Joan Tresserras Pujol-Xicoy TALL BUILDING DRAFT DESIGN.

Post on 29-Mar-2015

222 views 1 download

Tags:

Transcript of Joan Tresserras Pujol-Xicoy TALL BUILDING DRAFT DESIGN.

Joan Tresserras Pujol-Xicoy

TALL

BUILDING

DRAFT DESIGN

Columns:• 1 – 5 floors:

1. Section dimensions

• 5 – 10 floors:

• 11 – 15 floors:

• 16 – 20 floors:

• 21 – 25 floors:

• 26 – 30 floors:

• 31 – 35 floors:

1. Section dimensions

Beams:

Slabs:

1. Section dimensions

2. Design requirements

2. Design requirements

Wind loading:

• According to the chinese code:

• Return period of 50 years Wp = 0,55KN/m2.

• Return period of 100 years Wp = 0,60KN/m2

• Building situated in Tianjin, China Roughness type C

• When using the program we choose the Chinese 2002 code

3. Loading

Earthquake loading:

• Design with a basic fortification intensity of 7.

• In consequence a ground acceleration of 0,15g is used.

• Site classification is a site-class IV.

• When using the program we choose the Chinese 2002 code.

3. Loading

Dead load:

• Automatically calculated the program (Self

Weight Multiplier = 1).

• It is necessary to add dead load to the slabs

inside the shear wall areas, due to their very

small thickness. These slabs help to transfer

lateral stresses.

• Add a dead load = 7,5kN/

3. Loading

Live load:

• Following the chinese code:

3. Loading

• Basically, the material used will be concrete.

Default concrete given by ETABS is a C40

concrete. For structural reasons a new

concrete C60 will be created.

• Steel only used in the reinforcement bars.

4. Materials

• A 3-D grid with all the elevation and plan

dimensions inputed has to be created.

5. Model elaboration

• It is convenient to create a

new set of columns every 5

stories to make it easy

when dimensioning them.

• In the first 4 floors the

columns that don’t have

floors on top will also be

different than the ones

with 35 floors on top

5. Model elaboration

• When drawing shear walls

it’s possible to distinguish

into two kinds of shear

walls:

• The ones surrounding the

elevators and stairs.

• In the residential floors,

the ones dividing the

different apartments.

5. Model elaboration

• There are two kinds of beams:

• Primary beams that go from column to column. The

moment release for this kind of beams will be continuous.

• Secundary beams that go from beam to beam. The

chosen distribution for this type of beams is a cross

distribution. The moment release for this kind of beams

will be pinned.

• No beams should be drawn inside the shear

walls.

5. Model elaboration

• Two kinds of slabs: 1.Normal slabs ; 2.Inside shear

walls slabs

5. Model elaboration

• Three requirements should be met by the model:• First rotation period / x or y period < 0,9

• Story drift < 1/800

• Maximum story drift / average story drift < 1,4

• To meet this three requirements a process of

analysis and later dimensioning of the structural

members will take place.

• It will be necessary to look at the different

modes of structure to determine which one is

the first to have rotation.

6. Model analysis

6. Model analysis

1st mode 2nd mode 3rd mode

6. Model analysis

Deformed shape 3-D View Longitudinal Reinforcing

6. Model analysis

First rotation period / x or y period < 0,9The first rotation period is the one of the third mode = 1,85398

The first period with x or y movement is the first mode = 2,50081

1,85398 / 2,50081 = 0,741352 < 0,9 Story drift < 1/800

The maximum story drift is for the 35th floor:

1/811 < 1/800 Maximum story drift / average story drift < 1,4

The maximum story drift is for the 1st floor= 1/811

Average story drift = 9,5992*10^(-4)

(1/811) / ( 9,5992*10^(-4)) = 1,285 < 1,4

7. Requirements

THANK YOU!

谢谢 !