  • JerroLdSTARLINEJLX Series Line Extenders

    JLX SERIES LINE EXTENDER

    OUTPUT

    TP300B

    XO-36

    HOF-.

    (OPTION) I L

    The 30dBtest points,accessiblethroughthehousing,are built into the line extenderforimprovedaccuracy.Standardmale"G"to female"F" adaptersarerecommendedforfieldreadingswithstandardtestequipment.

    For systemoperationof 350 MHzor less, anoptionalplug-inslopeboard,modelJLP-SLB-350is available.

    Optionalreturnamplifier,ModelJLX-SSis avail-ableandcanbe pluggedinto the mainmoduleto amplifythe5-30MHzsub-channelband.

    DF-.

    (OPT!ON) RET. AMPLIFIER (OPTION)

    SIT-r------------~(OPTION) I I

    I ~ ~ II JXP-.A JXP-.A IL.: .-J

    ~(OPTION)

    L

    HINPUT

    TP

    300B

    TheJLX housingandchassishavebeendesignedto supportoperationupto 1GHzbandwidth.Theamplifierhousingis designedfor maximumheatdissipation;hasa wovenwiregasketbetweenbodyandlid for efficientgroundcontinuityandRF shielding;anda siliconerubbergasketforweatherprotection.Theinputandoutputportshaveextrusionsfor securelyinterfacingcableconnectorswithheat-shrunktubing.

    The amplifier module can be plugged intothe housing in either direction as requiredbysignalflow.

    FEATURES

    DIRECTIONAL COUPLER

    OUTPUT TEST POINT

    OPERATION TO 550 MHz

    CONVENTIONAL AND POWER

    DOUBLING TECHNOLOGIES HIGH OUTPUT CAPABILITY

    INTERCHANGEABLE ACCESSORIES

    AND MODULES

    HOUSING & CHASSIS SUPPORT UP

    TO 1 GHz BANDWIDTH

    CONVENTIONAL MODEL JLX-7-450C

    POWER DOUBLING MODELS

    JLX-6-450P, JLX-7-450P

    JLX-6-550P, JLX-7-550P

    INTRODUCTION

    The" J" seriesof line extendersoffers both

    conventional and power doubling tech-nologies.

    TheJLX-C usesthe latestgenerationof hybridpush-pulltechnologyfor 450 MHzoperation.The JLX-C is intended for use as a typicalfeederlineextender.JLX-C hasincreasedgainfor more economical system design andincludesa highlyefficientswitchmodepowersupplyfor minimumpowerconsumption.

    TheJLX-P line extendersuseadvancedpowerdoubling hybrid technology to provideimproveddistortionperformanceat highout-put levels.Thesepowerdoublingline exten-ders offer high gain performancewith lowpower requirements through the use of ahighlyefficientswitchingpowersupply.

    JLX-* FEATURES

    "J" seriesline extenderssupport60Vpower-ing at input levels as low as 38 volts. Surgearrestors,ModelXO-36,comeinstalledin all Jserieslineextenders.

    Power passingis accomplishedthrough useof CBJ-5circuitbreakersor thealternativeCFJ-

    7A 7 ampfuse.TheCTF-JLXis usedfor thermalcompensationandcanbe utilizedpre-stageorinter-stageto allow for minimizationof noisefigureor distortion,as requiredbyapplication.Theoptionalaccessoriesareorderedseparately.

    All JLX serieslineextendersusetheEQ-*series

    of fixedequalizers,thesameequalizersusedinthe StarlineSX amplifier.Throughthe useofcustomerinstalledDF-* diplexfilters, the JLXcanbe equallyconfiguredfor a varietyof split-bandrequirements.The DF-* diplexfiltersarealsosharedwiththeStarlineSXamplifier.

    ~ GeneraLInstrument

    5-17

  • JerroldSTARLINEJLX Series

    Specifications

    Line Extenders

    PARAMETERS NOTESU/M ..SPECIFICATIONS

    MODEL #--71,2.

    JLX-1-450CJLX-6-450PJLX-1-450PJLX-6-550PJLX-1-550P

    Passband Forward

    MHz50-45050-45050-45050-55050-550

    Return

    5-305-305-305-305-30

    Response Flatness

    dB0.750.750.750.750.75

    Minimum Full Gain

    3dB 33 40343834

    Typical Operating Gain

    4,11dB 28 35293329

    Manual Control RangesGain

    dB0-4 0-40-40-40-4

    Slope

    dB0-8 0-80-80-80-8

    Noise Figure

    3dB 8 8888

    Distortion Characteristics

    4,547 dBmV Output47 dBmV Output47 dBmV Output47 dBmV Output47 dBmV Output

    Composite Triple Beat

    6-dB 63 68696364

    Cross Modulation

    -dB63 68696465

    Single Second Order

    7-dB 72 73737171

    Composite Second Order

    -dB63 64646263

    Hum Modulation

    8-dB 60 60606060

    Return Loss at 75 Ohms

    dB16 16161616

    Power Requirements Input Range

    VAC38-6038-6038-6038-6038-60

    Watts

    Watts14.023.020.023.020.0

    Current @ 60 VAC

    Amps0.350.490.460.490.46

    @ 52 VAC

    Amps0.370.540.490.540.49

    @ 45 VAC

    Amps0.380.580.520.580.52

    @ 38 VAC

    Amps0.410.640.580.640.58

    Power Supply DC Voltage

    VDC24 0.424 0.424 0.424 0.424 0.4

    DC Ripple

    mVpp25 maximum25 maximum25 maximum25 maximum25 maximum

    Ambient Operating Temp. Range

    'C-40 to +60-40 to +60-40 to +60-40 to +60-40 to +60

    AC Bypass Capability

    9Amps 7 7777

    Surge Protection

    XO-36XO-36XO-36XO-36XO-36

    Return Amplifier

    Optional JLX-SSOptional JLX-SSOptional JLX-SSOptional JLX-SSOptional JLX-SS

    Housing

    JLX-HSGJLX-HSGJLX-HSGJLX-HSGJLX-HSG

    Specificationssubjectto changewithoutnotice.

    NOTES:

    1. Line ExtenderElectronics,PowerSupply and Housing. Order Equalizers(EQ-*-*),

    ThermalGainCompensation(CTF-Jl.X), Pads(JXP-*), and ReturnAmplifier

    (Jl.X-SS), Diplex Filters (DF1-*) and ResponseCorrection (RCB-SS) separately.

    2. Models Jl.X-450P & Jl.X-550P are referencedto standardproductwith 450 &

    550 MHz slope boards (respectively)included.

    3. At highest channelwithout Equalizer(EQ-*-*) or ThermalGainCompensation

    (CTF-Jl.X). Gaincontrol rangeset for maximumunit gain.

    4. At 450 MHz with 9 dB slope (50 to 450 MHz). At 550 MHz, with 10 dB slope. With

    Equalizer (EQ-*-*). ThermalGain Compensation(CTF-Jl.X). Gaincontrol set for max-

    imum unit gain.

    5. StandardChannelassignmentsper NCTAtest methods.

    6. Measuredwith C.W.carriers andspectrumanalyzer.

    7. Any combinationof channels.

    8. From60 Hz source, at 7 amps.

    g. 7 amp referencedfor usewith 7 amp fuse (CFJ-7A). 5 ampcapablewith use of 5

    amp Circuit Breaker (CBJ-5).

    10. See Diplex Filter specificationsfor chromadelay.