmoduleorsensornames .

*Remove overlap Use the Cut utility to create an excerpt from a

datarecordthatdoesnotoverlaptimewisewiththenextdatarecord .

**Modify module names, sensor names and units UsetheCalcutilitytomatchthemodulenames,sensornamesandunits

forthecurves .

pp1 p1

TimeOverlapping

p

TimeNewdatarecord

Sensorp1 Sensorp2p

Time

Sensorp1 Sensorp2

Differentsensornames

p

TimeNewdatarecord

p

TimeDifferentsensornamesandstarttimes

pp1 p1

TimeRemoveoverlap

Newdatarecord3p

TimeT2T1T0StraightlinecreatedbyConcat

PC

��

Output ManagerTheOutput Manageriscurrentlynotavailable .

PrintedinSwitzerland 07 .2007MSR145-BSoftwareversion 1 .6MSRPCprogramsoftwareversion 3 .20Copyright2007MSRElectronicsGmbH

MSR Electronics GmbHOberwilerstrasse16CH-8444HenggartSwitzerland

Tel .+41523162555Fax+41523163521

info@msr .chwww .msr .ch