35 m²Electrical Plant Room

36 m²Boiler Room

32 m²Solar Plant Room

45 m²Water Plant Room

24 m²Hall

5 m²Service Riser

114FD30

115FD30

125FD30

138139FD30

140FD30

141FD60

142FD30

CarPark Exit

CarPark Entrance

28 m²Stair 4

18 m²Building Contol Centre

7 m²Bed Lift

5 m²Lift

37 m²Lobby

FD 31FD30

37.5m (TD)

26.1m (TD

)

69.000°

9.9m (OD)

12

3

45

67

89

10

11

12

14

15

16

17

18

19

20

21

22

23

24

13

A

B

CD

EF

H

I

J

K

L

M

P

5300

6FD30

8FD30

9FD30

10FD3011

FD3012FD3013

FD3014FD30

15FD30

17FD30

18FD30

34FD30

36FD30

37FD30

38FD30

39FD30

42FD30

43FD30

44FD30

45FD30

46FD30

47FD30

48FD30

49FD30

50FD30

109FD30

110FD30

111FD30

16 m²Book TR Room

24 m²Speech Therapy

20 m²Stair 3

27 m²Speech Therapy

14 m²Book TR Room 16 m²

Medical Store

4 m²WC & Shower

4 m²Staff WC

6 m²Hall

9 m²Womens Toilets

4 m²Womens WC

8 m²Mens Toilets

5 m²Mens WC

18 m²Wound Clinic

11 m²Medical Store 18 m²

Wound Clinic

15 m²Bookable Room

28 m²Family Rm/Care Doc

34 m²Reception

30 m²Waiting Area

20 m²Community Welfare

15 m²Bookable Room

18 m²Room

17 m²Child Health

17 m²Sound Proof Room

14 m²Stairs

32 m²HSE Circulation

359 m²Pharmacy

120 m²Medical Services Rm1

116 m²Medical Services/Storage

19 m²HSE Store

11 m²HSE Hall

34 m²HSE Dr Room

51 m²HSE Reception & Treatment Rm

16 m²HSE Office

127FD60

128FD60 69

FD60 81 FD30

80 FD30

79FD30

78FD30

129

FD30

15 m²Stairs 1

29 m²Stair 4

112 m²Restaurant /Caffe

80 m²Medical Services 67 m²

OT GA Room

72FD60

77 FD30

71 FD30

76FD30

70 FD30

73FD60

74FD60

75 FD60

82 FD60

9 m²WC F

5 m²Hall

9 m²WC M 14 m²

Storage 7 m²Hall

4 m²WC

107 106FD60

108

136FD60

135

FD60

133

FD60

91 m²Room

4664

2703

5190

14.2m (O

D)

27.1m (TD)9.3m (TD)

15.6m (TD)

18.4m (TD)

6.9m

(OD)

5.6m (TD

)

www.autodesk.com/revit

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

1 : 200

19/0

4/20

16 1

8:16

:59

Fire Certificate Plans

Project Number 3

Carlow Primary Health Care Centre

22/04/2016

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A129

1 : 200Fire Basement floor plan1

1 : 200Fire Ground floor plan2

LEGEND:Travel Distances:

- One Direction: OD- Two Direction: TD

30 min protected corridor in accordancewith section 1.2.5.1.and table A1 TGD B 2006

60 min protected stair wall in accordancewith table A2 TGD,Part B 2006. i.e. topstorey served not more than 5m aboveGround level

90 min protected stair well in accordancewith table A2 TGD, Part B 2006. Top storeyserved not more than 20m above Ground Level

90 min compartment wall/floor in accordancewith section 3.2, table A2 and appendix C,TGD B 2006

30 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted

Disabled refuge area (1400x900mm). Two waycommunication to the internal refuge area only

Emergency escape lighting to comply with table 1.8 TGD B-to be designed , installed and certified in accordance withIS 3217:20013.

Fire detection system type L1 to be designed, certified inaccordance with IS 3218:2009(2013)

The use, inspection and maintenance of fire extinguishersto be designed , installed and certified in accordance withIS 291:2002

Steel columns, beams and portal frames used to supportload bearing, fire resisting elements of structure to beprotected and to give 90min fire rating

60 min fire resistant door set in accordancewith BS476 Part 22, fitted with Intumescentstrips and smoke seals. Doorset to be fittedwith automatic self-closing device which shallbe capable of closing the for from any angleand against any latch fitted

NOTES:(1) Refers to area of room or storey, as appropriate, with area calculated in accordance with Section 1.0.10(a) of TGD-B 2006.(2) Occupancy load factors as per Table 1.1 of TGD-B 2006.(3) Such areas will generally be unoccupied or alternatively will be occupied by the same persons within the remainder of the

premises and therefore double counting of both areas are avoided.(4) Number of persons to such rooms taken as two (i.e. a patient and a consultant)