FOR YOUR SAFETY

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, injury, or death.

- Do not store or use gasoline or other flam-mable vapors or liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS: • Donottrytolightanyappliance.• Donottouchanyelectricalswitch;donotuse

any phone in your building. • Immediatelycallyourgassupplierfroma

neighbor’sphone.Followthegassupplier’sinstructions.

• Ifyoucannotreachyourgassupplier,callthefire department.

-Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagency,orthegassupplier.

POOL AND SPA/HOT TUB HEATERSH150FD, H200FD, H250FD, H300FD,

H350FD & H400FD MODELS

OWNER’S MANUAL

FOR YOUR SAFETYThisproductmustbeinstalledandservicedbyauthorizedpersonnel,qualifiedinpool/spaheaterinstallation.Improperinstallationand/oroperationcancreatecarbonmonoxidegasandfluegasesthatcancauseseriousinjury,propertydamage,ordeath.

1301640701 Rev C XXXX

HAYWARD ®

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Warnings ....................................................................................................3-6

Section I General information ........................................................................7

Section II. Consumer Operation & Maintenance ...........................................8

Using chlorinators and chemical feeders:......................................................9

Lighting & Operating instructions label ........................................................10

Operation: Set point adjustment .................................................................11

Fahrenheit versus Celsius ...........................................................................11

Sequence of operation ...............................................................................11

Failure to Light .............................................................................................12

Loss of flame – recycle ................................................................................12

Adaptive learning routine .............................................................................13

Keypad inputs ..............................................................................................13

Automatic reset time ....................................................................................13

Periodic inspection: .....................................................................................13

Winterization: ...............................................................................................14

Damage by Freezing ...................................................................................14

Spring start-up: ............................................................................................15

Error codes .............................................................................................15-16

Contents

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Basicsafetyprecautionsshouldalwaysbefollowed,includingthefollowing:Failuretofollowinstructionscancausesevereinjuryand/ordeath.

Thisisthesafety-alertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookforoneofthefollowingsignalwordsandbealerttothepotentialforpersonalinjury.

WARNINGwarnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormajorpropertydam-ageandifignoredpresentsapotentialhazard.

CAUTIONwarnsabouthazardsthatwillorcancauseminorormoderatepersonalinjuryand/orprop-ertydamageandifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthatareunpredictableandunsafe.

ATTENTIONindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.

ReAD AnD FoLLoW ALL InstRUCtIons In tHIs oWneR’sMAnUAL AnD on eQUIPMent.

IMPoRtAnt sAFetY InstRUCtIonsBefore installing or servicing this electrical equipment, turn power supply oFF.

KeeP sAFetY LABeLs In GooD ConDItIon AnD RePLACe IF MIssInG oR DAMAGeD.

WARNING–Toreduceriskofinjury,donotpermitchildrentouseorclimbontheheater,pumpsorfilters.Closelysupervisechildrenatalltimes.Componentssuchasthefiltrationsystem,pumps,andheatersmustbepositionedtopreventchildrenfromusingthemasameansofaccesstothepool.CAUTION –Thisheaterisintendedforuseonpermanentlyinstalledswimmingpoolsandmayalsobeusedwithspas.DoNOTusewithstorablepools.Apermanentlyinstalledpoolisconstructedinoronthegroundorinabuildingsuchthatitcannotbereadilydisassembledforstorage.Astorablepoolisconstructedsothatitiscapableofbeingreadilydisassembledforstorageandreassembledtoitsoriginalintegrity.

Thoughthisproductisdesignedforoutdooruse,itisstronglyrecommendedtoprotecttheelectricalcomponentsfromtheweather.Selectawelldrainedarea,onethatwillnotfloodwhenitrains.Itrequiresfreecirculationofairforcooling.Donotinstallinadampornon-ventilatedlocation.

WARNING –Itisrequiredthatlicensedelectriciansdoallelectricalwiring.RiskofElectricShock.Hazardousvoltagecanshock,burn,causedeathorseriouspropertydamage.Toreducetheriskofelectricshock,doNOTuseanextensioncordtoconnectunittoelectricsupply.Provideaproperlylocatedoutlet.AllelectricalwiringMUSTbeinconformancewithapplicablelocalandnationalcodesandregulations.Beforework-ingonthisunit,turnoffpowersupplytotheheater.

WARNING –Toreducetheriskofelectricshockreplacedamagedwiringimmediately.Locateconduittopreventabusefromlawnmowers,hedgetrimmersandotherequipment.

WARNING –Failuretobondtopoolstructurewillincreaseriskforelectrocutionandcouldresultininjuryordeath.Toreducetheriskofelectricshock,theelectricianmustcomplywithinstallationin-structionsandmustbondtheheateraccordingly.Inaddition,thelicensedelectricianmustalsoconformtolocalelectricalcodesforbondingrequirements.

sAFetY InFoRMAtIon

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

notes to tHe eLeCtRICIAn:Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-

forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedontheheaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(exceptgaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.

IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,bondingandothergeneralwiringprocedures.

WARNING – Suction Entrapment Hazard.Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-lowingentrapmenthazards:

Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.

Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutletcoverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultinamechanicalbindorswellingofthelimb.

Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscanresultinanentrapment.

Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotectedsuctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecuredcanresultinevisceration(disembowelment).

Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,finger,toeorknuck-letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-ment.

WARNING-Toreducetheriskofentrapmenthazards:• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.floororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-suredfromnearpointtonearpoint.

• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dualblockage”byauser.

• Dualsuctionfittingsshallnotbelocatedonseatingareasoronthebackrestforsuchseatingareas.

• Themaximumsystemflowrateshallnotexceedtheflowratingofanylisted(percurrentrevisionofASME/ANSIA112.19.8)suctionoutletcoverinstalled.

• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,ornotsecurelyattached.

• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-mediately.

• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

5

WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spafromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.

WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paperandothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.

WARNING–Suctionoutletcomponentshaveafinitelife,thecover/grateshouldbeinspectedfre-quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornotsecurelyattached.

WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.AlldrainsandsuctionoutletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.

WARNING – Hazardous Pressure.Poolandspawatercirculationsystemsoperateunderhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafetyandoperationinstructionscouldresultinviolentseparationofthepumphousingandcoverduetopressureinthesystem,whichcouldcausepropertydamage,severepersonalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,allsystemandpumpcontrolsmustbeinoffpositionandfiltermanualairreliefvalvemustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbesetinapositiontoallowsystemwatertoreturnbacktothepool.Donotchangefiltercontrolvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,fullyopenfiltermanualairreliefvalve.Donotclosefiltermanualairreliefvalveuntilasteadystreamofwater(notairorairandwater)isdischarged.

WARNING – Separation Hazard.Failuretofollowsafetyandoperationinstruc-tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbeproperlysecuredtopumphousingwithstrainercoverlockring.Beforeservicingpoolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Donotoperatepoolandspacirculationsystemifasystemcomponentisnotassembledproperly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunlessfilterairreliefvalvebodyisinlockedpositioninfilterupperbody.

WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.

WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperlyisolatedfromanyflammablestructuresorforeigndebristheycancausefires,whichmaycauseseverepersonalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriortomaintenancetominimizetheriskofburns.

WARNING–Failuretoinstallaccordingtodefinedinstructionsmayresultinseverepersonalinjuryordeath.

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

WARNING–Thefollowing“SafetyRulesforHotTubs”recommendedbytheU.S.ConsumerProductSafetyCommissionshouldbeobservedwhenusingthespa.

1. Spaorhottubwatertemperaturesshouldneverexceed104°F[40°C].Atemperatureof100°F[38°C]isconsideredsafeforahealthyadult.Specialcautionissuggestedforyoungchildren.Pro-longedimmersioninhotwatercaninducehyperthermia.

2. Drinkingofalcoholicbeveragesbeforeorduringspaorhottubusecancausedrowsiness,whichcouldleadtounconsciousnessandsubsequentlyresultindrowning.

3. Pregnantwomenbeware!Soakinginwaterabove100°F[38°C]cancausefetaldamageduringthefirstthreemonthsofpregnancy(resultinginthebirthofabrain-damagedordeformedchild).Preg-nantwomenshouldadheretothe100°F[38°C]maximumrule.

4. Beforeenteringthespaorhottub,usersshouldcheckthewatertemperaturewithanaccuratether-mometer;spaorhottubthermostatsmayerrinregulatingwatertemperaturesbyasmuchas4°F(2.2°C).

5. Personstakingmedications,whichinducedrowsiness,suchastranquilizers,antihistaminesoranti-coagulants,shouldnotusespasorhottubs.

6. Ifthepool/spaisusedfortherapy,itshouldbedonewiththeadviceofaphysician.Alwaysstirpool/spawaterbeforeenteringthepool/spatomixinanyhotsurfacelayerofwaterthatmightexceedhealthfultemperaturelimitsandcauseinjury.Donottamperwithcontrols,becausescaldingcanresultifsafetycontrolsarenotinproperworkingorder.

7. Personswithamedicalhistoryofheartdisease,circulatoryproblems,diabetesorbloodpressureproblemsshouldobtainaphysiciansadvicebeforeusingspasorhottubs.

8. Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegreesabovenormalbodytemperatureof98.6°F[37°C].ThesymptomsofHyperthermiainclude:drowsi-ness,lethargy,dizziness,fainting,andanincreaseintheinternaltemperatureofthebody.

The effects of Hyperthermia include:1. Unawarenessofimpendingdanger.2. Failuretoperceiveheat.3. Failuretorecognizetheneedtoleavethespa.4. Physicalinabilitytoexitthespa.5. Fetaldamageinpregnantwomen.6. Unconsciousnessresultingindangerofdrowning.

DEFINITIONS:SuctionOutlet– ThetermSuctionOutletisafitting,fittingassembly,cover/grateandrelatedcompo-

nentsthatprovideameansforwatertoexitthepoolandintothepumpcirculatingsystem.

InchesofMercury(inHg)- Aunitformeasuringpressurebelowatmospheric(“suction”or“vacuum”)(1.0inch

Hg=.491PSI)MainDrain– SeeSuctionOutletPSI– Anabbreviationforpoundspersquareinch.

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

IntRoDUCtIon:Thismanualcontainsinstructionsforinstallation,operation,maintenance,troubleshooting,andpartslists

forthesafeuseoftheswimmingpool/spa/hottubheaters.Haywardstronglyrecommendsthattheownerreadthemanualbeforeusingtheswimmingpool/spa/hottubheater.Ifafterreviewingthemanualanyques-tionsremainunanswered,contactthefactoryorlocalrepresentative.

LIMIteD WARRAntY sUMMARY:Wewarrantthepool/spa/hottubheatertobefreefromdefectsinmaterialsandworkmanship,andwe

willwithinoneyearfromdateofinstallationforallusers,fortheoriginalpurchaser,repairor,atouroption,replacewithoutchargeanydefectivepart.Wefurtherwarrantthatiftheheatexchangerorexchangerheaders(water-containingsection)leakwithinoneyearfromdateofsuchinstallationforallusers,duetodefectsinmaterialsandworkmanship,wewillprovideareplacementpart.Costoffreight,installation,fuel,andservicelabor(afteroneyear)isatuser’sexpense.Forfulldetailsofwarrantyagreement,seewarrantycertificateincludedinthismanual.

ATTENTION:Ifthepool/spa/hottubheaterisdamagedordestroyedbyimpropermaintenance,exces-sivewaterhardness,incorrectwaterchemistry,orfreezingitisnotcoveredunderthemanufacturer’swarranty.

seCtIon I. GeneRAL InFoRMAtIon

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

8 seCtIon II. ConsUMeR oPeRAtIon & MAIntenAnCe

FoR YoUR sAFetY – ReAD BeFoRe oPeRAtInG tHe HeAteR

GENERAL:Watermustbeflowingthroughtheheaterduringoperation.Checkthatthepumpisoperatingandthesys-

temisfilledwithwaterandpurgedofallairpriortostartingtheheater.Inanewpoolitisrecommendedthatthefilterbeoperatedlongenoughtocompletelycleanandclearthepoolwaterandfiltersystem.

Balancethepool/spawaterchemistryandcleanthefilter.Thenfollowtheinstructionsbelow.

POOL/SPA WATER CHEMISTRY:SeeFigure1.Themineralcontentofswimmingpoolwaterincreasesdailyduetoadditionofpoolsanitiz-

ingchemicalsandnaturalevaporation.Excessmineralswilldepositonpoolwalls,inthefiltrationsystem,andintheheatexchangertubesifthemineralcontentistoohigh.

Changingspawaterregularlyandmaintainingcorrectchemicalbalanceinpool/spawillkeepthepool/spasafeandsanitary,andwillprotecttheheateranditswarrantycoverage.PurchaseaPHwatertestkitandcheckthefollowingchemicallevelsfrequently.

CHLORINE OR BROMINE:Recommendedlevelis1to4ppm.Testbeforeuse.pH:Recommendedideallevel7.4to7.6.HIGHreadingsreducesanitizerefficiency.LOWreadingsarecorrosive.

TOTAL ALKALINITY:80–120ppm.Testweeklyduringregularuse.LOWreadingsarecorrosiveandcauserapidpHchangeswhenchemicalsareadded.

CALCIUM HARDNESS:200–400ppm.Testwheneverpool/spaisfilled.

LOWlevelsofhardnesscanbeverycorrosive.Remember,additionofanychemicalscanchangethelevelsofchlorine,pH,andtotalalkalinity.Itisrecommendedthatresidentialspawaterbechangedevery2to3monthstopreventwaterproblems.

Publicspasmayneedtohavethewaterchangedeveryweek,orevendaily,dependingonthebatherload.

Figure1

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

9

WARNING:Ifyousmellgasintheapplianceareaornearthefloor(PROPANEISHEAVIERTHANAIRANDHENCESETTLESONTHEFLOOR),stopandfollowtheinstructionsonthefrontcoverofthismanual.Sincepropanecanaccumulateincon-finedareas,extracareshouldbetakenwhenlightingpropaneheaters.

ATTENTION:Donotusetheheaterbelow40°F(4°C)temperaturewithoutadequatetemperaturepro-tection.

WARNING:Donotingestalcoholordrugsduringuseorpriortousingpool,spa,orhottub.Ingestionofsuchintoxicantscancausedrowsiness,whichcanleadtounconsciousness,andsubsequentlyresultindrowning.

USING CHLORINATORS AND CHEMICAL FEEDERS:Followtheinstructionsprovidedwithanyautomaticormanualchlorinatorandchemicalfeeder.All

chemicalsmustbeintroducedanddilutedintothepoolorspawaterbeforebeingcirculatedthroughtheheater.Donotplacechlorinetabletsorbrominesticksdirectlyintotheskimmer.Highchemicalconcentra-tionsmayresultwhenthepumpisnotrunning.Highchemicalconcentrationswillcauseveryrapidcorrosionoftheheatexchanger.ThisdamagewillnotbecoveredbytheHaywardwarranty.

HEATER OPERATION:Fulllightingandshutdowninstructionsareincludedonthelighting&operatinginstructionslabelaffixed

totheinsideofthefrontaccesspanel.SeeFigure2forthelocationofthislabelandthekeypad.SeeFigure3forthelabel.

Lighting&shutdownlabelislocatedontheinsideofthefront accesspanel

Removethese(4)screwstoremovethefrontaccesspane

Keypad

Figure2:Keypadandlabellocations

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

10

Figure3:Lighting&OperatingInstructionslabel

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

11

KEYPAD INPUTSThecontrolacceptsuserinputsviathekeypadonthefrontpanel.1. Whenchangingthemodefrom“STANDBY”toeither“SPA”or“POOL”theremaybeuptoa10-

seconddelayfortheblowerfantobeginrunning.Thecontrolperformsaninternalself-testandthenverifiesthattheblowervacuumswitchcontactsareopenbeforeenergizingtheblower.

2. Itisnormalfortheheatertodisplaya1-to2-seconddelayinrespondingtoanykeypadinput.3. Itisnormalfortheheatertodisplayuptoa5-seconddelaywhenthekeypadisusedtoresetthecon-

troltoclearanerrorcode.4. Thecontrolwillacceptamodechangeduringlockoutafter5seconds.Thecontrolwillcontinueto

displaytheerrorcodeandremaininlockoutuntilitisreset.Atresetthecontrolwillgotothelastsavedmode.

OPERATION: SET POINT ADjUSTMENT:Thesetpointtemperatureisdisplayedbypressingthe“UP”or“DOWN”buttonswhilein“POOL”or

“SPA”mode.Thesetpointwillblinkwhileitisdisplayed.Furtherpressingofthe“UP”or“DOWN”buttonswilladjustthesetpointtemperatureupordownasdesired.Thesetpointrangeisbetween65°F(18°C)and104°F(40°C).

FAHRENHEIT vERSUS CELSIUS:ThetemperaturecanbedisplayedinFahrenheitorCelsius.TOchangethedisplay,usethe“MODE”but-

tontoplacetheheaterin“STANDBY”.Thenpressandholdthe“UP”and“DOWN”buttonsuntilthedisplayshowsthe°F/°Cselection.Pressthe“DOWN”buttontotogglebetweenselections.Toaccepttheselection,pressthe“MODE”button.Iftheuserdoesnotact,theselectionwillbeautomaticallyacceptedafter60sec-onds.

WINTERIzATION:Inmoderateclimates,theheatercancontinuetooperateduringshort-termcoldspells.Donotusethe

heatertomaintainthewatertemperaturejustabovefreezingorforfreezeprotection.Caremustbetakentoavoidfreeze-upintheheater.Whenitisusedduringfreezingweather,thepumpmustruncontinuously.Theheaterisnotwarrantedagainstfreeze-ups.Inregionswherefreezingtemperaturesareencountered,allwatermustbedrainedfromtheheaterwhenitisoutofservice,topreventdamagetotheheaterandpiping.Drain-ingtheheatexchangerisrecommendedaspartoftheseason’sshutdownprocedures.

Figure4:Keypad KeypadImput

12

SPRING START-UP – CONSULT A PROFESSIONAL:1. Inspectandcleantheheater,beingsuretheheaterisfreeofleavesanddebrispriortostartup.2. Besureinletandoutletpipingareproperlyattachedtotheheaterandthedrainvalveisclosed.3. Turnthefiltrationsystempump“ON”andallowthesystemtorunlongenoughtopurgealltheair

fromthelines.4. Turnthegassupplytotheheater“ON”.5. Setthetemperaturecontrolusingthekeypadto“POOL”or“SPA”andadjustthesetpointtothe

desiredtemperaturesetting.6. Ifoperatingdifficultiesareencountered,contactaqualifiedservicecompanyforassistance.

ERROR CODES: Figure5liststheerrorcodesthatmaybedisplayedontheheaterdisplayboard. Contactaqualifiedservicecompanyforassistance.

Code Description Information

bDInternalfault/power-uperror

Oninitialtrialforignition.Automaticresetisimmediateoncethegasvalverelaycheckresultsareacceptable.

bDGasvalvesensedas“ON”error

Ifvalveisopenwhenitshouldbeclosedtheheaterwillshutdownandgointolockout.Blowerwilloperateuntilerrorconditioniscorrected.Automaticrestart2minutesaftererroriscorrected.

bDGasvalvesensedas“OFF”error

Ifvalveisclosedbutflameissensedtheblowerwillrunfor5sthenstartanewignitionsequence.Iferroroccurs10timesduringacallforheatthecontrolwillgointolockout.Automaticresetis60minutes.

bD Dataretrievalerror Ifcontrolinputdataiscorruptedtheheaterwillshutdownandgointolockout.

HFFlamepresentwithgasvalve“OFF”error

Ifflameissensedwiththegasvalveoffthecontrolwillgointolockout.Theblowerwillrununtilerrorconditioniscorrected.Whencorrected,controlwillrunblowerfor5sthenautomaticallyrestartafter2minutes.

PFElectricalsupplywiringerror

Thiscodewilldisplayif120Vpolarityisreversed,lowvoltageisdetected,orifthegroundpathisnotsufficient.Resetisimmediateaftererroriscorrected.

AOProverswitchopenerror

Iftheblowerproverswitchdoesnotcloseaftertheblowerstartsthecontrolwillstoptheignitiontrialgointolockout.Theblowerwillcontinuetorun.Automat-icresetisimmediateaftertheswitchcloses.

AO

Proverswitchopenwhenexpectedclosederror

Iftheblowerproverswitchopensunexpectedlyduringoperationthecontrolwillshutdownandattempttore-light.Iftheswitchdoesnotcloseaftertheblowerstartsthecontrolwillgointolockoutwiththeblowerrunning.Automaticresetisimmediateaftererroriscorrected.

Figure5:ERROR CODES

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

13

AOProverswitchopendur-ingpost-purgeerror

Iftheblowerproverswitchopensduringthepost-purgecycle(heaterisnotfir-ing)thecontrolwilldisplaytheerrorcode.Thepost-purgecyclewillbecom-pletedoncetheblowerproverswitchcloses.

ACProverswitchclosedwhenexpectedopenerror

Iftheblowerproverswitchisclosedbeforeblowerstart-upthecontrolwillnotstarttheblower.Automaticresetisimmediatewhentheswitchopens.

IOIgniteropenerror Ifthecontrolisnotinlockoutandsensesthattheignitercircuitisopenwhen

theblowerisrunningthecontrolwillturnofftheblowerandgointolockout.Automaticrestart2min.aftererroriscorrected.

SF

Thermistorerror Anexcessivetemperaturedifferencebetweenthetwothermistors(5°Formore)oran“outofbounds”conditiononbothsensors(lessthan10°Forgreaterthan180°F)willresultintheerrorcode.Automaticrestartis2minutesaftertheerroriscorrected.

HSExcessivewatertemperatureerror

Ifwatertemperatureexceeds105°Ftheheaterwillshutdownandgointolock-out.Automaticrestartis2minutesafterwatertemp.dropsbelow105°F.

HERapidwatertemperaturerise

Ifwatertemperaturerisestoorapidlytheheaterwillshutdownandgointolock-out.Automaticrestartisafter2minutes.Afterthethirdoccurrenceinthesamecallforheattheheaterwilllockout.

SbKeypadbuttonstuckclosederror

Ifoneofthekeypadbuttonsisclosed(orpressed)formorethan30stheerrorcodewillbedisplayedbutthecontrolwillcontinuetofunction.Theerrorcodewillbeclearedwhentheconditioniscorrected.

IFIgnitionfailureerror Ifthecontrolexceedsthemaximumnumberofignitionretriesorrecyclesthe

heaterwillshutdownandgointolockout.Automaticresetis60minutes.

CE

Communicationerror Ifcommunicationbetweentheignitionboardandthedisplayboardisnotestab-lishedwithin3sofpower-upanerrorwillbedisplayed.Aftercommunicationisestablished,ifitislostfor30s,theerrorwillbedisplayed.Theerrorcodewillbecleareduponavaliddataexchangebetweenboards.

LOLimitstringopenerror Ifthelimitstringopenstheheatershutsdownandgoesintolockout.Automatic

restartis2minutesaftertheerrorconditioniscorrectedandthelimitstringcloses.

EE EEPROMerror Anerrorwasdetectedintheignitioncontrolcircuitboard.

Figure5:ERROR CODES(continued)

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

14 HAYWARD PooL HeAteR CeRtIFICAte oF LIMIteD WARRAntY

Limitedheaterwarranty:TERMSANDCOVERAGE:Wewarrantourpoolheatertobefreefromdefectsinworkmanshipandmateri-alsundernormaluseandservice.PursuanttothiswarrantyandsubjecttotheConditionsandExceptionsindicatedbelow: 1.Wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)with

theprevailingcomparablemodel,or,atouroption,repairanypool/spaheaterthatleaksundernor-maluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.

2.Inaddition,wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)or,atouroption,repairanypartorpartsofthepool/spaheaterwhichmalfunctionsundernormaluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.

LIMITATION ON IMPLIED WARRANTIES:WEARENOTLIABLEFORANYCONSEQUENTIALDAMAGESFORBREACHOFANYWRITTENORIMPLIEDWARRANTYOFTHISPRODUCT.Im-pliedwarranties,includingtheWARRANTYofMERCHANTABILITYandallotherimpliedwarrantiesthatmayarisefromcourseofdealingorusageoftradeimposedonthesaleofthisheaterunderlawsofthestatearelimitedindurationtothetermofone(1)yearforallusers.Therearenowarrantieswhichextendbeyondthedescriptiononthefacehereof.Weshallnotinanyeventbeheldliableforanyspecial,indirect,orconse-quentialdamages.

eXPense oF DeLIVeRY AnD InstALLAtIon:Eachpoolheaterorreplacementparttobefurnishedunderthiswarrantyshallbefurnishedatournearest

distributioncenter.Weshallnotpay,norberesponsibleforshippingordeliverychargestotheplaceofinstal-lation,norforlaborchargesorothercostsofremovalorinstallation.Everydefectiveheaterorpartreplacedunderthiswarrantyshallbecomeourproperty,andassuch,mustbereturnedtoourdistributioncenterwithtransportationchargespaidbytheuser.Anyreplacementpoolheaterfurnishedunderthiswarrantyshallre-maininwarrantyonlyfortheunexpiredportionofthiswarranty.

ConDItIons AnD eXCePtIons:Thiswarrantyappliesonlytothepool/spaatitsoriginalplaceofinstallationandonlyfortheoriginal

owner.Itdoesnotapplyifthepoolheaterisinstalledinviolationofanyapplicablecodeorordinance,orisnotinstalled,operatedandmaintainedinaccordancewithourinstructions,orismisused,damagedbyac-cident,weather,actofGod,freezing,watervoidand/orexcesspressure,alteredordisconnected.Itdoesnotapplywithrespectto: 1.AheaternotequippedwithCertifiedC.S.A.limitcontrolsorequivalentpressurereliefvalve. 2.Aheateroperatedwithsettingsinexcessof,and/orwithfuelnotconformingtothoseshownonrat-

ingplate; 3.Aheateronwhichtheserialnumbershavebeenaltered,defaced,orremoved. 4.Leaksarisingfromdefectiveinstallation; 5.Productionofnoise,odors,ordiscolored(rusty,etc.)water; 6.Leakagesubstantiallycontributedtobysediment,limeprecipitateand/orhigherthannormaldis-

solvedsolids(pHabove7.8)inthetank,coppertubes,orwaterways; 7.Leakagecausedsubstantiallycontributedtobycorrosiveelementsintheatmosphere(suchasthe

storageofchlorineorotherchemicals); 8.Leakagecausedsubstantiallyorcontributedtobycorrosivepoolwaterinanacidcondition(pH

below7.2); 9.Damagecausedsubstantiallyorcontributedtobyanexternalsourceofenergy; 10.Apool/spaheaterisawatercontainingdevice.Leakageofwaterfromthisdevicecanbeexpected

atsometimeduetomalfunctionorthelimitations

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

15

oftheservicelifeofvariouscomponents.Donotinstallthisproductwheresuchleakagecancausedamage.MANUFACTURERISNOTRESPONSIBLEORLIABLEFORANYCOSTSINCURREDBYSUCHDAMAGE.

IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGETO SURROUNDING AREA OR PROPERTYCAUSED BY LEAKAGE OR MALFUNCTION.

HoW to CLAIM UnDeR tHIs WARRAntY: Theoriginalowner,upondiscoveringthedefect,mustpresenttheattachedcompletedwarrantyclaimcard

withproofofpurchaseeithertothedealerornotifytheCompanyinwritingateitheraddress:

HAYWARD PooL PRoDUCts, InC.620 DIvISIOn St.ELIzAbEth, nJ 07207

oR

HAYWARD PooL PRoDUCts, InC.2875 POMOnA bOULEvArDPOMOnA, CA 91768

Uponreceiptofsuchnotificationweshalldecidewhethertorepairsuchpartsorreplaceanypoolheater,reservingatalltimestherighttoinspectinordertoverifyanyclaimeddefect.Wealsoreservetherighttohaveourrepresentativesmakeanyinspections,repairs,ortofurnishreplacements.ThiswarrantyisintendedasalegallybindingobligationoftheCompany,enforceableinthecourts.Thiswarrantymaygiveyouspe-cificlegalrightswhichmayvaryfromstatetostate.

LIMItAtIon on LIABILItY: Allintendedrepresentationshavebeenexpresslysetforthinthisdocument.Thiswarrantymaynotbe

extendedbyoraloranyotheradditionalrepresentations,writtensalesinformation,drawings,orothermal-function,isstrictlylimitedtorepairorreplacementofthedefectiveheaterorpart,asprovidedhereinandtheCompanyisnotresponsiblehereunderforincidentalorconsequentialorincidentalcostsordamages.Thecompanyneitherassumes,norauthorizesanypersonorfirmtoassumeforus,anyfurtherliabilityorobligationinconnectionwiththesale,installation,use,maintenance,orexistenceoftheheater.SAFETYWARNING:Poolheatersareheatproducingappliancesandtoavoiddamageorinjuryintheeventofpos-sibleoverheatingoftheouterjacket(1)nomaterialsshouldbestoredagainstthejacketand(2)careshouldbetakentoavoidunnecessarycontact(especiallybychildren)withthejacket.Whenlightingagasheater,thelightinginstructionsmustbefollowedexactlytoprevent“flashback”ofexcessgasintheheater.Electronicignitionheatersandelectricheatersmusthavethepowershutoffwhenmakingadjustmentsto,servicing,orcomingintocontactwiththeheater.UNDERNOCIRCUMSTANCESSHOULDFLAMMABLEMATERI-ALS,SUCHASGASOLINEORPAINTTHINNERS,BEUSEDORSTOREDINTHEVICINITYOFTHEHEATERORINANYLOCATIONFROMWHICHFUMESCOULDREACHTHEHEATER.Foryourcomfort,enjoymentandsafety,pleasereadtheenclosedoperatinginstructionscarefully.

Hayward Pool Products, Inc.620 Division St.Elizabeth, nJ 07207

Hayward Pool Products, Inc.2875 Pomona boulevardPomona, CA 91768

Hayward Pool Products, Inc.2880 Plymouth DriveOakville, Ontario L6h 5r4

Hayward S.A.zoming de Jumetb6040 Jumet, belgique

© 2004 Hayward Imprimé aux U.S.A.