Post on 28-Mar-2018
CLR STAMP
UHZ STAMP
ENGINEER STAMP
ENGINEER STAMP
ENGINEER STAMP
NEW SUBMITTALRESUBMITTAL
COMMENTS:
DRAWING:
REVIEWED
REVIEWED AS NOTED
REVISE AND RESUBMIT
REJECTED
THIS REVIEW IS FOR GENERAL CONTRACT COMPLIANCE AND DOES NOT RELEASETHE SUBCONTRACTOR AND/OR SUPPLIER FROM COMPLYING WITH THE PLANS,SPECIFICATIONS, SUBCONTRACTOR AND/OR PURCHASE ORDER AGREEMENTS, NORDOES THIS RELEASE THE ARCHITECTS OR CONSULTANTS FROM THEIRCONTRACTUAL RESPONSIBILITIES.
SIRQ SUBMITTAL NO: SPEC. SECTION NO:
BY: DATE:
Subcontractor:
x
ARCHITECTSTAMP
OWNERAPPROVAL
Olympus Gymnastics
03-01
5/9/17Ryan Waite
Tactic Construction
Concrete Mix Design, Grout, Form Release,Vapor Barrier, Cure, Evaporation Retardent
X
RECEIVED05/10/2017
GSBSARCHITECTS
375 W. 200 So., #100, SLC Utah
JBC 5/10/17
GSBS rec'd 05.11.2017
375 WEST 200 SOUTHSALT LAKE CITYUTAH 84101
ARCHITECTURE LANDSCAPE ARCHITECTURE INTERIOR DESIGN PLANNING
FILE: OLY-030000-01 00 - Concrete-sirq-ARW.pdf
Corrections or comments made in the shop drawings during this review do not relievecontractor from compliance with requirements of the drawings and specifications. Thischeck is only for review of general conformance with the design concept of the projectand general compliance with the information given in the contract documents. Thecontractor is responsible for confirming and correlating all quantities and dimensions,selecting fabrication processes and techniques of construction, coordinating his workwith that of all other trades, and performing his work in a safe and satisfactory manner.
Date: 05/11/2017 BY:
REVIEWED
REJECTED
REVISE AND RESUBMIT
FURNISH AS CORRECTED
Kelsey Madden
RETURNED05/11/2017
GSBSARCHITECTS
375 W. 200 So., #100, SLC Utah
5/5/2017 Printing Selections
https://buildertrend.net/Selections/selectionsPrint.aspx?loginType=1&selectionIDs=7744280%2c7744281%2c7744282%2c7744283%2c7744284%2c7744418&sort=1… 1/2
Printdate: 552017Job InfoOlympus Gymnastics Training Center9683 South 500 WestSandy, UT 84070
Owner InfoSIRQ Construction887 West Baxter DriveSouth Jordan, UT 84095
Category:Div 3 SpecsLocation: Concrete Mix Designs
Due Date:N/A
Category:Div 3 SpecsLocation: Concrete Slabs
Due Date:N/A
Category:Div 3 SpecsLocation: Concrete Slabs
Due Date:N/A
Category:Div 3 SpecsLocation: Plywood and Steel Form Materials
Due Date:N/A
Selections DetailsCONCRETE MIX DESIGNSJack B. Parson
Mix Code Description Usage
3325107 3000 NA Footings
3325607S 4000NASuper Interior Slab on Grade
3325604S 4000MASuper Foundation Walls
3326880 5000 AE Titan Exterior Flat Work
CURE & SEALDAYTON SUPERIORCure & Seal 309 J18
EVAPORATION RETARDANTW.R MEADOWS EVAPRE Evaporation Retardant
FORM RELEASEDayton Superior Clean Strip Ultra J3
5253 w 7660 s • west jordan, UT 84081 • Phone: (801) 9534206
SUBMITTALS
5/5/2017 Printing Selections
https://buildertrend.net/Selections/selectionsPrint.aspx?loginType=1&selectionIDs=7744280%2c7744281%2c7744282%2c7744283%2c7744284%2c7744418&sort=1… 2/2
Category:Div 3 SpecsLocation: Grout bed Below Steel Columns
Due Date:N/A
Category:Div 3 SpecsLocation: Slab on Grade
Due Date:N/A
NON SHRINK GROUTICS Construction Grout
High Strength, NonShrink, NonCorrosive Grout
VAPOR BARRIERW. R Meadows PERMINATOR® 15 Mil Underslab Vapor Barrier
Please Note: A signature of Approval OR Electronic Acceptance is required before options are selected.
Approved by:
Date:
89 West 13490 South Draper, Utah 84020
Tactic ConstructionOlympus Gymnastic Training Ceter
Dan:
We are pleased to submit the follow ing concrete mix design for approval on the above referenced project. All of the
materials for this project conform to ACI 301 and ACI 318 Specif ication for Ready Mixed Concrete.
Concrete w ill be delivered per ASTM C-94.
This submittal contains the following mix designs:
Mix Code Description Usage3325107 3000 NA Footings, Grade Beams, Interior Slabs
3325107S 3000 NA Super Footings, Grade Beams, Interior Slabs
3326104S 4500 AE Super Exposed Footings, Grade Beams, Wallls, Site Work
3326880 5000 AE Site Work
Dispatch phone number is (801) 262 1400
When ordering concrete for your project, please have personnel place order using the project name and
designated m ix numbers that are applicable to the usage. The primary plant for this project w ill be 623 and the
backup plant w ill be 619.
NOTE: Evaluation and curing of the concrete m ust be conducted according to all ACI, ASTM, AASHTO or
project standards. We request that all evaluations of concrete be sent to Jack B. Parson Co. w ithin 3
business days. Email all reports to Lisa.Sotherland@stakerparson.com . Jack B. Parson cannot be held
liable for failure to com ply w ith the above listed standards.
Please notify your Sales or QC Representative as to the acceptance or rejection of this mix design submittal. We
appreciate the opportunity to w ork w ith you on this project.
Respectfully,
Jeremy Wilcox
4/25/2017
DATE: 04/25/2017Concrete Mix Design Submittal
No. JW-042517-02 Version 1
PROJECT NAME: Olympus Gymnastic Training Ceter
MIX NUMBER 3325107
3000 NA
PLANT
Mix Description
Footings, Grade Beams, Interior SlabsINTENDED USE:
3000 psiDesign Strength
623ASTM C-94 Options A & C
CUSTOMER: TACTIC CONSTRUCTION
Material Code
Material Supplier
DesignQuantity
Material Description
PTE-#57 SPC POINT EAST #57 ROCK 1514 lb
PTE-#8 SPC POINT EAST #8 ROCK 200 lb
PTE-SND SPC POINT EAST SAND 1475 lb
AG-II/V ASHGROVE AG TYPE-II/V CEMENT 370 lb
NAVAJO HEADWATERS FLYASH 100 lb
WATER Water POTABLE WATER 31 gal
P-200N BASF TYPE A WATER REDUCER 3.0 /cwt
Total 3918 lb
Tolerance
Air Content
Slump Designed W/ C Ratio3 - 5
lb/ ft3
4.00 0.55
Entrapped 145.1Designed Unit Weight2
Admixture dosages may vary depending on enviormental conditions
Prepared By :
Jeremy Wilcox
ACI STATISTICAL REPORT
Period : 01/14/2016 to 05/25/2016
Mix : 3000 NA
3000 Specified Strength
Average Strength
Standard Deviation
Corrected CofV ACI Running Average of 3 Criteria
ACI Standard Deviation Criteria
5000
570
11.4 Yes
Yes
28 Day
Required Strength 3830
Compressive Test Number of Tests 30
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
Count
Average
STDEV
COV%
Range Min
Range Max
30 30 30 30 30 28
1.67 69 4.38 3070 5000 5000
0.42 7 0.74 360 570 380
25.4 9.8 16.9 11.8 11.5 7.6
1.10 59 3.00 2350 3610 4210
3.00 89 5.50 3750 5990 5740
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
05/25/2016 95216
03/02/2016529276
529272
02/26/2016528430
528426
02/23/2016 528144
02/12/2016
526909
526905
527013
02/09/2016 526317
02/04/2016
526033
526029
526025
01/28/2016525063
525059
01/25/2016 524640
01/22/2016 524369
01/21/2016
524278
15116
524282
524286
01/19/2016 524025
01/14/2016
523770
523766
523754
523750
523746
523742
523738
9016
Date Sam ple
3.00 68 4.50 2560 4700 5310
1.70 62 3.50 3620 5600 5740
1.50 65 5.00 3530 5630 5400
1.20 71 4.25 3140 5990 5520
1.30 71 3.00 2980 4590 5240
1.40 68 3.50 3410 5990 5240
1.30 89 4.00 2970 5150 5060
1.10 82 3.00 2490 4590 5090
1.80 64 4.50 3050 5430 5230
1.20 77 3.50 3170 5260 5050
1.20 74 4.50 3200 5010 4780
1.30 74 4.50 2980 4880 4820
1.50 72 4.50 2720 4440 4620
1.50 73 4.50 3150 5150 4650
1.20 72 5.00 3270 4260 4810
1.50 72 4.50 2520 4530 4940
1.60 71 3.50 3700 5650 5030
1.80 68 5.50 2730 4630 4630
1.50 68 4.00 3040 4820 4810
1.80 67 5.50 2740 4430 5130
2.00 64 5.50 3080 5180 5520
1.30 70 5.00 3750 5770 5600
2.00 64 3.00 3450 5600 5140
2.20 62 5.00 3420 5430 5040
2.10 60 5.00 3270 4390 4430
2.00 62 5.00 3190 5290 4420
1.90 59 5.00 2350 3610 4210
2.00 60 4.75 2810 4350 4650
2.10 60 4.50 2780 4670
2.20 69 4.00 3150 4940
Date : 14/25/2017 Page 1 of
DATE: 04/25/2017Concrete Mix Design Submittal
No. JW-042517-02 Version 1
PROJECT NAME: Olympus Gymnastic Training Ceter
MIX NUMBER 3325107S
3000 NA Super
PLANT
Mix Description
Footings, Grade Beams, Interior SlabsINTENDED USE:
3000 psiDesign Strength
623ASTM C-94 Options A & C
CUSTOMER: TACTIC CONSTRUCTION
Material Code
Material Supplier
DesignQuantity
Material Description
PTE-#57 SPC POINT EAST #57 ROCK 1660 lb
PTE-SND SPC POINT EAST SAND 1475 lb
AG-II/V ASHGROVE AG TYPE-II/V CEMENT 370 lb
NAVAJO HEADWATERS FLYASH 100 lb
WATER Water POTABLE WATER 31.5 gal
P-200N BASF TYPE A WATER REDUCER 1.0 /cwt
GLEN3030 BASF TYPE F WATER REDUCER 6.0 /cwt
Total 3868 lb
Tolerance
Air Content
Slump Designed W/ C Ratio5 - 8
lb/ ft3
6.00 0.56
Entrapped 143.2Designed Unit Weight2
Admixture dosages may vary depending on enviormental conditions
Prepared By :
Jeremy Wilcox
ACI STATISTICAL REPORT
Period : 05/27/2015 to 01/16/2017
Mix : 3000 NA
3000 Specified Strength
Average Strength
Standard Deviation
Corrected CofV ACI Running Average of 3 Criteria
ACI Standard Deviation Criteria
5440
460
8.5 Yes
Yes
28 Day
Required Strength 3620
Compressive Test Number of Tests 19
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
Count
Average
STDEV
COV%
Range Min
Range Max
19 19 19 19 19 17
1.94 70 5.34 3420 5440 5470
0.56 10 0.47 490 420 290
28.7 13.6 8.9 14.5 7.8 5.3
1.00 56 5.00 2550 4490 4840
3.00 90 6.50 4190 6000 5910
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
01/16/2017 7817
11/21/2016 584060
11/14/2016 582923
11/07/2016 581815
09/13/2016 148116
08/04/2016 126116
07/25/2016 556235
07/22/2016 556251
03/28/201662616
62516
02/26/2016 45316
12/10/2015 277015
11/19/2015 256515
11/10/2015 246815
09/21/2015 196615
09/03/2015 179915
07/27/2015 146615
05/27/201599115
99015
Date Sam ple
1.00 70 5.50 3530 5400 5430
1.40 62 5.50 2950 4890 5550
1.90 69 6.50 4190 6000 5790
1.70 78 5.00 3840 5760 5700
2.30 74 5.00 4050 5620 5280
2.40 80 5.00 3980 5730 5100
1.50 90 5.00 2640 4490 4840
1.80 79 6.00 2860 5070 5130
2.40 56 5.00 2880 4960 5290
2.20 60 5.00 2940 5370 5610
1.90 70 5.00 3360 5530 5750
3.00 57 6.00 3650 5930 5910
1.80 60 5.50 3530 5800 5680
1.30 56 6.00 3920 6000 5720
1.80 72 5.00 3300 5230 5440
3.00 76 5.00 3790 5920 5480
2.50 80 5.50 2550 5170 5230
1.40 72 5.00 3480 5350
1.50 70 5.00 3560 5160
Date : 14/25/2017 Page 1 of
DATE: 04/25/2017Concrete Mix Design Submittal
No. JW-042517-02 Version 1
PROJECT NAME: Olympus Gymnastic Training Ceter
MIX NUMBER 3326104S
4500 AE Super
PLANT
Mix Description
Exposed Footings, Grade Beams, Wallls, Sit e Work INTENDED USE:
4500 psiDesign Strength
623ASTM C-94 Options A & C
CUSTOMER: TACTIC CONSTRUCTION
Material Code
Material Supplier
DesignQuantity
Material Description
PTE-#57 SPC POINT EAST #57 ROCK 1690 lb
PTE-SND SPC POINT EAST SAND 1255 lb
AG-II/V ASHGROVE AG TYPE-II/V CEMENT 519 lb
NAVAJO HEADWATERS FLYASH 92 lb
WATER Water POTABLE WATER 31 gal
MICRO-AE BASF AIR ENTRAINMENT 1 lq oz
P-200N BASF TYPE A WATER REDUCER 1.5 /cwt
GLEN3030 BASF TYPE F WATER REDUCER 6.0 /cwt
Total 3815 lb
Tolerance
Air Content
Slump Designed W/ C Ratio5 - 8
lb/ ft3
6.00 0.42
4.5 - 7.5 141.3Designed Unit Weight6
Admixture dosages may vary depending on enviormental conditions
Prepared By :
Jeremy Wilcox
ACI STATISTICAL REPORT
Period : 11/17/2015 to 03/16/2017
Mix : 4500 AE
4500 Specified Strength
Average Strength
Standard Deviation
Corrected CofV ACI Running Average of 3 Criteria
ACI Standard Deviation Criteria
5970
660
11.1 Yes
Yes
28 Day
Required Strength 5540
Compressive Test Number of Tests 30
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
Count
Average
STDEV
COV%
Range Min
Range Max
30 30 30 30 30 28
6.32 71 5.18 4190 5970 5970
0.70 5 0.46 670 660 420
11.1 7.6 8.9 16.1 11.1 7.1
5.00 61 5.00 3020 4560 5110
7.40 80 6.50 5250 7000 6770
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
03/16/2017 56317
03/14/2017 53717
03/09/2017 49217
03/01/201741317
41217
02/20/2017 33317
02/15/2017 29917
02/02/2017 21917
12/05/2016 192416
11/02/2016 178616
09/15/2016 150116
09/06/2016 144516
09/14/2016 569960
09/02/2016 567534
08/09/2016 130216
08/08/2016 127616
07/01/2016 551230
06/20/2016 109316
06/07/2016 100716
05/24/2016 93216
05/18/2016 90316
05/17/2016 89616
05/04/2016 539913
04/19/2016 75916
03/31/2016 64816
02/23/2016 40916
01/05/2016 616
12/15/2015 279915
12/10/2015 277315
11/17/2015 253615
Date Sam ple
7.00 70 5.50 3900 5460 5800
6.50 63 5.00 3890 5720 5970
5.90 72 5.00 4580 6210 6020
6.10 63 5.00 4240 5980 6280
6.20 63 5.00 4530 5860 6510
5.00 78 5.00 5030 7000 6770
5.80 70 5.00 4550 6660 6550
5.80 65 5.00 5250 6640 6490
6.00 65 5.00 4500 6350 6150
7.10 74 5.00 4620 6470 5920
6.80 77 5.00 3910 5640 5520
6.40 74 5.00 3320 5640 5290
6.20 70 5.00 3420 5280 5570
6.60 80 6.50 3050 4960 5960
6.40 79 5.00 4770 6480 5900
5.50 80 5.00 4530 6440 6070
5.50 75 5.00 3020 4790 5680
5.60 74 5.00 5090 6980 5920
7.40 80 5.00 3650 5270 5730
6.40 68 5.00 3670 5510 5890
7.00 68 5.00 4190 6400 5570
7.00 73 5.00 5150 5750 5110
7.40 74 6.50 3150 4560 5150
6.80 61 5.00 3810 5030 5830
7.20 70 5.00 3400 5870 6410
5.50 75 5.00 4850 6600 6430
5.00 72 5.50 4950 6770 6330
7.10 70 5.00 3840 5920 6240
5.50 69 5.00 3870 6300
7.00 69 6.50 4960 6490
Date : 14/25/2017 Page 1 of
DATE: 04/25/2017Concrete Mix Design Submittal
No. JW-042517-02 Version 1
PROJECT NAME: Olympus Gymnastic Training Ceter
MIX NUMBER 3326880
5000 AE
PLANT
Mix Description
Site WorkINTENDED USE:
5000 psiDesign Strength
623ASTM C-94 Options A & C
CUSTOMER: TACTIC CONSTRUCTION
Material Code
Material Supplier
DesignQuantity
Material Description
PTE-#57 SPC POINT EAST #57 ROCK 1680 lb
PTE-SND SPC POINT EAST SAND 1151 lb
AG-II/V ASHGROVE AG TYPE-II/V CEMENT 559 lb
NAVAJO HEADWATERS FLYASH 99 lb
RHEOSF10 BASF SILICA FUME 25 lb
WATER Water POTABLE WATER 33 gal
MICRO-AE BASF AIR ENTRAINMENT 3 lq oz
POLY-997 BASF TYPE F WATER REDUCER 4.0 /cwt
GLEN3030 BASF TYPE F WATER REDUCER 4.0 /cwt
Total 3789 lb
Tolerance
Air Content
Slump Designed W/ C Ratio4 - 6
lb/ ft3
5.00 0.40
4.5 - 7.5 140.4Designed Unit Weight6
Admixture dosages may vary depending on enviormental conditions
Prepared By :
Jeremy Wilcox
ACI STATISTICAL REPORT
Period : 06/16/2015 to 02/13/2017
Mix : 5000 A E Titan
5000 Specified Strength
Average Strength
Standard Deviation
Corrected CofV ACI Running Average of 3 Criteria
ACI Standard Deviation Criteria
7110
610
8.6 Yes
Yes
28 Day
Required Strength 5920
Compressive Test Number of Tests 30
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
Count
Average
STDEV
COV%
Range Min
Range Max
30 30 30 30 30 28
5.98 72 5.24 4660 7110 7090
0.79 6 0.81 510 610 430
13.1 9.0 15.5 10.9 8.6 6.1
4.80 56 4.00 3620 5280 6090
7.50 86 6.50 5790 7950 7640
Air Content
%
Concrete
Tempdeg F
Slump
in
7 Str
psi
Strength28
psi
Str 28 Run
Avg 3psi
02/13/2017 28917
12/12/2016 194416
10/05/2016 162816
09/21/2016 153116
08/31/2016 142116
08/11/2016 131716
07/25/2016 556243
07/20/2016 117916
05/31/2016 98216
05/25/2016 94916
05/18/2016 91116
05/16/2016 89116
04/11/2016 69116
03/24/2016 60316
03/08/2016 54416
02/03/2016 525698
02/02/2016525557
24416
11/13/2015516197
516144
11/12/2015 515289
10/28/2015 231015
10/22/2015 510736
10/21/2015 224415
10/09/2015 214515
09/29/2015 204715
09/28/2015 202715
09/22/2015 198315
08/11/2015 156615
06/16/2015 117115
Date Sam ple
7.50 70 6.00 5330 7440 7410
6.40 74 4.50 5790 7370 7070
6.20 69 6.00 4090 7430 7090
6.00 72 6.00 4660 6420 6790
5.40 78 6.50 5260 7430 6410
5.90 83 6.50 4080 6530 6230
7.00 86 6.00 3620 5280 6090
5.50 82 6.00 4830 6890 6840
5.10 78 5.00 3980 6090 6720
6.00 68 5.00 4780 7550 6960
7.20 70 5.00 4200 6510 6500
6.60 72 4.50 4540 6810 6760
7.50 56 6.50 3780 6190 6900
5.10 72 5.50 4740 7270 7490
6.60 72 6.00 4460 7250 7170
5.20 63 4.00 5310 7950 7260
5.90 69 4.75 4080 6310 6990
6.00 66 4.50 4620 7520 7410
5.00 70 4.50 4710 7130 7460
5.80 70 4.00 4810 7580 7620
5.10 64 4.50 4950 7680 7610
7.20 70 4.50 5030 7600 7600
5.50 65 5.00 4520 7540 7640
6.20 70 4.50 5350 7670 7620
5.50 72 6.50 4510 7720 7280
5.00 80 5.00 4780 7480 7120
6.80 78 5.50 4140 6630 7060
4.80 76 4.00 4720 7260 7300
5.50 78 5.50 5050 7280
5.90 78 5.50 4960 7370
Date : 14/25/2017 Page 1 of
Beck Street PH 801 258-3952 www.stakerparson.com
Beck Street Office PO Box 27598, Salt Lake City, UT 84127
1730 North Beck Street, Salt Lake City, UT 84116
ROCK PRODUCTS, READY MIX CONCRETE, ASPHALT, PAVING, & CONSTRUCTION
February 14, 2017 Jack B Parson Companies Attn: Jeremy Wilcox Email: jeremy.wilcox@stakerparson.com Phone: (435) 994-6092 Fax: (801) Re: 2017 C-33 Tests
Concrete Sand
Jeremy Wilcox: Staker & Parson Companies is pleased to submit for your review and approval the following Job Mix Gradation for the above-mentioned project.
Material Source: Point East Pit (001050) located at 15589 So. 500 West; Draper, UT
Material Type: Concrete Sand
Sieve Target Specification ASTM C-33
ASTM C-33 Results
100% 100 Sodium Sulfate Soundness C-88 1.00% Loss
# 4 99% 95-100 Organic Impurities C-40 Plate #1
# 8 89% 80-100 Clay Lumps & Friable C-142 0.0%
# 16 59% 50-85 Light Weight Pieces C-123 0%
# 30 38% 25-60 Bulk, Oven Dry C-127/128 2.493
# 50 24% 5-30 Bulk, SSD C-127/128 2.533
# 100 9% 0-10 Apparent C-127/128 2.596
# 200 2.2% 0-3 Absorption C-127/128 1.58%
F.M. 2.82 Dry Rodded Unit Weight C-29 105 lbs/ft3
This is a typical gradation, generated from daily quality control samples. Individual gradations were ran in accordance with AASHTO T-27 or ASTM C-136. Tests ran in accordance with ASTM C-33. If you have any questions concerning this letter, please contact me at Cell (801) 514-5132.
Sincerely Staker & Parson Companies
David Evans Quality Control Engineer
Beck Street PH 801 258-3952 www.stakerparson.com
Beck Street Office PO Box 27598, Salt Lake City, UT 84127
1730 North Beck Street, Salt Lake City, UT 84116
ROCK PRODUCTS, READY MIX CONCRETE, ASPHALT, PAVING, & CONSTRUCTION
February 14, 2017 Jack B Parson Companies Attn: Jeremy Wilcox Email: jeremy.wilcox@stakerparson.com Phone: (435) 994-6092 Fax: (801) Re: 2017 C-33 Tests
Pt. East Pea Gravel Jeremy Wilcox: Staker & Parson Companies is pleased to submit for your review and approval the following Job Mix Gradation for the above-mentioned project.
Material Source: Pt. East Pit (001050) located at 15589 So. 500 West; Draper, UT
Material Type: Pt. East Pea Gravel ( ASTM #8 Stone )
Sieve Target Specification ASTM C-33, #8
ASTM C-33 Results
100% 100 Spec. Gravity, Bulk C-127/128 2.449
92% 85-100 Spec. Gravity, SSD C-127/128 2.498
24% Spec. Gravity, Apparent C-127/128 2.575
# 4 10% 10-30 Absorption C-127/128 1.99%
# 8 2% 0-10 La Wear C-131 22.9%
# 16 1% 0-5 Soundness C-88 0.71%
# 30 1% Clay Lumps & Friables C-142 0.08%
# 50 1% Light Weight Pieces C-123 0%
# 200 0.6% 0-1 Dry Rodded Unit Wt. C-29 94 lbs/ft3
This is an average of recent quality control samples, for the above-mentioned project. The material meets ASTM C-33 Standard. If you have any questions concerning this letter, please contact me Cell (801) 514-5132.
Sincerely Staker & Parson Companies
David L. Evans Quality Control Engineer
Beck Street PH 801 258-3952 www.stakerparson.com
Beck Street Office PO Box 27598, Salt Lake City, UT 84127
1730 North Beck Street, Salt Lake City, UT 84116
ROCK PRODUCTS, READY MIX CONCRETE, ASPHALT, PAVING, & CONSTRUCTION
February 14, 2017 Jack B Parson Companies Attn: Jeremy Wilcox Email: jeremy.wilcox@stakerparson.com Phone: (435) 994-6092 Fax: (801) Re: 2017 C-33 Tests Pt. East Concrete Rock Jeremy Wilcox: Staker & Parson Companies is pleased to submit for your review and approval the following Job Mix Gradation for the above-mentioned project.
Material Source: Pt. East Pit (001050) located at 15589 So. 500 West; Draper, Utah
Material Type: Pt. East Concrete Rock
Sieve Target Results
100% 95-100 Bulk, Oven Dry 2.459
¾ 93% Bulk, SSD 2.501
½ 43% 25-60 Apparent 2.567
15% absorption 1.72%
# 4 2% 0-10 LA Wear 24.2%
# 8 1% Clay Lumps & Friables 0.08%
# 16 1% Sodium Sulfate Soundness 0.51%
# 50 1% Light Wt. Pieces 0.0%
# 200 0.5% 0-1 Dry Rodded Unit Wt. 93 lbs/ft3
This is an average of recent quality control samples, for the above-mentioned project. If you have any questions concerning this letter, please contact me Cell (801) 514-5132.
Sincerely Staker & Parson Companies
David Evans Quality Control Engineer
Materials Testing & Research Facility
2650 Old State Hwy 113
Taylorsville, GA 30178
770-684-0102
MTRF ID: 191NV
ASTM C618 / AASHTO M295 Testing of
Sample Type: 3200-ton
Sample Date: 1/13 - 1/17/17 Report Date: 2/28/2017
Sample ID: NV-005-17
ASTM LimitClass F/C Class F/C
Silicon Dioxide (SiO2) 59.38
Aluminum Oxide (Al2O3) 23.80
Iron Oxide (Fe2O3) 4.34
Sum (SiO2+Al2O3+Fe2O3) 87.52
Sulfur Trioxide (SO3) 0.41
Calcium Oxide (CaO) 5.32
Moisture 0.13
Loss on Ignition 0.68
Physical Analysis
Fineness, % retained on 45-µm sieve 21.16
70.0/50.0 min 70.0/50.0 min
5.0 max 5.0 max
6.0 max 5.0 max
3.0 max 3.0 max
34 max 34 max
%
%
%
%
%
%
%
%
%
Headwaters Resources certifies that pursuant to current ASTM C618 protocol for testing, the test data listed herein was generated by applicable ASTM methods and meets the requirements of ASTM C618.
AASHTO R 18
SM
Magnesium Oxide (MgO) 1.22 %
Sodium Oxide (Na2O) 2.12 %
Potassium Oxide (K2O) 1.33 %
Chemical Analysis ResultsAASHTO Limit
Strength Activity Index - 7 or 28 day requirement
7 day, % of control 78
28 day, % of control 85
Water Requirement, % control 98
Autoclave Soundness 0.02
Density 2.29
75 min 75 min
75 min 75 min
105 max 105 max
0.8 max 0.8 max
%
%
%
%
Navajo Generating Station Fly Ash
Available Alkalies, as Na2Oe 1.40 Not Required 1.5 max*%*when required by purchaser
DESCRIPTIONCure & Seal 309 J18 is a water based acrylic copolymerthat offers a combination curing, sealing anddustproofing for freshly finished concrete surfaces. Thisproduct dries to produce a non-yellowing, durable, clearfilm on concrete. Cure & Seal 309 J18 is ideal forinterior applications because it is free of noxiousflammable fumes.
USECure & Seal 309 J18 is a convenient, safe-to-use productthat meets the ASTM C-309 standard as an effectivemembrane curing compound and is an excellentdustproofer and surface sealer. It is designed forinterior and exterior use.
FEATURES■ Water-based■ Meets ASTM C-309■ Excellent sealer and dustproofer■ Low odor■ Non-flammable■ Easy clean-up with water■ Interior/exterior applications■ U.V. Stable, resists yellowing
PROPERTIESMeets ASTM C-309, Type 1, Classes A & B,AASHTO M-148, Type 1, Classes A & B
Drying time:Approximately 2-3 hrs. at 70°F (21°C) for recoating orlight traffic. Wait 12 hrs. for heavy traffic. Dry time istemperature, wind and humidity dependent.
VOCLess than 200 g/l. Complies with Canadian and U.S.Federal EPA ,OTC, CARB & LADCO Standards forConcrete Curing Compounds
Estimating GuideCuring:1st coat 200 Ft²/Gallon 4.9 M²/Liter2nd coat 400 – 600 Ft²/Gallon 9.8 – 14.8 M²/LiterTexture and absorption rate of the concrete willinfluence coverage rate.
Packaging
PRODUCTCODE PACKAGE
SIZE
Gallons Liters
69223 Pail 5 18.93
69221 Drum 55 208.20
STORAGEThe Cure & Seal 309 J18 should be stored in tightly sealedoriginal factory containers. Store in a horizontal positionto prevent moisture accumulation on the drum head. Donot allow to freeze. Shelf life of properly stored, unopenedcontainers is 18 months
Mixing:Agitate Cure & Seal 309 J18 before each use.
Placement:Apply Cure & Seal 309 J18 immediately after all surfacewater has disappeared and the surface cannot be marred.Application of Cure & Seal 309 J18 too early or too latecan affect the overall curing performance. Use lowpressure spray, roller or brush. Do not thin. Applyuniformly without puddles. For improved applicationconsistency and reduction in labor, use the Dayton Spray-Pro (Item # 309233 or 309232) power spray system.Application of a second coat, after the first coat has dried,will provide a longer lasting, higher gloss coating withimproved water retention performance.
CLEAN UPTools and equipment can be cleaned with warm, soapywater before the product dries. For removal of driedproduct, use Dayton Superior Green Bean Clean®.
LIMITATIONS
FOR PROFESSIONAL USE ONLYThis product should not be used at temperatures below40°F (4°C). Do not apply concrete or mortar toppings oversealed surfaces. Avoid spraying Cure & Seal 309 J18 intojoint prior to installation of sealant. May show rubber tiremarks. Do not use high speed mixing equipment. RemoveCure & Seal 309 J18 with Citrus Cleaner J48 or Green BeanClean® before applying resinous (epoxy, polyester,urethanes, etc.) coatings. Do not store food containersdirectly on the floor, always place on pallets. Whenmoisture-sensitive flooring is to be applied to the concretetreated with this product first refer to ACI 302.2R
PRECAUTIONS
READ SDS PRIOR TO USING PRODUCT■ Use with adequate ventilation■ Wear protective clothing, gloves and eye protection
(goggles, safety glasses and/or face shield)■ Keep out of the reach of children■ Do not take internally■ In case of ingestion, seek medical help immediately■ May cause skin irritation upon contact, especially
prolonged or repeated. If skin contact occurs, washimmediately with soap and water and seek medicalhelp as needed.
■ If eye contact occurs, flush immediately with cleanwater and seek medical help as needed
Cur
es &
Sea
ls
Sec4
Cure & Seal 309 J18Water-Based Cure & Seal
TECHNICAL DATA SHEET
Visit www.daytonsuperior.com for the most up to date technical information
Page 1 of 2 File Date: 11/26/2014
■ Dispose of waste material in accordance withfederal, state and local requirements
MANUFACTURERDayton Superior Corporation1125 Byers RoadMiamisburg, OH 45342Customer Service: 888-977-9600Technical Services: 877-266-7732Website: www.daytonsuperior.com
WARRANTYDayton Superior Corporation ("Dayton") warrants for 12 monthsfrom the date of manufacture or for the duration of the publishedproduct shelf life, whichever is less, that at the time of shipmentby Dayton, the product is free of manufacturing defects andconforms to Dayton’s product properties in force on the date ofacceptance by Dayton of the order. Dayton shall only be liableunder this warranty if the product has been applied, used, andstored in accordance with Dayton’s instructions, especially surfacepreparation and installation, in force on the date of acceptance byDayton of the order. The purchaser must examine the productwhen received and promptly notify Dayton in writing of any non-conformity before the product is used and no later than 30 daysafter such non-conformity is first discovered. If Dayton, in its solediscretion, determines that the product breached the abovewarranty, it will, in its sole discretion, replace the non-conformingproduct, refund the purchase price or issue a credit in the amountof the purchase price. This is the sole and exclusive remedy forbreach of this warranty. Only a Dayton officer is authorized tomodify this warranty. The information in this data sheetsupersedes all other sales information received by the customerduring the sales process. THE FOREGOING WARRANTY SHALL BEEXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS ORIMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY ANDFITNESS FOR A PARTICULAR PURPOSE, AND ALL OTHERWARRANTIES OTHERWISE ARISING BY OPERATION OF LAW,COURSE OF DEALING, CUSTOM, TRADE OR OTHERWISE.
Dayton shall not be liable in contract or in tort (including,without limitation, negligence, strict liability or otherwise) forloss of sales, revenues or profits; cost of capital or funds;business interruption or cost of downtime, loss of use, damageto or loss of use of other property (real or personal); failure torealize expected savings; frustration of economic or businessexpectations; claims by third parties (other than for bodilyinjury), or economic losses of any kind; or for any special,incidental, indirect, consequential, punitive or exemplarydamages arising in any way out of the performance of, orfailure to perform, its obligations under any contract for saleof product, even if Dayton could foresee or has been advisedof the possibility of such damages. The Parties expressly agreethat these limitations on damages are allocations of riskconstituting, in part, the consideration for this contract, andalso that such limitations shall survive the determination ofany court of competent jurisdiction that any remedy providedin these terms or available at law fails of its essential purpose.
Cures &
Seals
Sec4
Cure & Seal 309 J18Water-Based Cure & Seal
TECHNICAL DATA SHEET
Visit www.daytonsuperior.com for the most up to date technical information
Page 2 of 2 File Date: 11/26/2014
DESCRIPTION EVAPRE evaporation retardant is an economical, high quality, water-based compound. It is specifically designed to form a thin monomolecular film to reduce rapid moisture loss from the concrete surfaces prior to curing. EVAPRE provides a significant aid in producing high-quality concrete flatwork. Rapid evaporation of water is retarded, slab surface conditions are normalized, and workers can adhere more closely to established finishing schedules. EVAPRE is also VOC-compliant. EVAPRE significantly reduces plastic shrinkage and cracking, wind crusting, stickiness, and sponginess, which often cause poor and uneven surface texture. These conditions result when the hydration is more rapid than the movement of bleed water to the surface. EVAPRE effectively combats and minimizes the effects of rapid-drying conditions such as low humidity, low dew point, high winds, direct sunlight, hot weather, heated concrete, or placement of concrete in a heated enclosure or interior area during cold weather. The protective film shield disappears as soon as the concrete is no longer plastic.
USES EVAPRE is ideal for use as an evaporation retardant for concrete surfaces where the evaporation rate exceeds the rate of bleeding. EVAPRE can be used with the MEADOW-PATCH® and MEADOW-CRETE® line of repair mortars from W. R. MEADOWS. It can also be used with condensed silica fume concrete, concrete containing fly ash, and most other cementitous products. When applying surface hardeners, EVAPRE can be used after screeding and after the first floating operation, if necessary.
NOTE: EVAPRE is specifically designed to fight off the destructive effects of early rapid evaporative moisture loss. Early rapid evaporative moisture loss is addressed in ACI Committee 305R-91, entitled "Recommended Practice for Hot Weather Concreting." This report contains a chart on page five that depicts the effect of concrete and air temperatures, relative humidity, and wind velocity on the rate of evaporation of surface moisture from concrete. It provides a graphic method for estimating the loss of surface moisture for various weather conditions.
FEATURES/BENEFITS • Significantly reduces plastic shrinkage and
cracking caused by evaporation in low humidity, high temperatures, and high winds.
• Allows use of lower slump and lower water: cement ratio concrete.
• Provides smooth and durable concrete flatwork.
• Reduces wind crusting, stickiness, and sponginess, which often cause poor and uneven surface texture.
• Allows finishing crews to adhere to established schedules.
• Reduces overall cost because timing of finishing operations is less critical.
• VOC-compliant. • Helps minimize surface cracking due to early
water loss of silica fume concrete. • Available in exclusive, easy-to-use, 45-ounce
containers.
PACKAGING 45 Ounce (1,596.9 cm3) Containers 1 Gallon (3.8 Liter) Units 5 Gallon (18.93Liter) Pails 55 Gallon (208.2 Liters) Drums
COVERAGE One gallon (3.8 liter) of EVAPRE mixed with nine gallons (34.2 L) of water will cover 2000 - 4000 ft.2 (50 - 100 m2/L). Quantity needed increases if additional coats are required. Forty-five ounce (1596.9 cm3) container - pour into a 3.5 gallon sprayer, add water, and it is ready to use. SHELF LIFE When stored indoors and in original, unopened containers at temperatures between 40 - 90° F (4 - 32° C), shelf life is a minimum of one year from date of manufacture.
EVAPRE TM Evaporation Retardant
MasterFormat: 03 00 00
NO. 356-A APRIL 2013 (Supersedes July 2004)
CONTINUED ON REVERSE
W. R. MEADOWS, INC.
www.wrmeadows.com
HAMPSHIRE, IL / CARTERSVILLE, GA / YORK, PAFORT WORTH, TX / BENICIA, CA / POMONA, CAGOODYEAR, AZ / MILTON, ON / ST. ALBERT, AB
P.O. Box 338 • HAMPSHIRE, IL 60140-0338Phone: 847/214-2100 • Fax: 847/683-4544
1-800-342-5976
SPECIFICATIONS � Complies with all current federal, state, and local
maximum allowable VOC requirements, including U.S. EPA, SCAQMD, and OTC.
APPLICATION STEP 1 - For the majority of applications, EVAPRE should be mixed at a ratio of one (1) part EVAPRE to nine (9) parts water. Agitate EVAPRE before mixing with water. Agitate the diluted solution again, before applying. NOTE: EVAPRE is available in an easy-to-use, exclusive 45-ounce container. Just pour into a 3.5 gallon sprayer, add water to fill, and go to work. STEP 2 - Apply EVAPRE with a commercial sprayer, such as a Chapin 1949. Use a Chapin 6-5797 or equivalent spray nozzle that produces a flow rate of .5 gallon per minute. STEP 3 - The EVAPRE diluted solution should be applied immediately after screeding and/or between finishing operations, as needed. Application is simplified by the fugitive pigment, which will disappear completely upon drying. Do not allow puddling. If puddling occurs, wipe up immediately and rinse with water. STEP 4 - Clean all equipment immediately after use with soap and water. STEP 5 - Finish concrete surface as required. STEP 6 - Cure concrete after bleed water or excess surface water has dissipated. The use of EVAPRE does not negate the need for a quality concrete curing or curing and sealing compound from W. R. MEADOWS. NOTE … The residue remaining on the surface after finishing will not impair bonding or alter color. The protective shield usually lasts as long as the concrete is plastic. Therefore, all concrete surfaces must be properly cured as well.
PRECAUTIONS Keep from freezing. EVAPRE should not be over-applied or worked excessively into the concrete surface during finishing operations. EVAPRE should not be used to re-temper the concrete. EVAPRE is not a curing agent.
W. R. MEADOWS is not responsible for compatibility or results when EVAPRE is used with other manufacturer's products.
Read and follow application information and use in accordance with the health and Safety information shown on the container label. Refer to Material Safety Data Sheet for complete health and safety information. LEED INFORMATION May help contribute to LEED credits: � IEQ Credit 4.2: Low-Emitting Materials:
Paints & Coatings � IEQ Credit 4.3: Low-Emitting Materials:
Flooring � MR Credit 2: Construction Waste
Management � MR Credit 5: Regional Materials
For most recent data sheet, further LEED information, and MSDS, visit www.wrmeadows.com.
PAGE 2 … EVAPRE #356-A … APRIL 2013
© W. R. MEADOWS 2002 04/13-4M
LIMITED WARRANTY“W. R. MEADOWS, INC. warrants at the time and place we make shipment, our material will beof good quality and will conform with our published specifications in force on the date ofacceptance of the order.” Read complete warranty. Copy furnished upon request.
DisclaimerThe information contained herein is included for illustrative purposes only, and to the best of ourknowledge, is accurate and reliable. W. R. MEADOWS, INC. cannot however under anycircumstances make any guarantee of results or assume any obligation or liability in connection
with the use of this information. As W. R. MEADOWS, INC. has no control over the use to which others may put itsproduct, it is recommended that the products be tested to determine if suitable for specific application and/or ourinformation is valid in a particular circumstance. Responsibility remains with the architect or engineer, contractor andowner for the design, application and proper installation of each product. Specifier and user shall determine thesuitability of products for specific application and assume all responsibilities in connection therewith.
DESCRIPTIONClean Strip Ultra J3 is a premium, low odor, ready-to-use, chemically reactive form release that is V.O.C.compliant in most all regulatory regions. It is ideal forarchitectural and precast concrete and for generalforming applications. Clean Strip Ultra J3 works toensure clean, positive release of plywood, fiberglass,aluminum, steel and other concrete forming materials.Clean Strip Ultra J3 prolongs the life of plywood forms,and acts to reduce rusting of steel forms. Properlyapplied, Clean Strip Ultra J3 is non-staining, reduces thenumber of surface air voids (bugholes) and will notinterfere with the adhesion of subsequent coatings.
USEClean Strip Ultra J3 chemically releases hardenedconcrete from steel, aluminum, plywood, andcomposition forms. In conjunction with good concreteplacement and forming technique, this quality productpromotes easy stripping and minimizes form clean up. Itis non-staining, and reduces the number of surface airvoids (bugholes) on regular and superplasticizedconcrete.
FEATURES■ Coverage up to 2,000 sq. ft./gal.■ Extended form life■ Reduced labor normally used to clean forms■ Minimizes concrete surface dusting■ Helps prevent rusting of steel forms■ Compatible with most form liners■ Low odor Clean Strip™ Ultra J3 is suitable for use on
all forms except expanded polystyrene.
VOCLess than 250 g/L. Compliant with most Canadian andU.S. VOC regulations for Concrete Form Release agentsincluding Federal EPA, OTC, LADCO & CARB.
Estimating GuideSq. Feet per
gallonsSq. Meters per
Liters
Steel 2500 61.5
Aluminum 2500 31.5
Medium DensityPlywood 1500-2000 36.9-49.2
High Density Plywood 2500 61.5
Rough Sawn Lumber1st coat 1000 24.6
2nd coat 1500 36.9
Texture and absorption of forming material will dictate final coverage rate.Prior to coating plywood forms, apply one or two heavy brush coats to
edges to ensure ease of form removal.
Packaging
PRODUCTCODE PACKAGE
SIZE
Gallons Liters
309133 Pail 5 18.93
309134 Drum 55 208.20
309135 Tote 275 1040.99
STORAGEStore in dry environment.Shelf life is two years from date of manufacture.
APPLICATION
Surface Preparation:Surfaces to be treated should be clean and free of water,dust and dirt or residues that might transfer to the finalconcrete surface.
Placement:Apply during dry weather with low pressure spray, roller orbrush. Apply uniformly in a thin but continuous film toassure proper coverage. For best results apply to formsbefore each use. Avoid applying too heavily. Wipeexcessive material from forms prior to installing forms andconcrete placement. Prior to coating plywood forms, applyone or two heavy brush coats to edges to ensure completewater-proofing protection.
CLEAN UPSprayers and other equipment may be cleaned with CitrusCleaner J48 or other solvent degreaser.
LIMITATIONS
FOR PROFESSIONAL USE ONLYNot for use as a bond breaker or concrete release agent fortiltup concrete construction. Requires recoating after eachuse. Do not apply onto reinforcing steel. DO NOT OVERAPPLY. Over-application could cause excessive surfacedusting and/or transfer to concrete. When any material isto be applied over the newly formed concrete, follow theapplication instructions of the material,manufacturer.
PRECAUTIONS
READ SDS PRIOR TO USING PRODUCT■ Keep material and containers away from high heat,
open flames, sparks or other sources of ignition■ Use with adequate ventilation■ Wear protective clothing, gloves and eye protection
(goggles, safety glasses and/or face shield)■ Keep out of the reach of children■ Do not take internally■ In case of ingestion, seek medical help immediately
Form
Rel
ease
Age
nts
Sec7
Clean Strip™ Ultra J3Form Release
TECHNICAL DATA SHEET
Visit www.daytonsuperior.com for the most up to date technical information
Page 1 of 2 File Date: 12/30/2014
■ May cause skin irritation upon contact, especiallyprolonged or repeated. If skin contact occurs, washimmediately with soap and water and seek medicalhelp as needed.
■ If eye contact occurs, flush immediately with cleanwater and seek medical help as needed
■ Dispose of waste material in accordance withfederal, state and local requirements
MANUFACTURERDayton Superior Corporation1125 Byers RoadMiamisburg, OH 45342Customer Service: 888-977-9600Technical Services: 877-266-7732Website: www.daytonsuperior.com
WARRANTYDayton Superior Corporation ("Dayton") warrants for 12 monthsfrom the date of manufacture or for the duration of the publishedproduct shelf life, whichever is less, that at the time of shipmentby Dayton, the product is free of manufacturing defects andconforms to Dayton’s product properties in force on the date ofacceptance by Dayton of the order. Dayton shall only be liableunder this warranty if the product has been applied, used, andstored in accordance with Dayton’s instructions, especially surfacepreparation and installation, in force on the date of acceptance byDayton of the order. The purchaser must examine the productwhen received and promptly notify Dayton in writing of any non-conformity before the product is used and no later than 30 daysafter such non-conformity is first discovered. If Dayton, in its solediscretion, determines that the product breached the abovewarranty, it will, in its sole discretion, replace the non-conformingproduct, refund the purchase price or issue a credit in the amountof the purchase price. This is the sole and exclusive remedy forbreach of this warranty. Only a Dayton officer is authorized tomodify this warranty. The information in this data sheetsupersedes all other sales information received by the customerduring the sales process. THE FOREGOING WARRANTY SHALL BEEXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS ORIMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY ANDFITNESS FOR A PARTICULAR PURPOSE, AND ALL OTHERWARRANTIES OTHERWISE ARISING BY OPERATION OF LAW,COURSE OF DEALING, CUSTOM, TRADE OR OTHERWISE.
Dayton shall not be liable in contract or in tort (including,without limitation, negligence, strict liability or otherwise) forloss of sales, revenues or profits; cost of capital or funds;business interruption or cost of downtime, loss of use, damageto or loss of use of other property (real or personal); failure torealize expected savings; frustration of economic or businessexpectations; claims by third parties (other than for bodilyinjury), or economic losses of any kind; or for any special,incidental, indirect, consequential, punitive or exemplarydamages arising in any way out of the performance of, orfailure to perform, its obligations under any contract for saleof product, even if Dayton could foresee or has been advisedof the possibility of such damages. The Parties expressly agreethat these limitations on damages are allocations of riskconstituting, in part, the consideration for this contract, andalso that such limitations shall survive the determination ofany court of competent jurisdiction that any remedy providedin these terms or available at law fails of its essential purpose.
Form Release A
gents
Sec7
Clean Strip™ Ultra J3Form Release
TECHNICAL DATA SHEET
Visit www.daytonsuperior.com for the most up to date technical information
Page 2 of 2 File Date: 12/30/2014
DESCRIPTIONICS Construction Grout is a blend of portland cement, special admixtures and proprietary aggregates designed to provide high flexural and compressive strength performance from plastic to fluid consistencies. ICS Construction Grout is non-metallic, non-shrink, non-corrosive and contains no added chlorides.
USESICS Construction Grout is ideal for a wide variety of precision applications that include:• Machinery Grouting: Machinery bases, compressors, punch
presses, generators• Structural Grouting: Steel columns, precast columns, crane
rails, beams• Anchoring: Guard rails, sign posts, dowels, rods, bolts, post-
tension anchor heads
BENEFITS• Workability: Meets standards through a wide range of con-
sistencies• Thixotropic: High flow restored by agitation• Non-Corrosive: Will not rust• Cost Effective: Extendable• Strength: Attains high compressive strengths at specified
water ratios• Economical: Good performance and low cost• Performance: Joins, supports and anchors• Hardens free of bleeding or segregation• Consistent: Strict Quality Control testing and standards
STANDARDSICS Construction Grout has been specifically formulated to exceed the requirements of ASTM C1107 and Corp of Engineers CRD C621. When tested in accordance with ASTM C827, ICS Construction Grout yields a controlled, positive expansion.
SURFACE PREPARATIONAll surfaces in contact with ICS Construction Grout shall be free of dirt, oil, grease, laitance and other contaminants that may act as bondbreakers. All unsound concrete should be removed to ensure a good bond. Smooth, dense surfaces need to be mechani-cally abraded to provide necessary bonding requirements. Me-chanically prepare the substrate to a minimum CSP 5 following ICRI Guideline 310.2R to allow proper bonding. ACI recommends that the area to be grouted should be saturated for 24 hours before placement. Remove any standing water. Substrate should be saturated, surface dry (SSD). Maintain contact areas between 40°F (4°C) and 90°F (32°C) prior to grouting and during initial curing period.
FORMINGMethod of forming must provide for rapid, continuous grout placement. For pourable grout, construct forms to retain grout without leakage. Forms should be coated with a form release for easy removal.
MIXINGFor larger batches, use a mortar mixer with rotating blades. For smaller batches, use a heavy duty 1/2” (15 mm) (or larger) low-speed, corded drill and mixing paddle #6 per ICRI Technical Guideline 320.5. Pre-wet mixer and empty excess water. Place 3/4 of the required cool, clean potable water in mixer, then add
MIXING (continued)dry material. Mix on low RPM for a total of 3 to 5 minutes, adding the remaining water, until a homogeneous mixture is achieved. When using a mortar mixer higher RPMs may be necessary to achieve a homogeneous mixture. Mix only enough grout that can be placed within working time. For plastic consistency, use 3.5 quarts of water. For flowable consistency, use 4.0 quarts of water. For fluid consistency, use 4.5 quarts of water. These mix ratios provide a guideline. The actual water demand will depend on type of mixer used, water temperature and ambient temperature. Adjust the water to achieve the desired flow. Recommended flow is 20 to 30 seconds using the ASTM C939 Flow Cone Method. For placements greater than 3” depth, ICS Construction Grout must be extended 30% by weight of powder, with clean, washed and dried 3/8” (1 cm) pea gravel. Do not blend excess water as this will cause bleeding and segregation. Do not use any other admix-tures or additives.
PLACINGGrout should be placed using established procedures according to American Concrete Institute recommendations. ICS Construc-tion Grout can be placed by pumping, pouring, rodding or strap-ping. Mechanical vibration may cause segregation of aggregates. Place grout on one side of area. Let grout flow to opposite and adjacent sides to avoid entrapment of air and uneven bearing of the grouted surface. When necessary, provide vent holes. Grout should continue to be placed until it protrudes from the entire perimeter area. Grout “head” and excess grout may be removed after initial set.
FINISHING & CURINGFollow standard ACI curing practices. Do not disturb form-work or grout for 24 hours. Use wet rags or burlap to cure for 6 hours after placement. After 6 hours, remove rags from exposed surfaces and cure with a membrane forming curing compound. For best results, exposed grout should extend downward at a 45° angle from edge of base.
STORAGENormal cement storage and handling practices should be ob-served. Store in an interior, cool, dry place. Shelf life is one year in original, unopened container.
LIMITATIONSIn addition to limitations already mentioned, please note the fol-lowing. Do not apply when the surface or ambient temperature is below 40°F (4°C) or expected to fall below 40°F (4°C) within 48 hours. When grouting at minimum temperatures, ensure surfaces in contact with grout do not fall below 40°F (4°C) until final set has been achieved and grout has reached 3,000 psi. Do not apply over surfaces that are frozen or contain frost. Do not apply over any active faults or cracks in the substrate without addressing any movement that may occur. Do not use as a patching or overlay mortar or in unconfined areas. Setting time will speed up in hot weather and slow in cold weather. For hot and cold weather ap-plications, contact your ICS representative.
Packaging: 50 lb (22.7 kg) bag, 63 bags per pallet
ICS Construction GroutHigh Strength, Non-Shrink, Non-Corrosive Grout
03 60 00 GROUT
PHYSICAL PROPERTIESAll Physical Property testing performed in laboratory conditions of 73.5 ± 3.5°F (23 ± 2°C) and a relative humidity no less than 50% un-less otherwise determined by the test method or specification. All results represent ICS Construction Grout at a fluid (4.5 quarts) consistency unless listed otherwise. Tests are conducted under standardized conditions for comparative purposes, and results may not be representative of performance under field conditions. Property and Test Method Results
Compressive Strength ASTM C109 via C1107
B - PLASTIC3.5 qts
C - FLOWABLE4.0 qts
D - FLUID 4.5 qts
1 Day
3,500 psi(24.13 MPa)
3,000 psi (20.68 MPa)
2,000 psi(13.79 MPa)
3 Days
5,500 psi(37.92 MPa)
5,000 psi (34.47 MPa)
4,100 psi(28.27 MPa)
7 Days
6,500 psi(44.82 MPa)
6,000 psi (41.37 MPa)
5,000 psi(34.47 MPa)
28 Days
8,500 psi (58.61 MPa)
8,000 psi (55.16 MPa)
7,000 psi(48.26 MPa)
Rate of SetASTM C266
B - PLASTIC - 3.5 qtsC - FLOWABLE - 4.0 qts
D - FLUID - 4.5 qts
Working Time
:25:451:15
Initial
:521:152:00
Final
2:102:403:30
B - 100% - 125% flow table (ASTM C230, 5 drops in 3 seconds)C - 125% - 145% flow table (ASTM C230, 5 drops in 3 seconds)D - 28 second flow cone method (ASTM C939)
Flexural Strength ASTM C348
7 Days 800 psi
(5.51 MPa)
28 Days 1,200 psi
(8.27 MPa)
Density ASTM C138 137 lb/ft3 (2,195 kg/m3)
Modulus of Elasticity ASTM C469 2.83 x106 (19.48 GPa)
Splitting Tensile ASTM C496
28 Days 600 psi (4.13 MPa)
Scaling ResistanceASTM C672
Cycles 25
Scaled Material.04 kg/m2 (.008 lb/ft2)
Bond Strength ASTM C882
1 Day 1,300 psi
(8.96 MPa)
7 Days 2,000 psi
(13.78 MPa)
28 Days2,300 psi
(15.85 MPa)
Height Change ASTM C1090
1 Day+0.01%
3 Days+0.02%
7 Days+0.03%
28 Days+0.04%
Chloride Ion ContentASTM C1218 / C1152
Water Soluble .005 / .014
Acid Soluble.003 / .008
Effective Bearing AreaASTM C1339 >95%
Corrosion Resistivity GP Grout tested compatible with Vector Corrosion Technologies Galvashield embed-ded galvanic anodes.
DANGER This product contains Crystalline Silica (CAS# 14808-60-7) and Portland Cement (CAS# 65997-15-1). Harmful if swallowed. Causes skin irritation. Causes serious eye damage. May cause an allergic skin reaction. May cause cancer. May cause respiratory irritation. Causes damage to organs through prolonged or repeat-ed exposure. Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Contaminated work clothing must not be allowed out of the workplace. Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear protective gloves/protective clothing/eye protection/face protection. Use only outdoors or in a well-ventilated area. Do not breathe dust.
CALIFORNIA PROPOSITION 65: This product contains Crystalline Silica, Quartz (CAS# 14808-60-7) and may also contain other chemicals know to the State of California to cause cancer, birth defects or other reproductive harm.
FIRST AID If swallowed: Immediately call a poison center/doctor. Rinse mouth. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rins-ing. Immediately call a poison center/doctor. If on skin: Wash with plenty of water. Take off contaminated clothing and wash it before reuse. If skin irritation or rash occurs: Get medical advice/atten-tion. If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor if you feel unwell.
TECHNICAL SERVICE Contact your ICS representative for the most current product in-formation. Always read and follow the warnings and instructions on the most current technical data sheets.
Intermountain Concrete Specialties425 West 1700 SouthSalt Lake City, UT 84115Tel: 801.486.5311 Fax: 801.486.4520Web Site: www.ics50.com
Yield: 50 lbs (22.7 kg) will fill approximately 0.43 ft³ when 4.5 qts mixing water is used.
ICS Construction GroutHigh Strength, Non-Shrink, Non-Corrosive Grout
03 60 00 GROUT
Version 091515
NOTICE OF LIMITED WARRANTY US MIX Co. (manufacturer) warrants to buyer that this product at the time and place of shipment is of good quality and conforms to the man-ufacturer’s specifications in force on the date of manufacture when used in accordance with the instructions hereon. Manufacturer cannot warrant or guarantee any particular method of use, application or performance of the product under any particular condition. This limited warranty cannot be extended or amended by manufacturer’s sales, people, distributors or representatives or by any sales information, specifications of anyone other than the manufacturer. Liability under this warranty is expressly limited to refund of the purchase price. See product packaging for complete limitation of warranties and liability.
DESCRIPTION PERMINATOR underslab vapor barrier is a new generation of polyolefin-based resin/chemical technology. PERMINATOR provides the vapor barrier industry with a highly effective, economical choice for helping to reduce the penetration of moisture and water vapor through the slab into the structure, thereby helping to reduce fungus, mildew, and mold growth. PERMINATOR also helps reduce radon gas from entering the structure. New resin technology allows dramatically greater puncture resistance while maintaining one of the lowest perm ratings in the market. PERMINATOR is tough enough to withstand normal construction jobsite conditions and traffic. It will not crack, puncture, snag, split, or tear easily.
PERMINATOR prevents uncontrolled moisture from entering the slab allowing the slab to maintain the maximum slab moisture emission rate and relative humidity level as allowed by flooring manufacturer’s specifications.
PERMINATOR is available in 10 mil and 15 mil thicknesses. Both versions are furnished in 200’ (61 m) long rolls.
PERMINATOR’s 12’ (3.66 m) wide (15 mil) and 15’ (4.57 m) wide (10 mil) rolls require fewer seams in application. Installation is quick and easy. All joints/seams, both side and end, should be overlapped 6” (152.4 mm) and taped using 4” (101.6 mm) wide PERMINATOR TAPE from W. R. MEADOWS. PERMINATOR rolls fast and smoothly over level tamped soil or compacted fill.
USES PERMINATOR underslab vapor barrier is primarily designed for underslab construction, where the soil has been tamped and leveled or compacted fill has been applied. The 200’ (61 m) long sheets are unrolled as is or cut to size and installed using the overlapping method. Overlaps are 6” (152.4 mm) wide and these seams are sealed using 4” (101.6 mm) wide PERMINATOR TAPE.
PERMINATOR can also be used as a protection course for waterproofing membranes. The desired sheet lengths are cut to size and retained at the top of the waterproofing membranes by PERMINATOR TAPE or TERMINATION BAR from W R. MEADOWS.
FEATURES/BENEFITS Available in 10 mil and 15 mil thicknesses, in 200’ (61 m)
long rolls. Helps reduce the penetration of moisture and water vapor
through the slab into the structure. Helps reduce fungus, mildew, and mold. Helps reduce radon gas from entering a structure. Resistant to methane gas. Tough enough to withstand normal construction jobsite
conditions and traffic … will not crack, puncture, snag, split, or tear easily. Installs quickly and easily over tamped grade … no gravel,
fill, or sand needed. 12’ (15 mil) and 15’ (10 mil) wide rolls require fewer
seams in application. PERMINATOR prevents uncontrolled moisture from
entering the slab allowing the slab to maintain the maximum slab moisture emission rate and relative humidity level as allowed by flooring manufacturer’s specifications. 10 or 15 mil thickness clearly marked on membrane for
easy visual identification on jobsite. VOC content is 0 g/L. Made in America.
PACKAGING 10 mil: 15’ wide (4.57 m), 200’ long (60.96 m) or 54” wide (1.37 m), 400’ long (121.92 m) by special order only. 15 mil: 12’ wide (3.66 m), 200’ long (60.96 m)
SPECIFICATIONS Meets or exceeds all requirements of ASTM E 1745-11
Class A, B & C. ACI 302.2R: Guide for Concrete Slabs that Receive
Moisture Sensitive Flooring Materials makes a suggestion to use materials having 0.01 perms when flooring materials require protection lower than that determined by ASTM E 1745. PERMINATOR 15 mil meets this requirement.
PERMINATOR® 10 and 15 Mil Underslab Vapor Barrier
MasterFormat: 03 33 00 07 26 16 NO. 723 APRIL 2017
(Supersedes March 2016)
CONTINUED ON REVERSE SIDE…
TECHNICAL DATA
Properties PERMINATOR (10 Mil)
PERMINATOR (15 Mil)
Water Vapor Permeance ASTM E‐96 Perms
0.0183
0.0063
Puncture Resistance ASTM D 1709 Method B Grams
>3500
>3200
Tensile Strength ASTM E 154 Section 9 Lb. Force/Inch (kN/m)
52 (9.12)
72 (12.61)
Water Vapor Permeance After Wetting Out Drying Out and After Long‐Term Soaking ASTM E‐154 Section 8 ASTM E‐96 Procedure B
Perms
0.0219
0.0052
Water Vapor Permeance Resistance to Plastic Flow and Elevated Temperature ASTM E‐154 Section 11 ASTM E‐96 Procedure B
Perms
0.0197
0.0057
Water Vapor Permeance Effect Low Temperature and Flexibility ASTM E‐154, Section 12 ASTM E‐96, Procedure B
Perms
0.0212
0.0052
Water Vapor Permeance Resistance to Deterioration From Organisms and Substances in Contacting Soil ASTM E‐154, Section 13 ASTM E‐96 Procedure B
Perms
0.0198
0.0052
Radon Transmittance (m/s) k124/02/95
3.7 x 10‐8 8.7 x 10‐9
Radon Coefficient (m2/s) 9.4 x 10‐12 3.3 x 10‐12
PAGE 2 … PERMINATOR #723 … APRIL 2017
APPLICATION Surface Preparation … Level, tamp, or roll earth or granular material beneath the slab base as specified by supplied architectural drawings. Follow ASTM E-1643-10 (standard practice and procedure for installation of vapor retarder used in contact with earth or fill under concrete slabs). Reference American Concrete Institute (ACI) 302.1R-04: Chapter 4, Section 4.1.4 – Base Material for sub-grade preparation prior to placement of PERMINATOR.
Horizontal Application … Unroll 200’ (61 m) PERMINATOR over the area where the slab is to be poured. Cut to size if necessary. PERMINATOR should completely cover the pour area. All joints/seams, both side and end, should be overlapped 6” (152.4 mm) and taped using 4” (101.6 mm) wide PERMINATOR TAPE. (Note: The PERMINATOR TAPE area of adhesion should be free from dust, dirt, and moisture to allow maximum adhesion of the pressure-sensitive tape.)
The most efficient installation method includes placing PERMINATOR on top of the footing and against the vertical wall. This will sandwich PERMINATOR between the footing, vertical wall, and poured concrete floor. (See illustration on page 2.) This will help protect the concrete slab from external moisture sources once the slab has been placed.
Before placing concrete slab, make sure all penetrations, block outs, and damaged areas are repaired/addressed. Numerous municipal building codes do not allow the placement of vapor barriers over the footing, due to breaking of the bond between the wall and footing. Although this is not an optimal application method, W. R. MEADOWS approves this alternate method when required by building code. Figure 1 COLLAR
Seal All Protrusions … Cut a slit around pipes, ductwork, rebar, and wire penetrations to place the initial layer of PERMINATOR. To further protect the concrete slab from external moisture sources, use a piece of PERMINATOR and place a collar around this as well.
1. Cut a piece of PERMINATOR a minimum
width of 12” (304.8 mm). The length should be 1.5 times the pipe circumference. With a roofer’s knife or scissors, cut “fingers” half the width of the film. See Figure 1.
2. Wrap around and tape the collar onto the pipe and completely tape fingers to the bottom layer of PERMINATOR, as shown in Figure 2.
In the event that PERMINATOR is damaged during or after installation, repairs must be made. Cut a piece of PERMINATOR large enough to cover any damage by a minimum overlap of 6” (152.4 mm) in all directions. Clean all adhesion areas of dust, dirt, and moisture. Tape down all edges using PERMINATOR TAPE.
NOTE: It is not necessary to overlay PERMINATOR with gravel or sand. PERMINATOR is tough enough to withstand normal construction abuse and traffic. Most flooring companies recommend the placement of the concrete slab directly on the vapor barrier. We agree, since this eliminates the potential for trapping moisture in a blotter-effect, causing it to resurface through the slab into the flooring systems. Consult local building codes and regulations, plus architectural and design firm guidelines, prior to application. Figure 2: COLLAR INSTALLATION
PAGE 3 … PERMINATOR #723 … APRIL 2017
Vertical Wall Application … Install MEL-ROL®
waterproofing membrane or MEL-ROL LM liquid waterproofing membrane from W. R. MEADOWS according to installation instructions. While the membrane is still tacky, install PERMINATOR as a protective course over the applied waterproofing membrane. Using TERMINATION BAR with concrete nails or PERMINATOR TAPE at the termination of the waterproofing membrane is advisable in some applications. Supervised care must be taken during backfilling against the material so that it is not damaged or punctured. If damage occurs, patch using the techniques outlined previously. When applying PERMINATOR TAPE to foundation walls, MEL-PRIME™ adhesive from W. R. MEADOWS may be used to increase bond. ACCESSORIES MEL-DRAIN™ rolled matrix drainage system is designed to remove moisture from around footings and to relieve hydrostatic head pressures. Several different versions are available. MEL-ROL LM or POINTING MASTIC may be used for stakes, small pipe, and rebar penetrations. Cut PERMINATOR just big enough for the penetration. Liberally apply MEL-ROL LM or POINTING MASTIC around the penetration to keep the integrity of the PERMINATOR membrane intact. MEL-ROL LM can be applied by brush, roller, or sprayer. POINTING MASTIC can be applied by caulking gun or trowel.
PERMINATOR TAPE is a self-adhesive tape for use in sealing vapor barrier seams and attachment to footings, protrusions, etc. It is offered in 4” (10 cm) widths and roll lengths of 180’ (55 m)/roll. It is packaged twelve rolls per carton. Coverage: One box of tape will adhere approximately 10 rolls of PERMINATOR.
TERMINATION BAR is provided in 10’ (3 m) lengths to attach PERMINATOR to walls as a protection course for vertical surface waterproofing applications. PRECAUTIONS PERMINATOR underslab vapor barrier does not negate the need for relief of hydrostatic heads. A complete drain tile system should be placed on the exterior of the footing and, in severe cases, on the interior of the footing as well. For maximum concrete performance and durability, the concrete floor slab design should provide for the lowest possible slump, yet assure complete hydration of the concrete. Refer to Safety Data Sheet for complete health and safety information. LEED INFORMATION May help contribute to LEED credits: EAp2: Minimum Energy Performance EAc2: Optimize Energy Performance MRc9: Construction and Demolition Waste
Management
PAGE 4 … PERMINATOR #723 … APRIL 2017
© W. R. MEADOWS 2017 04/17-1M
For CAD details, most current data sheet, further LEED information, and SDS, visit
www.wrmeadows.com.