Post on 03-Oct-2021
Sensor: 2.75”H x 3.88”W x 1.5”D Compatible control panels: Qolsys IQ Panel 2 Frequency: 319.5MHz Battery: 3V GP CR123A (x2) Operating Temperature: 14°F to 122°F Detection Range: 20ft Max and 5ft Min Intended for use with IQ Panel 2 Supervisory signal interval: 70 min (approximately)Intended for use with 3/16” and 1/4” plate or tempered glass.
SPECIFICATIONS
IQ GLASS S-LINE INSTALLATION MANUAL
Ceiling
Walls
✓
✓
Mounting Height: The sensor should be mounted between 6.5ft and 8.5ft above the floor. All protected glass must be within a clear line of sight of the sensor and within the 20ft max range.
Ceiling mount
Wall mount
CHOOSE INSTALLATION LOCATION
STEP
1
IQ GLASS-S
Note: for UL/cUL listed the device shall be secured using the provided mounting screws.
STEP
2STEP
3DETACH FACE PLATE
STEP
4STEP
5REPLACE FACE PLATE
SECURE TO SURFACE
REMOVE BATTERY TAB
Place your panel in “autolearn" mode
Open and close the case to “tamper” the device
Customize name and settings as desired and touch “ADD”
ADD
STEP
6LEARN INTO PANEL
Note: Detector LED will flash rapidly for 5 minutes as part of initial power up sequence.
Note: For UL/CUL installations use this device only in conjunction with compatible Qolsys wireless alarm system IQ Panel 2.
Document#: IQGS-IM-02-18 Revision#: 2/14/18 Issue Date: FEB 2018 Qolsys Product #: QS1431-840 TechSupport@Qolsys.com
CONTACT TECH SUPPORTGOT QUESTIONS?Qolsys Inc. proprietary.
Reproduction without permission is not permitted.FCC ID: 2ABBZ-RF-ARGB
IC: 11817A-RFARGB
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
TESTING MODE
STEP
7a
FG-701 Glassbreak Simulator
Test Mode: Place the sensor in test mode by disconnecting the batteries for 30 seconds then reconnecting. Test mode is active for 5 minutes upon the sensor powering on. The LED blinks every second when the sensor is in test mode. The IQ Glass-S does not transmit an RF Signal while it is in Test Mode. Please refer to the table on the right for the LED indicator guide. The sensor will exit test mode after the first 5 minutes of power up.
CONDITION RED LED
Initial Power Up
Test Mode
Test Mode, alarm event
Normal Mode, alarm event
Low Battery
Flash rapidly for 5 minutes
Flash once per second
Rapid flash for 2 seconds
SOLID for 5 seconds
Flash once every 30 seconds
LED Indicator Guide:
Sensitivity: Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The factory default is set to MAX. Please refer to the table below to customize the sensitivity.
ON
12
SENSITIVITY DETECTION RANGE
MAX
MEDIUM
LOW
LOWEST
20ft
1 2
13ft
8ft
5ft
OFF
ONOFF
OFF
OFF
ON
ON
ON
Switches: Set dip switches based on desired detection range.
ACTIVATE TEST FLEX MAN
Red StartButton
Set the FG-701 switches to the TEST and MANual modes.
Position the FG-701 near the protected glass and point the speaker directly at the glass break detector.
IMPORTANT: If window coverings are present, close them fully and hold the FG-701 behind the window coverings for testing.
Press the red start button and the FG-701 will generate a burst of glass break audio.
If the LED on the IQ Glass-S sensor flashes rapidly for 2 seconds an alarm event has been detected and the range is acceptable for audio. If the LED does not flash, position the IQ Glass-S closer to the glass and try again.
Note: The IQ Glass-S does not transmit an RF Signal while it is in Test Mode.
1.
2.
3.
To properly test the IQ Glass-S sensor, the FG-701 Glassbreak Simulator is required.
STEP
7b
STEP
7c
TESTING MODE
TESTING MODE
SECURE
CONNECTSUSING
319.5 MHz
EquipmentBP21056