GRIMM EDM 180 Dust Monitor - US EPA19” Stationary Dust Monitor EDM 180 APPROVED by U.S. EPA As a...

Post on 02-Aug-2020

0 views 0 download

Transcript of GRIMM EDM 180 Dust Monitor - US EPA19” Stationary Dust Monitor EDM 180 APPROVED by U.S. EPA As a...

GRIMM EDM 180 Dust MonitorPresented at;

NAQC-EPA

Monitoring Conference

Denver, Colorado

May 14th 2012

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 2

19” Stationary Dust Monitor EDM 180

APPROVED by U.S. EPAAs a Class III Equivalent Method Designation

for the measurement of PM 2.5

Automated Equivalent Method: EQPM-0311-195

Federal Register: Vol. 76, page 15974, 03/22/2011

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 3

Optical Technology

Giving you multiple PM values

Simultaneously

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 4

Principle of

Operation

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 5

Grimm Laser Aerosol Spectrometerfunctional principle, light source with laser diode

Grimm optical cell like in 180

• Light source by compact laser diode with

multiplex mode, low power consumption

and good temperature stability

• Collimator generates laser curtain

with homogeneous optical field

• Light trap assures low noise due to

very low indirect scattering light

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 6

Grimm Laser Aerosol Spectrometerfunctional principle, aerodynamic aerosol focusing

Grimm optical cell like in 180by compact

laser diode with

multiplex mode, low power consumption

and good temperature stability

• Collimator generates laser curtain

optical field

• Light trap assures low noise due to

very low indirect scattering light

• Inlet focus particles aerodynamically

into optical field, no border zone error

• Rinsing air circuit and outlet nozzle

design assure straight pass through

the laser, no vagabonding particles

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 7

Grimm Laser Aerosol Spectrometerfunctional principle, PIN diode and wide field reflector

Grimm optical cell like in 180

• Light source by compact laser diode with

multiplex mode, low power consumption

and good temperature stability

• Collimator generates laser curtain

with homogeneous optical field

• Light trap assures low noise due to

very low indirect scattering light

• Inlet focus particles aerodynamically

into optical field, no border zone error

• Rinsing air circuit and outlet nozzle

design assure straight pass through

the laser, no vagabonding particles

• Fast and robust photo diode detector for

90° scattering light detection

• Special wide field reflector improves

detection limit for small particles and

reduces sizing effects by refractive index

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 8

Grimm Laser Aerosol Spectrometerfunctional principle, output data and gravimetric filter

Grimm optical cell like in 180

•t source by compact laser diode with

multiplex mode, low power consumption

and good temperature stability

• Collimator generates laser curtain

with homogeneous optical field

• Light trap assures low noise due to

very low indirect scattering light

• Inlet focus particles aerodynamically

into optical field, no border zone error

• Rinsing air circuit and outlet nozzle

design assure straight pass through

the laser, no vagabonding particles

• Fast and robust photo diode detector for

90° scattering light detection

• Special wide field reflector improves

detection limit for small particles and

reduces sizing effects by refractive index

• 31 size channels, 6 sec. time resolution,

PM10, 2.5,1 or TSP or PMc

• Built in 47mm PTFE filter for gravimetric

mass validation

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 9

Grimm Laser Aerosol Spectrometerfunctional principle

Grimm optical cell like in 180

• Light source by compact laser diode with

multiplex mode, low power consumption

and good temperature stability

• Collimator generates laser curtain

with homogeneous optical field

• Light trap assures low noise due to

very low indirect scattering light

• Inlet focus particles aerodynamically

into optical field, no border zone error

• Rinsing air circuit and outlet nozzle

design assure straight pass through

the laser, no vagabonding particles

• Fast and robust photo diode detector for

90° scattering light detection

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 10

� Measure Both PM10 and PM2.5

� Real-Time Measurement (6 sec)� No Consumable� No Zero Drift� Minimal Maintenance� Quick & Easy Audit

Technology Benefits

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 11

19” Stationary Dust Monitor EDM 180

Easy Rack Mount Installation

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 12

19” Stationary Dust Monitor EDM 180

1.5 mExtension

for

Total length

of

3.0 m(2 m above roof)

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 13

Nafion Dryer Under Vacuum

19” Stationary Dust Monitor EDM 180

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 14

19” Stationary Dust Monitor EDM 180

Looking inside the 180

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 15

# 157L

Temperature

Relative Humidity

Pressure

Optional Met Sensors for EDM 180

# 158L

Temperature

Relative Humidity

Pressure

Wind Direction

Wind Speed

# 159L

Temperature

Relative Humidity

Pressure

Wind Direction

Wind Speed

Precipitation

• New Ultrasonic Wind Sensor

with no moving parts.

• New doppler rain sensor.

• Both sensors are heated.

Maintenance

& Calibration

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 17

19” Stationary Dust Monitor EDM 180Field Test Adapter for the 180

FLOW TEST

and

ZERO TEST

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 18

CALIBRATION TOWER

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 19

Test Sites Class III Continuous Monitors

A: Bakersfield, CA

B: Denver, CO

C: St-Louis, MI

D. New Haven, CT

A: Winter & Summer

B & C: Winter Only

D: Summer Only

US EPA PM 2.5 Class III FEM Approval

US EPA PM 2.5 Class III FEM Approval

Grimm Trailer

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 21

FRM vs GRIMM

BAKERSFIELD

0

10

20

30

40

50

60

70

80

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45

DAYS

CO

NC

EN

TR

AT

ION

UG

/M3

FRM avg

Grimm Avg

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 22

CALIFORNIA TEST RESULTS

WinterSummer

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 23

FRM vs GRIMM

DENVER

0

5

10

15

20

25

30

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

DAYS

CO

NC

EN

TR

AT

ION

µG

/M3

FRM avg

Grimm Avg

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 24

FRM vs GRIMM

NEW HAVEN

0

2

4

6

8

10

12

14

16

18

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

DAYS

CO

NC

EN

TR

AT

ION

µG

/M3

FRM avg

Grimm Avg

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 25

Results Lindon, UT Jan-Feb 2007 by US EPABRETT D. GROVER1, Russell W. Long1, Robert W. Vanderpool1, Robert W. Murdoch2, and Delbert J. Eatough3

1 U.S. Environmental Protection Agency, National Exposure and Research Laboratory, Durham/RTP, NC 277112 RTI International, Durham/RTP, NC 27709

3 Brigham Young University, Department of Chemistry and Biochemistry, Provo, UT 84602

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 26

180

107164 365

665

US EPA

Approved

Family of Products

Grimm Aerosol 2011© Grimm Aerosol Technik GmbH & Co. KG 27

Grimm offer:�Simultaneous measurement of PM10 & PM2.5

�Low Maintenance

�Fast Response (6 sec)

�Real-Time Monitoring

�Insensitivity to vibration (mobile)

�Lowest Ownership Cost

CONCLUSION