Post on 16-Apr-2017
Macnaught MX
Oval Gear Flow Meters
& MX Series Overview
*
Presentation Overview
Flow meter technologyPositive Displacement - Principle of operation.Ideal applicationsWhat's newIntroducing the new generation MX series Flowmeters.
Flow Meter TechnologiesThere are 4 general groupings by which a flow meter can be categorised, according to the technology adopted. Velocity Inferential Mass Volumetric
Volumetric Flow MeterDirectly measure the total volume of the fluid passing through the pipeOval GearRotaryNutating DiscBi-RotorSpur GearOscillating Piston
Typical ApplicationsVolumetricBatchingDispensingDosingFuel ConsumptionApplications requiring accurate totals
Positive DisplacementFlow Meter
Principle of OperationA precision engineered measuring chamber houses a pair of oval rotors which rotate during flow conditions
Principle of Operation
As the Rotors turn they sweep a measured volume of liquid through the measuring chamber
Measured Volume
Principle of OperationEach of the Rotors are fitted with magnets on the top face.As the Rotor turns the magnet activates a switch which is fixed to a Printed Circuit Board (PCB)This in turn generates a Pulse Output
Principle of OperationOur Sensor Boards (PCB) incorporate two types of switches. Reed Switch Mechanical Switch
Hall Effect SwitchSolid State
Calculating Flow RateThe K- Factor is The number of Sensor Pulses per Unit of Measure (Litre or US gallon)Each meter is assigned an individual K-Factor calculated during our calibration checksExample .A meter has an independent K-Factor 36 (= 36 pulses per litre)Each pulse generated by the meter is the equivalent to 1 Ltr 36 = 27.8 mlAn Electronic device (Signal Conditioner) is used to convert these pulse outputs to Flow Rate and Total Flow
The Benefits associated with a PD Meter
Technical Specifications
Accuracy+/- 0.5% (500ml in every 100 litres)
Repeatability 0.03% (30ml in every 100 litres)
Installation and Commissioning
Reliable Robust Easily maintained on site No pipe conditioning required Suitable for variations in medium (e.g. viscosity, concentrations, etc. )
Suitable Applications
Dispensing
RefuellingVehicle ServicingDrum FillingChemical Packaging
Ideal Applications
Servicing and Transfer
Diesel Service Truck
Diesel Service Truck
Diesel Service Truck
Ideal ApplicationsBatching
Chemical Dilution and PackagingFood / BakingAnimal Feed
Automatic Batching
Automatic Filling System
Multiple Drum Filling
Portable Batching System
New application AdBlue metering
Fuel Consumption System
Fuel TankEngineFilterMeter P1
Meter P2
Recirculation Fuel System - Meter Installation - Schematic
MasterReceiving InstrumentFuelFilterNon-ReturnFuel Consumption Valvecalculated asMeter P1 - Meter P2
Ideal ApplicationsHigh Viscosity
Fuels and Lubricants Paints and Coatings Adhesives Printing Ink Cleaning Chemicals
Agricultural Dispensing
The new MX Flowmeter series Pulser range only Manufactured from solid Billet (St.St and Aluminium) Increased Temp (150oC) Pressure Ratings (2000psi) Anodised Aluminium bodyChoice of 9 interchangeable Pulse Output or Display Modules.
M-Lock Mounting System
We have developed a new turn (Bayonet fitting) mounting system for our Pulse Output and Display modules.
Approved for Hazardous AreasIntrinsically Safe (Ex ia)
Flameproof (Exd)
Approved ATEX,
Approved IECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Online ResourcesMacnaught has developed a comprehensive set of web based resources in order to support customers throughout the entire process of selecting, applying and maintaining the MX Flow meter range.http://www.macnaught.com.au/mx_resources/index.html
Automated Flowmeter Selection Tool
Specifications Tool
Conversion Tool (coming soon)
Interactive Web Tools
Online InformationGeneral web based resources
Quick Reference GuidesGeneral Specifications3D DrawingsInstruction ManualsService VideosBrochures
Marketing ResourcesMX Demo Kit
We have developed an MX Demonstration Kit to compliment the launch of the MX series.
table top exhibitionsin-house displaystaff trainingdirect sales tool.
Overview of the new generation MX Series
Flowmeter Range overviewThe range consists of over 1,000 flowmeter models.Process Connection sizes range from to 4 (6mm 100mm)Flow Rates range from 0.0083 1200 l/minStainless Steel and Alum.
Range SegmentationApplication Based Focused on Ideal applicationsFuel and OilSolventIndustrial
All Inclusive PART numberIncludes Flange StylesIncludes displays
Pulser Output and Display Modules
Type ACompact
Compact
Polypropylene HousingIP 67Pulser Output1x Reed switch1x Hall Effect (NPN)
Type BApproved Ex ia
Intrinsically Safe
Stainless SteelPulser OutputNPN Open CollectorApproved Ex iaATEXFMCSAIECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Type CApproved Exd
Flameproof
Stainless SteelPulser OutputNPN Open CollectorApproved ExdATEXIECEx pending
*Note: Ex option only available with the Industrial Flowmeter Series
Display Meter Mount or Wall MountPolypropylene Housing IP677 Digit 12mm upper7 Digit 8mm lowerTotal ResettableFlow RateAccumulated Total (non-resettable)
Type DPR Digital Display
Display Meter Mount or Wall MountPolypropylene Housing IP677 Digit 12mm upper7 Digit 8mm lowerTotal ResettableFlow RateAccumulated Total (non-resettable)
Outputs 4-20mA (passive)Scaled Pulse OutputHi/Lo Flow Alarm
Type EPRA Digital Display
DisplayMeter Mount or Remote MountAluminium housing IP 677 Digit 17mm upper7 Digit 8mm lowerTotal ResettableFlow RateAccumulated Total (non-resettable)
Type FER Digital Display
DisplayMeter Mount or Remote MountAluminium housing IP 677 Digit 17mm upper7 Digit 8mm lowerTotal ResettableFlow RateAccumulated Total (non-resettable)
Output 4-20mA (passive)Scaled Pulse
Type GERA Digital Display
DisplayMeter Mount or Remote MountAluminium housing IP 677 Digit 17mm upper7 Digit 8mm lowerTotal ResettableFlow RateAccumulated Total (non-resettable)
Output 4-20mA (passive)Scaled Pulse
Type HERB Batch Controller
Type THigh Temperature
Intrinsically Safe
Stainless SteelPulser OutputNPN Open CollectorMax temp 150oC
Accessories
Flanged Process ConnectionsFlanges are now screwed into the Meter bodyAvailable in ANSI, DIN, JIS
Wall Mount AdaptorsAluminium wall mount adaptors available for models MX06-25
Strainers / Air EliminatorsA variety of SS Y-Strainers, and Air Eliminator/Strainer combinations are available.
Turck Cables2mtr cables to suit Ex ia and High Temp Pulser switches
Thank You+44 (0)1280 817304 sales@bellflowsystems.co.uk www.bellflowsystems.co.uk