Post on 29-Sep-2015
description
SYSTEMENRICHTOELECTRICALTHE
SOLUTIONSDIGITAL
THE SOLUTIONS 3
THE SOLUTIONS
10 AUTOMATION SOLUTION FOR 5 SHUTTERS With BUS/SCS technology With Zigbee technology
20 AUTOMATION SOLUTION FOR 3 SHUTTERS AND 2 CURTAINS With BUS/SCS technology With Zigbee technology
31 LIGHT SCENARIO SOLUTION With BUS/SCS technology With Zigbee technology
50 LIGHT POINT ADDITION SOLUTION With Zigbee technology
56 SOUND DIFFUSION SOLUTION 1 SOURCE With BUS/SCS technology
61 SOUND DIFFUSION SOLUTION 2 MULTICHANNEL SOURCES With BUS/SCS technology
CONTENTS
WWW.BTICINO.COM
4SOLUTIONSTHE ADVANTAGES
of theThanks to our solutions it is possible to add new devices to the existing electric system, to expand and enrich the functions of the traditional system. This can be done using a wired or radio solution.
AUTOMATION OF CURTAINS AND SHUTTERSTo control the movement of one or more shutters/curtains around the whole home. One single touch is enough to raise or lower all the shutters/curtains of your home.
LIGHT SCENARIOSScenarios make life in your home much more simple and comfortable thanks to the simultaneous activation of several controls used daily.
THE SOLUTIONS 5
Thanks to the scenario control, the user can prepare the room for relaxation, reading, watching a film, etc. by ordering with a single movement the switching on or off of certain lights.
SOUND DIFFUSIONTo follow your favourite music program in each room of your home with a high sound quality, with perfect look integration.
WWW.BTICINO.COM
6TECHNOLOGY SELECTION of the
WIRED BUSThe transmission of all information among the devices added to the traditional electric system is performed through a twisted pair called BUS. The BUS cable transmits the information and the power supply to the devices and can be installed together with the existing energy cables. This solution is particularly suited for new constructions, or when important refurbishments have taken place.
WIRED BUS
TECHNOLOGY SELECTION SELECTION
WIRED
THE SOLUTIONS 7
RADIO ZIGBEE
RADIO ZIGBEEThanks to the radio transmission and the battery powering of controls, the devices easily integrate with the traditional electric system, without the need for any additional wiring. In this way the existing system can be integrated with the automation of lights and shutters.
RADIO ZIGBEE
WWW.BTICINO.COM
8PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
SOLUTIONSGUIDEto the
THE SOLUTIONS 9
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
FUNCTIONAL DIAGRAM
LIST OF DEVICES THAT MUST BE ORDERED
Below are all the steps to follow for the best possible installation of the ready-made solutions that we offer.
This document was created as a guide for the
users, and to provide them with all the necessary information to enable
them to enrich the electric system.
WWW.BTICINO.COM
22 2 2
2
2
10
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
Management of 5 motorized shutters or curtains using individual controls and the general control. This solution is particularly suited for new constructions or refurbishments.
In case control of several loads is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.
Legend of symbols:
Distribution board
Load control(general control)
Flush mounted actuator (single control)
BUS - SCS cable 230 Vac cable Shutter motor Junction box
Automation solution for 5 shutters with SCS BUS technology
Studio
Living Room HallwayBathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
THE SOLUTIONS 11
Actuator device for SINGLE control:
for local control of each individual associated/connected shutter. The type of control depends on the configurator connected to the M1 socket: MONOSTABLE, press and hold down the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device, until the desired shutter position is reached. BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After the command has been sent, press the lower or upper key cover again to stop the shutter in the desired position.
GENERAL control device:
to control the opening or the closing of all shutters at the same time. Configure the control for use in BISTABLE mode.
LOADS WHICH CAN BE DRIVEN
NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces
CONFIGURATION OF THE DEVICES
Description of the configurators
Configurator socket
Configurator
Pull-out handle
DescriptionPower supply from BUS
Absorption from BUS
Dissipated power at maximum load
Relay Type of load
Flush mounted 2 relay actuator
18 27 Vdc 13.5 mA 0.9 W
C
NO NO 2 A 500 W
DEVICE OPERATION DESCRIPTION
WWW.BTICINO.COM
NL230 Vac
N
L1 L2
N
L1 L2
N
L1 L2
N
L1 L2
N
L1 L2
BUS SCS
NL
230 Vac
1
2
4
3 3 3 3 3
12
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
NOTE (*):configure M1= 8 for BISTABLE operationconfigure M1= qr M for MONOSTABLE operation configure M1= qr for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.
Description q.ty BTicino Legrand Size (DIN)
1 Mini Power supply 230 Vac 1 E49 03567 2 modules
1 Power supply 110/127 Vac 1 346031 2 modules
TOTAL SIZE 2 modules
List of DIN module devices
Mini Power supply
General control
Single control
Single control
Single control
Single control
Single control
Vac
Vac
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
2 Control for single and double loads 1 L4652/2 H4652/2 573974 67241
3 Flush mounted actuator 2 relays 5 LN4671M2 H4671M2 573961 67249
Key cover UP/DOWN 2 modules 6
N4911M2AHN
NT4911M2AHN
L4911M2AHN
HD4911M2AH
HC4911/2AH
HS4911/2AH
574384
574385
68108
68408
4 SCS-BUS cable 1 L4669 L4669 49231 49231
Configurator GEN 1 3501/GEN 3501/GEN 49210 49210
Configurator 1 1 3501/1 3501/1 49201 49201
Configurator 2 1 3501/2 3501/2 49202 49202
Configurator 3 1 3501/3 3501/3 49203 49203
Configurator 5 1 3501/5 3501/5 49205 49205
Configurator 6 1 3501/6 3501/6 49206 49206
Configurator 8 1 3501/8 3501/8 49208 49208
Configurator qr 1 3501/T 3501/T 49220 49220Configurator qr M 1 3501/TM 3501/TM 49221 49221Pull-out handle 1 3502 3502 49265 49265
Ring 6 - - -68083
68383
List of flush mounted devices
FUNCTIONAL DIAGRAM
LIST OF DEVICES THAT MUST BE ORDERED
List of DIN module devices
Vac
Vac
List of flush mounted devices
A1 = GENM1 = qr
A1 = 5PL1 = 1 M1 = (*)
A1 = 5PL1 = 2 M1 = (*)
A1 = 5PL1 = 3 M1 = (*)
A1 = 6PL1 = 1 M1 = (*)
A1 = 6PL1 = 2 M1 = (*)
MPRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
PL1M1
A1
PL2M2
A2
BUS
BUS
Vac
MN
L1
L2
LN
BUS
THE SOLUTIONS 13
110
1) Control device for the general control of 5 shutters.
Actuator with key cover for local control
Junction box
NOTE 1): recommended height
Power supply
160
1)
Apartment switchboard
Control
Rear view
Mini Power supply
NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.
Front view
Actuator
2 A max500 W max
Rear view
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Control
110
1)
Junction box
WWW.BTICINO.COM
22 2 2
2
2
14
Automation solution for 5 shutters with ZigBee technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.
The new general control consists of a surface mounted radio control.
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
Studio
Living Room HallwayBathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
Legend of symbols:
Distribution board
Flush mounted radio actuator (single control)
230 Vac cable
Shutter motor Junction boxRadio control(general control)
DEVICE OPERATION DESCRIPTION
Single control radio actuator:
for local control of each individual associated/connected shutter. The control type can be: BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.
By pressing and holding down for more that one second the UP or the DOWN keys, it is possible to adjust the position of the blades.
General control:for radio control of the opening or closing of all the shutters at the same time. This is a BISTABLE type control, the same as described for the single actuator.
STOP control
UP control
DOWN control
4 s
THE SOLUTIONS 15
Description Power supply / Frequency Shutter motor
Radio actuator for shutter automations
230 Vac@50/60 HzMAX 500 VA MIN 270 VA
110 Vac@50/60 HzMax 250 VAMin 135 VA
PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4
seconds.
The Configuration of radio ZigBee devices is performed in three stages:
1. Selection of the coordinator device and network
creation. The coordinator device MUST be connected
to the electric power line.
2. Adding the devices to the network
3. Association of the devices
1 - Selection of the coordinator device and network creation
This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.
To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION
NETWORK pushbutton
LEARNING pushbutton
ON/OFF control key
LED STATUS
OFF
ON STEADY
FLASHING SLOWLY (1s)
FLASHING QUICKLY (0.25s)
FLASHING (60ms)
FLASHING 3 TIMES (3s)
3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.
4. Create the network by setting the devices that will be included, as indicated in the following page.
LEARNING indicator LED
NETWORK indicator LED
Coordinator
Coordinator
4 s
WWW.BTICINO.COM
A PL
16
2. Repeat the above procedure for all devices to include in the network.
3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.
2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.
The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.
3 s CoordinatorDevice
Device
To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,
while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.
Device Coordinator Device Device
CHECKING THE DEVICES BELONGING TO THE NETWORK
A PL
A PL
A PL
ML2
5
3
A PL
ML2
5
3
ML2
5
3
THE SOLUTIONS 17
3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.
5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.
7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.
1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least 1 second.
Control
Actuator
General control
6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.
4. Press the LEARNING KEY of the 1st ACTUATOR (shutters), the LEARNING LED (green) will flash slowly.
Control
Control
Actuator
Actuator
WWW.BTICINO.COM
N L
1
2
18
FUNCTIONAL DIAGRAM
Flush mounted radio actuator
Motorized shutter
NOTE: Repeat the connection for all 5 shutters.General control
LIST OF DEVICES THAT MUST BE ORDERED
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
1Radio actuator for shutter automation
5 LN4595 H4595573840 573841
67263
2Radio control for shutter automation
3N4599N (round cover plate)L4599N (square cover plate)
HA4599 (rectangular cover plate)HB4599 (round cover plate)
573842 573843
67264
Module key cover for actuator and UP/DOWN control
8N4911AHN NT4911AHN L4911AHN
HD4911AH HC4911AH HS4911AH
supplied68100 68400
Module key cover for actuator and NEUTRAL control
8N4911AN NT4911AN L4911AN
HD4915 HC4915 HS4915
supplied68081 68381
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
M
N L
ML2
5
3
THE SOLUTIONS 19
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
NOTA 1): recommended height
Radio actuator
Junction box
Radio control
Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.
15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).
Shutter actuator
150 metres
Radio control
15 metres
Wall
Shutter actuator
Radio control
N
L
N
L
110
1)
110
1)
WWW.BTICINO.COM
20
2
2 2 2
2
2
Actuator device for SINGLE control:
for local control of each individual associated/connected shutter/curtain. The type of control depends on the configurator connected to the M1 socket: MONOSTABLE, press and hold down the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device, until the desired shutter/curtain position is reached. BISTABLE, press and release the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter/curtain motor. After the command has been sent, press the lower or upper key cover again to stop the shutter/curtain in the desired position.
GENERAL control device:
to control the opening or the closing of all shutters/curtain at the same time. Configure the control for use in BISTABLE mode.
Automation solution for 3 shutters and 2 curtains with SCS BUS technologyManagement of 3 motorized shutters and 2 motorized curtains, with individual controls and 2 independent general controls. This solution is particularly suited for new constructions or refurbishments.
In case control of several users is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.
Load control(comandi generali)
Flush mounted actuator (single control)
SCS - BUScable
230 Vaccable
Shutter motor
Curtains motor
Junction boxDistribution board
Legend of symbols:
Studio
Living Room
HallwayBathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
THE SOLUTIONS 21
4
N
L1 L2
N
L1 L2
N
L1 L2
N
L1 L2
N
L1 L2
2 3 3 3 3 3
NL
1
BUS SCS
NL
DescriptionPower supply from BUS
Absorption from BUS
Dissipated power at maximum load
Relay Type of load
Flush mounted 2 relay actuator
18 27 Vdc 13.5 mA 0.9 W
C
NO NO 2 A 500 W
NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
Description of the configurators
Configurator socket
Configurator
Pull-out handle
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces.
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
FUNCTIONAL DIAGRAM
NOTE (*):configure M1= 8 for BISTABLE operationConfigure M1= qr M for MONOSTABLE operation Configure M1= qr for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.
Mini Power supply
General control
Single control
Single control
Single control
Single control
Single control
A1 = 5PL1 = 1 M1 = (*)
A1 = AMBPL1 = 5M1 = qrA2 = AMBPL2 = 6M2 = qr
A1 = 5PL1 = 2 M1 = (*)
A1 = 5PL1 = 3 M1 = (*)
A1 = 6PL1 = 1 M1 = (*)
A1 = 6PL1 = 2 M1 = (*)
Vac
Vac
WWW.BTICINO.COM
22
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
Description q.ty BTicino Legrand Size (DIN)
1 Mini Power supply 230 Vac 1 E49 03567 2 modules
1 Power supply 110/127 Vac 1 346031 2 modules
TOTAL SIZE 2 modules
List of DIN module devices
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
2 Control for single and double loads 1 L4652/2 H4652/2 573974 67241
3 Flush mounted actuator 2 relays 5 LN4671M2 H4671M2 573961 67249
Key cover UP/DOWN 2 modules 6N4911M2AHN NT4911M2AHN L4911M2AHN
HD4911M2AH HC4911/2AH HS4911/2AH
574384
574385
68108
68408
1 module UP/DOWN key 6N4911AHM NT4911AHM L4911AH
HD4911AH HC4911AH HS4911AH
574362
574363
68100
68400
4 SCS-BUS cable 1 L4669 L4669 49231 49231
Configurator GEN 1 3501/GEN 3501/GEN 49210 49210
Configurator 1 1 3501/1 3501/1 49201 49201
Configurator 2 1 3501/2 3501/2 49202 49202
Configurator 3 1 3501/3 3501/3 49203 49203
Configurator 5 1 3501/5 3501/5 49205 49205
Configurator 6 1 3501/6 3501/6 49206 49206
Configurator 8 1 3501/8 3501/8 49208 49208
Configurator qr 1 3501/T 3501/T 49220 49220Configurator qr M 1 3501/TM 3501/TM 49221 49221Configurator AMB 1 3501/AMB 3501/AMB 49221 49221
Pull-out handle 1 3502 3502 49265 49265
Ring 6 - - -68083
68383
List of flush mounted devices
LIST OF DEVICES THAT MUST BE ORDERED
THE SOLUTIONS 23
PL1M1
A1
PL2M2
A2
BUS
MN
L1
L2
LN
BUS
M
PRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
BUS
Vac
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Actuator
2 A max500 W max
Rearview
Actuator with key cover for local control
Junction box
Control device for the general control of three shutters and the general control of two curtains.
Control
Rear view
Apartment switchboard
Power supply
Front view
Mini Power supply
NOTE 1): recommended height NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.
110
1)
110
1)
160 1)
WWW.BTICINO.COM
24
2
2 2 2
2
2
Automation solution for 3 shutters and 2 curtains with ZigBee technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters and curtains, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.
The new general control consists of a surface mounted radio control.
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
Distribution board
Load control(general radio)
Flush mounted radio actuator (single control)
230 Vac cable
Shutter motor
Curtains motor
Junction box
Legend of symbols:
Studio
Living Room
HallwayBathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
UP control
DOWN control
STOP control
Single control radio actuator:
for local control of each individual associated/connected shutter. The control type can be: BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.
By pressing and holding down for more that one second the UP or the DOWN keys, it is possible to adjust the position of the blades.
General control:for radio control of the opening or closing of all the shutters at the same time. This is a BISTABLE type control, the same as described for the single actuator.
DEVICE OPERATION DESCRIPTION
THE SOLUTIONS 25
4 s
LOADS WHICH CAN BE DRIVEN
Description Power supply / Frequency Shutter/Curtain motor
Radio actuator for shutter/curtain automations
230 Vac@50/60 HzMAX 500 VA MIN 270 VA
110 Vac@50/60 HzMax 250 VAMin 135 VA
CONFIGURATION OF THE DEVICES
PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4
seconds.
The Configuration of radio ZigBee devices is performed in three stages:
1. Selection of the coordinator device and network
creation. The coordinator device MUST be connected
to the electric power line.
2. Adding the devices to the network
3. Association of the devices
1 - Selection of the coordinator device and network creation
This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.
To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.
3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.
4. Create the network by setting the devices that will be included, as indicated in the following page.
LEARNING indicator LED
NETWORK indicator LED
LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION
NETWORK pushbutton
LEARNING pushbutton
ON/OFF control key
Coordinator
Coordinator
LED STATUS
OFF
ON STEADY
FLASHING SLOWLY (1s)
FLASHING QUICKLY (0.25s)
FLASHING (60ms)
FLASHING 3 TIMES (3s)
WWW.BTICINO.COM
26
A PL
3 s
To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,
2. Repeat the above procedure for all devices to include in the network.
3. To complete the procedure press the NETWORK KEY of the Coordinator device; the corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.
while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.
Device Coordinator Device Device
2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.
The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.
CoordinatorDevice
Device
CHECKING THE DEVICES BELONGING TO THE NETWORK
THE SOLUTIONS 27
A PL
A PL
A PL
ML2
5
3
A PL
ML2
5
3
ML2
5
3
5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.
1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least 1 second.
General control for 3 shutters
4. Press the LEARNING KEY of the 1st ACTUATOR (shutters), the LEARNING LED (green) will flash slowly.
3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.
Control
Control
Control
Actuator
Actuator
Actuator
7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.
6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.
WWW.BTICINO.COM
28
A PL
A PL
A PL
ML2
5
3
A PL
ML2
5
3
ML2
5
3
4. Press the LEARNING KEY of the 1st ACTUATOR (curtains), the LEARNING LED (green) will flash slowly.
3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.
5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the curtains goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.
1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least 1 second.
Control
Control
Control
ActuatorActuator
Actuator
General control for 2 curtains
7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.
6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.
THE SOLUTIONS 29
N L N L
1 1
!
FUNCTIONAL DIAGRAM
Flush mounted actuator
Motorized shutter
Motorized curtain
NOTE: Repeat the connection for all shutters and curtains.
General shutter control
General curtain control
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
1Radio actuator for shutter automation
5 LN4595 H4595573840 573841
67263
2Radio control for shutter automation
3N4599N (round cover plate)L4599N (square cover plate)
HA4599 (rectangular cover plate)HB4599 (round cover plate)
573842 573843
67264
Module key cover for actuator and UP/DOWN control
11N4911AHN NT4911AHN L4911AHN
HD4911AH HC4911AH HS4911AH
supplied68100 68400
Module key cover for actuator and NEUTRAL control
11N4911AN NT4911AN L4911AN
HD4915 HC4915 HS4915
supplied68081 68381
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
LIST OF DEVICES THAT MUST BE ORDERED
WWW.BTICINO.COM
30
N
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
L
N
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
L
110
1)
M
110
1)
N L
ML2
5
3
2
2
2 2 2 2
NOTA 1): recommended height
Radio actuator
Junction box
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Radio control
Shutter actuator
150 metres
Maximum distancesThe maximum distance between 2 devices is: 150 metres on free field.
15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).
Radio controlRadio control
15 metres
Wall
Shutter actuator
EDC
B
A
H G
F
THE SOLUTIONS 31
Light scenario solution with star wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision,
wake-up), so that they may be recalled with a simple movement using the Scenario Control device. Solution realised with star wiring. All the actuators are in DIN module.
Scenario module:
it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.
Scenario control:
Its a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
Load controlDistribution board
Scenario control
Lamp BUS - SCS cable 230 Vac cable Junction box
Legend of symbols:
Studio
Living RoomHallway
Kitchen
Second bathroom
Child bedroom
Bedroom
Bathroom
WWW.BTICINO.COM
32
DescriptionPower supply from BUS
Absorption from BUS
Dissipated power at maximum load
Type of load
2 relay actuator
18 27 Vdc28 MA
(SINGLE LOADS)1.7 W
6 A / 1400 W (incandescence lamps and energy saving halogens) 10 a / 2300 w (resistive loads) 1 a / 250 w (linear fluorescent lamps) 250 w max 4 lampade (compact fluorescent lamps) 1 a / 250 w (electronic transformers) 2 a cos 0.5 / 500 va (ferromagnetic transformers)
2 x 400 W Multi load Dimmer Actuator
100 - 240 Vac @ 50/60 Hz
5 mA 8 W
1.7 A / 400 W (incandescence lamps and energy saving halogens) 1.7 A / 400 W (electronic transformers) 1.7 A / 400 W (ferromagnetic transformers)
WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces
Description of the configurators
Configurator socket
Configurator
Pull-out handle
Configurator
Configurator socket
Pull-out handle
CONFIGURATION OF THE DEVICES
LOADS WHICH CAN BE DRIVEN
ART.F420ART.F411/2
1 2 31 2 3 4
ART.F411/2
1 2 3 41 2 3 4
ART.F411/2
1 2 31 2 3 4
ART.F411/2
1 2 3 41 2 3 4
ART.F411/2
1 2 31 2 3 4
ART.F411/2
1 2 3 41 2 3 4
ON/+
OFF/-
RL/C
F417U2
2x400 VA
ON/+
OFF/-
MG2PL2G1
PL1A
NL
NL
A B C D E F G H
1
2
3
4 4
4
7
5 5 5 5 5
5
5
56 6
A A B C D E F G H
THE SOLUTIONS 33
FUNCTIONAL DIAGRAM
A1 = GENPL1 = M1 = O/IA2 = 1PL2 = 1M2 = O/I
AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I
A = PL = 1M = 1(*)N = DEL =
A1 = 2PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 2PL1 = 2M1 = O/IA2 = PL2 = M2 =
A1 = 3PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 3PL1 = 2M1 = O/IA2 = PL2 = M2 =
A = PL = 1M = 2(*)N = DEL =
A1 = 4PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 4PL1 = 2M1 = O/IA2 = PL2 = M2 =
A = 2PL1 = 1PL2 = 2G =
A = 3PL1 = 1PL2 = 2G =
A = 4PL1 = 1PL2 = 2G =
A1 = -PL1 = 1
A = 1PL1 = 1G1 = -PL2 = 2G2 = -M = -
Mini Power supply
Vac
VacScenario module
Dimmer actuator 2 relay
actuator2 relay actuator
2 relay actuator
Control Control Control Control ControlScenario control
NOTE(*): by inserting the same configurator in M, the scenario controls will activate the same scenarios.
Control ControlScenario control
WWW.BTICINO.COM
34
LIST OF DEVICES THAT MUST BE ORDERED
List of flush mounted devices
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
5 Control for single and double loads 8 L4652/2 H4652/2 573974 67241
6 Scenario control 2N4680 NT4680 L4680
HD4680 HC4680 HS4680
573902 573903
67217 67218
Key cover ON-OFF-GEN regulation 1 module
1N4911AFN NT4911AFN L4911AFN
HD4911AF HC4911AF HS4911AF
574373 (left) 574372 (left)
68105 (left) 68405 (left)
Key cover ON-OFF regulation 1 module
3N4911AIN NT4911AIN L4911AIN
HD4911AI HC4911AI HS4911AI
573964 (left) 573960 (right) 573965 (left) 573961 (right)
68264 (left) 68265 (right) 68564 (left) 68565 (right)
Key cover ON-OFF 2 modules 6N4911/2AGNNT4911/2AGNL4911/2AGN
HD4911M2AGHC4911/2AG HS4911/2AG
574382 574383
68085 68385
7 BUS - SCS cable 1 L4669 L4669 49231 49231
Configurator GEN 1 3501/GEN 3501/GEN 49210 49210
Configurator 1 1 3501/1 3501/1 49201 49201
Configurator 2 1 3501/2 3501/2 49202 49202
Configurator 3 1 3501/3 3501/3 49203 49203
Configurator 4 1 3501/4 3501/4 49204 49204
Configurator 0/1 1 3501/01 3501/01 49216 49216
Pull-out handle 1 3502 3502 49265 49265
Ring 8 - - - 68083 68383
Description q.ty BTicino Legrand Size(DIN)
1 Mini Power supply 230 Vac 1 E49 03567 2 modules
1 Power supply 110/127 Vac 1 346031 2 modules
2 Scenario module 1 F420 03551 2 modules
3 2 x 400 W Multi load Dimmer Actuator 1 F417U2 02622 6 modules
4 2 relay actuator 3 F411/2 03842 6 modules
TOTAL SIZE 16 modules
List of DIN module devices
ON
OFF
PRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
PL1M1
A1
PL2M2
A2
BUS
ON
OFF
ON
OFF
THE SOLUTIONS 35
WIRING AND ACTIVATION OF THE DEVICES
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
Front view
Mini Power supply
NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.
230 Vac
BUS
Apartment switchboard
Power supply and DIN actuator
NOTE 1): recommended height
Control device for the management of lights.
Control
Rear viewScenario control device
Dimmer light control device
160 1)
110 1)
WWW.BTICINO.COM
ON
OFF
ON
OFF
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
36
Procedure for programming a scenario: Procedure for deleting one or more scenarios:
1. In the scenario module press the programming enable pushbutton.
The corresponding LED turns green: the module is enabled.
2. Press the key to program for more than 4 seconds.
When the LED turns on release the key. The LED will start flashing, confirming that the programming mode is active.
3. Set the sequence of the commands making up the scenario.
t > 4 sec.
Press and hold down the key for the scenario to remove, waiting for the LED to come on and then to start FLASHING QUICKLY.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.
In the scenario module press the progr amming enable pushbutton.
The corresponding LED turns green: the module is enabled.
t > 8 sec.
To add, modify, or remove a command from the scenario repeat the sequence.
4. Press the key to complete programming.
To activate the scenario press the corresponding key.
At the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (F420). The corresponding LED turns red
ON
ON
ON
ON
Studio
Living Room
Kitchen
Second bathroom
Child bedroom
Bedroom
Bathroom
EDC
B
A
H G
F
THE SOLUTIONS 37
Legend of symbols:
Light scenario solution with distributed wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision, wake-up), so that
they may be recalled with a simple movement using the Scenario Control device. Solution created with distributed wiring. Flush mounted actuators are used when possible.
Scenario module:
it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.
Scenario control:
Its a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.
Load controlDistribution board
Scenario control
Lamp BUS - SCS cable
230 Vac cable
Junction box
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
Studio
Living Room Hallway
Kitchen
Second bathroom
Child bedroom
Bedroom
Bathroom
DEVICE OPERATION DESCRIPTION
WWW.BTICINO.COM
38
DescriptionPower supply from BUS
Absorption from BUS
Dissipated power at maximum load
Type of load
2X400 W Multiload Dimmer Actuator
18 27 Vdc28 MA
(SINGLE LOADS)8 W
6 a / 1400 w (incandescence lamps and energy saving halogens) 10 a / 2300 w (resistive loads) 1 a / 250 w (linear fluorescent lamps) 250 w max 4 lampade (compact fluorescent lamps) 1 a / 250 w (electronic transformers) 2 a cos 0,5 / 500 va (ferromagnetic transformers)
Control actuator
18-27 Vdc 14 mA 8 W
1.7 A / 400 W (incandescence lamps and energy saving halogens) 1.7 A / 400 W (electronic transformers) 1.7 A / 400 W (ferromagnetic transformers)
WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces.
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
Description of the configurators
Configurator socket
Configurator
Pull-out handle
Pull-out handle
Configurator
Configurator socket
ART.F420
ON/+
OFF/-
RL/C
F417U2
2x400 VA
ON/+
OFF/-
MG2PL2G1
PL1A
NL
NL 1
2
3
7
5
5
6
A B
C
D E F G H
A A B
C D E F G H
4 4 4 4 4 4
6
ART.F420
ON/+
OFF/-
RL/C
F417U2
2x400 VA
ON/+
OFF/-
MG2PL2G1
PL1A
NL
NL
C D E F G H
A A B
THE SOLUTIONS 39
FUNCTIONAL DIAGRAM
Mini Power supply Scenario
moduleDimmer actuator
Actuator/ Control
Actuator/ Control
Actuator/ Control
Actuator/ Control
Actuator/ Control
A1 = 2PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 2PL1 = 2M1 = O/IA2 = PL2 = M2 =
A1 = 3PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 3PL1 = 2M1 = O/IA2 = PL2 = M2 =
A1 = 4PL1 = 1M1 = O/IA2 = PL2 = M2 =
A1 = 4PL1 = 2M1 = O/IA2 = PL2 = M2 =
A1 = PL1 = 1
A = 1PL1 = 1G1 = PL2 = 2G2 = M =
Actuator/ Control
A1 = GENPL1 = M1 = O/IA2 = 1PL2 = 1M2 = O/I
AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I
A = PL = 1M = 1(*)N = DEL =
Control Control Scenario control
Scenario control
A = PL = 1M = 2(*)N = DEL =
NOTE(*): by inserting the same configurator in M, the scenario controls will activate the same scenarios.
Vac
Vac
WWW.BTICINO.COM
40
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
4 Flush mounted actuator/control 6 LN4671M2 H4671M2 573961 67249
5 Single and double load control 2 L4652/2 H4652/2 573974 67241
6 Scenario control 2N4680 NT4680 L4680
HD4680 HC4680 HS4680
573902 573903
67217 67218
Key cover ON-OFF-GEN regulation 1 module
1N4911AFN NT4911AFN L4911AFN
HD4911AF HC4911AF HS4911AF
574373 (left) 574372 (left)
68105 (left) 68405 (left)
Key cover ON-OFF regulation 1 module
3N4911AIN NT4911AIN L4911AIN
HD4911AI HC4911AI HS4911AI
573964 (left) 573960 (right) 573965 (left) 573961 (right)
68264 (left) 68265 (right) 68564 (left) 68565 (right)
Key cover ON-OFF 2 modules 6N4911/2AGNNT4911/2AGNL4911/2AGN
HD4911M2AGHC4911/2AG HS4911/2AG
574382 574383
68085 68385
7 BUS - SCS cable 1 L4669 L4669 49231 49231
Configurator GEN 1 3501/GEN 3501/GEN 49210 49210
Configurator 1 1 3501/1 3501/1 49201 49201
Configurator 2 1 3501/2 3501/2 49202 49202
Configurator 3 1 3501/3 3501/3 49203 49203
Configurator 4 1 3501/4 3501/4 49204 49204
Configurator 0/1 1 3501/01 3501/01 49216 49216
Pull-out handle 1 3502 3502 49265 49265
Ring 8 - - - 68083 68383
List of flush mounted devices
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
Description q.ty BTicino Legrand Size(DIN)
1 Mini Power supply 230 Vac 1 E49 03567 2 modules
1 Power supply 110/127 Vac 1 346031 2 modules
2 Scenario module 1 F420 03551 2 modules
3 2 x 400 W Multi load Dimmer Actuator 1 F417U2 02622 6 modules
TOTAL SIZE 10 modules
List of DIN module devices
LIST OF DEVICES THAT MUST BE ORDERED
PRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
PL1M1
A1
PL2M2
A2
BUS
ON
OFF
ON
OFF
THE SOLUTIONS 41
Apartment switchboard
Power supply and DIN actuator
Scenario control device
Dimmer light control device
NOTE 1): recommended heightNOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedica-ted thermal magnetic protection circuit breaker.
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Control
Rear view
Front view
Mini Power supply
230 Vac
BUS
160 1)
110 1
)
WWW.BTICINO.COM
ON
OFF
ON
OFF
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
42
ON
OFF
ON
OFF
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
DEL
ART.F420
Procedure for programming a scenario:
1. In the scenario module press the programming enable pushbutton.
The corresponding LED turns green: the module is enabled.
2. Press the key to program for more than 4 seconds.
When the LED turns on release the key. The LED will start flashing, confirming that the programming mode is active.
To add, modify, or remove a command from the scenario repeat the sequence.
3. Set the sequence of the commands making up the scenario.
4. Press the key to complete programming.
To activate the scenario press the corresponding key.
Procedure for deleting one or more scenarios:
Press and hold down the key for the scenario to remove, waiting for the LED to come on and then to start FLASHING QUICKLY.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.
In the scenario module press the programming enable pushbutton.
The corresponding LED turns green: the module is enabled.
ON
ON
At the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (F420). The corresponding LED turns red.
t > 4 sec.
ON
t > 8 sec.
ON
ON
OFF
THE SOLUTIONS 43
DIMMER radio actuator for light control:
for the local control of lamps and loads.Press and release the ON key to enable the load at 66% of its power. To increase the power at the maximum level, hold down the key. Press and release the OFF key to enable the load at 33% of its power. To decrease the power down to the minimum level, hold down the key.
Press the left key to switch the load on and off.
Legend of symbols:
Distribution board
Radio actuator 230 Vac cableLampScenario radio control
ON and adjustment pushbutton
OFF and adjustment pushbutton
ON/OFF pushbutton
Scenario 2
Scenario 4Scenario 3
Scenario 1
Scenario management radio control:
for the management of 4 scenarios, which can be saved and recalled using the control itself, or a remote control.
Radio remote control:
with 4 pushbuttons for scenario control.
Scenario 1
Scenario 2
Scenario 3Scenario 4
Light scenario solution with ZigBee technology Using radio dimmer and radio scenario control actuators, with the Zigbee technology it is possible to set light scenarios depending on the desired ambiance (e.g. relax, reading, watching TV, night).
The radio scenario control is capable of saving up to 4 scenarios maximum. Scenarios can also be recalled using a remote control.
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
Studio
Kitchen Bedroom
Living Room
HallwayBathroom
Second bathroom Child
bedroom
WWW.BTICINO.COM
44
DescriptionPower supply/ frequency
Incandescence lamps
Halogen lamps
Ferromagnetic lamps
Electronic transformers
Radio actuator DIMMER
230 Vac@50/60 HzMAX 300 W MIN 60 W
MAX 300 W MIN 60 W
MAX 300 W MIN 60 W
MAX 300 W MIN 60 W
110 Vac@50/60 HzMax 150 WMin 60 W
Max 150 WMin 60 W
Max 150 WMin 60 W
Max 150 WMin 60 W
PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4
seconds.
The Configuration of radio ZigBee devices is performed in three stages:
1. Selection of the coordinator device and network
creation. The coordinator device MUST be connected
to the electric power line.
2. Adding the devices to the network.
3. Association of the devices.
1 - Selection of the coordinator device and network creation.
This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.
To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.
3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.
4. Create the network by setting the devices that will be included, as indicated in the following page.
LEARNING indicator LED
NETWORK indicator LED
LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION
NETWORK pushbutton
LEARNING pushbutton
ON/OFF control key
Coordinator
Coordinator
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
LED STATUS
OFF
ON STEADY
FLASHING SLOWLY (1s)
FLASHING QUICKLY (0.25s)
FLASHING (60ms)
FLASHING 3 TIMES (3s)
4 s
A PL
THE SOLUTIONS 45
To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,
2. Repeat the above procedure for all devices to include in the network.
3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.
while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.
2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.
The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.
3 s CoordinatorDevice
Device
CHECKING THE DEVICES BELONGING TO THE NETWORK
Device Coordinator Device Device
WWW.BTICINO.COM
100 %
46
1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the SCENARIO CONTROL, the lEARNING LED (green) will flash slowly.
Procedure:
4. Press the LEARNING KEY of the first DIMMER ACTUATOR. The LEARNING LED (green) will flash slowly.
5. Press the ON KEY (bottom left) of the first DIMMER ACTUATOR. THE LEARNING LED (green) will start flashing quickly.
The scenario consists of the simultaneous activation of several loads, with the objective of creating a specific comfort situation. As an example, below is a description of the procedure for creating a scenario for switching ON two dimmer light points, one at 50% and one at 100% of its power.
Configuration of the scenario functions
3. Press KEY 1; the LEARNING LED (green) will start flashing quickly.
6. Press the LEARNING KEY of the second Dimmer actuator. The LEARNING LED (green) will flash slowly.
7. Press the ON KEY (bottom left) of the second Dimmer actuator. The LEARNING LED (green) will start flashing quickly.
Scenario control
Scenario control
Dimmer actuator
100 %
50 %
THE SOLUTIONS 47
9. Press the LEARNING KEY of the SCENARIO CONTROL. The LEARNING KEY (green) of the DIMMER ACTUATORS and of the SCENARIO CONTROL will switch off.
10. Check that the scenario has been programmed correctly by switching all the lights off and pressing pushbutton no. 1 of the SCENARIO CONTROL. If correctly set, the lights will switch on at the level set during the configuration procedure.
8. Press and hold down the KEY (bottom right) until the desired brightness value has been reached (e.g. 50%). The LEARNING LED (green) will start flashing quickly.
Scenario controlDimmer actuator 1
Dimmer actuator 2
WWW.BTICINO.COM
L L L
1 1 1
!"
48
FUNCTIONAL DIAGRAM
LIST OF DEVICES THAT MUST BE ORDERED
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
1 Radio actuator DIMMER 3 LN4593 H4593573816 573817
67237
2 Radio scenario control 1N4589N (round cover plate)L4589N (square cover plate)
HA4589 (square cover plate)HB4589 (round cover plate)
573848 573849
67240
3 Radio remote control 1 3528N 3528N 573870 573870
1 module light actuator key cover DIMMER symbol
3N4911AINNT4911AINL4911AIN
HD4911AI HC4911AI HS4911AI
supplied68265 68565
1 module light actuator key cover NEUTRAL
3N4915NNT4915NL4915N
HD4915BAHC4915BAHS4915BA
supplied68081 68381
1 module scenario control key cover
2N4911N NT4911N L4911N
HD4911 HC4911 HS4911
supplied68081 68381
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
Flush mounted radio actuator dimmer
Flush mounted radio actuator dimmer
Flush mounted radio actuator dimmer
Radio scenario controlRadio remote control
LON
OFF
N
L
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
N
L
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
THE SOLUTIONS 49
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.
15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).
Radio light actuator
Radio light actuator
Radio control
Radio light actuator
Junction box
Radio scenario control
150 metres
15 metres
Wall
110
1)
WWW.BTICINO.COM
50
Solution for the addition of a light point with ZigBee technologyThe Zigbee technology gives the possibility of adding a light point to manage the lighting of the room. The traditional switch is replaced by a radio actuator.
The new light point consists of a radio control surface mounted on the wall.
Radio actuator 230 Vac cableLampRadio control
Legend of symbols:
Distribution board
DEVICE OPERATION DESCRIPTION
ON/OFF radio actuator for light control:for the local control of lamps and loads
Radio control:for ON/OFF control of a group of radio actuators. Blank
plateON/OFF pushbutton
Studio
Living Room HallwayBathroom
Kitchen
Second bathroom
Child bedroom
Bedroom
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
THE SOLUTIONS 51
DescriptionPower supply/ frequency
Incandescence lamps
Halogen lampsFerromagnetic lamps
Electronic transformers
Radio actuator for light automation
230 Vac@50/60 HzMAX 400 W MIN 60 W
MAX 400 W MIN 60 W
MAX 400 W MIN 60 W
MAX 400 W MIN 60 W
110 Vac@50/60 HzMax 200 WMin 60 W
Max 200 WMin 60 W
Max 200 WMin 60 W
Max 250 WMin 135 W
LOADS WHICH CAN BE DRIVEN
CONFIGURATION OF THE DEVICES
PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4
seconds.
The Configuration of radio ZigBee devices is performed in three stages:
1. Selection of the coordinator device and network creation. The coordinator device MUST be connected
to the electric power line.
2. Adding the devices to the network
3. Association of the devices
1 - Selection of the coordinator device and network creation.
This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.
To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.
3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.
LEDS AND PUSHBUTTONS REQUIRED FOR THE CON-FIGURATION
LED STATUS
OFF
ON STEADY
FLASHING SLOWLY (1s)
FLASHING QUICKLY (0,25s)
FLASHING (60ms)
FLASHING 3 TIMES (3s)
4. Create the network by setting the devices that will be included, as indicated in the following page.
Coordinator
Coordinator
LEARNING indicator LED
NETWORK indicator LED
NETWORK pushbutton
LEARNING pushbutton
ON/OFF control key
4 s
WWW.BTICINO.COM
A PL
52
To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,
2. Repeat the above procedure for all devices to include in the network.
3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.
while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.
2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.
The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.
3 sDevice
CHECKING THE DEVICES BELONGING TO THE NETWORK
Device Coordinator Device Device
Coordinator
Device
A PL
A PL
A PL
A PL
THE SOLUTIONS 53
3. Press the ON KEY (bottom right). The LEARNING LED (green) will start flashing quickly.
NOTE: repeat the procedure described at points 2 and 3 for each command to be associated to the actuator.
5. Press the ON KEY (bottom right) on the ACTUATOR. The load connected turns on, the LEARNING LED (green) changes FLASHING mode, from slow to quick.
6. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.
3 - Association of the devices1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the RADIO CONTROL, the LEARNING LED (green) will flash slowly.
4. Press the ACTUATOR TO Associate to the LEARNING KEY. The LEARNING LED (green) will start flashing slowly.
Control
Control
Actuator
Actuator
Control
Actuator
WWW.BTICINO.COM
A PL
L
1
2
54
7. The devices are now associated: to check that the configuration procedure has been performed correctly press the OFF KEY on the radio control; the load connected to the actuator should go off.
Otherwise repeat the association procedure described.
FUNCTIONAL DIAGRAM
LIST OF DEVICES THAT MUST BE ORDERED
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
1 Light control ON/OFF radio actuator 1 LN4590 H45920573812
57381367231
2 Light radio control 1N4596N (round cover plate)
L4596N (square cover plate)
HA4596 (square cover plate)
HB4596 (round cover plate)
573834
57383567235
1 module key cover for actuator and light control 4
N4915AN
NT4915AN
L4915AN
HD4915BA
HC4915BA
HS4915BA
supplied68110 (right)
68410 (right)
Flush mounted ON/OFF radio actuatorRadio light Control
LN
L
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
N
L
TV/SAT IPTV
automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione
THE SOLUTIONS 55
Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.
15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).
Junction box
Radio actuator
Radio control
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
110
1)
Radio light actuator
Radio light actuator
Radio control
150 metres
15 metres
Wall
WWW.BTICINO.COM
ON
OFF
56
1 Source sound system solution with SCS BUS technologyThe 1 source sound system solution gives the possibility of installing a sound system in the room, with the option of following the favourite music program in each room,
with high sound quality. The installation is simple, flexible, and fast.
Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure); adjust the output volume (extended pressure); cycle through the saved radio stations.
Radio Tuner:its capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied with the product.
Studio
Living Room
HallwayBathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
Legend of symbols:
Distribution board
BUS - SCScable
Audio cableAmplifier Loudspeaker
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
Flush mounted stereo amplifier
False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.
PRI
SCS A-V SCS
346030
PRI: 220 - 240V~185-175mA50/60Hz
SCS A-V 27VdcSCS 600mA
ON
OFF
ON
OFF
ON
OFF
ON
OFF
BUS
1 2
3 3
4 4
5
6
THE SOLUTIONS 57
CONFIGURATION OF THE DEVICES
FUNCTIONAL DIAGRAM
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces
Description of the confi gurators
Confi gurator socket
Confi gurator
Pull-out handle
Line terminator
Amplifier
230 Vac
LIVING ROOM BEDROOMLoudspeaker Loudspeaker
Amplifier
Mini Power supply
In/out wiring
Radio Tuner
S = 1MEM = 2
A = 1PF = 1
A = 1PF = 2
WWW.BTICINO.COM
58
LIST OF DEVICES THAT MUST BE ORDERED
List of flush mounted devices
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
3 Flush mounting amplifier 2 L4562 H4562 573976 67302
1 module Diffusion functions
key cover2
N4911BNF
NT4911BNF
L4911BNF
HD4911BF
HC4911BF
HS4911BF
573966 (right)
573967 (right)
68263 (right)
68563 (right)
1 module ON-OFF & adjustment
key cover2
N4911AIN
NT4911AIN
L4911AIN
HD4911AI
HC4911AI
HS4911AI
573964 (left)
573965 (left)
68264 (left)
68564 (left)
4 False ceiling mounted loudspeakers 4 L4566/10 L4566/10 573982 573982
5 BUS - SCS cable 1 336904 336904 573999 573999
6 Line terminator 1 3499 3499 3589 3589
Configurator 1 1 3501/1 3501/1 49201 49201
Configurator 2 1 3501/2 3501/2 49202 49202
Pull-out handle 1 3502 3502 49265 49265
Ring 2 - - -68083
68383
Description q.ty BTicino Legrand Size(DIN)
1 Mini Power supply 230 Vac 1 346030 - 2 modules
1 Mini Power supply 110/127 Vac 1 346031 - 2 modules
2 Radio Tuner 1 F500N 03582 4 modules
TOTAL SIZE 6 modules
List of DIN module devices
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
ON
OFF
BUSPRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
THE SOLUTIONS 59
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
Flush mounted amplifier for the management of the sound source.
Apartment switchboard
Power supply and radio tuner
NOTE 1): recommended height NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.
110
1)
Amplifier
Rear view
BUS
Front view
Mini Power supply
Vac
Radio Tuner
160 1)
WWW.BTICINO.COM
A60
Quickly press and release the M pushbutton for the selection of the position number where the station will be stored.
The display shows the position where the station will be saved (A).
Press the forward/back pushbuttons to tune the radio to the desired frequency.
When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.
Once the desired station has been found, press and hold the M pushbutton until the two LEDs start flashing.
Release the pushbutton. The radio station has now been saved.
To save other stations repeat the same procedure.
The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.
Procedure for storing radio stations
ON
OFF
THE SOLUTIONS 61
2 multichannel sources sound system solution with SCS BUS technology
The 2 multichannel sources sound system solution gives the possibility of installing a sound system in the room, with the option of selecting the favourite sound source,
and have different music played in different rooms, with high sound quality. The installation is simple, flexible, and fast.
RCA input:provides interfacing, and the possibility of adapting the level of signal of an external source. The connection with the external source is by means of two female RCA connectors (red = right channel; white = left channel). The knob is used to adjust the sensitivity of the input signal. For optimum adjustment the corresponding LED must flash.
False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.
Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure); adjust the output volume (extended pressure); switch audio source; cycle through the saved radio stations.
Radio Tuner:its capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied.
PLANIMETRY FOR THE POSITIONING OF THE DEVICES
DEVICE OPERATION DESCRIPTION
Studio
Living Room
Hallway
Bathroom
Kitchen
Second bathroom Child
bedroom
Bedroom
Hallway
Legend of symbols:
Distribution board
BUS - SCS cable Audio cableAmplifier RCA input Loudspeaker
Flush mounted stereo amplifier
Flush mounting RCA input
Status notification LED
Sensitivity LED
WWW.BTICINO.COM
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
5
4 4 4
6 6 6
12
3
78
BUSON
OFF
ON
OFF
ON
OFF
62
FUNCTIONAL DIAGRAM
The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.
WARNING: the devices must only be configured when the system is not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces
CONFIGURATION OF THE DEVICES
Description of the confi gurators
Confi gurator socket
Confi gurator
Pull-out handle
Multichannel matrix
RCA input (*)
Line terminatorLine terminator
Power supply
LIVING ROOM/STUDIO BEDROOM
Loudspeaker
Radio Tuner
In/out wiring
OUT1 OUT2
WARNING(*): If the sound source connected to the RCA input is not battery powered, the source insulator must be used (item 3495 BTicino, item 573988 Legrand).
A = 1MEM = 2
S = 2
Loudspeaker Loudspeaker
VacS1 S2 BUS
A = 1PF = 2
A = 1PF = 1
A = 2PF = 1
THE SOLUTIONS 63
LIST OF DEVICES THAT MUST BE ORDERED
Description q.tyResidential series items
Livinglight Axolute Arteor Cliane
4 Flush mounting amplifier 3 L4562 H4562 573976 67302
1 module Diffusion functions
key cover3
N4911BFN
NT4911BFN
L4911BFN
HD4911BF
HC4911BF
HS4911BF
573966 (right)
573967 (right)
68263 (right)
68563 (right)
Key cover ON-OFF regulation
1 module3
N4911AIN
NT4911AIN
L4911AIN
HD4911AI
HC4911AI
HS4911AI
573964 (right)
573965 (right)
68264 (right)
68564 (right)
5 RCA input 1N4560
NT4560
L4560
HD4560
HC4560
HS4560
573926
573927
67301 (dispositivo)
68261 (cover)
68561 (cover)
6 False ceiling mounted loudspeakers 6 L4566/10 L4566/10 573982 573982
7 BUS - SCS cable 1 336904 336904 573999 573999
8 Line terminator 2 3499 3499 3589 3589
Configurator 1 1 3501/1 3501/1 49201 49201Configurator 2 1 3501/2 3501/2 49202 49202Pull-out handle 1 3502 3502 49265 49265
Ring 3 - - -68083
68383
Description q.ty BTicino Legrand Size(DIN)
1 Power supply 230 Vac 1 346000 63435 8 modules
1 Power supply 127 Vac 1 346001 573990 8 modules
2 Multichannel matrix 1 F441M 03584 10 modules
3 Radio Tuner 1 F500N 03582 4 modules
TOTAL SIZE 22 modules
List of flush mounted devices
List of DIN module devices
NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).
WWW.BTICINO.COM
ON
OFF
BUS
PRI
035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA
SCS
64
PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS
WIRING AND ACTIVATION OF THE DEVICES
110
1)
Flush mounted amplifier for the management of the sound source and RCA input device.
Amplifier
Rear view
BUS
160 1)
Apartment switchboard
NOTE 1): recommended height
Power supply, multichannel matrix, and radio FM tuner
Power supplyMultichannel matrix
Radio Tuner FM
S1
ATHE SOLUTIONS 65
Quickly press and release the M pushbutton for the selection of the position number where the station will be stored.
The display shows the position where the station will be saved (A).
Press the forward/back pushbuttons to tune the radio to the desired frequency.
When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.
Once the desired station has been found, press and hold the M pushbutton until the two LEDs start flashing.
Release the pushbutton. The radio station has now been saved.
To save other stations repeat the same procedure.
The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.
Procedure for storing radio stations
WWW.BTICINO.COM
Guida alla progettazione e allinstallazione
GU
IDA
TECN
ICA
2012
MH1
2GT -
Edizi
one 0
1/20
12BT
icino
S.p
.A. s
i rise
rva
il diri
tto d
i var
iare
in q
ualsi
asi m
omen
to i c
onte
nuti
del p
rese
nte
stam
pato
e d
i com
unica
re, in
qua
lsias
i form
a e
mod
alit
, i ca
mbi
amen
ti ap
porta
ti.
BTicino SpAVia Messina, 3820154 Milano - Italiawww.bticino.it
Per documentazione tecnica e informazioni di carattere commerciale
ORGANIZZAZIONE DI VENDITA E CONSULENZA TECNICA
Numero Verde
800-837035
Servizio Preventivazione gratuito
Numero Verde
800-293000
Numeri attivi dal luned al venerd dalle 8.30 alle 19.00 e il sabato dalle 8.30 alle 12.30
1JFNPOUFt7BMMFE"PTUBt-JHVSJBUFFICIO REGIONALE10098 RIVOLI (TO)c/o PRISMA 88 C.so Susa, 242Tel. Q 011/9502611Fax 011/9502666
-PNCBSEJBUFFICIO REGIONALE20154 MILANO Via Messina, 38Tel. Q 02/3480600Fax 02/3480610
7FOFUP0DDJEFOUBMFt 5SFOUJOP"MUP"EJHFUFFICIO REGIONALE37047 SAN BONIFACIO (VR)JJ CONSULTING SasLoc. Crosaron Villabella 18c/o SoavecenterTel. 045/7612497Fax 045/6104507
7FOFUP0SJFOUBMFt 'SJVMJ7FOF[JB(JVMJBUFFICIO REGIONALE35127 CAMIN PADOVAVia Vigonovese, 50Tel. Q 049/8993011Fax 049/8993066
&NJMJB3PNBHOBt 34.t.BSDIFUFFICIO REGIONALE40069 ZOLA PREDOSA (BO)Via Nannetti, 5/ATel. Q 051/6189911Fax 051/6189999
UFFICIO REGIONALE60019 SENIGALLIA (AN)Via Corvi, 18Tel. Q 071/668248Fax 071/668192
"CSV[[Pt.PMJTFt1VHMJBt#BTJMJDBUBUFFICIO REGIONALE70026 MODUGNO (BA)Via Paradiso, 33/GTel. Q 080/5352768Fax 080/5321890
5PTDBOBt6NCSJBUFFICIO REGIONALE50136 FIRENZEVia Aretina, 265/267Tel. Q 055/6557219Fax 055/6557221
-B[JPt$BMBCSJBt $BNQBOJBUFFICIO REGIONALE00153 ROMAViale della Piramide Cestia, 1pal. C - 4 piano - int. 15/16Tel. Q 06/5783495Fax 06/5782117
UFFICIO REGIONALE80040 S. MARIA LA BRUNATORRE DEL GRECO (NA)Via dellIndustria, 22Tel. Q 081/ 8479500 Fax 081/ 8479510
4JDJMJBUFFICIO REGIONALE95125 CATANIAVia G. Battista Grassi, 17/ATel. Q 095/7178883Fax 095/7179242
4BSEFHOBUFFICIO REGIONALE09100 CAGLIARI c/o centro Commerciale I MULINIPiano Primo int. 1Via Piero della Francesca, 3Localit Su PlanuTel. Q 070/541356Fax 070/541146
MY HOME
MH12GT
GUIDA TECNICA
ARTEORProject and installation guide
Rel
ease
07_
11
ARTEOR
ARTEOR
ARTEOR
Project and installation guide
Release 07_11
Release 07_11
CLIANEProject and installation guide
Rel
ease
07_
11
CLIANECLIANE
Project and installation guide
Release 07_11
Release 07_11
Release 07_11
Release 07_11
Numero Verde
800-293000XXX-XXXXXX
TO CU
STOM
IZETO TAKE ADVANTAGE OF OUR SERVICES CALL THE TOLL FREE NUMBER
BTicino provides its customers with technical support and quotation services. The objective is to offer to our customers a competent and fast service, working with alongside them as partners capable of providing answers to their needs, and helping them to select the best solutions for their systems.
MYHOME AUTOMATIONVIDEO DOOR ENTRY SYSTEM
Our services
CONTACT OUR CUSTOMER SUPPORT CENTRES
BTicino offers technical after sales service through authorised centres. For the conditions of the technical assistance service during the warranty period, the costs (for services not covered by the warranty), and the details of the closest CAT call this toll free number: XXX-XXXXXX or go to the Technical Service section of the Professionals Portal.www.bticino.com
For more information see our guides.
66
TO CU
STOM
IZETRAINING CENTRES
Attend training courses on BTicino systems and solutions: see the training section of the website.
WEBSITE
Always keep up to date thanks to our Professionals Portal: there you will find all the relevant product news, technical sheets, videos, and activities of BTicino.
SOFTWARE E SERVIZI 67WWW.BTICINO.COM
TO CU
STOM
IZEB
Tici
no S
pA re
serv
es a
t any
tim
e th
e ri
ght t
o m
odify
the
cont
ents
of t
his
book
let a
nd to
com
mun
icat
e,
in a
ny fo
rm a
nd m
odal
ity, t
he c
hang
es b
roug
ht to
the
sam
e.AD
- E
XCM
12SF
B/U
K -
Edi
tion
04/2
012
BTicino SpAVia Messina, 3820154 Milano - Italiawww.bticino.com