Gsg Pictures

Post on 11-Apr-2015

262 views 0 download

Transcript of Gsg Pictures

Sulzer ISO 13709 (API 610) Type BB5 Barrel Pumps

Some GSG’s like this 80-260 / 5 stage are so small that we can’t make a barrel shorter than 4 or 5 stages…the discharge flange would interfere with the suction flange.

For 3 or 4 stage performance, those pumps are destaged and a blank stage cylinder channels flow through the unused stage area.

Pictures

Pictures

GSG Boiler Feed pump with speed increasing gearbox, lube system, suction strainer and automatic recirculation control valve

Pictures

GSG portion of hydrotreater train (GSG pump, clutch, MSD-T power recovery turbine) with full instrumentation and insulation.Sleeve bearing RTD, Active Thrust RTD, Inactive thrust RTD, X-Y vibration probes, Key phasor.

Pictures

10 stage GSG on 0.4 Sp.Gr. cold Ethylene

VFD driven at > 4000 RPM with fan cooled antifriction bearings

• GSG pumping ethylene at -55 °C

GSG for ethylene

• GSG pumping ethylene at -55 °C

GSG for ethylene

GSG for ethylene

• GSG 50-215/10 stpumping ethylene at -55 °C

(2) GSG’s modularized for offshore platform

Pictures

Pictures

GSG’s for charge service.

Tandem Seals with Plan 52,

X-Y Vibration probes on pump & motor,

Cooling water piping.

Surgutneftegas

Surgutneftegas