FINAL-AltairStrickland WhitneyStrickland ...€¦ · C t Pi lifti d iCenter Pipe lifting device 2....

Post on 30-Apr-2020

3 views 0 download

Transcript of FINAL-AltairStrickland WhitneyStrickland ...€¦ · C t Pi lifti d iCenter Pipe lifting device 2....

IntroductionIntroductionWhitney Strickland has been in the business of

providing turnaround services for the refining and t h i l i d t i f 25petrochemical industries for over 25 years.

Starting from working at WilsonStrickland's shop at the age of fourteen to field work as a laborer when sixteen years old and moving through the ranks of

l diff t t d i lt i tseveral different turnaround specialty companies to the position of superintendent. Then after 15 years of field experience came back to work at AltairStrickland in 1998 to implement the systems

d d d d f th t iand procedures needed for the company to grow in the way of providing manpower, better efficiencies in the field administration, networking capabilities and overall information and communication i f t t Whit St i kl d i h l i thinfrastructure. Whitney Strickland is now helping the AltairStrickland Companies grow into the best contractor for Turnarounds and Revamps as the Vice President and Chief Marketing Officer of Alt i St i kl d H ldi LLC

1

AltairStrickland Holdings, LLC.

Presentation OverviewPresentation Overview

• About AltairStricklandAbout AltairStrickland• Case Study: cone

replacement and weldreplacement and weld repairs during TurnaroundTurnaround

• Coke Drum removal C t Pi lifti d iCenter Pipe lifting device

2

AltairStricklandAltairStrickland

• 30+ years of Turnarounds and Revamps30+ years of Turnarounds and Revamps• General Mechanical Contractor we plan,

manage and execute complete projectsmanage and execute complete projects• Specialize in FCCU and Coker Revamps,

l difi tivessel modifications• Affiliated Companies: Refractory, Specialty

Tower, Specialty Piping and Pipe Fabrication

3

Case StudyCase Study

• 4 Drums 2 were4 Drums, 2 were 2.25cr and 2 were 3cr3cr

• Project involved installation of newinstallation of new cone sections which were 2 25crwere 2.25cr

• Repairs on Skirts d i T d

4

during Turnaround

Cone InstallationCone Installation• Performed three welding procedures, all in

accordance to ASME Boiler and Pressure Code Section IX

• Coupons were 1.5 inch thick single-V SA-387 SMAW process in vertical positionp p

• 400 degree preheat with 650 degree max interpass temp was usedinterpass temp was used

• E9018-B3, E9015-B3 and E9016-B39016 B3 tili d b t i l d

5

• 9016-B3 was utilized but was special order

Cone InstallationCone Installation

6

Cone InstallationCone Installation

• Cones cut belowCones cut below tangent but above existing weld seamexisting weld seam

• Bevel slanted to IDTIG t d h t• TIG root and hot pass with back gouge on OD

• SMAW 1/8” rod

7

Cone InstallationCone Installation

• Preheat 400Preheat 400• Phased Array testing in lieu of X-ray

W ld T i i• Welder Training• PT testing on OD • 410 ss overlay ferrite testing• DHT Bakeout for any ‘cool downs’DHT Bakeout for any cool downs• Zero weld reject rate

8

Cone InstallationCone Installation

• Drums HydrotestedHydrotested

• Over 40 traveler d tdocuments

• Complete TA was 27 days

9

Skirt Crack RepairsSkirt Crack Repairs

• Several Hundred repairs around keyholesI l R i d• Inconel Repair procedure

• Magnetic Particle Testing then stress relieving

• Average 4-5 days for each skirtg y• Had to do work after hydro due to weight

10

Center Pipe Lifting DeviceCenter Pipe Lifting Device

11

Center Pipe Lifting DeviceCenter Pipe Lifting Device

12

Center Pipe Lifting DeviceCenter Pipe Lifting Device

13

Center Pipe Lifting DeviceCenter Pipe Lifting Device

14

Center Pipe Lifting DeviceCenter Pipe Lifting Device

• Increases Safety FactorD l t d f lifti d t ili• Deletes need for new lifting and tailing lugs

• Reduces time due to no welding or PWHT for new lugs

15

Thank youThank you

Whitney K. Strickland281.478.6200

wstrickland@altairstrickland.com

16