Post on 26-Jul-2018
Spin-on Filters
Maxiflow Series
Typical Applications
Telescopic handlersRefuse vehiclesRoad sweepersCompactorsIndustrial power unitsGrass cuttersPress brakes
The Parker Filtration Maxiflow Full FlowFilters for Suction or Return.Maxiflow type MXA8 and MXA9 feature twointegral red/green indicators incorporated into thehead. Fitted as standard, they ensure maximumindicator visibility and early warning of filtercondition.
Maxiflow type MXA7 features one integral indicator.
Features & Benefits
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 7
62
Features
Integrated indicator
High quality paint for canisters
Spin-on filters available for suctionand return line filtration
High quality filter medium
Advantages
Compact and robust durable construction
Long term protection against corrosion
Flexible product offering
Filter medium suitable for fatigue load due tohigh frequent flow fluctuation
Benefits
Easy identification of element status
Improved protection of filter medium
Standardisation of components
Extended element life time
Circuit symbol
Low pressure filters
Installation Details
Specification
Preferred Series MXA PS SeriesMaximum working pressure: 10 bar 10 barFilter head material: Aluminium LM24 Aluminium alloyFilter bowl material: Steel SteelSeal material: Nitrile Buna (nitrile)Operating temperature range: -30°C to +90°C -30°C to +110°CBypass: Return line 1.05 bar Return line 1.5 bar
Suction line 0.17 bar Suction line 0.10 barNo bypass option No bypass option
Fluids: Mineral oils Mineral oilsElement media: Microglass III media Microglass III media
Cellulose media Cellulose media
63
F
C
DB
20
Minimum for elementremoval
G
H
M
2 mounting holes‘L’
K
ØJ
Filter selectionTo select the correct filter use the appropriatepressure drop graphs. For details and an exampleof how to select the correct filter, see next page.
A
Element removalclearance
D12
PS-1
522
PS-2
0
C
B
A
F
Inlet
KH
L
MXA.8/MXA.9*** 12PS/22PS MXA.7***
Type
G3/4
G11/4
G11/2
19(0.75)
22(0.86)
30(1.18)
28(1.10)430
(16.93)
147(5.79)165
(6.49)179
(7.04)208
(8.19)179
(7.05)
173(6.81)187
(7.36)213
(8.38)236
(9.29)214
(8.42)
95(3.74)
95(3.74)133
(5.24)133
(5.23)140
(5.51)
97(3.82)
N/A
129(5.08)
N/A
N/A
38(1.49)
38(1.49)
50(1.97)
50(1.97)
65(2.56)
94(3.7)93
(3.66)127(5.0)130
(5.12)127(5.0)
88(3.46)107
(4.21)130
(5.12)
N/A
M8 x1.25 x 16full depth
M10 x 1.5
72(2.83)
N/A
72(2.83)
N/A
MXA.8
12PS
MXA.9
22PS
MXA.7
A B C D F G H J K L M
J
Minimum forelement removal
102 (4.01)70
(2.75)Minimum forelement removal
20(0
.79)
DC123 (4.84)
20(0
.79)
2 mounting holes‘L’
70
F
HØ129
A
2 ports 1/8” BSPT foroptional indicators
Ø54
(2.1
2)B
Spin-on Filters
Maxiflow SeriesPressure Drop Curves
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 7
64
Filter Housing
Maxiflow (MXA.8*** Series) and 12PS Series
0
0.2
0.4
0.6
0.8
1.0
0 10 20 30 12011010040 50 60 70 80 90
Flow (l/min)
Δp
(ba
r)
Flow (US GPM)
0 3 8 11 165 13 18 21 24 26 29Δ
p(P
SID
)
0
2.9
14.5
11.6
8.7
5.8
31
0
0.1
0.2
0.3
0.4
0.5
0 10 20 30 12011010040 50 60 70 80 90
Flow (l/min)
Δp
(ba
r)
Flow (US GPM)
10µ Abs
10µ Nom
0 3 8 11 16 315 13 18 21 24 26 29
Δp
(PS
ID)
0
1.5
7.3
5.8
4.4
2.9
Filter Element
Filter Housing
Maxiflow (MXA.9*** Series) and 22PS Series
0
0.1
0.2
0.4
0.3
Δp
(ba
r)
0 80 200 220 24018016014012010020 40 60
Flow (l/min)
Flow (US GPM)
0 5 16 21 3111 26 37 42 47 53 58
Δp
(PS
ID)
0
1.5
5.8
4.4
2.9
61
0 10020 40 60 80 200120 140 160 180 220 240
Flow (l/min)
0
0.2
0.4
0.6
0.8
1.0
Δp
(ba
r)
10µ Abs
Flow (US GPM)
0 5 16 21 3111 26 37 42 47 53 58
Δp
(PS
ID)
0
2.9
14.5
11.6
8.7
5.8
64
10µ Nom
Filter Element
Filter Housing
Maxiflow (MXA.7*** Series)
0
0.1
0.3
0.4
0.6
Δp
(ba
r)
0.7
0.5
0.2
0 100 200 300 40050 150 250 350
Flow (l/min)
Flow (US GPM)
0 26 5313 39 66 79 92
Δp
(PS
ID)
0
2.9
10.2
8.7
7.3
4.4
106
5.8
1.5
1000 40050 150 300 3502502000
0.1
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Flow (l/min)
Δp
(ba
r) 10µ Abs
Flow (US GPM)
0 13 26 39 53 66 79 92
Δp
(PS
ID)
0
1.5
11.6
8.7
7.3
4.4
106
10.2
5.8
2.9
10µ Nom
Filter Element
The recommended level of the initial pressure drop for low pressure filters is max 0.5 bar.If the medium used has a viscosity different from 30cSt, pressure drop over the filter can be estimated as follows:!p = (!p30 x viscosity of medium used) / 30cSt.
Note: All above data is calculated at 30cSt Rel density 0.856.
Low pressure filters
Ordering Information
65
MXAPS
MXA855142412PS10BTV1R2B
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicators MXR8550G3/4
10 micronabs.7010
MXA.8*** & 12PS Return Line Filters
Type Part number DescriptionMAOP Flow Media
PortsReplacement
(bar) (l/min) rating element
MXA MXA9561424 Assembly with bypass & dual visual indicators MXR9560G11/43 micron
abs.3010
MXA.9*** & 22PS Return Line Filters
MXA.7*** Suction Line Filters
MXA MXA7551424 Assembly with bypass & dual visual indicators MXR9550G11/210 micron
abs.30010
MXA.7*** Return Line Filters
MXA MXA7511424 Assembly with bypass & dual visual indicatorsMX1591410
(x4*)G11/210 micron
nom.35010
MXAPS
MXAPS
MXA851122312PS10CTV1S4BMXA851022312PS10CTV1SX4B
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly without bypass, with dual visual indicatorsAssembly without bypass, with gauge type visual indicator
MX1518410(x4*)
G3/410 micron
nom.2010
MXA.8*** & 12PS Suction Line Filters
MXAPS
MXAPS
MXA951122322PS10CTV2S4DMXA951102322PS10CTPSX4D
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly without bypass, with visual indicatorsAssembly without bypass, no indicator
MX1591410(x4*)
G11/4
10micronnom.
4810
MXA.9*** & 22PS Suction Line Filters
MXAPSPSPS
MXA951142422PS10CTV1R2D22PS10CTE2R2D22PS10CTPR2D
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator
MX1591410(x4*)
G11/4
10micronnom.
18010
MXA
PS
MXA851142412PS10CTV1R2B12PS10CTE2R2B12PS10CTPR2B
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorsAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator
MX1518410(x4*)
G3/410 micron
nom.7010
3 Micron abs. filtration for Off-Line and Bypass System Clean UpMaxiflow 3 micron elements are ideal for off-line or bypass clean up applications. These can be specified for the 9*** and 7*** series return line filters
The Maxiflow Series 7*** can be specified with additional visual or electrical indicators. Please consult Parker Filtration for details
Note: Elements marked with (x4*) are only available in packs of 4
MXAPSPSPS
MXA955142422PS10BTV1R2D22PS10BTE2R2D22PS10BTPR2D
Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorsAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator
MXR9550G11/4
10micronabs.
18010
MXAMXA7551223MXA7551023
Assembly with bypass & visual indicatorsAssembly without bypass with visual indicators
MXR9550G11/210 micron
abs.8010
MXAMXA7511223MXA7511023
Assembly with bypass & visual indicatorsAssembly without bypass with visual indicators
MX1591410(x4*)G11/2
10 micronnom.8010
High Pressure Filters
15P/30P SeriesFeatures & Benefits
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12
96
The Parker Filtration 15P/30P SeriesHigh Pressure Filters.These application examples have one thing incommon...the need for clean hydraulic fluid.
Modern high pressure hydraulic systems aredemanding. Better controls and long componentlife are expected. To deliver the high standards ofperformance, hydraulic components are built withtighter tolerances which increases their sensitivityto contamination.
That’s where Parker pressure filters come intoplay. They filter out ingressed contamination beforeit jams a valve or scores a cylinder. They blockpump generated debris before it gets to servoor proportional valves. Parker pressure filtersare a key ingredient in meeting today’s systemdemands.
Put your hydraulic systems in the care of ParkerFiltration. We are committed to designing andbuilding the best filters available to industry.
Features
Compact aluminium housing
Two head sizes and two bowllengths
Large ports and wide flow paths
Microglass III replacement elements
Visual, electrical and electronicindicators available
Advantages
Light weight but still robust design
Optimised sizing
Low differential pressure across housingand element
Multi-layered design produced high capacityand efficiency
Wire support reduces pleat bunching, keepsperformance consistent
Check element condition at a glance
Right style for the application
Benefits
Reliable and continuous operation bothin mobile and industrial applications
Efficient filtration
Right filter for each application
Higher flow rates possible
Less lost energy
Great performance value
Reliable performance throughoutelement life
Reduces downtime, maximiseselement life
Optimise element life, prevent bypassing
Matches your system electricalconnections
Typical Applications
Saw millsAircraft ground support equipmentAsphalt paversHydraulic fan drivesPower steering circuitsDomestic refuse vehiclesCement trucksServo control protectionLogging equipment
High pressure filters
Installation Details
Specification
Pressure ratings:Maximum allowable operating pressure 207 bar.Filter housing pressure pulse fatigue tested: 138 bar.Connections:Inlet and outlet connections are threaded.Connection style Model
15P 30PBSPF(G) 3/4” 1”ISO 6149 M27 M33
Filter housing:Head material extruded aluminium (anodised 6061-T6).Bowl material impacted aluminium (anodised 6061-T6).Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve:Opening pressure 3.5 bar.Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889.
Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved(ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap materialreinforced composite and metal inner core. Collapse rating 24 bar(ISO 2941).High collapse elements:High collapse elements available. For details please contactParker Filtration.Indicator options:Indicating differential pressure: 2.5 ± 0.3 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 215P 1.6 2.130P 2.9 3.9Fluid compatibility:Suitable for use with mineral and vegetable oils, and somesynthetic oils. For other fluids, please consult Parker Filtration.
97
Bottom View
64.32.53
23.9.94
49.01.93
155.36.11
15P-1
15P-1
173.5-2.36.83-0.9
50.82.00
Minimumcartridge removal
clearance
Optional 5/16 SAE-5drain porttorque 20-27 Nm(15-20 ft lbs)
Torque 40-48 Nm
Torque 74-95 Nm(55-70 Ft lbs)
101.64.0023.0
.91
50.51.99
46.01.81
79.431.3
Dia.
21.8.86
25.41.000
62.52.46
6.22.25
250.49.86
15P-2268.7–.2.310.58–.09
15P-2
6.8–.13.266–.005
79.4–.133.125–.005
15P Series
High Pressure Filters
15P/30P SeriesInstallation Details (cont.)
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12
98
1 Head2 Bypass assembly3 Element See chart in product configurator4 Bowl O-ring – buna N92138 N92151
Bowl O-ring – fluoroelastomer V92138 V921515 Bowl6 Drain plug – c/w buna seal
Drain plug – c/wFluoroelastomer seal
7 Nameplate10 Blank indicator kit11 Indicators
M3 – Visual auto reset indicator FMUM3KVAU14MT1 – Electrical indicator FMUT1KVAU14MF1 – Electronic indicatorPNP with 4 LED FMUF1KVAU14MF2 – Electronic indicatorNPN with 4 LED FMUF2KVAU14M
Index Description 15P 30P
66.72.63
90.13.55
Torque 74-95 Nm (55-70 Ft lbs)
3.0.12
51.42.02
210.08.27
30P-1 30P-1
229.69.04
Torque 88-95 Nm(65-70 Ft lbs)
Optional str thd drain port5/16 SAE-5 (11/2-20 UNF-2B)Torque 20-27 Nm (15-20 Ft lbs)
101.64.00
Minimumcartridgeremoval
clearance
Side view
69.92.750
34.91.375 10.3
.406dia thru 2 total
19.1.75
31.81.25
Optional mounting bracket (925563)
101.64.000
Port to port
52.32.06
92.13.63
dia
28.81.12
Hex
Bottom view104.84.13
dia
24.4.96
338.813.34
30P-2
75.22.96
319.312.5730P-2
mm(inches)
30P Series
1
2
3
4
5
6
6
5
4
3
1
7
10
11
High pressure filters
Pressure Drop Curves
99
The recommended level of the initial pressure drop is max. 1.2 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:!p = (!p30 x viscosity of medium used) / 30 cSt.
15P-1 Elements
15P-2 Elements
15P Empty Housing
25
20
15
5
0
10
Flow (US GPM)
Flow (l/min)
20 40 600.0
Δp
(ba
r)
0.5
1.0
1.5
0
10 15 20 2550
80 100
02Q
05Q
20Q
10Q
Δp
(PS
ID)
Δp
(ba
r)
0 20 40 60 80
Flow (l/min)
Flow (US GPM)
Δp
(PS
ID)
0 5 10 15 20 2525
20
15
10
5
0
1.5
1.0
0.5
0.0
15P-115P-2
25
20
15
5
0
10
Flow (US GPM)
Flow (l/min)
20 40 600.0
Δp
(ba
r)
0.5
1.0
1.5
0
10 15 20 2550
80 100
02Q
05Q
20Q10Q
Δp
(PS
ID)
30P-1 Elements
30P Empty Housing
25
20
15
5
0
10
Flow (US GPM)
Δp
(PS
ID)
Flow (l/min)
0.0
Δp
(ba
r)
0.5
1.0
1.5
02Q05Q
20Q
10Q
0 13 26 66
50 100 2502000
53
150 300
39 79
Δp
(ba
r)
0 50 100 150 200
Flow (l/min)
Flow (US GPM)
Δp
(PS
ID)
0 10 20 40 50 6025
20
15
10
5
0
1.5
1.0
0.5
0.0
30P-130P-2
30
30P-2 Elements
25
20
15
5
0
10
Flow (US GPM)
Δp
(PS
ID)
Flow (l/min)
0.0
Δp
(ba
r)
0.5
1.0
1.5
02Q
05Q
20Q
10Q
0 13 26 66
50 100 2502000
53
150 300
39 79
High Pressure Filters
15P/30P SeriesOrdering Information
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12
100
Note: Filter assemblies ordered from the product configurator below are on extended lead times. Where possible, please make your selection from the table above.
Part number
15P110QBM3KG12115P110QBT1KG12115P210QBM3KG12115P210QBT1KG12130P110QBM3KG16130P110QBT1KG16130P210QBM3KG16130P210QBT1KG161
Supersedes
15P-1-10Q-M2-50-B2B2-115P-1-10Q-TW3-50-B2B2-115P-2-10Q-M2-50-B2B2-115P-2-10Q-TW3-50-B2B2-130P-1-10Q-M2-50-C2C2-130P-1-10Q-TW3-50-C2C2-130P-2-10Q-M2-50-C2C2-130P-2-10Q-TW3-50-C2C2-1
Flow(l/min)
45457070120120170170
Modelnumber
15P15P15P15P30P30P30P30P
Elementlength
Length 1Length 1Length 2Length 2Length 1Length 1Length 2Length 2
Mediarating (µ)
1010101010101010
Seals
NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile
Indicator
VisualElectrical
VisualElectrical
VisualElectrical
VisualElectrical
Bypasssettings
3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar
Replacementelements
939102Q939102Q939106Q939106Q939110Q939110Q939114Q939114Q
Ports
G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"
Product configuratorBox 1
Code12
LengthLength 1Length 2
Filter typeBox 2
15PBox 2
1Box 3
10QBox 4
BBox 5
M3Box 6
KBox 7
G12Box 8
1
CodeBV
Seal materialNitrileFluoroelastomer
Seal typeBox 4
Bypass valve3.5 bar
Bypass and indicator settingsIndicator
2.5 barCode
K
Box 6
CodeP
M3T1NF1F2F3F4
Plugged with steel plugVisual indicatorElectrical indicatorNo indicator portElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.
IndicatorBox 5
CodeG12M27G16M33
Connections15P: Thread G3/4
Thread M27, ISO 614930P: Thread G 1
Thread M33, ISO 6149
Filter connectionBox 7
Code14
OptionsStandardDrain port on bowl
OptionsBox 8
Code15P30P
ModelHigh pressure filter, T-portHigh pressure filter, T-port
CodeBox 1
Standard products table
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
Media02Q05Q10Q20Q
Replacement elements with nitrile seals15P-1
939100Q939101Q939102Q939103Q
15P-2939104Q939105Q939106Q939107Q
30P-1939108Q939109Q939110Q939111Q
30P-2939112Q939113Q939114Q939115Q
Filter model15P-115P-230P-130P-2
Nominal flow (I/min) at viscosity 30 cSt02Q254070
120
05Q306090
150
10Q4570
120170
20Q7090
170200
When filter includes a bypass valve but not an indicator,code denotes bypass setting.
Item is standardItem is standard green optionItem is semi standardItem is non standard
123123123123
Highlights Key (Denotes part number availability)
Note: Standard items are in stock, semi standard items are available within four weeks
Box 3
Element media
Microglass III element 20Q10Q05Q02Q
Glass fibreMedia code
Degree of filtration
Average filtration beta ratio ß (ISO 16889) / particle size µm [c]
% efficiency, based on the above beta ratio (ßx)ßx(c)=2
50.0%N/AN/AN/A6
Degree of filtrationCode
ßx(c)=10
90.0%N/AN/A611
ßx(c)=75
98.7%N/A4.58.517
ßx(c)=100
99.0%N/A5918
ßx(c)=200
99.5%N/A61020
ßx(c)=1000
99.9%4.571222
02Q05Q10Q20Q
DisposableMicroglass III
High Pressure Filters
18/28/38P Series
Typical Applications
Injection mouldingDie castingServo controlsMachine toolsMobile equipment
The Parker Filtration 18/28/38P SeriesHigh Pressure FiltersParker Filtration engineered the 18/28/38P series of high pressure filtersto satisfy demanding applications in the mobile and industrial marketsthroughout the world. With metric mounting and optional ISO 6149ports, this new series is truly a global design.
Installed downstream of the pump, this new series with their wide rangeof high capacity Microglass III elements, offer excellent protection tosystem components.
Standard filters come complete with industry proven spool type bypassvalve. For more critical applications such as servo or proportionalcontrols, a no bypass high strength element combination ensuresmaximum protection.
The modular low hysteresis differential pressure indicator fitted to thisseries is unrivaled in its performance. Tests prove its accuracy andfoolproof design to be a major advance in indicator technology.
Features & Benefits
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14
108
Features
Fatigue tested to full pressure rating
Several head sizes
Several connection options
Microglass III replacement elements
Visual, electrical and electronicindicators available
Advantages
Strong and robust housing for heavy dutyapplications
Optimised sizing
Easy mounting
Multi-layered design produced high capacity andefficiency
Wire support reduces pleat bunching, keepsperformance consistent
Check element condition at a glance
Right style for the application
Benefits
Reliable and continuous operation bothin mobile and industrial applications
Efficient filtrationCovers wide flow range
Global design, global acceptanceRight filter for each application
Great performance valueReliable performance throughoutelement lifeReduces downtime, maximiseselement lifeOptimises element life, preventsbypassingMatches your system electricalconnections
18P 28P 38P
B C
Torque22-27Nm
(15-20 ft/lbs)
A Length 1
A Length 2
Hex. E
Bowl removalF
CB
A Length 1
A Length 2
Bowl removalF
Hex.
Torque35-40 Nm
(25-30 ft/lbs)
B C
A Length 1
A Length 2
Bowl removalF
Torque80-95 Nm
(60-70 ft/lbs)
Hex.
K
H
J
LN
M
15°
4 mounting holes (P)
G
H
J
K
LM
N
4 mounting holes (P)
15°R30
R35
G
JH
NM
15°
LK
4 mounting holes (P)
mm(inches)
D DD
G
R38
EE
High pressure filters
Specification
Pressure ratings:Maximum allowable operating pressure 414 bar.Filter housing pressure pulse fatigue tested: 106 pulses 0 - 414 bar.Connections:Inlet and outlet connections are threaded internally or flange faced.Connection style Model
18P 28P 38PBSPF(G) 3/4” 1” 11/4”, 11/2”SAE 12 16 20, 24ISO 6149 M27 M33 M42, M48Flange SAE 6000 3/4” 1” 11/4”Flange SAE 6000-M* 3/4” 1” 11/4”*6000-M is a SAE style with appropriate metric fixing threads.Filter housing:Head material cast iron (GSI).Bowl material steel.Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve & indicator settings:Table below gives bypass valve and corresponding indicator setting.Bypass Indicator3.5 bar 2.5 bar7.0 bar 5.0 bar
109
Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889.Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap material reinforcedcomposite and metal inner core. Collapse rating 20 bar (ISO 2941).High collapse elements:(To be used when no bypass function in filter housing).Microglass III media supported with epoxy coated metal wire mesh onupstream and stainless steel on downstream, end cap material steel.Strong metal inner core. Collapse rating 210 bar (ISO 2941).Indicator options:Indicating differential pressure: 2.5 ± 0.3 bar or 5.0 ± 0.5 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 218P 4.2 5.728P 6.7 9.238P 15.8 20.3Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils.For other fluids, please consult Parker Filtration.
Model
198(7.79)293
(11.53)228
(8.97)337
(13.26)329
(12.95)448
(17.64)
32(1.26)
40(1.57)
44(1.73)
26(1.02)
29(1.14)
35(1.38)
75(2.95)
93(3.66)
128(5.04)
24(0.94)
24(0.94)
36(1.42)
100(3.94)
98(3.86)
120(4.72)
160(6.30)
40(1.57)
55(2.16)
50(1.97)
20(0.79)
27.5(1.07)
25(0.98)
80(3.15)
90(3.54)
120(4.72)
40(1.57)
45(1.77)
60(2.36)
55(2.16)
62(2.44)
81(3.19)
110(4.33)
124(4.88)
162(6.38)
M8 x 1.25x12
deep
M10 x 1.5x11
deep
M10 x 1.5x12
deep
18P-1
18P-2
28P-1
28P-2
38P-1
38P-2
A B C D E F G H J K L M N P(A/F)
High Pressure Filters
18/28/38P SeriesFlange Face Details
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14
110
Modelmm (inches)
11.9
(0.47)
14
(0.55)
15.7
(0.62)
23.8
(0.94)
27.8
(1.09)
31.7
(1.25)
25.4
(1.00)
28.0
(1.10)
33.0
(1.30)
50.8
(2.0)
57.1
(2.25)
66.7
(2.62)
M10 x 1.5-6H x 18 Deep
M12 x 1.75-6H x 20 Deep
M14 x 2-6H x 20 Deep
3/8-16 UNC-2B x 18 deep
7/16-14 UNC-2B x 20 deep
1/2-13 UNC-2B x 20 deep
19.0
(0.75)
25.4
(1.0)
31.8
(1.25)
18P (3/4”)
28P (1”)
38P (11/4”)
A B C D E F G
C
D
AB
ØG
Thread E metricF SAE
High pressure filters
Pressure Drop Curves
111
18P-1 Empty Housing and High Collapse
28P-1 Elements
18P-1 Elements
18P-2 High Collapse Elements
28P-2 Elements
43.5
29.0
0
1150 21
Flow (US GPM)
Flow (l/min)20 6040 120 14010080
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
16
14.5
Δp(P
SID
)
10Q
05Q02Q
160
26 32 37 42
Empty Housing
43.5
29.0
0
1150 21
Flow (US GPM)
Flow (l/min)20 6040 120 14010080
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
16
14.5
Δp(P
SID
)
10Q
05Q
02Q
160
26 32 37 42
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
Δp(P
SID
)
10Q
05Q
02Q
150 300
39 79
43.5
29.0
0
1150 21
Flow (US GPM)
Flow (l/min)20 6040 120 14010080
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
16
14.5
Δp(P
SID
)
10Q05Q
02Q
160
26 32 37 42
18P-2 Elements
43.5
29.0
0
1150 21
Flow (US GPM)
Flow (l/min)20 6040 120 14010080
0.0Δp
(bar
)20Q
1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
16
14.5
Δp(P
SID
)
10Q
05Q
02Q
160
26 32 37 42
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
Δp(P
SID
)
10Q05Q
02Q
150 300
39 79
28P-1 Empty Housing and High Collapse 28P-2 High Collapse Elements
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
Δp(b
ar)
20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
Δp(P
SID
)
10QH05QH02QH
150 300
39 79
Empty Housing
43.5
29.0
0
0 13 26 66
Flow (US GPM)
Flow (l/min)50 100 250200
0.0
Δp(b
ar) 20QH
1.0
2.0
3.0
0
0.5
1.5
2.5
53
14.5
Δp(P
SID
)
10QH05QH02QH
150 300
39 79
With 3.5 bar bypass the recommended initial pressure drop is max 1.2 bar.With 7.0 bar bypass the recommended initial pressure drop is max 2.3 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:The total !p = housing !ph + (element !pe x working viscosity/30).
High Pressure Filters
18/28/38P Series
Element Service
Pressure Drop Curves (cont.)
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14
112
38P-1 Empty Housing and High Collapse
38P-1 Elements
38P-2 High Collapse Elements
43.5
29.0
0
132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
Δp(b
ar) 20Q
1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
106
14.5
Δp(P
SID
)
10Q05Q
02Q
300
7953260 185159
700600
Empty Housing
43.5
29.0
0
132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
Δp(b
ar) 20Q
1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
106
14.5
Δp(P
SID
)
10Q05Q
02Q
300
7953260 185159
700600
43.5
29.0
0
132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
Δp(b
ar)
20Q1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
106
14.5
Δp(P
SID
)
10Q
05Q02Q
300
7953260 185159
700600
38P-2 Elements
43.5
29.0
0
132
Flow (US GPM)
Flow (l/min)100 200 500400
0.0
Δp(b
ar)
20Q
1.0
2.0
3.0
3.5
0
0.5
1.5
2.5
106
14.5
Δp(P
SID
)
10Q
05Q
02Q
300
7953260 185159
700600
A. Stop the system’s power unit.B. Relieve any system pressure in the filter line.C. Drain the filter bowl if drain port option is provided.D. Rotate the bowl clockwise (left) and remove.E. Remove element by pulling downward with a
slight twisting motion and discard.F. Check bowl o-ring and anti-extrusion ring for
damage and replace if necessary.G. Lubricate element o-ring with system fluid and
locate element in filter head.H. Install bowl by rotating counter-clockwise (right)
and tighten to specified torque.18P - 22-27 Nm (16-20 ft. lbs.)28P - 35-40 Nm (25-30 ft. lbs.)38P - 80-95 Nm (60-70 ft. lbs.)
I. Confirm there are no leaks after poweringthe system.
Head AssemblyElementBowlIndicatorsM3 – Visual auto reset; 2.5 barM3 – Visual auto reset; 5.0 barT1 – Electrical; 2.5 bar with
DIN 43650 ConnectorT1 – Electrical; 5.0 bar with
DIN 43650 ConnectorF1 – Electronic PNP; 2.5 bar with 4 LEDF2 – Electronic NPN; 2.5 bar with 4 LEDF1 – Electronic PNP; 5.0 bar with 4 LEDF2 – Electronic NPN; 5.0 bar with 4 LEDBowl SealBowl Anti-extrusion RingSeal KitsSeal kit 18P (std) – NitrileSeal kit 18P (F3) – FluoroelastomerSeal kit 28P (std) – NitrileSeal kit 28P (F3) – FluoroelastomerSeal kit 38P (std) – NitrileSeal Kit 38P (F3) – Fluoroelastomer
see table onnext page
S04350S04351S04352S04353S04354S04355
123
4
5
67
Index Description Part number
Parts List
6
7
2
1
5 4
High pressure filters
Element Service (cont.)
113
Replacement element part numbers
18P-1G04242G04243G04244G04245G04290G04291G04292G04293
18P-2G04250G04251G04252G04253G04298G04299G04300G04301
28P-1G04258G04259G04260G04261G04306G04307G04308G04309
28P-2G04266G04267G04268G04269G04314G04315G04316G04317
38P-1G04274G04275G04276G04277G04322G04323G04324G04325
38P-2G04282G04283G04284G04285G04330G04331G04332G04333
Model02Q05Q10Q20Q
02QH05QH10QH20QH
Elements with Nitrile seals
18P-1G04246G04247G04248G04249G04294G04295G04296G04297
18P-2G04254G04255G04256G04257G04302G04303G04304G04305
28P-1G04262G04263G04264G04265G04310G04311G04312G04313
28P-2G04270G04271G04272G04273G04318G04319G04320G04321
38P-1G04278G04279G04280G04281G04326G04327G04328G04329
38P-2G04286G04287G04288G04289G04334G04335G04336G04337
Model02Q05Q10Q20Q
02QH05QH10QH20QH
Elements with Fluoroelastomer seals
Ordering Information
Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.
Part number
18P110QBT1MG12118P110QBM3MG12118P120QBT1MG12118P120QBM3MG12118P210QBT1MG12118P210QBM3MG12118P220QBT1MG12118P220QBM3MG12128P110QBT1MG16128P110QBM3MG16128P120QBT1MG16128P120QBM3MG16128P210QBT1MG16128P210QBM3MG16138P110QBT1MG20138P110QBM3MG20138P120QBT1MG20138P120QBM3MG20138P210QBT1MG20138P210QBM3MG20138P220QBT1MG20138P220QBM3MG201
Supersedes
18P-1-10Q-TW6-98-B2B2-118P-1-10Q-M2-98-B2B2-118P-1-20Q-TW6-98-B2B2-118P-1-20Q-M2-98-B2B2-118P-2-10Q-TW6-98-B2B2-118P-2-10Q-M2-98-B2B2-118P-2-20Q-TW6-98-B2B2-118P-2-20Q-M2-98-B2B2-128P-1-10Q-TW6-98-C2C2-128P-1-10Q-M2-98-C2C2-128P-1-20Q-TW6-98-C2C2-128P-1-20Q-M2-98-C2C2-128P-2-10Q-TW6-98-C2C2-128P-2-10Q-M2-98-C2C2-138P-1-10Q-TW6-98-D2D2-138P-1-10Q-M2-98-D2D2-138P-1-20Q-TW6-98-D2D2-138P-1-20Q-M2-98-D2D2-138P-2-10Q-TW6-98-D2D2-138P-2-10Q-M2-98-D2D2-138P-2-20Q-TW6-98-D2D2-138P-2-20Q-M2-98-D2D2-1
Flow(l/min)
8080100100130130150150120120150150250250340340420420560560700700
Modelnumber
18P18P18P18P18P18P18P18P28P28P28P28P28P28P38P38P38P38P38P38P38P38P
Elementlength
Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2
Mediarating (µ)
10102020101020201010202010101010202010102020
Seals
NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile
Indicator
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
ElectricalVisual
Bypasssettings
7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar
Replacementelements
G04244G04244G04245G04245G04252G04252G04253G04253G04260G04260G04261G04261G04268G04268G04276G04276G04277G04277G04284G04284G04285G04285
Ports
G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"G1"G1"
G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"
Standard products table
Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14
114
High Pressure Filters
18/28/38P SeriesOrdering Information (cont.)
Product configuratorBox 1
Code12
LengthLength 1Length 2
Filter typeBox 2
38PBox 2
1Box 3
10QBox 4
BBox 5
M3Box 6
MBox 7
G20Box 8
1
CodeBV
Seal materialNitrileFluoroelastomer
Seal typeBox 4
Bypass valve3.5 bar7.0 barNo bypassNo bypass
Bypass and indicator settingsIndicator
2.5 bar5.0 bar5.0 bar
No indicator+ Box 8: code 2+ Box 8: code 2
CodeKMMX
Box 6
CodeN
M3T1PF1F2F3F4
No indicator portVisual indicatorElectrical indicatorPlugged with steel plugElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.
IndicatorBox 5
Code12
OptionsStandardNo bypass
OptionsBox 8
Code18P28P38P
ModelSmall size high pressure filter, T-portMedium size high pressure filter, T-portLarge size high pressure filter, T-port
CodeBox 1
CodeG12S12M27H12F12G16S16M33H16F16G20G24S20S24M42M48H20F20
Ports18P: Thread G 3/4
Thread SAE 12Thread M27, ISO 6149SAE flange 3/4" 6000-MSAE flange 3/4" 6000
28P: Thread G 1Thread SAE 16Thread M33, ISO 6149SAE flange 1" 6000-MSAE flange 1" 6000
38P: Thread G 1 1/4
Thread G 1 1/2
Thread SAE 20Thread SAE 24Thread M42, ISO 6149Thread M48, ISO 6149SAE flange 1 1/4" 6000-MSAE flange 1 1/4" 6000
Filter connectionBox 7
Filter model18P-118P-228P-128P-238P-138P-2
Nominal flow (I/min) at viscosity 30 cSt02Q357080
140140320
05Q60
110100200220440
10Q80
130120250340560
20Q100150150300420700
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
When filter includes a bypass valve but not an indicator,code denotes bypass setting.
Item is standardItem is standard green optionItem is semi standardItem is non standard
123123123123
Highlights Key (Denotes part number availability)
Note: Standard items are in stock, semi standard items are available within four weeks
Box 3
Element media
Microglass III elementHigh collapse element
20Q20QH
10Q10QH
05Q05QH
02Q02QH
Glass fibreMedia code
Degree of filtration
Average filtration beta ratio ß (ISO 16889) / particle size µm [c]
% efficiency, based on the above beta ratio (ßx)ßx(c)=2
50.0%N/AN/AN/A6
Degree of filtrationCode
ßx(c)=10
90.0%N/AN/A611
ßx(c)=75
98.7%N/A4.58.517
ßx(c)=100
99.0%N/A5918
ßx(c)=200
99.5%N/A61020
ßx(c)=1000
99.9%4.571222
02Q05Q10Q20Q
DisposableMicroglass III
02QH05QH10QH20QH
High collapseelement