Post on 12-Jul-2020
QUALITROL®509ITM Intelligenttransformermonitor
Improveassetprotection andutilization • ImmediatelyknowyourtransformerhealthwithTransLife™
• Optimizeloadingandequipmentlife
• Simplifyrootcauseanalysisforcondition-basedmaintenance
ProductSummary DescriptionAdvancedtransformermonitorfor
allparametersrequiredtoaccuratelytrackand
controlpowertransformers.Newcapabilitiesof
thedevicesuchasdatalogging,eventrecording
anddynamicloadinganalysishelptooptimize
loadingandmaximizeassetlife.
ApplicationRemoteandlocalmonitoringof
oil-filledtransformerandloadtapchanger
parameters,includingalarmingandadvanced
controlofcoolingsystems.
509_ITM_8page.indd 1 12/22/08 3:16:06 PM
QUALITROL®509ITMintelligenttransformermonitor
Improveassetprotection • Inadditiontotraditionalmechanicalmonitoringandprotection, andutilization electronictransformermonitoringfurtherimprovesreliability,safety, andtheavailabilityofkeydecisionmakinginformationbyautomating controlandmakinginformationavailableremotely • Expandedcapabilitiesandfeaturessuchasdirectwindingmeasurement arenowavailableinonesingledevice,enablinguserstoavoidinstallation, maintenianceandcapitalcostonadditionaldevices` Immediatelyknowyourtransformer • TransLife™featureprovidesadashboardofcriticalinformationneeded healthwithTransLife™ toeffectivelymanagetransformeroperation • Computeslossofassetliferate,lifeconsumptionandremainingassetlife • CriticalForecastfeaturedeterminesthetimeremaininguntilacritical temperatureisreachedbasedoncurrentconditions • ProvidesseparateTransLife™monitoringforupto3windings • TemperatureProfilerfeatureprovidesthehistoryofthe transformer’stemperature
Optimizeloadingandequipmentlife • Improvedaccuracygainedbyuseofdirectwindingoradvanced calculatedwindingtemperaturemeasurementpermitlesscontingency formeasurementerror,enablingsafeoperationathigherloads • Automaticcoolingbankswitchingnormalizesfanandpumpusage formaximumlife • Pre-coolingfunctionalitylimitsdamaginghightemperaturesproduced byoverloadsbyinitiatingthecoolingsystemwhenloadcurrentsexceed setpoints,ratherthanwaitingforoilorwindingtemperaturestorise • Adaptivesetbackimprovescoolingsystemefficiencybymeasuring ambienttemperatureandthenadaptingcoolingandalarmsetpoints basedontemperaturetrends • Lowtemperaturelock-outinsuresoilpumpsremainoffatcold temperaturestopreventstaticelectrificationandarcing • Seasonalsetbackallowsforcustomizedcoolingschemesdependingon thetimeoftheyear • Loadtapchangermonitorseriescandetectpropertapmovementand contactwear,andlogstappositionhistory.Alarmsforcontactloading (instantaneousandcumulative),excessivetapcountsovertime,false tapmovements,falseornomotormovement,motorandmechanism problems(overloading,breakage,binding)andworntapcontactsor cokingsothatactionscanbetakenbeforecriticalfailure • Coolingmonitorserieslearnsasitoperates;automaticallycalculates maximum,minimumandaveragevaluesfordeterminingsetpointsfor optimaloperation Simplifyrootcauseanalysis • Continuousinformationofallimportanttransformeroperatingparameters forcondition-basedmaintenance aidsin“drillingdown”totheroot,fundamentalcauseoftheproblem • Sequenceofeventsanddataloggingleaveatrailofallthetransformer’s parametersatthetimeofanalarm • Relaycontrolcontactsand“go/no-go”alarmsserveaseconomical, stand-aloneandautomatedmethodforremotelydeterminingstatusof atransformer
Flexibility • Flexiblemodularinputs(compatiblewithRTDs,CTs,voltages,current loops&switchcontacts)enableallparametersoftransformerstobe monitoredinoneintegrateddeviceandcanbefieldupgradedforfuture monitoringinputs • Newmatrixrelayscanbesettoalarmbasedonsetpoints,amatrixof setpointsanddifferencecalculations.Improvesidentificationof transformerissuesandreducesfalsetrips • Fourstandard0-1mAor4-20mAoutputsprovideinformationto SCADAsystems • Multiplemountingoptions:controlpanelconfigurations;self-contained corrosion/weatherproofenclosureconfigurations;19inchmount rackconfigurations • UtilizesdigitalprotocolsoverEthernet,RS-232,RS-485,orfiberoptics forintegrationwithtoday’scommunicationsystems
509_ITM_8page.indd 2 12/22/08 3:16:06 PM
509ITMintelligenttransformermonitorcapabilities
Emailinfo@qualitrolcorp.comwww.qualitrolcorp.com
Temperature
Thirdpartydevices
OillevelLoadcurrent
Pressure
Loadtapchanger
Coolingsystem
Control Information• Eventrecording• TransLife™• Datalogging• Predictiveloading• SCADAoutputs(0-1mAor4-20mA)• Digitalcommunication(RS485,RS232, fiberoptic,Ethernet)• Protocols(DNP,MODBUS,IEC61850,IEC60870)
• Coolingsystemoptimization• Localandremotealarms• Programmablerelays• Coolingsystemexerciser• Seasonalsetpoints• Ambientforecast
i
Monitorandmeasure
LTC
Analyzeandcommunicate
509_ITM_8page.indd 3 12/22/08 3:16:19 PM
QUALITROL®509ITMintelligenttransformermonitor
TransLife™,thereportcardfortransformers GeneralDescription
• TransLife™featureprovidesadashboardof criticalinformationneededtoeffectivelymanage transformeroperation • QUALITROL509ITMisahelpfultool tomanagetransformers,toprovidedatafor condition-basedmaintenanceandtoplan capitalexpenditures • Criticalforecastfeatureestimatesthetimeto reachcriticaltemperaturebasedonthepresent transformerload
• Temperatureprofilerrecordsthetimeatvarious temperaturesthatrelatetoassetlife,thisinformation isdisplayedgraphicallyforquickidentificationoftime spentatpeaktemperatures• Monitoringupto3windings,theQUALITROL509ITM receivesinputsfromoil,windingandambient temperaturetoreportlossofliferates,life consumption(dailyandhourly),totallossoflifeand remainingassetlife
TransLife™
Monitoringforupto3windings
TemperatureProfiler
Logsthedurationthatthetransformerisateachtemperaturerange
TransLife™Control
ContainsalltheselectionsofinputmeasurementsforTransLife™
ConsumedLife
Computeslossofassetliferate,lifeconsumed,remainingassetlifeandhoursinoperation
TemperatureProfilerGraph
Graphicalrepresentationofthetransformer’shistoricaltemperature
Redbarsprovidequickindicationoftimespentatacceleratedlifeconsumption
CriticalForecast
Determinesthetimeremaininguntilacriticaltemperatureisreachedbasedoncurrentconditions
509_ITM_8page.indd 4 12/22/08 3:16:21 PM
QUALITROL®509ITMintelligenttransformermonitorseries
509-100 intelligenttransformermonitor Forgeneraltransformercontrol • Monitorsmanystandardparameterssuchasliquidtemperature, windingtemperature,loadcurrent,oillevel,andmechanicalalarm
509-200 coolingmonitor Forgeneraltransformerandadvancedcoolingcontrol • Monitorsmanystandardparameterssuchasliquidtemperature, windingtemperature,loadcurrent,oillevel,andmechanicalalarm • Coolingmonitorserieslearnsasitoperates;automaticallycalculates maximum,minimum,andaveragevaluesfordeterminingsetpoints • Monitoringandalarmingbasedonenables
509-300 loadtapchangermonitor Forgeneraltransformerandloadtapchangermonitoring
• Monitorsmanystandardparameterssuchasliquidtemperature, windingtemperature,loadcurrent,oillevel,andmechanicalalarm • Monitorsdifferentialtemperature,tapposition,mechanism,motor performance,detectionofpropertapmovement,contactwearand loggingoftappositionhisto • Alarmsforcontactloading(instantaneousandcumulative),excessive tapcountsovertime,falsetapmovements,falseornomotor movement,motorandmechanismproblems(overloading,breakage, binding)andworntapcontactsorcoking
509DW directwindingmonitor Formonitoringonthemostcriticaltransformers
• Monitorsmanystandardparameterssuchasliquidtemperature, windingtemperature,loadcurrent,oillevel,andmechanicalalarm • Realtimecomparisonofdirectandcalculatedwindingtemperatures • Hotspottemperaturemeasurestheactualtemperatureswherever theprobeisinstalleddirectly • Maximizescoolingefficiencywithmoreaccuratehotspot temperaturemeasurement • Canbecombinedwithcoolingorloadtapchangermonitorseries
Emailinfo@qualitrolcorp.comwww.qualitrolcorp.com
509_ITM_8page.indd 5 12/22/08 3:16:40 PM
QUALITROL®509ITMintelligenttransformermonitor
Componentsandaccessories
PtandCuresistant • Providestransformertemperaturemeasurements temperaturedevices(RTDs) • Manyvarietiesavailabletocustomfithundreds oftransformerapplicationswitheasyupgrade todifferenttypesofequipment • MagneticRTDsavailableforeasyretrofitwhen wellsarenotavailable
AmbientRTD(103-047) • Forambienttemperaturemeasurementwithinsub station(closetotransformer) • Includessunshieldtopreventfalsereadings
Currenttransformers(CTs) • Measurescurrentflowneededtocalculate windingtemperature,monitorcoolingsystems andsuppportadvancedfunctions • Clip-ondesignsimplifiesinstallation
Pressuretransducers(TRN-603-1) • Monitorsstatictankpressureandcanprovide suddenpressureprotection (requiresQUALITROL930)
509_ITM_8page.indd 6 12/22/08 3:16:50 PM
TECHNICALSPECIFICATIONS
Powersupply Type Universal;90to264wattsVAC;47-63Hz,40-290VDC
Consumption <35watts Inputmodule Numberofinputs Acceptsupto8inputmodulesofvarious,configurabletypes parameters Accuracy ±0.5%full-scaleinputrange
RTD 10ohmcopper&100ohmplatinum -40°Fto248°Frange(-40°Cto120°C)
CT,windingtemperature Usesclamp-onsensor;range0to5,10,200amps
ACvoltage 0to140and0to360VACranges
Potentiometer Acceptspotentiometersfrom5Kto15K
Dryswitchcontact Measuresadryswitchcontactaswitheropenorclosed
Poweredswitchcontact Opticallyisolated;detectsACorDCfrom120to250volts
Tapposition Detectsresistorbridgesof40to1K;upto32resistors
Outputrelays Numberofrelays 8programmable,1systemstatus,1relayforheatercontrol
Type FormC,10amps@120/240VAC,10amps@30VDC
Outputcurrent Numberofloops 4magnetically-isolatedcurrentloops loop
Type Customerconfigurableinsoftwaretochoosebetween0-1mA (maxload450Ω)and4-20mA(maxload10,000Ω)
CommunicationsRS232port 1portforset-upcommunicationslocatedonthefrontpanel; varyingbaudrates
RS485port 1port,4-wireopticallyisolatedfordigitalprotocols
Fiberopticport STconnectors,820nmwavelength,maxdistance1500m
USBports 1typeB(slave)forlocalsetup,1typeA(master)fordatalogging downloadandconfigurationuploadwithUSBflashdrive Protocols DNP3.0level1slave,ModbusRTU,ASCII,IEC61850,IEC60870
Userinterface Control 8pushdownbuttonslocatedonfrontpanel
Localdisplay 2x16characterbacklitLCD
Environmental Operatingtemperature -40°Fto161.6°F(-40°Cto+72°C)
Storagetemperature -58°Fto185°F(-50°Cto+85°C)
Humidity 5%to90%non-condensing
Shock 10G’shalf-sine,inthreeorthogonalplanes
Vibration 60/120Hz@.004inchdisplacement;10/150Hzat1G
Immunity Dielectricstrength 2500VAC,60secondstoground
Surgewithstandcapability IEEEC37.90.1
Cond./radiatedemissions IEC61000-6-1
Cond./radiatedRFI IEC61000-6-2
Safety IEC61010-1 CEapproved Yes
Datalogging Numberofpoints Logsupto20parameters
Lograte Selectablefromoneminuteto24hours
Memorycapacity Memorysizecapableofstoring8parametersatonehourlograte forover19months.Shared32MBnon-volatileflashmemory
Eventrecording Numberofpoints Logsupto8events
Recordtypes 2recordtypes:timeanddateorcompletesystemsnapshot
Memorycapacity Memorysizecapableofstoring62,500timeanddateevents, shared32MBnon-volatileflashmemory
Emailinfo@qualitrolcorp.comwww.qualitrolcorp.com
509_ITM_8page.indd 7 12/22/08 3:16:51 PM
QUALITROL®509ITMintelligenttransformermonitor
Weatherproofenclosure
Panelmount
19”rackmount
Email:info@qualitrolcorp.com
www.qualitrolcorp.com
509ITMMOUNTINGHARDWARE(4PCS#1/4”CARRIAGEBOLTS(4PCS#1/4”LOCKINGNUTS
509ITMPANELMOUNTUNIT
INSTALLEDHERE
19”RACKPANEL19.0[482.6mm]
14.0[355.6mm]
HANDLE(2PCS)
©2008 QUALITROL® Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice. All trademarks are properties of their respective companies, as noted herein. AP-M09-02L-01E.