Measure H2S in GRAINS - Sensidyne Dew... · 2014-07-28 · Title: Who you gonna call_dist Author:...

Post on 02-Apr-2020

1 views 0 download

Transcript of Measure H2S in GRAINS - Sensidyne Dew... · 2014-07-28 · Title: Who you gonna call_dist Author:...

© 2001 Sensidyne, Inc. H&S 4280 Rev A 0109

CUST

OMER

ANN

OUNC

EMEN

TCU

STOM

ER A

NNOU

NCEM

ENT

16333 Bay Vista Dr. • Clearwater, FL 33760 • 800-451-9444727-530-3602 • Fax 727-539-0550 • www.sensidyne.com

®

Technical Questions?Contact our Answer Center at800-451-9444, ext 782

Monitoring for hydrogen sulfide in natural gas just got easier. Sensidyne, Inc. announces two new detector tubes formonitoring for hydrogen sulfide (H2S) in natural gas. The tubes are direct reading with a printed scale in grains ofH2S per 100 cubic feet of gas. There are no more charts or graphs to deal with. The tube reading can be entereddirectly onto the field data sheet.

Hydrogen sulfide occurs naturally in natural gas wells, and it must be removed to meet gas quality standards and tocontrol equipment corrosion. The level of H2S is monitored at the outlet side of the H2S removal process to assurethat the H2S has been controlled to some allowable level. Detector tubes are ideal for this measurement due to theirlow cost, ease of use and intrinsically safe operation.

Low Range H2S Tube No. 120GT

Detector tube No. 120GT has a measuring range of 0.25 to 2.0 grains/100CF at one pump stroke or 0.5 to 4.0grains /100CF at 1/2 stroke (Scale x 2). The color change is from white to pale brown and it has no interference frommercaptans, dimethyl sulfide or dimethyl disulfide. It has a shelf life of two years.

Ultra Low Range H2S Tube No. 120GR

An even lower range tube is also available. Tube 120GR has a measuring range of 0.025 to 0.2 grains/100CF at onepump stroke and 0.05 to 0.4 grains/100CF at 1/2 stroke (Scale x 2). The color change is from pale yellow to pink,and it also has a shelf life of two years.

The tubes are designed for use with the Sensidyne/Kitagawa Model AP-1S precision piston pump that comes fromSensidyne with a lifetime warranty. The system is expandable with direct reading detector tubes available for nearly300 additional applications including mercaptans, carbon dioxide and water vapor dew point, the latter being scaleddirectly in pounds of water per million cubic feet of gas. Detector tubes are also available for H2S in higher ranges,up to 40% by volume.

• Fast and simple field operation

• Cost effective monitoring

• Immediate results eliminate laboratory turnaround time

• Eliminates charts, graphs and mathematical calculationsReads directly in grains of H2S per 100 cubic feet of gas

• Intrinsically safe for hazardous atmospheres

with Improved Natural GasHydrogen Sulfide Tubes

per 100 cubic feetMeasure H2S in GRAINSMeasure H2S in GRAINS