Post on 29-Feb-2020
Reduced Cost of OwnershipLeading Safety Standards Superior Ease of Use
Safe benchtop steam sterilization
Greater awareness of potential hazards. Ever more stringent regulations. Increasing emphasis on “green” facilities and processes. Now more than ever, it’s critical to decontaminate your laboratory's equipment, materials and bio hazardous waste. That’s what the Tuttnauer Company is all about. For more than 80 years, Tuttnauer has been designing and manufacturing a wide range of laboratory sterilization equipment to safe guard you and your lab.
Tuttnauer’s benchtop sterilizers provide a fast, safe, dependable and convenient means of sterilizing liquids, media, instruments, glassware, clothing and waste. The line includes a wide range of models from our economic manually controlled analog models to our electronically controlled models with a built-in printer for GLP-compliant documentation.
All of the above services are offered by the Heidolph Service group at service@heidolph.com
Heidolph Tuttnauer sterilizers for all your applications
Standard Operating Features
•Self-contained design eliminates external plumbing and hardwiring for easy installation
•Simple Operation
•ASME- stamped, 316 L stainless steel chamber ensures long-lasting reliability, durability and high corrosion resistance
•Fast/slow exhaust; fast exhaust allows quick cycle time of solids and slow exhaust prevents media and liquid boil-over
•Closed-door drying system maintains sterility
•Drying cycle removes residual moisture after sterilization
•Continuous pressure purge eliminates air pockets and ensures thorough, even sterilization
•Large-capacity reservoir provides an ample water supply to avoid frequent fill-ups; the water drain in conveniently located on top to allow for quick and easy cleaning of the reservoir
•Automatic shut-off feature saves energy
•One-year warranty
Standard Safety features
•Heat-insulated, double-locking door protects against accidental burns; the door cannot be opened while the chamber is under pressure
•Automatic low water level shut-off prevents damage to the heater elements if there is insufficient water for the sterilization cycle
•Over-temperature cut-off and over-pressure valve ensure safe operation
•UL- and CSA-approved
Tuttnauer Sterilizer Services
All Tuttnauer autoclave sterilizers require general maintenance and cleaning. A sterilizer often requires regulatory compliance at some local, state or federal standard based on the application within the operation of the unit. Our factory trained technicians are here to help provide basic product upkeep and to help support your sterilizer through a variety of services offered below:
•General repair
•IQ/OQ validation
•Validation
•Preventative Maintenance
These economical, manually operated models feature analog controls and gauges for simple operation. If you’re tight on space, the new compact Model 1730M is the perfect choice for your basic sterilization needs.
Every stage of the cycle, including water-fill, heating, sterilization, exhaust and drying, are microprocessor-controlled and com-pletely automatic with these electronic models. The digital display continuously show you temperature, pressure and running time. Four fully adjustable, single-button programs make these sterilizers easy to use and ensure reproducible runs. The hand battery backup ensures that all parameter setting and controls are retained in the event of a power failure.
•Sterilization time to 59 minutes
•Temperature selection from 105°C to 137°C (221°F to 279°F)
•In-line particle filter to protect valves
•Electronic pressure and temperature sensors
•Low-water alarm- sounds when reservoir needs to be refilled
•Standby heating- keeps chamber warm for quicker cycles
•60-minute cycle timer
•Temperature selection from 100°C to 134°C (212°F to 273°F)
•Combination pressure and temperature gauge with peak indicator
Product features
Product features
Ordering Information
023210002
023210053
023210100
023210151
023210304
023210355
023210631
023210479
023210550
P/N DescriptionNumber of Stainless Steel Trays
Chamber Diameter Voltage
Analog M models
Model 1730M
Model 1730M
Model 2340M
Model 2340M
Model 2540M
Model 2540M
Model 3545M
Model 3850M
Model 3870M
3
3
3
3
4
4
2
2
2
7- in
7- in
9- in
9- in
10- in
10- in
12.2- in
15- in
15- in
120V
220V
120V
220V
120V
220V
220V
220V
220V
Ordering Information
023210207
023210258
023210282
023210401
023210452
023210330
023210665
023210487
023210606
023210657
023212005
023212200
023212609
P/N DescriptionNumber of Stainless Steel Trays
Chamber Diameter Voltage
Electronic E models
Accessories
Model 2340E
Model 2340E
Model 2340EA
Model 2540E
Model 2540E
Model 2540EA
Model 3545E
Model 3850E
Model 3870E
Model 3870EA
Printer, for Models 2340E, 2540E, 3850E, and 3870E
Package of 5 rolls printer paper, for EP models
Stand, for all 3850 and 3870 models
3
3
3
4
4
4
2
2
2
2
9- in
9- in
9- in
10- in
10- in
10- in
12.2- in
15-in
15-in
15-in
120V
220V
120V
120V
220V
120V
220V
220V
220V
220V
Economical Analog Sterilizers
Automated Electronic Sterilizers
3
Gesamtkatalog USA 18112013.indd 162-163 19.11.13 17:31
2
EP Models
•EP Models help you meet GLP documentation requirements. These sterilizers have a built-in printer that provides a printed summary at the end of each cycle, documenting temperature, elapsed drying and sterilization times, selected cycle, cycle number, real time and date, as well as any errors or interruptions that may have occurred during the cycle.
Kwiklave Model 2540EAKP
•The Kwiklave Model 2540EAKP cuts sterilization time in half –perfect for fast instrument turnaround. It offers all standard operating and safety features, plus a special quick cycle. Its advanced heating elements reduces the time needed for the autoclave reach optimal sterilization temperature, reducing overall sterilization time by up to 50%.
EA Models
•EA Models are ideal for sterilizing wrapped and sealed instruments. These fully automatic autoclaves are specially designed with preloaded cycles for sterilizing packs, pouches, sealed pipette racks, unwrapped instruments and other contained/wrapped materials. The highly effi cient air-driven pump circulates hot air after the sterilization cycle to ensure thorough drying of samples and to reduce overall drying time.
Environmental Model 2540EPK
•Environmental Model 2540EPK meets EPA guidelines and is perfect for environmental labs. In addition to standard features, it includes an accelerated cycle time and a built-in printer for sterilization cycle validation
Ordering Information
023210215
023210266
023210291
023210410
023210461
023210444
023210380
023210398
023210690
023210495
023210568
023210673
P/N DescriptionNumber of Stainless Steel Trays
Chamber Diameter Voltage
Electronic EP models, with printer
Model 2340EP
Model 2340EP
Model 2340EAP
Model 2540EP
Model 2540EP
Environmental Model 2540EPK
Model 2540EAP
Kwiklave Model 2540EAKP
Model 3545EP
Model 3850EP
Model 3870EP
Model 3870EAP
3
3
3
4
4
4
4
4
2
2
2
2
9- in
9- in
9- in
10- in
10- in
10- in
10- in
10- in
12.2- in
15- in
15- in
15- in
120V
220V
120V
120V
220V
220V
120V
220V
220V
220V
220V
220V
Accessories - Autoclave Door Gaskets
•Fast, convenient and effective way to clean & descale steam sterilizers, including the chamber, reservoir & tubing
•Convenient premeasured packets replace messy liquids, measuring and scrubbing
•Simply sprinkle on packet into the chamber and run. Recommended Every 20 cycles of use or once per week, depending on usage
•Regular use optimizes autoclave function & extends operating life
Chamber BRITE Sterilizer CleanerP/N 023212803
Ordering Information
023213150
023213206
023213257
023212986
023213273
P/N Description
Gasket f/1730 Model
Gasket f/2340 Models
Gasket f/2540 Models
Gasket f/3545 Models
Gasket f/3850 & 3870 Models
Model 1730 Model 2340 Model 2540 Model 3545 Model 3850 Model 3870
Power Supply
Current
Phase
Chamber Volume Gallons
Liters
Chamber Dimension Inches
(Dia. x D) Centimeters
Tray Dimensions Inches
(W x D x H) Centimeters
Overall Dimensions Inches
(W x D x H) Centimeters
Reservoir volume Gallons
(W x D x H) Liters
Minimum Water Gallons
Volume in Reserivoir Liters
Net Weight Pounds
Kilograms
4980 Erlenmeyer 125 ml
Flask Size 500 ml
1 L, short neck
2 L, short neck
500 ml Media Bottle
Bottom Tray to Top of Chamber
Middle Tray
Top Middle Tray
Top Tray
Max. Allowable Working
Pressure (MAWP)
Water Pump Fuse
Air Pump Fuse 120V
220V
Shipping Weight Pounds
Kilograms
Shipping Volume Cubic Feet
m3
Model
1,050 W
11 A
1
2
7,5
7 x 12
17.8 x 30.5
4.7 x 11.6 x 0.8
12 x 29.5 x 2
17 x 16 x 12.5
43.2 x 40.6 x 31.8
0,8
3
0,21
0,8
55
25
5
-
-
-
-
5 in
3 3/4 in
-
-
2.76 bar (40 psi)
1.25 amps
2.0 amps
1.25 amps
1,400 W
12 A
1
5
19
9 x 18
22.9 x 42.7
6.7 x 16.3 x 0.8
17 x 41.5 x 2
20 x 20 x 15
50.8 x 50.8 x 38.1
0,8
3
0,21
0,8
79
36
12
4
-
-
-
6 in
5 in
-
3 in
79
36
9,4
0,27
55
25
6,35
0,18
1,400 W
12 A
1
6
23
10 x 18
25.4 x 45.7
6.7 x 16.3 x 0.8
17 x 41.5 x 2
20 x 20 x 15
50.8 x 50.8 x 38.1
0,8
3
0,21
0,8
106
48
12
4
3
-
9
8 1/8 in
6 in
3 3/4 in
2 1/2 in
106
48
9,4
0,27
2,200 W
13.6 A
1
7,8
34,4
12.2 x 18.5
31 x 46.9
7.8 x 16.1 x 1
19.8 x 40.8 x 2.5
23.5 x 21.5 x 18
29.7 x 54.6 x 45.7
0,8
3
0,21
0,8
132
60
24
10
6
-
12
10 1/4 in
-
-
5 1/8 in
132
60
12,4
0,35
2,400 W
13.6 A
1
17
65
15 x 20
38.1 x 50.8
14 x 20 x 1
35 x 50 x 2.5
26 x 27 x 21
66 x 68.6 x 53.3
1,6
6
0,53
2
196
89
63
12
7
3
15
12 in
-
-
7 3/8 in
196
89
22,2
0,63
2,400 W
13.6 A
1
22
84
15 x 27
38.1 x 68.6
14 x 26 x 1
35 x 67 x2.5
26 x 34 x 21
66 x 86.4 x 53.3
1,6
6
0,53
2
225
102
68
17
10
4
17
12 in
-
-
7 3/8 in
225
102
26,8
0,76
Technical specifi cations
5
Gesamtkatalog USA 18112013.indd 164-165 19.11.13 17:31
4
Technical specifi cationsSterilize larger volumes in less time
Eight models cover a wide range of applications for laboratories in research institutes, universities, pharmaceutical, food, chemical and biotechnological industries. The advanced laboratory line provides a single solution for the full spectrum of sterilization needs including liquids, culture media, instruments, glassware, plastics, pipette tips, biological waste, contaminated media and other laboratory items.
The vertical laboratory autoclaves are top loading autoclaves available in chamber sizes between 31 to 160 liters. ELV models have an advanced microprocessor control panel and chamber made for 316L or 316Ti stainless steel. For life science applications the Heidolph Tutt-nauer line successfully meets the challenges in today laboratories with a fl exible range of features and a sophisticated control system.
Heidolph Tuttnauer Vertical Autoclaves
Advanced Control system for Your Laboratory
•F0 software control- Protect your liquid Media, Save Time, Save Energy: An additional challenge with liquid sterilization is the need to
prevent liquid media exposure to high temperatures for a long time, which may harm the quality of the liquid media. The advanced
F0 optional feature minimizes the time liquids are exposed to high temperatures during sterilization thereby protecting liquid media,
saving your laboratory time and reducing energy consumption
•PID (Proportional Integral Differential) pressure control
•Stores the last 200 cycles in built-in memory
•Up to 6 temperature sensors and 4 pressure sensors can be connected
•30 Identifi cation codes and passwords for access level control
•The controller and software comply with the 21 CFR part 11 standard
•In/Out test (enables technical to check each system component separately)
•Sterilization Temperature range 105°C to 137°C
•Optional Disinfection/Isothermal Temperature Range 60°C to 105°C
•Optional Independent Recording for cross-checking cycle measurements
•Filter replacement notifi cations based on the number of cycles
•Optional Fast Liquid Cooling- The chamber is surrounded by coils that are fi lled with cold tap water to help rapidly cool down the
chamber to a safe temperature, reducing the cycle time and protecting the load by minimizing its exposure to high temperatures
(ELVC Models)
Sophisticated Multi-Color Display
Tuttnauer’s new display uses multi-color display technology. The User Interface (UI) has been redesigned with the following considerations.
•Multi-Color display for easier reading
•Color is used to indicate the stage of the cycle
•Easy operation
•Quick access to important information
•Multiple languages
•Built-in view of historical cycle data
•Graphical display of Temperature and Pressure
Model ELV/ELVC 2840 ELV/ELVC 3850 ELV/ELVC 3870 ELV/ELVC 5075
* For system requirements for ELV/ELVC models contact sales representatives for more information.
*Only Heidolph Tuttnauer Vertical unit that does not require hard lines for water; reservoir is hand fi lled. * Unit is only available in the 3870 series, no other options
Chamber Volume
Chamber Dimensions (Dia. x Depth)
Overall Dimensions (D x W x H)
Voltage requirements
Power requirements
Max Temperature
Chamber Material
Housing/Door Material
Air Suppply Pressure to be
Regulated Bar (psi)
Feed Water Pressure to be
Regulated Bar (psi)
Internal Thermometer
Sample Temberature Probes
Water-sensing Electrode
External Pressure Gauge
Printer
USB
Wire Baskets
Shipping volume (m3)
Shipping Weight
Net Weight
Compressed Air* ELV ONLY
Tap Water*
Mineral Free Water*
Drain*
31 L
28 x 46 cm
44 x 54 x 98 cm
17.3 x 21.3 x 38.58 in
220V/ 50-60 Hz
2.2 KW
135C
Stainless Steel 316 Ti (1.4571)
Stainless Steel 304 L
3-8 (43-166)
2-3 (29-43)
included
set of 2, included
included
included
included
included
set of 2, included
0,21
57kg/125lb
48kg/105lb
62 L
38 x 48 cm
50 x 65 x 76 cm
19.69 x 25.59 x 29.92 cm
220V/ 50-60 Hz, 3-phase
6.0 KW
135C
Stainless Steel 316 Ti (1.4571)
Stainless Steel 304 L
3-8 (43-166)
2-3 (29-43)
included
set of 2, included
included
included
included
included
included
0,56
101kg/222lb
85kg/187lb
1/2” 3-4 Bar, 60 L/min
1/2” 2-3 Bar
1/2” 2-3 Bar
Withstanding temp. of 230 °F min.
85 L
38 x 68 cm
50 x 65 x 96 cm
19.69 x 25.59 x 37.80 cm
220V/ 50-60 Hz, 3-phase
6.0 KW
135C
Stainless Steel 316 Ti (1.4571)
Stainless Steel 304 L
3-8 (43-166)
2-3 (29-43)
included
set of 2, included
included
included
included
included
included
0,56
116kg/225lb
100kg/220lb
160 L
50 x 75 cm
110 x 86.6 x 71.5 cm
43 x 34 x 28 in
230V/ 50-60 Hz, 3-phase
9.0 KW
135C
Stainless Steel 316 Ti (1.4571)
Stainless Steel 304 L
2.8 (40)
2.8 (40)
included
set of 2, included
included
included
included
included
included
1,35
223kg/492lb
190kg/418lb
1/2" 3-4 Bar
1/2" 3-4 Bar
2" Min Withstanding temp
of 8°C (176F)
023210915
023210916
023210920
023210930
023210940
023210950
023210745
023210980
023210990
023211850
023211840
023211790
023211795
023211860
023211870
023211890
023211895
023210745
P/N Description Number of Wire Baskets
Cooling Voltage
Additional Wire Baskets
Additional Solid Baskets, ideal for medical waste sterilizations
Vertical Autoclave 2840 ELV
Vertical Autoclave 2840 ELVC
Vertical Autoclave 3850ELV
Vertical Autoclave 3850ELVC
Vertical Autoclave 3870ELV
Vertical Autoclave 3870ELVC
NEW! Vertical Autoclave 3870ELV Free standing on wheels and mobile
Vertical Autoclave 5075ELV
Vertical Autoclave 5075ELVC
2 (Small)
2 (Small)
2 (Small)
2 (Small)
2 (Large)
2 (Large)
2 (Large)
2 (Large)
2 (Large)
2 (Small)
Yes
Yes
Yes
Yes
NA
220V
220V
208V
208V
208V
208V
208V
230V
230V
220V
Models 3850/3870 Wire Basket, small, 14.06 (dia.) x 8.66 (h) in
Models 3850/3870 Wire Basket, large, 14.06 (dia.) x 13.00 (h) in
Model 5075 Wire Basket, large, 465 x 350mm
Model 5075 Wire Basket, small, 465 x 235mm
Models 3850/3870 Solid Basket, small, 14.41 (dia.) x 8.66 (h) in
Models 3850/3870 Solid Basket, large, 14.41 (dia.) x 13.00 (h) in
Model 5075 Solid Basket, large, 474 x 350mm
Model 5075 Solid Basket, small, 474 x 235mm
NEW! Vertical Autoclave 3870ELV Free standing on wheels and mobile
Gesamtkatalog USA 18112013.indd 166-167 19.11.13 17:31
6 7
*Dimensions and weights are approximate and for reference only.*The addition of certain options could impact the above stated utilities*Contact a Heidolph representative to obtain certifi ed drawings.*Due to continuing equipment development, specifi cations are subject to change without notice*Request an Industrial Checklist from your Heidolph Specialist today
The Heidolph Tuttnauer offers an unmatched range of models that are available in three series: Compact, Mid Range, and Large Capacity. The sterilizer chambers range in volume from 120 to 1015 liters. Additional, we design customer sizes and offer the end-user an unlimited amount of upgrades to choose from. Each model is available in either single or double door confi gurations.
NEW! Large Capacity Autoclaves Specifi cations
44 and 55 Compact Series
Small Laboratory Autoclaves with chamber volumes from 120 to 250 liters.
The 44 and 55 series are available with following door options:
•Fully automatic vertical sliding door
•Manual Hinged Door
We offer 2 different models
66 Mid Range Series
Medium Laboratory Autoclaves with chamber Volumes from 340 to 660 liters.
The 66 series is available with the following door options:
•Fully Automatic vertical sliding door
•Hinged door with automatic locking
We offer 5 different models
69 Large Capacity Series
Large Laboratory Autoclaves with chamber volumes from 510 to 1015 liters
The 69 Series is available with the following door options:
•Fully automatic horizontal sliding door
•Hinged door with automatic locking
We offer 7 different models
Compact & 66 Mid Range Series
Model
Chamber Dimensions WxHxL (Inches)
Chamber Volume Cubit Feet (Liter)
External Dimensions
Cabinet Enclosed
WxHxL (Inches)
Autoclave Weight
Empty Chamber
Lbs (kg)
Single Hinged Door
Single Sliding Door
Double Hinged Door
Double Sliding Door
Single Sliding Door
Double Sliding Door
4472
16x16x28
4 (120)
28x75x51
31x75x46
45x75x46
47x75x46
1100
(499)
1250
(567)
5596
20x20x38
9 (250)
28x75x60
33x75x53
49x75x53
53x75x49
1760
(798)
1910
(866)
66A
24x24x36
12 (340)
43x75x56
40x75x60
58x75x52
60x75x59
2955
(1340)
3205
(1454)
66B
24x24x48
16 (450)
43x75x68
40x75x72
58x75x64
60x75x71
3200
(1451)
3450
(1565)
66C
26x26x39
15 (430)
46x75x71
40x78x67
60x75x66
64x78x69
3150
(1429)
3400
(1542)
66D
26x26x49
19 (540)
46x75x71
40x78x67
60x75x66
64x78x69
3350
(1520)
3600
(1633)
66E
26x26x60
23 (660)
46x75x81
40x78x77
60x75x77
64x78x79
3550
(1610)
3800
(1724)
Utility Consumptions / Requirements
Model
Plant Steam Supply
50-80 PSIG Dynamic
97-100% Dry Sturated
Vapor Condensate
Free
Cold Water Supply 30-
70 PSIG Dynamic, 60-
70°F Contact Heidolph
for Recommended
Water Quality
Building Drain
Compressed Air Requirements
Electrical Requirements (Control System)
Electircal requirements
(Optional Vacuum Pump)
Electrical Requirements
(Optional Steam Generator)
Pipe Size
Flow Rate (Peak)
Pipe Size
Flow Rate
Pipe Size
69A
3/4" NPT
48 Lbs/Hr
Peak 17Lbs/
Cycle Avg.
3/4" NPT
4 GPM
(15L)
208V
3.1A
120V
5.9A
2" ODT
75-95 PSIG Dynamic, 3.5 SCFM. 3/8" NPT
1- Phase, 120V, 50/60 Hz. 20A
Contact a Heidolph representative for specifi c electrical requirements
69A
3/4" NPT
100 Lbs/Hr
Peak 22Lbs/
Cycle Avg.
3/4" NPT
8 GPM
(30L)
208V
3.1A
120V
5.9A
2" ODT
69A
1" NPT
160 Lbs/Hr
Peak 26Lbs/
Cycle Avg.
1" NPT
12.5 GPM
(47L)
208V
7.6A
480V
4.3A
2" ODT
69A
1" NPT
203 Lbs/Hr
Peak 29Lbs/
Cycle Avg.
1" NPT
14 GPM
(53L)
208V
7.6A
480V
4.3A
2" ODT
69A
1" NPT
160 Lbs/Hr
Peak 26Lbs/
Cycle Avg.
1" NPT
13.5 GPM
(51L)
208V
7.6A
480V
4.3A
2" ODT
69A
1" NPT
203 Lbs/Hr
Peak 29Lbs/
Cycle Avg.
1" NPT
15 GPM
(57L)
208V
7.6A
480V
4.3A
2" ODT
69A
1" NPT
246 Lbs/Hr
Peak 32Lbs/
Cycle Avg.
1" NPT
19 GPM
(72L)
208V
7.6A
480V
4.3A
2" ODT
9
Gesamtkatalog USA 18112013.indd 168-169 19.11.13 17:31
8
•The control panel is an advanced microprocessor providing significantly greater accuracy than an electro-mechanical control.
The control is isolated and covered to protect it from heat and moisture damage.
•All Piping is corrosion resistant stainless steel and has unions between components to make maintenance much easier.
You do not have to dismantle large sections of piping just to replace a single part. A design that will minimize any down time.
•Control valves are air driven (pneumatic) and last 4-5 times longer than older style electromagnetic valves
•The chamber and jacket are 100% stainless steel. The jacket is 304 SS and the chamber is 316L SS for superior corrosion resistance
and is very stain resistant for easier maintenance/clean up in event of a spill.
•The chamber is fully insulated to be energy efficient and prevent heat loss and thermal loading of the work area. The Unit must
have a full 2” thickness of rigid, chloride free insulation. This is important in a moisture laden environment. The insulation is then
completely covered with corrosion resistant stainless steel cladding to prevent damage and degradation of the insulation.
Benefits of Choosing Tuttnauer
Specifications
Compact & 69 Mid Range Series
Model
Chamber Dimensions WxHxL (Inches)
Chamber Volume Cubit Feet (Liter)
External Dimensions
Cabinet Enclosed
WxHxL (Inches)
Autoclave Weight
Empty Chamber
Lbs (kg)
Single Hinged Door
Single Sliding Door
Double Hinged Door
Double Sliding Door
Single Door
Double Door
69A
24x36x36
18 (510)
53x75x56
75x75x62
58x75x52
75x75x63
3440 (1560)
3740 (1696)
69B
24x36x48
24 (680)
53x75x68
75x75x74
58x75x64
75x75x75
3770 (1710)
4070 (1846)
69C
24x36x60
30 (840)
53x75x80
75x75x86
58x75x75
75x75x86
4100 (1860)
4400 (1996)
69D
24x36x72
36 (1015)
53x75x92
75x75x98
58x75x87
75x75x98
4500 (2041)
4800 (2177)
69E
26x37.5x36
20 (575)
55x75x56
79x75x62
60x75x52
79x75x63
3640 (1651)
4800 (2177)
69F
26x37.5x48
27 (760)
55x75x68
79x75x74
60x75x64
79x75x75
3970 (1801)
4270 (1937)
69G
26x37.5x60
34 (950)
55x75x80
79x75x86
60x75x76
79x75x87
4300 (1950)
4600 (2087)
Think wise. Think Pure. Think Tuttnauer.PUREWISE water distillers operate by heating water to 212°F (100°C), which kills bacteria, cysts and or viruses that may be present, and converting it to steam. As the steam rises it leaves behind any solids, salts, heavy metals, etc.; low-boiling, light gases are discharged through the gaseous vent. The steam is then cooled in the stainless steel condenser, where it turns back into high quality, pure water. To further enhance water quality, the distilled water passes through a coconut shell carbon filter to extract any volatile organic compounds (VOCs) and is finally deposited in the unit’s GE Lexan polycarbonate collection/storage container.
•Effectively removes most tap water impurities
•East-to-remove boiler for manual fill- no water hookup
•Automatic shut-off after 1-gallon cycle
•Rust-proof stainless steel condenser
•Unique recessed heating base reduces scale buildup
•Includes collector/storage bottle
•UL listing: #28KL
•Water system is 99% free of impurities
•Extra-large capacity
•Benchtop and floor-standing models available
•Front- or side-mounting spout for easy dispensing and storage
•Directly connects to tap water supply for continuous operation
Product features
Additional product features of Model 7000 series
Technical specifications
Model 9000 7000 7000-8 7000-12
Distillate capacity
Power supply
Dimensions
(W x H x D)
Weight
1 gal/3.8L in 4.5h;
up to 5gal/18.9L in 24h
115V/ 60 Hz
9.5 x 15 x 16 in
24.1 x 38.1 x 40.6 cm
10lb/ 4.5kg
3.5 gal/13.3 L in 18h
115V/ 60 Hz
11 x 17 x 17 in
28 x 43 x 43 cm
30lb/ 13.5kg
8 gal/30.4 L in 28 h
115V/ 60 Hz
11 x 36 x 17 in
28 x 91 x 43 cm
37lb/ 16.5kg
12 gal/45.6 L in 30 h
115V/ 60 Hz
11 x 42 x 17 in
28 x 107 x 43 cm
44lb/ 20kg
Ordering information
023211150
023211160
023211170
023211180
023212040
Benchtop water distiller Model 9000
Benchtop water distiller Model 7000
Floor-standing water distiller Model 7000-8
Floor-standing water distiller Model 7000-12
Carbon filter cartridge, for Model 9000, change after every 6 months of use
P/N Description
PUREWISE Water Distillers
Utility Consumptions / Requirements
Model
Plant Steam Supply
50-80 PSIG Dynamic
97-100% Dry Sturated
Vapor Condensate
Free
Cold Water Supply 30-
70 PSIG Dynamic, 60-
70°F Contact Heidolph
for Recommended
Water Quality
Building Drain
Compressed Air Requirements
Electrical Requirements (Control System)
Electircal requirements
(Optional Vacuum Pump)
Electrical Requirements
(Optional Steam Generator)
Pipe Size
Flow Rate (Peak)
Pipe Size
Flow Rate
Pipe Size
69A
1 1/4" NPT
235 Lbs/Hr
Peak 30Lbs/
Cycle Avg.
1 1/4" NPT
18 GPM
(68L)
208V
18A
120V
9.5A
3" ODT
75-95 PSIG Dynamic, 3.5 SCFM. 3/8" NPT
1- Phase, 120V, 50/60 Hz. 20A
Contact a Heidolph representative for specific electrical requirements
69A
1 1/4" NPT
300 Lbs/Hr
Peak 32Lbs/
Cycle Avg.
1 1/4" NPT
20 GPM
(76L)
208V
18A
120V
9.5A
3" ODT
69A
1 1/4" NPT
370 Lbs/Hr
Peak 34Lbs/
Cycle Avg.
1 1/4" NPT
22 GPM
(83L)
208V
18A
120V
9.5A
3" ODT
69A
1 1/4" NPT
435 Lbs/Hr
Peak 36Lbs/
Cycle Avg.
1 1/4" NPT
24 GPM
(91L)
208V
18A
120V
9.5A
3" ODT
69A
1 1/4" NPT
245 Lbs/Hr
Peak 31Lbs/
Cycle Avg.
1 1/4" NPT
18 GPM
(68L)
208V
18A
120V
9.5A
3" ODT
69A
1 1/4" NPT
310 Lbs/Hr
Peak 33Lbs/
Cycle Avg.
1 1/4" NPT
20 GPM
(76L)
208V
18A
120V
9.5A
3" ODT
69A
1 1/4" NPT
380 Lbs/Hr
Peak 35Lbs/
Cycle Avg.
1 1/4" NPT
22 GPM
(83L)
208V
18A
120V
9.5A
3" ODT
11
Gesamtkatalog USA 18112013.indd 170-171 19.11.13 17:31
10
Ordering Information
Tank dimensions
(W x H x D)
External
dimensions
(W x H x D)
Tank capacity
9.4 x 4 x 5.4 in
23.8 x 10.2 x 13.7 cm
12.6 x 8.8 x 9.9 in
32 x 22.2 x 25 cm
0.8 gal/ 3.4 L
9.4 x 4 x 5.4 in
23.8 x 10.2 x 13.7 cm
12.6 x 8.8 x 9.9 in
32 x 22.2 x 25 cm
0.8 gal/ 3.4 L
15.5 x 6 x 9 in
39.4 x 15.2 x 22.9 cm
19 x 13.5 x 16 in
49.3 x 34.3 x 40.6 cm
3.0 gal/ 12.7L
15.5 x 6 x 9 in
39.4 x 15.2 x 22.9 cm
19 x 13.5 x 16 in
49.3 x 34.3 x 40.6 cm
3.0 gal/ 12.7L
Model CSU 1 CSU 1H CSU 3 CSU 3H
Ordering Information
023211055
023211075
023211065
023211085
023212010
023212020
023212050
023212060
023212040
023212030
P/N Description
Ultrasonic baths
Accessories
Model CSU 1, includes bath lid/cover
Model CSU 1H, with built-in heater, includes bath lid/cover
Model CSU 3, includes bath lid/cover
Model CSU 3H, with built-in heater, includes bath lid/cover
CSU 1 spare parts kit, includes beaker holder, 2 glass beakers, bands and beaker lids
CSU 3 spare parts kit, includes beaker holder, 2 glass beakers, bands and beaker lids
CSU 1 sample basket
CSU 3 sample basket
Carbon fi lter cartridge, pkg. of 6
Clean & Simple ultrasonic cleansing tablets, box of 144 tablets
Clean & Simple Ultrasonic Baths
New Clean & Simple ultrasonic baths feature 60kHz of quiet cleaning power, which is less aggressive to instruments, yet strong enough to remove all surface contamination. Systems are available in 1- and 3-gallon sizes for standard glassware and instruments. A full selection of optional accessories are available to meet your specifi c needs. For added samples processing and cleaning power, choose an “H” model. Which features a built-in heating unit.
Fill your ultrasonic bath water and drop in two cleaning tablets. Watch them dissolve and clean in about a minute. The tablets create a non-ionic cleaning solution that is non-corrosive, nontoxic, non-caustic and biodegradable.
•Built-in heater (“H” models) for added sample
processing and cleaning power
•High effi ciency 60 kHz of cavitation for thorough
and quiet cleaning
•Durable vinyl-clad steel housing is easy to
clean and resist scratching
•Stainless steel tank with cover included
•Full line of accessories available
•Eliminates handling of heavy 1-gallon containers
•No bulky storage of premixing
•Enzymatic solution effectively breaks down protein
Use a Reax vortexer in conjunction with anultrasonic bath to help aid in dissolution ofsamples
Ultrasonic bath features Cleaning Tablet features
13
Gesamtkatalog USA 18112013.indd 172-173 19.11.13 17:31
12
Heidolph North America
1241 Jarvis Avenue • Elk Grove Village, IL 60007
Phone 224-265-9600 • Fax 224-265-9611
sales@heidolph.com • www.heidolphNA.com Toll Free 866-650-9604